Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Eprocure

Opening Date

10 Nov 2018

Closing Date

Cancelled

Tender Amount

₹ 67,00,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
EXCAVATION & EARTHWORK FOR SITE CLEARANCE AND AREA DEVELOPMENT, OTHER SCHEDULES (EXCEPT SCH 'A' PART-I) (Sch 'A' PART-II)

-

-

-

... More
Lump sum price worked out by the Contractor for “EXCAVATION & EARTHWORK FOR SITE CLEARANCE AND AREA DEVELOPMENT, OTHER SCHEDULES (EXCEPT SCH 'A' PART-I)” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 65,62,590.70 inserted by the MES in Schedule ‘A’ Part-II.

1

-

-

... More
EXCAVATION & EARTHWORK FOR SITE CLEARANCE AND AREA DEVELOPMENT, OTHER SCHEDULES (EXCEPT SCH 'A' PART-I) (Sch 'A' PART-II(A)) (MISC))

-

-

-

... More
Rough excavation n.exc 1.50 mtr deep and getting out in soft/ loose soil & removing excavated soil to distance exc 1.5 Km but n.exc 5 km to site of work and depositing where directed and passed by GE including spreading and levelling in layers n,exc 25 cm thick, watering, well ramming (Earth shall be obtained from outside of MOD land under contractors own arrengement and cost of earth as approved by GE/EIC)

4000

-

-

... More
Sub total

-

-

-

... More
INTERNAL WATER SUPPLY (Sch 'A' PART-III)

-

-

-

... More
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY (Sch 'A' PART-III)” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,40,036.10 inserted by the MES in Schedule ‘A’ Part-III.

1

-

-

... More
INTERNAL WATER SUPPLY (Sch 'A' PART-III(A) (MISC))

-

-

-

... More
S&F 15 mm bore Galvanised miedium grade water tubing concealed in walls/floors including necessary cutting chasses trimming and making good disturbed surface concrete complete all as specified and directed.

95

-

-

... More
S&F 20 mm bore Galvanised miedium grade water tubing concealed in walls/floors including necessary cutting chasses trimming and making good disturbed surface concrete complete all as specified and directed.

250

-

-

... More
S&F 25 mm bore Galvanised miedium grade water tubing concealed in walls/floors including necessary cutting chasses trimming and making good disturbed surface concrete complete all as specified and directed.

90

-

-

... More
Supply and fix health faucet (ABS body) with 01 metre long PVC tube & wall hook complete all as specified and directed. complate all as specified and directed.

30

-

-

... More
Supply and fix 15mm bore two way bib cock/tap complete all as specified and directed

30

-

-

... More
Sub total

-

-

-

... More
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 11,89,977.20 inserted by the MES in Schedule ‘A’ Part-IV.

1

-

-

... More
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV(A) (MISC))

-

-

-

... More
M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl provn of MS Sunken boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for MS Sunken boxes & making good to walls, floors etc. complete all as specified & as directed for the following :

-

-

-

... More
(a) One Light point controlled by one switch 5/6 Amps.

2653

-

-

... More
(b) One Ceiling Fan point controlled by one switch 5/6 Amps.

573

-

-

... More
(c) One Exhaust Fan point controlled by one switch 5/6 Amps.

265

-

-

... More
(d) One switch socket out let point 5/6 Amps on independent board.

1066

-

-

... More
(e) One call bell/buzzer point controlled by one bell push.

30

-

-

... More
M & L for concealed FLAME PROOF point wiring with two single core1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including stove enamelled steel conduit (medium grade) with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl provn of MS Sunken boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for MS Sunken boxes & making good to walls, floors etc. complete all as specified & as directed for the following :

-

-

-

... More
(a) One Light point controlled by one switch 5/6 Amps.

26

-

-

... More
(b) One Exhaust Fan point controlled by one switch 5/6 Amps.

2

-

-

... More
M & L for concealed point wiring with two single core 2.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non- metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked incl provision of 2.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl provn of MS Sunken boxes of appropriate size & thickness fixed flush to wall for housing 15/16 Amps switch-socket outlets etc. on independent board complete all as specified and as directed.

324

-

-

... More
S&F RJ 11 Tel Jack Telephone socket with shutter complete complete all as specified & as directed

60

-

-

... More
S&F TV Socket outlet with sheet metal box complete all as specified and directed .

92

-

-

... More
S&F RJ 45 Data Outlet with shutter complete all as specified and directed.

26

-

-

... More
Supply, install, testing & commissioning of ceiling fan 1400 mm sweep, Air Delivery not less than 245 CMM, heavy duty, single phase, AC, 230 Volts, 50Hz, 5 star rating, ISI marked complete with 30 cm down rod, canopy, blades, motor etc and connecting up complete including provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan including writing of MES Number 2.0 cm height with synthetic enamel paint complete all as specified & as directed.

573

-

-

... More
Supply, install, testing & commissioning of exhaust fan with automatic back shutter louvers 250 mm sweep, 1280 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan including writing of MES Number 2.0 cm height with synthetic enamel paint incl making of suitable sized hole in the wall for fixing of the exhaust fan & making good the disturbed surfaces complete all as specified & as directed.

265

-

-

... More
All as per Item Sl No 6.15 here in before but 300/305 mm sweep, Air Delivery 1120 CFM, FLAME PROOF type & 1440 RPM complete all as specified & as directed

2

-

-

... More
S & F lamp holder, PVC/polycarbonate type with back plate suitable for LED lamp and including LED lamp retrofit 7 watt complete all as specified and as directed.

264

-

-

... More
S & F, IP 20, Class I, LED light fitting 1 x 40 W (4 FT) , CRI = 80, CT =5700 K, wall / surface mounted, integrated type, constructed of fire retardant engineering grade extruded plastic & decorative end caps with integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy 95 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 40 W (4 FT) LED lamp or strip LEDs all as per OEM with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed.

384

-

-

... More
S & F CMRI Certified LED Flameproof 2 x 20 W ( 4 FT) LED tube light fixture, 230 V, wall mounted suitable for Gas / Vapour Group of IIA & IIB & Zone 1 & 2 with protection class IP 65 and including integrated electronic driver, energy efficient, bipin holders, connector block, fixed with suitable fixing arrangement complete including 02 Nos 20 W (4 FT) LED lamp or strip LEDs all as per OEM with all accessories internally prewired and including connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified and as directed.

23

-

-

... More
S & F, IP 20, Class I, LED light fitting 1 x 20 W (4 FT), CRI = 80, CT =5700 K, wall / surface mounted, integrated type, constructed of fire retardant engineering grade extruded plastic & decorative end caps with integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy 95 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including 01 No 20 W (4 FT) LED lamp or strip LEDs all as per OEM with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed.

926

-

-

... More
S & F CMRI Certified LED Flameproof 1 x 20 W ( 4 FT) LED tube light fixture, 230 V, wall mounted suitable for Gas / Vapour Group of IIA & IIB & Zone 1 & 2 with protection class IP 65 and including integrated electronic driver, energy efficient, bipin holders, connector block, fixed with suitable fixing arrangement complete including 01 Nos 20 W (4 FT) LED lamp or strip LEDs all as per OEM with all accessories internally prewired and including connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified and as directed.

3

-

-

... More
S & F IP 20, Class I, LED Mirror light fitting 1 x 10 W, CRI = 80, CT =5700 K, wall / surface mounted, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy 95 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including 01 No 10 W LED lamp or strip LEDs all as per OEM with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed.

57

-

-

... More
S & F energy saving & environment friendly long life 25 W, CT =5700 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy 110 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz complete incl bracket made out of 40 mm dia light grade GI pipe duly fixed with MS clamps nut, bolts etc including connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed.

183

-

-

... More
S & F, IP 20, Class I, surface mounted LED round type downlight 10 W, CRI = 80, CT =5700 K, integrated type, with high efficiency electronic driver , surge suppressor of 2 KV or more & high brightness LEDs, luminaire efficacy 95 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed.

710

-

-

... More
S & F, IP 20, Class I, surface mounted LED round type downlight 15 W, CRI = 80, CT =5700 K, integrated type, with high efficiency electronic driver , surge suppressor of 2 KV or more & high brightness LEDs, luminaire efficacy 95 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed.

63

-

-

... More
M & L for concealed sub-main wiring alongwith earth wire of size (4 x 16.0) sq. mm + (2 x 16.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for MS sunken boxes & making good to walls, floors etc. complete all as specified & as directed. (NOTE : Four runs of PVC wire, two run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length complete all as specified and directed.)

30

-

-

... More
M & L for concealed sub-main wiring alongwith earth wire of size (4 x 10.0) sq. mm + (2 x 10.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for MS sunken boxes & making good to walls, floors etc. complete all as specified & as directed. (NOTE : Four runs of PVC wire, two run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length complete all as specified and directed.)

155

-

-

... More
M & L for concealed sub-main wiring alongwith earth wire of size (4 x 6.0) sq. mm + (2 x 6.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for MS sunken boxes & making good to walls, floors etc. complete all as specified & as directed. (NOTE : Four runs of PVC wire, two run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length complete all as specified and directed.)

230

-

-

... More
M & L for concealed sub-main wiring alongwith earth wire of size (4 x 4.0) sq. mm + (2 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for MS sunken boxes & making good to walls, floors etc. complete all as specified & as directed. NOTE : Four runs of PVC wire, two run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length.

695

-

-

... More
M & L for concealed sub-main wiring alongwith earth wire of size (2 x 6.0) sq. mm + (1 x 6.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for MS sunken boxes & making good to walls, floors etc. complete all as specified & as directed. NOTE : Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length.

355

-

-

... More
M & L for concealed sub-main wiring alongwith earth wire of size (2 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for MS sunken boxes & making good to walls, floors etc. complete all as specified & as directed. NOTE : Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length.

1510

-

-

... More
M & L for concealed sub-main wiring alongwith earth wire of size (2 x 2.50) sq. mm + (1 x 2.50) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for MS sunken boxes & making good to walls, floors etc. complete all as specified & as directed. NOTE : Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length.

3342

-

-

... More
S & F MCB, SP, 10KA, 230V, "C" curve, 06-32 A, ISI Marked complete all as specified & as directed

1233

-

-

... More
S & F MCB, SPN, 10KA, 240V, "C" curve, 06-32 A, ISI marked complete all as specified & as directed

596

-

-

... More
S & F MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked complete all as specified & as directed

71

-

-

... More
S & F MCB, TPN, 10KA, 415V, "C" curve, 40 A, ISI marked complete all as specified & as directed

14

-

-

... More
S & F MCB, TPN, 10KA, 415V, "C" curve, 63 A, ISI marked complete all as specified & as directed

10

-

-

... More
S&F MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25/26 KA of rating 160A incl electric connection complete all as specified & as directed

1

-

-

... More
S&F MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 16/18 KA of rating 100A incl electric connection complete all as specified & as directed

1

-

-

... More
S&F MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 16/18 KA of rating 80A incl electric connection complete all as specified & as directed

2

-

-

... More
S & F Single Phase KWH meter with LCD display, Class – I with Optical port of rating 10 – 60 A complete with Hinged type box suitable for incorporating the meter all as per OEM including necessary fixing, mounting arrangements with electric connection complete all as specified and as directed.

10

-

-

... More
S & F temper proof Tri-Vector meter, Class – I, with LCD display, RS – 485 port, 03 Phase, 4-wire, rating 10 – 60 A complete with Hinged type box suitable for incorporating the meter all as per OEM including necessary fixing, mounting arrangements with electric connection complete all as specified and as directed.

5

-

-

... More
S & F 02 Nos lamp holders, PVC/polycarbonate type with back plate fitted upon PVC rectangular box of size 100 x 100 x 50 mm with an including 02 Nos LED lamp retrofit 0.5 watt (Red Colour = 01 No & Green Colour = 01 No) complete all as specified and as directed. (As Engagement Light in the office of CO)

1

-

-

... More
Supply, install, testing & commissioning of LT panel board "in-door pedastal type" of size 900 mm (height) x 600 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated (CPRI type tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 40 x 40 x 6 mm angle iron & MC 100 channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl arrangements for pedastal mounting complete all as specified & as directed with & incl the following accessories : (MAIN INCOMING PANEL SM BK, CH & DH)

1

-

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 35 KA of rating 160 A incl electric connection complete. OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 63 A incl electric connection complete - 02 Nos. (b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 80 A incl electric connection complete - 02 Nos. (01 No Spare)

-

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 200 A with built in selector Switch & 03 Nos CTs (Type : CBF-0.6-D1, Accuracy Class - 1.0, CT Ratio - 200/5, Burden - 10VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. (c) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
S&F, IP=20, Class I, ceiling mounting LED square shape slim ceiling light fitting 36W or next higher rating, CRI=80, CT=5700 K, suitable for 600x600mm (approx dimensions), integrated type, with high effeciency electronic driver, surge suppressor of 2 KV or more & high brightness LEDs, luminaire efficiancy 95 lumens/watt, power factor=0.90, oprating range -140 to 270V, 50Hz with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed .( For lighting of Dinning Hall).

36

-

-

... More
Sub total

-

-

-

... More
EXTERNAL WATER SUPPLY (Sch 'A' Part-V)

-

-

-

... More
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,37,622.50 inserted by the MES in Schedule ‘A’ Part-V.

1

-

-

... More
EXTERNAL WATER SUPPLY (Sch 'A' Part-V(A) (MISC))

-

-

-

... More
M&L for drilling of Trial bore of 200 mm dia upto 150 mtrs depth below ground level by any suitable method as per soil condition and CG WB report, through any kind of soil, boulders, rocks etc. for a bore size 200 x 150 mm dia as required at site including disposal of spoil from the site of work complete all as specified & as directed. NOTE : (i) After complete drilling of the borehole electric logging to be carried out for exact selection of strata & the same will be measured & paid separately under relevant items of schedule. (ii) In case the results of the borehole/strata are found un-satisfactory & the tubewell is not likely to yield the specified quantity of water, the site shall be abandoned & the contr shall be paid for the boring part only.

150

-

-

... More
M&L for development of trial bore by reaming upto 525 mm for 150 mtrs depth from ground level using any suitable method as per soil condition and CG WB report including disposal of spoil from the site of work complete all as specified & as directed.

150

-

-

... More
Electric logging of bore for precise delineation of granular zones & also the quality of ground water including report interpretation complete all as specified & as directed. NOTE:- Electric logging shall be carried out by any approved Govt Agency.

1

-

-

... More
Supplying and assembling including jointing, lowering & fixing in position ERW casing pipe fine cut of internal dia 200 mm bore of thickness 7 mm confirming to IS 4270-2001 (ISI marked) including jointing of pipe by necessary electric arc welding both sides. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified & as directed.

50

-

-

... More
Supplying and assembling including jointing, lowering & fixing in position ERW casing pipe fine cut of internal dia 150 mm bore of thickness 6 mm confirming to IS 4270-2001 (ISI marked) including jointing of pipe by necessary electric arc welding both sides. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified & as directed.

70

-

-

... More
Material and labour for packing pea graval 3 to 5 mm of size as per IS of natural shape brought directly from river bed and packing around the casing pipe of MS to entire depth upto ground level complete all as specified and as directed

23

-

-

... More
Supply and fixing MS centralising guide all as specified in IS : 2800 (Part – 1) : 1991complete all as specified & as directed

15

-

-

... More
Supply lowering and fixing/ jointing 150 mm bore low carbon galvanised (LCG) strainer 3 mtr/ 6 mtr long min 6 mm thickness each conforming to IS 8110:2000 including mild steel socket threaded/ by electric arc welding both sides all as specified and directed with aperture 0.75 mm to 1 mm as per requirement complete all as specified & as directed

30

-

-

... More
Supply and fixing well cap suitable for 200 mm bore housing pipe made out of 6 mm thick steel plate complete all as specified and directed. NOTE : After completion of the work well cap will be used to keep the bore well closed until the submersible pumping set is installed.

1

-

-

... More
M&L for development of tube well with air compressor of suitable capacity till sand/mud free water of potable quality is obtained & to achieve minimum discharge capacity of 36000 LPH/max yeild (Compressor with accessories & tube etc. shall be arranged by the contractor) complete all as specified & as directed.

48

-

-

... More
Development of tube well by over pumping 25% using suitable size/type of pump after completion of item above, including yield testing for tube well as per IS requirements complete all as specified & as directed NOTE :- Yield test of bore well shall be carried out in the presence of rep of Accepting Officer.

24

-

-

... More
Supply only strata sample box with glass cover 3mm thick having internal dimension 1000x600x100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various depth evenly 2 mtr interval met in boring including strata chart in duplicate complete all as specified & as directed

1

-

-

... More
Testing of water (Raw Water & Treated Water) from approved Govt lab for potability by doing chemical and bacteriological analysis as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge.

1

-

-

... More
Supply, lowering, jointing & testing MS Black column pipe 3.0 mtr long, heavy duty, 80 mm bore, wall thickness 5.4 mm, both ends flanged, ISI Marked with heavy duty MS flanges not less than 16 mm screwed & welded inside & outside with pre-drilled holes including jointing with rubber gasket, nuts, bolts, washers & necessary grooves for facilitating submersible cables, steel ropes etc. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified & as directed.

45

-

-

... More
S&F flat submersible cable 3 core multi stranded copper conductor PVC insulated, water proof, ISI marked of size 6 sqmm for connecting from starter to bore well submersible pump sets complete all as specified and as directed.

120

-

-

... More
S&F mild steel work as in joist channel, angles or tee sections plates fixed independently with or without connecting plates etc cut to required length and shape including two coats of synthetic enamel paint over one coat of red-oxide primer complete all as specified & as directed (Work for lifting assy of Submersible Pump Set).

400

-

-

... More
Supply and fixing bail plug of 150 mm internal dia threaded of minimum thickness 6 mm and 3 mtr long made up of mild steel and continuous welded by electric arc welding at both ends complete all as specified and directed.

1

-

-

... More
Supply and fixing chain pully block, triple spur gear, 2 ton capacity with 3 mtr lift, manually operated complete with hooks high tensile forged steel confirming to IS : 3815 and load confirming to IS: 6216 and hand chain to IS: 2429 (Part-I) complete all as specified & as directed

1

-

-

... More
Supply and fixing steel rope flexible 10 mm dia with GI clamps, nuts, bolts, washer etc for fixing of submersible pump set complete all as specified & as directed.

65

-

-

... More
M&L for MS Taper reducer of 200 x 150 mm with and including socket threaded and by electric arc welding both sides complete all as specified and as directed.

1

-

-

... More
S&F mild steel clamp suitable for 80 mm dia MS column pipe made out of 12 mm thick MS plate fabricated to shape, including drilling holes, nuts, bolts, washers etc complete all as specified & as directed.

2

-

-

... More
Supply, install, testing & commissioning of advanced encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology Zinc & Alloy coated earthing system confirming to IS - 3043 ( Code of practice for Earthing ) with the help of Zinc coated ( 80 - 100 microns ) & Alloy coated ( 200 - 250 microns ) GI pipes , one bag BFC (Back Fill Compound = Electrodite or any similar compound) incl. required excavation & earthwork complete. DETAILS : MATERIAL : Zinc & Alloy coated GI pipes. LENGTH : 2000 mm. DIA OF OUTER PIPE : 76.20 mm. DIA OF INNER PIPE : 41.90 mm. THICKNESS OF OUTER PIPE : 2.5 mm. THICKNESS OF INNER PIPE : 3.2 mm. BFC : One Bag ( 25 Kg Capacity ) (All the above given dimensions may vary +/- 0.1 mm )

4

-

-

... More
NOTE: 1) The annular space between the GI Pipes shall be filled up with crystalline conductive compound (CCC). It must be machine pressed in the pipes. 2) BFC should be eco-friendly & must not contain environmentally hazardous material/metal & must have ROHS Certification from NABL accredited lab.The quantity of BFC indicated above is generally for normal/good soils.In case the soil resistivity is high , the quantity of BFC should be increased & cost of the same is deemed to be included in the unit quoted rates. 3) The rates are also inclusive of provn of concrete pit in PCC (1:3:6) type C - 1 precast RCC (1:2:4) cover slab of size 54 x 54 x 5 cm thick with one handle for its lifting made out of 8 mm dia MS round bar & 8 mm dia MS deformed bars 15 cm both ways as in reinforcement & GI strip 32 X 6 mm for connection of earthing with equipment to be earthed viz. Generator body/neutral etc.

-

-

-

... More
Supply, jointing, testing and laying in trenches/floor/wall etc in standard lengths, centrifugally cast (spun) ductile iron (DI) pressure pipes with inside cement mortar lining and black bitumen external coating of size 150 mm dia nominal diameter, class K-7 classification, conforming to IS-8329, ISI marked, including push on joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rated quoted.

445

-

-

... More
Supply, jointing, testing and laying in trenches/floor/wall etc in standard lengths, centrifugally cast (spun) ductile iron (DI) pressure pipes with inside cement mortar lining and black bitumen external coating of size 100 mm dia nominal diameter, class K-7 classification, conforming to IS-8329, ISI marked, including push on joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rated quoted.

610

-

-

... More
M&L for fittings ISI marked of size upto 150 mm bore suitable for DI pipes class K-12, PN 10 with inside cement mortar lining and black bitumen external coating, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and directed.

500

-

-

... More
Supply, install, testing & commissioning of CI Non-Return (Reflux) Valve 150 mm bore, both end flanged, class PN 1.6, ISI marked conforming to IS 5312 (Part I & II) including making new flanged joints with 3 mm thick rubber gasket with necessary bolts, nuts, washer etc of suitable size complete all as specified and as directed.

2

-

-

... More
Supply, install, testing & commissioning of Air release valve, Cast iron, double air outlet, flanged ends, 100 mm bore connected to the main line complete all as specified and as directed.

1

-

-

... More
Supply, install, testing & commissioning of Air release valve, Cast iron, double air outlet, flanged ends, 80 mm bore connected to the main line complete all as specified and as directed.

1

-

-

... More
M&L for construction of brick masonary valves pit of internal dimensions 1000mm x 1000 mm x 1000 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and as directed.

8

-

-

... More
M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and as directed.

3

-

-

... More
M&L for construction of brick masonary valves pit of internal dimensions 600mm x 600 mm x 600 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and as directed.

14

-

-

... More
Supply, install, testing and commissioning of chlorine pressure feed, high pressure single head gear motorised adjustable dozing pump with accessories including suction / discharge tubing, connecting nuts, injection check valves, foot valve, strainer. clay weight and ferrules, multi stage centrifugal pumps, starter control cabling etc. of capacity upto 1000 grams/hr complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commissioning of liquid chlorine dozing system consisting of 100 ltr capacity FRP solution preparation cum settling tank with lid, port hole, inlet / outlet / drain connection, level guage etc. & fitted with speed reducing motor & SS-316 agitator mounted on tank complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commissioning of " indoor cubical type " LT Distribution Control Board of size 1000 mm (height) x 1000 mm (breadth) x 600 mm (depth) (minimum dimensions) factory fabricated CPRI approved with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 40 x 40 x 6 mm angle iron & MC 100 channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories : (PUMP HOUSE PANEL)

1

-

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING/OUTGOING/INSTRUMENTATION SYSTEM : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capaity 25 KA of rating 63A - 01 Nos. (b) Submersible pump controller in sheet enclosure fully automatic star-delta starter type confirming to IS 13947-4-1 suitable for motor rating upto 15 HP, AC 3 duty, 415 V (Coil Voltage - 25 to 450 V), 50 Hz, 3 Phase, relay range 18-25 A complete with Heavy duty 4 Pole Contactor, Overload Relay, Auto Start switch, 3 Position selector switch for SPP Auto / SPP Manual / Manual, Voltmeter with selector switch, supressed scale Ammeter, RYB LED indicator Motor ON & Trip LED indicator, TP "C" curve MCB for short-circuit protection.

-

-

-

... More
(c) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 63 A, 415 V, 4P with Positive Isolation, Door Interlock & Padlock facility. (d) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. NOTE : 1) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
Supply, install, testing, and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set water cooled including AMF panel for standby power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, 50 KVA (40.0 KW) or next higher standard size available at 0.8 power factor complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter 12 volt, fuel tank capacity not less than 08 hours fuel requirement & battery as reccommended by OEM battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based gen-set controller with the following under-mentioned features & all as specified & as directed : a) Alphanumeric LCD display with LED backlight. b) Operator interface. c) Suitable to provide a record of most recent fault conditions & fault history. d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA , frequency etc.

1

-

-

... More
e) Complete engine data viz, starting battery voltage, engine temp, engine runnning hours, engine oil pressure etc. f) Control incl provn of service adjustment & calibration of DG control functions. GENSET SPECIFICATIONS : PRIME MOVER RATING : 50 KVA / 40.0 KW CURRENT RATING : 70 A NO OF PHASES : 03 POWER FACTOR : 0.8 (LAG) ENGINE SPECIFICATIONS : BHP : 69 COOLING : WATER COOLED ASPIRATION : TURBO-CHARGED NO OF CYLINDERS : 04 RPM : 1500 GOVERNOR : MECHANICAL STARTING SYSTEM : 12 V ELECTRICAL ALTERNATOR SPECIFICATIONS : VOLTAGE : 415 RPM / FREQUENCY : 1500 / 50 HZ ENCLOSURE : IP 23

-

-

-

... More
VOLTAGE REGULATION (MAX) : +/- 1 % INSULATION CLASS : H CLASS CONFORMANCE STANDARDS : IS 4722, BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046. Make of Battery : As reccomended by OEM AMF PANEL SPECIFICATIONS : AS PER MANUFACTURER SPECIFICATIONS NOTE: 1) Design / drawing / BOM of the AMF panel & DG SET showing the dimensions is to be obtained from the OEM / Auth Supplier & is to be got approved from GE before placing final order to the manufacturer. 2) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains. 3) The cost of servicing including minor repairs/replacement such as topping up of coolant, engine/lub oil, diesel as well as lub-oil filters including periodical checking of the complete DG set & AMF panel for the complete defect liability period as & when required is deemed to be included in the quoted rates

-

-

-

... More
4) Anything missed out in the technical specifications but technically required for efficient working of DG Set is deemed to be included in the quoted rates. 5) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test. 6) The quoted rate shall be deemed to be inclusive of 8 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer; all testing arrangements / equipments, resistive load including POL shall be made available by the contractor.

-

-

-

... More
Supply only Rubber Mat of 1 mtr x 2 mtr x 19 mm complete all as specified & as directed

2

-

-

... More
Supply only CHLORINE TEST KIT with coloured sample & test-tubes complete with all testing fitments and OT solution in Rexene finish box complete all as specified & as directed

1

-

-

... More
Supply only PH test kit with coloured sample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) & test-tubes with necessary fitments and 100 ml testing solution in rexene finish wooden box complete all as specified & as directed

1

-

-

... More
Supply only IRON Test Kit & test-tubes with necessary fitments and testing solution in rexene finish box complete all as specified & as directed

1

-

-

... More
Sub total

-

-

-

... More
EXTERNAL ELECTRIFICATION (Sch 'A' PART-VI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 41,96,629.00 inserted by the MES in Schedule ‘A’ Part-VI.

1

-

-

... More
EXTERNAL ELECTRIFICATION (Sch 'A' PART-VI(A) (MISC))

-

-

-

... More
Supply, install, testing & commissioning of transformer platform/plinth mounted of capacity 400 KVA step down, BEE 5 Star Rated (Energy Efficiency Level 3), outdoor type 11.0/0.433 KV, 50 Hz, AC double wound core type, copper wound, oil immersed type, naturally air cooled with external cooling tubes, transformer delta connection on HT side & star connection on LV side in accordance with vector symbol DyN 11 (vector group - 4) with off-load tap changer on HT side to vary secondary voltage +/- 7.5% in equal steps of 2.5% as per IS – 1180 (Part-I) - 2014. The voltage regulation shall be as per IS incl first fill of transformer oil upto appropriate level all as per IS-335 all as specified & as directed comprising with & incl the following specifications : (a) 01 No cable end box on HT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of HT 11000 V grade XLPE insulated heavy duty cables incl glands complete. (b) 01 No cable end box on LT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of LT 1100 V grade XLPE insulated heavy duty cables incl glands complete all as specified & as directed

1

-

-

... More
© Oil conservator with filter type drain valve & oil level gauge. (d) Explosion vent with double diaphragm & sight glass. (e) Thermometer pocket. (f) Two earthing terminal on tank body to facilitate fixing of 32 x 6 mm GI strip etc. (g) 01 No thermometer dial type, vapour pressure type having range 0 to 120'C with maxm temperature indicator, re-setting device & marked maxm temp reading point. (h) Rating plate with terminal marking plate. (j) Oil level gauge. (k) Oil drain filter valve. (l) Oil filling port on top cover with plug. (m) Air release valve / plug. (n) 04 Nos plain solid cast steel detachable rollers. (o) First fill of transformer oil confirming to relevant IS & tested upto 60 KV dielectric strength. (p) Inspection cover. (q) Lifting lugs & jack lifting pad & support. ® Silica gel breather without / with connecting pipes, first fill of dehydrating agent. (s) Cover lifting eyes.

-

-

-

... More
(t) Oil temperature indicator of approved range, incl shut off valve between conservator & main tank. (u) Additional / Extra bushing for neutral outside of LV side. NOTE: 1) Design / drawing / BOM of the Transformer showing the dimensions is to be obtained from OEM / Auth Supplier & is to be got approved from the GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

370

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

1840

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

190

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

30

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

50

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

240

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4.0 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

680

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4.0 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed.

5720

-

-

... More
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2.0 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed. NOTE FOR ITEM NO - 10.04 to 10.12: Necessary earthwork, brick protection etc.

3020

-

-

... More
S & F energy saving & environment friendly long life 60 W, CT =5700 K, LED Street light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, built-in surge suppressor / SPD of 10 KV or more & high brightness LEDs, luminaire efficacy 110 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz complete incl suitable fixing arrangement complete all as specified & as directed.

132

-

-

... More
S&F factory fabricated (CPRI type tested) weather proof, dust & vermin proof street light junction box of size 250 (L) x 250 (B) x 150 (D) mm (minimum dimensions) made up of 3.15 mm thick CRCA sheet, powder coated after preparation of surfaces comprising of 04 Nos aluminium bus-bar of size 20 x 4 mm mounted on suitable size spacer insulators with provn of 01 No MCB SP 6 Amps, 10 KA breaking capacity, "C" curve & two openings at the bottom & one opening at the top with cable glands & fixing with the help of suitable sized MS clamps to steel poles incl testing complete all as specified & as directed.

178

-

-

... More
Supply, install, testing & commissioning of Automatic Power Factor Correction (APFC) panel outdoor type, factory made of 150 KVAR capacity ready to use design confirming to IS 5039 / IS 8623 & relevant IS/IEC codes rated for short circuit current rating of 50 KA, front openable & lockable by keys having louvers & air vent, gasket & totally vermin proof & suitable for 415/440 V, 3 Ph, 50 Hz, AC & housed in elegant enclosure fabricated from minimum 3.15 mm thick CRCA sheet & min 2.0 mm thick for partitions anti-corrosive coating to improve power factor to 0.99 & finally powder coated in texture siemens grey RAL 7032 incl suitable size & length of copper conductor cable PVC insulated for controls to each capacitor with & incl the following accessories : (a) 300 A capacity tinned copper bus-bar duly insulated with colour coaded heat shrinkable sleeves & mounted on suitable sized DMC/epoxy insulators. (b) MCCB 4P, 250 Amps,25 KA breaking capacity (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting - 01 No as Incoming.

1

-

-

... More
(C) A set of heavy duty, capacitor heavy duty, type MDXL or any suitable type, 440 V with output capacity 150 KVAR, capacitor bank in suitable steps & configuration to accommodate all possible set for automatic operation to maintain 0.99 power factor. (d) MCBs TP, "C" series, 415 V of required sizes with required numbers & suitable ratings as per the capacity of the capacitors. (e) Microprocessor based control suitable for power factor correction with its unique features of four quadrant operation C/K ratio selection. The APFC controller should ON/OFF the capacitor banks of 150 KVAR capacity in suitable steps & configuration with indication whether it is lagging or leading. (f) Power Contactors heavy duty for suitable capacitors shall be provided for automatic operation of each capacitors with ON/OFF indications. (g) The APFC panel shall be provided with two external terminals, connected through GI strip 32 x 6 mm to existing transformer earthing / panel earthing all as specified & as directed. (h) Digital panel meters for current, voltage, frequency & power factor having programmable CT ratio & built in selector switches of size 96 x 96 mm, accuracy class-I, auxiliary support of 230 V, AC with SP MCB protection shall be provided.

-

-

-

... More
(j) All control wires shall be not less than 2.5 sqmm, multistranded, copper conductor & properly bunched/tied, ferruled for proper identification & crimped with adequate size of lugs. The cubicle will have a bottom support of channel of suitable size duly coated with zinc metal coating. A detachable pre-drilled gland plate of thickness 3.15 mm thick, cold zinc metal coated shall be provided with at the bottom for entry for armoured cable with adequate size of gland. Manufacturer name plate with feeder details & danger notice plate shall also be provided at suitable visible place. (k) Auxiliary contactor with required quantity of NO & NC contacts. (l) Auto/Manual Switch - 01 No. (m) Indicator lamp LED based with lamp holder all as specified & as directed. (n) CT of ratio 300/5 A, measuring class accuracy 0.5 to 1.0 for capacitor panel. (o) Spare CT 01 No of ratio 300/5 A & necessary control cabling for sensing the pf in the main panel for APFC operation. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
Supply, install, testing & commissioning of advanced encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology Zinc & Alloy coated earthing system confirming to IS - 3043 ( Code of practice for Earthing ) with the help of Zinc coated ( 80 - 100 microns ) & Alloy coated ( 200 - 250 microns ) GI pipes , one bag BFC (Back Fill Compound = Electrodite or any similar compound) incl. required excavation & earthwork complete. DETAILS : MATERIAL : Zinc & Alloy coated GI pipes. LENGTH : 2000 mm. DIA OF OUTER PIPE : 76.20 mm. DIA OF INNER PIPE : 41.90 mm. THICKNESS OF OUTER PIPE : 2.5 mm. THICKNESS OF INNER PIPE : 3.2 mm. BFC : One Bag ( 25 Kg Capacity ) ( All the above given dimensions may vary +/- 0.1 mm )

4

-

-

... More
NOTE: 1) The annular space between the GI Pipes shall be filled up with crystalline conductive compound (CCC). It must be machine pressed in the pipes. 2) BFC should be eco-friendly & must not contain environmentally hazardous material/metal & must have ROHS Certification from NABL accredited lab.The quantity of BFC indicated above is generally for normal/good soils.In case the soil resistivity is high , the quantity of BFC should be increased & cost of the same is deemed to be included in the unit quoted rates. 3) The rates are also inclusive of provn of concrete pit in PCC (1:3:6) type C - 1 precast RCC (1:2:4) cover slab of size 54 x 54 x 5 cm thick with one handle for its lifting made out of 8 mm dia MS round bar & 8 mm dia MS deformed bars 15 cm both ways as in reinforcement & GI strip 32 X 6 mm for connection of earthing with equipment to be earthed viz. Generator body/neutral etc.

-

-

-

... More
Supply, install, testing & commissioning of LT panel board "out-door type" of size 1500 mm (height) x 1800 mm (breadth) x 600 mm (depth) (minimum dimensions) factory fabricated CPRI approved with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable & 4 side slanting canopy on roof top. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 X 50 X 6 mm angle iron & MC 100 channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork complete all as specified & as directed with & incl the following accessories : (MAIN PANEL FOR 400 KVA TRANSFORMER)

1

-

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 1000 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : Air Circuit Breaker (ACB), 4 pole having breaking capacity 50 KA Icu=Ics=Icw (1 Sec) of rating 800 A, manual draw-out type with the following features : (a) LSING Protection. (b) LCD Display. © Communication through RS-485 Port. (d) True RMS Sensing. (e) Current/Voltage/Power Measurement. (f) Thermal Memory. (g) Fault Indication with Trip History. (h) Zone Selectivity. (j) Harmonics.

-

-

-

... More
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 36 KA of rating 320A - 04 Nos. (3W + 1 S) (b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 35 KA of rating 250A - 01 Nos. (c) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 800 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 800/5, Burden - 15VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos.

-

-

-

... More
(e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No. NOTE FOR ITEM NOS - 10.22, 10.25, 10.27, 10.29, 10.31, 10.33, 10.35, 10.37 & 10.39) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) with 50 x 50 x 6 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FP - 2 ) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 500 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 36 KA of rating 400A. OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 36 KA of rating 320A - 02 Nos. (1W + 1 S) (b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 63A - 01 Nos.

1

-

-

... More
(c) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. (d) MCB, SPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 02 Nos. (1W + 1S) INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 500 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 500/5, Burden - 15VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) with 50 x 50 x 6 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FP - 3) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 400 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 36 KA of rating 320A. OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 160A - 02 Nos. (1W + 1S) (b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 63A - 01 Nos.

1

-

-

... More
(c) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 07 Nos. (5W + 2S) INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 400 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 400/5, Burden - 15VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 900 mm (height) x 900 mm (breadth) x 500 mm (depth) (minimum dimensions) with 40 X 40 X 5 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FP - 4) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 63A OUTGOINGS : (a) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 02 Nos. (1W + 1S) (b) MCB, TPN, 10KA, 415V, "C" curve, 40 A, ISI marked - 02 Nos. (1W + 1S)

1

-

-

... More
(c) MCB, SPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 02 Nos. (1W + 1S) INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 100 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 100/5, Burden - 5VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 1200 mm (height) x 1000 mm (breadth) x 500 mm (depth) (minimum dimensions) with 50 x 50 x 6 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FP - 5) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 300 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 35 KA of rating 200A. OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 63A - 03 Nos. (2W + 1S) (b) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 05 Nos. (4W + 1S)

1

-

-

... More
(c) MCB, SPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 09 Nos. (7W + 2S) INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 200 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 200/5, Burden - 10VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 1200 mm (height) x 1000 mm (breadth) x 500 mm (depth) (minimum dimensions) with 40 x 40 x 5 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FPB - 6) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 100A. OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 80A - 01 Nos. (1W + 1S)

1

-

-

... More
(b) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 03 Nos. (2W + 1S) (c) MCB, SPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 12 Nos. (10W + 2S) INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 100 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 100/5, Burden - 5VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 1200 mm (height) x 1000 mm (breadth) x 500 mm (depth) (minimum dimensions) with 40 x 40 x 5 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FP - 7 ) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 80 A. OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 63A - 02 Nos. (1W + 1S) (b) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 04 Nos. (3W + 1S)

1

-

-

... More
(c) MCB, SPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 02 Nos. (1W + 1S) INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 100 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 100/5, Burden - 5VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) with 50 x 50 x 6 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FP - 8) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 160A OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 125A - 02 Nos. (1W + 1S)

1

-

-

... More
(b) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 03 Nos. (2W + 1S) (c) MCB, TPN, 10KA, 415V, "C" curve, 40 A, ISI marked - 02 Nos. (1W + 1S) (d) MCB, SPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 02 Nos. (1W + 1S) INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 200 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 200/5, Burden - 5VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
All as per item Sl No - 10.20 here in before but of size 900 mm (height) x 900 mm (breadth) x 500 mm (depth) (minimum dimensions) with 40 x 40 x 5 mm supporting angle irons incl suitable PCC (1:3:6) type C-2 foundation complete all as specified & as directed with & incl the following accessories : (FP - 9) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 63A OUTGOINGS : (a) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 02 Nos. (1W + 1S) (b) MCB, TPN, 10KA, 415V, "C" curve, 40 A, ISI marked - 03 Nos. (2W + 1S)

1

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type AC Ammeter 0 to 100 A with built in selector Switch & 03 Nos CTs (Accuracy Class - 1.0, CT Ratio - 100/5, Burden - 5VA), 3 phase, Accuracy Class - 0.5, Size 96 x 96 mm. (b) Digital type AC Volt meter with built in selector Switch, 3 phase, 30-600 volts range, Accuracy Class - 0.5, Size 96 x 96 mm. © Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (e) Astronomical Time Switch 415 V, 03 Phase, 20 A incl Contactor with suitable no of NO/NC contacts fitted inside steel enclosure - 01 No.

-

-

-

... More
Supply only Rubber Mat of 1 mtr x 2 mtr x 19 mm. complete all as specified and directed.

3

-

-

... More
Supply, install, testing and commissioning of LED based Solar street light system stand alone type, on new pole incl LED street light system of 45 watt or nearest higher available rating capable of working on DC 24 volts power from battery unit, being charged by the solar photovoltaic array panel through charge controller, luminaire fixing arm made out of ISI marked GI pipe medium grade of dia 50mm of length not less than 0.5 mtr with suitable fixing arrangements as per manufacturer etc. The details of different items are as under :-(a) LUMINAIRE :- IP 65, full body, aluminium pressure die cast housing, LED type, 45W or nearest higher available rating (with minimum 21 Rebel LED's in series with Lens) all as specified and as directed suitable for battery system of 24 Volts DC. (b) Lead acid tubular Solar battery suitable for system voltage of 24V, Battery - 160 AH (80 X 2) (24 Months Warranty) of low maintenance type all as specified and directed. (c) Poly crystalline solar photovoltaic array panel conforming to all relevant IEC/IS standards of best quality. Ratings of this panel shall be min 180 Wp (90 X 2). The panel shall be suitably connected to battery through charge controller for its charging all as specified and directed. (d) Solar Charge controller all as conforming to relevant IEC/IS standards shall be provided to charge the battery from solar photo voltaic array panel all as specified and directed including suitable protection mechanism.

26

-

-

... More
(e) Battery box made out of 2 mm thick MS sheet powder coated with minimum 60 micron thickness, weather proof, including locking arrangement for housing batteries and necessary arrangement to fix on octagonal pole with suitable MS angle/ flat iron support duly painted with two coat of synthetic enamel paint over a coat of primer all as specified and as directed. (f) All the electrical fittings, batteries including box, solar photo voltaic array panel shall be fixed on a octagonal pole of 7m height from ground level all as specified and as directed. (g) Octagonal Pole 7 metre long, 3 mm thick, 100 mm in top and 165 mm at bottom, conforming to relevant IS/IEC standards. Thickness and other specification of pole shall be as per manufacturer and shall be capable of taking all types of load, wind load etc at Sukna area. The earth work, foundation, PCC, bolts, nuts etc of pole shall be as per manufacturer guidelines and quoted rate is deemed to be included all as directed. Note :- (i) Design / drawing / BOM of the LED type Solar Street Light System is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer.

-

-

-

... More
(ii) All the items like solar photo voltaic array panel, LED luminaire, solar charge controller, batteries etc shall confrom to relevant IEC/IS standards. (iii) All the fittings like pole, solar photo voltaic array panel, batteries, Luminaire etc. shall be procured directly from the OEM and a certificate from the manufacturer shall be provided to GE. (iv) Anything missed out above but is technically required for efficient operation of LED type Solar street light is deemed to be included in the quoted rates

-

-

-

... More
M&L for boring under road manually with labour suitable for inserting 100 mm bore pipe at a depth 0.75 to 1.0 mtr complete. all as specified and directed.

40

-

-

... More
M&L for cable route indicator using RCC post 1.20 mtr long, top 100 x 100 mm & bottom 200 x 200 mm, with height not less than 50 cm above GL with engraved marking " MES HT CABLE " in bold letters during refilling of the trench complete all as specified & as directed NOTE : The spacing between two consecutive cable route indicators shall not be more than 50.0 meters & also shall be provided at each & every bend or corner.

25

-

-

... More
Supply, errection, commissioning and testing of High Galvanized Mast Light 16 Meter High suitable for 6 nos 1X160W LED Flood light and having three point suspension system with steel wire rope of 6 mm dia and double drum winch with luminare mounting arm, 01 No. LED type aviation obstruction light including lamp, lightning arrester spike, power tools including cutting road/hard standing, excavation for RCC foundation and RCC foundation complete with following and all as specified & as directed : (a) High mast fabricated from steel plates conforming to BSEN-10025/IS:5986, cut and folded to from a polygonal section. Mast shall be in two sections for 16 Mtr heights having only longitudinal weld conforming to BS-5135/AWS. The mast is to be provided with a fully penetrated flange which shall be free from any laminations or incursions. The welded connection of the base flange shall be fully developed to the strength of the entire section. The base flange shall be provided with supplementary gussets between bolt holes to ensure elimination of helical stress concentration. For environmental protection of the mast, the entire fabricated mast shall be Hot Dip Galvanized (As per IS-2629) internally and externally, having uniform coating thickness of average 86 microns for bottom / top sections respectively & cerificate from the OEM regarding the same to be submitted along with the PV & test certificates.

2

-

-

... More
(b) An adequate door opening shall be provided at the base of the mast. The opening shall be such that it permits clear access to equipments like winch, cable, wire rope, plug & socket etc. and also facilitates easy removal of the winch for servicing. The door opening shall be complete with a close fitting vandal resistant allen key locking with provision for external lock. The door opening shall be carefully designed and reinforced with adequate steel section so that the mast section at the base is unaffected, and undue buckling of the cut portion is prevented under heavy wind condition. (c) Mast structure shall sustain an assumed maximum reaction arising from wind speed as per IS-875 (Part 3) 1987 (three seconds) which is measured at a height of 10 mtrs above ground level. (d) The high mast shall be provided with accessories which include a raising and lowering system (R & L), trailing cable, power tool, lighting finial and aviation obstruction warning light. (e) The wire ropes shall be of stainless steel grade AISI 304 with minimum 6mm diameter and 7/19 construction. Its central cores shall be also SS and have a minimum breaking strength of 2400 Kgs. The power tool shall be integral type suitable for handling the total head load. It shall have a mechanical torque limiter to ensure safety and also a manual handle shall be provided.

-

-

-

... More
(f) Earthing 4 Nos (02 for FP Box and 02 for High Mast) complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made out of 8 mm dia round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. (g) Earthing 1 No ( for Surge protection device ) complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with

-

-

-

... More
suitable handle made out of 8 mm dia round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. (h) The light luminaries shall be 160 W LED, CT =5700 K made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy 110 lumens/Watt, power factor / 0.90, operating range – 140 to 270 V, 50 Hz including appropriate fixing arrangement complete all as per the recommendations & as directed. (j) The aviation obstruction light shall be LED type with IP 65/66 protection & all as per the recommendations of the OEM complete.

-

-

-

... More
(k) LT feeder pillar box both side openable with projected globe roof for rain water protection, manufactured by a CPRI approved manufacturer dust and vermin proof, suitable for 440 Volt 3 Phase, 4 wire system made out of 3.15mm thick CRCA sheet of size as per OEM and built upon rigid frame work having front and rear hinged double shutter doors with neoprene rubber gasket, epoxy powder coated including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeded with 50 X 50 X 6 mm mild steel angle iron frame complete with PCC foundation in cement concrete 1:2:4 (20 mm graded stone aggregate) and testing after installation complete all as specified and comprising of the following:- (i) Aluminium busbar 100 Amp, supported with suitable size of heavy duty porcelain stand lock with suitable size brass nut, bolts and washers with heat shrinkable PVC sleeving. The bus bar shall be colour coded (Red, Yellow and Blue) for 3 phase and black for neutral.

-

-

-

... More
(ii) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 18 KA of rating 40A - 1 Nos. (iii) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 18 KA of rating 32A - 2 Nos. (iv) Digital Ammeter 0-100 Amps with 3 Nos CT's and 01 No. Selector switch and protection fuse - 01 Set. (v) Digital volt meter 0-500 Volt with 1 No. Selector switch and protection fuse. (vi) LED indicating lamps (3 Nos) with holder for main supply indicating RYB - 01 Set (vii) Astro Timer switch with 3 pole 415 Volt, with coil operating voltage 230 Volt Contactor with and including fuse protection for automatic ON/OFF of security / street lighting - 01 Set

-

-

-

... More
(viii) Contractor MNX 32, 3 Phase, 3 pole 415 Volt with coil operating voltage 230 volt - 02 Nos with 02 Nos push button switch 16 amps and electrical interlocking between two contractors for forward and reverse operation of motor installed at high mast system. (ix) Connector/Terminal set 16-50 Sqmm 5 pole fitted inside the mast for cable connection complete. (x) Surge Protection Device type 2 ,40KA , 3P+N, 2 module with 01 No 32 Amps MCB TPN including internal connection done by using suitable size of copper wire complete all as specified and directed. NOTE : 1) Design / drawing / BOM of the High Mast Light showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
S&F, IP 65, Class I, energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium 25W or next higher rating post top lantern with high power LEDs as light sourse with CT=5700 K intergrated type with luminaire efficiancy 95 lumens/watt, power factor =0.90, operating range-140 to 270 V, 50Hz fixedon & including required length, suitable size light grade pipe incl necessaryfoundation, coping, earthwork (if any) etc. complete with all accessories internally prewired and including connecting upwith and including three core twisted flexible copper conductor cable of suitable size from junction box to fitting all as specified and as directed.( For main gate, rear gate & offrs mess)

8

-

-

... More
S&F, IP 65, Class I, energy saving, environment friendly, long life aesthetically designed with diffused lighting, spun aluminium 8 W or next higher rating lanscope luminaire (Garden lightfitting) of size 1000mm with high power LEDs as light sourse with CT=5700 K intergrated type with luminaire efficiancy 95 lumens/watt, power factor =0.90, operating range-140 to 270 V, 50Hz with necessary fixing arrangements incl coping, earthwork (if any) etc. complete with all accessories internally prewired and including connecting up with and including three core twisted flexible copper conductor cable of suitable size from junction box to fitting all as specified and as directed.( For Adm Bldg & Offrs Mess).

20

-

-

... More
S&F energy saving & environment friendly, long life 200 W, CT=5700 K, LED flood light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with intergrated type with high efficiancy electronic driver, built-in surge suppressor /SPD of 10 KV or more & high brightness LEDs, luminaire efficiancy 110 lumens/watt, power factor =0.90, operating range-140 to 270 V, 50Hz complete incl suitable fixing arrangements on steel tubular poles complete all as specified and as directed by engr-in-charge..( For lighting of volley ball, basket ball & badmintion courts). NOTE: Steel sections required for fabrication of fixing assy for fixing the flood lights on steel tubular poles shall be measured & paid separately under relevant items of the Sch.

32

-

-

... More
Sub total

-

-

-

... More
SEWAGE DISPOSAL (Sch 'A' Part-VII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 14,92,446.94 inserted by the MES in Schedule ‘A’ Part-VII.

1

-

-

... More
SEWAGE DISPOSAL (Sch 'A' Part-VII (A) (MISC))

-

-

-

... More
M&L 150 mm outer dia DWCPE (SN-8) pipes laid in trenches and jointed all as specified and as directed.

1600

-

-

... More
M&L 200 mm outer dia DWCPE (SN-8) pipes laid in trenches and jointed all as specified and as directed.

1000

-

-

... More
M&L 300 mm outer dia DWCPE (SN-8) pipes laid in trenches and jointed all as specified and as directed.

500

-

-

... More
S & F factory made manhole cover slab of size 580mm and overall size 750 including collars as per IS all as specifiedand as directed.

90

-

-

... More
Sub total

-

-

-

... More
ROAD, PATH & CULVERT (Sch 'A' PART-VIII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(ROAD, PATH & CULVERT )” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,35,50,889.29 inserted by the MES in Schedule ‘A’ Part-VIII.

1

-

-

... More
ROAD, PATH & CULVERT (Sch 'A' PART-VIII (A) (MISC))

-

-

-

... More
Applying evenly primary/tackcoat with cataonic bitumen(RS-I) @ 3.50 kg/10sqm over WBM complete all as specified and directed.

1870

-

-

... More
Applying evenly primary/tackcoat with cataonic bitumen(RS-I) @ 2.50 kg/10sqm over black top surfaces complete all as specified and as directed.

1870

-

-

... More
M&L for paving bituminous premixed aspheltic semi dense concrete 40mm consolidated thickness (minimum) with 5.5% binder content of paving bitumen Gde-VG-30 by weight of total mix, rolled and compacted, mixed in mechanical hot mix plant and pre-mix material laid with mechanical paver, finished including rolling to required gradient and camber with 8 to 12 tonne power roller to required compaction complete all as specified in the relevant clauses of SSR Part-I (2009) complete all as specified and as directed.

1870

-

-

... More
Sub total

-

-

-

... More
AREA DRAINAGE (Sch 'A' Part-IX)

-

-

-

... More
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,14,49,129.00 inserted by the MES in Schedule ‘A’ Part-IX.

1

-

-

... More
SECURITY WALLS & GATE (Sch 'A' Part-X)

-

-

-

... More
Lump sum price worked out by the Contractor for “(SECURITY WALLS & GATE)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,41,14,426.94 inserted by the MES in Schedule ‘A’ Part-X.

1

-

-

... More
SITE DEVELOPMENT (PCC BLOCK TOE WALL 1.0 MTR HEIGHT) (Sch 'A' Part-XI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(SITE DEVELOPMENT (PCC BLOCK TOE WALL 1.0 MTR HEIGHT))” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 23,06,125.92 inserted by the MES in Schedule ‘A’ Part-XI.

1

-

-

... More
AIR CONDITIONING (Sch 'A' Part-XII)

-

-

-

... More
Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 1.5 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and as directed. NOTE : (i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology. (ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates. (iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates. (iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.

1

-

-

... More
Supply, install, testing & commissioning of copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut out & time delay & of capacity 3.0 KVA incl electric connection complete all as specified and as directed.

1

-

-

... More
Sub total

-

-

-

... More
WATER COOLER (Sch 'A' PART-XIII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(WATER COOLER)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.12,826.00 nserted by the MES in Schedule ‘A’ Part-XIII.

1

-

-

... More
WATER COOLER (Sch 'A' PART-XIII (A) (MISC))

-

-

-

... More
Supply, install, testing & commissioning of water cooler storage type, ISI marked, 5 star rated, electric driven 230V, 50 Hz, single phase supply with all internal accessories, stainless steel body & tank, power saving PUF insulation, adjustable cold water thermostat, 10 degree to 25 degree centigrade, auto cut-off facility, over-load protection, stainless steel front panel, extended plastic legs, eco-friendly confirming to relevant IS & power factor shall not be less than 0.85 compressor & approx storage capacity of 40 Ltrs & nominal cooling capacity of 40 Ltrs incl electric & water connection complete all as specified and as directed.

8

-

-

... More
Supply, install, testing & commissioning of water cooler storage type, ISI marked, 5 star rated, electric driven 230V, 50 Hz, single phase supply with all internal accessories, stainless steel body & tank, power saving PUF insulation, adjustable cold water thermostat, 10 degree to 25 degree centigrade, auto cut-off facility, over-load protection, stainless steel front panel, extended plastic legs, eco-friendly confirming to relevant IS & power factor shall not be less than 0.85 compressor & approx storage capacity of 80 Ltrs & nominal cooling capacity of 40 Ltrs incl electric & water connection complete all as specified and as directed.

1

-

-

... More
Supply, install, testing & commissioning of water cooler storage type, ISI marked, 5 star rated, electric driven 230V, 50 Hz, single phase supply with all internal accessories, stainless steel body & tank, power saving PUF insulation, adjustable cold water thermostat, 10 degree to 25 degree centigrade, auto cut-off facility, over-load protection, stainless steel front panel, extended plastic legs, eco-friendly confirming to relevant IS & power factor shall not be less than 0.85 compressor & approx storage capacity of 120 Ltrs & nominal cooling capacity of 60 Ltrs incl electric & water connection complete all as specified and as directed.

2

-

-

... More
Supply, install, testing & commissioning of copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut out & time delay & of capacity 1.0 KVA incl electric connection complete all as specified and as directed.

9

-

-

... More
Supply, install, testing & commissioning of copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut out & time delay & of capacity 2.0 KVA incl electric connection complete all as specified and as directed.

2

-

-

... More
Sub total

-

-

-

... More
REFRIGERATION (Sch 'A' Part-XIV)

-

-

-

... More
Supply, install, testing & commissioning of refrigerator, ISI marked, electric driven, single phase having capacity 300 Ltrs or nearest higher size, frost-free smooth flow type, separate chill compartment with plastic shelves, ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement, working with non-CFC refrigerant & 5 star rated incl electric connection complete all as specified and as directed.

4

-

-

... More
Supply, install, testing & commissioning of refrigerator, ISI marked, electric driven, single phase having capacity 215 Ltrs or nearest higher size, frost-free smooth flow type, separate chill compartment with plastic shelves, ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement, working with non-CFC refrigerant & 5 star rated incl electric connection complete all as specified and as directed.

6

-

-

... More
Supply, install, testing & commissioning of metal top deep freezer, ISI marked, electric driven, single phase having capacity 200 Ltrs or nearest higher size, double door working with non-CFC refrigerant & 5 star rated incl electric connection complete all as specified and as directed.

4

-

-

... More
Supply, install, testing & commissioning of copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut out & time delay & of capacity 1.0 KVA incl electric connection complete all as specified and as directed.

14

-

-

... More
Sub total

-

-

-

... More
LIGHTNING PROTECTION (Sch 'A' PART-XV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-XV Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.77,934.15 nserted by the MES in Schedule ‘A’ Part-XV.

1

-

-

... More
SOLAR HOT WATER (Sch 'A' PART-XVI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(SOLAR HOT WATER)” as listed in Schedule ‘A’ Part-XVI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,52,814.50 nserted by the MES in Schedule ‘A’ Part-XVI.

1

-

-

... More
SOLAR HOT WATER (Sch 'A' Part-XVI(A))

-

-

-

... More
Supply, install, testing and commissioning of "Solar Hot Water System" , Flate Plate Collector type duly coated & made up of aluminium body with with toughened glass, heat exchanger based on indirect transfer of heat, insulated hot water S/S storage tank, air vent & drainage interconnections, circulation piping between systems, collector & hot water tank stand, control valves, temperature gauges etc. of capacity 100 LPD with electrical heating back up complete all as specified & as directed. (Make: EPI/WAREE/KOTAK/URJA/RACOLD (ISI Marked)

1

-

-

... More
Supply, install, testing and commissioning of "Solar Hot Water System" , Flate Plate Collector type duly coated & made up of aluminium body with with toughened glass, heat exchanger based on indirect transfer of heat, insulated hot water S/S storage tank, air vent & drainage interconnections, circulation piping between systems, collector & hot water tank stand, control valves, temperature gauges etc. of capacity 200 LPD with electrical heating back up complete all as specified & as directed.(Make: EPI/WAREE/KOTAK/URJA/RACOLD (ISI Marked)

4

-

-

... More
Supply, install, testing and commissioning of "Solar Hot Water System" , Flate Plate Collector type duly coated & made up of aluminium body with with toughened glass, heat exchanger based on indirect transfer of heat, insulated hot water S/S storage tank, air vent & drainage interconnections, circulation piping between systems, collector & hot water tank stand, control valves, temperature gauges etc. of capacity 300 LPD with electrical heating back up complete all as specified & as directed.(Make: EPI/WAREE/KOTAK/URJA/RACOLD (ISI Marked)

5

-

-

... More
Sub total

-

-

-

... More
PRIME COST SUM ITEMS (Sch 'A' PART-XVII)

-

-

-

... More
multi stage submersible pump set (Open well type )

-

-

-

... More
Supply, install, testing and commissioning of multi stage submersible pump set (Open well type ) of capacity not less than 12.5 HP with bronze impeller, directly coupled with motor, suitable for minimum total head 60 meter and discharge min 450 LPM operated on AC 3 phase, voltage range 300V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft / motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron complete all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. (1W + 1S) *Add / Deduct ________ % (_______________ percentage) Rs. ___________________ * Above / Below SSR-2010 including all over head profit.

2

-

-

... More
pumping set, horizontal end suction centrifugal type

-

-

-

... More
Supply and Install pumping set, horizontal end suction centrifugal type confirming to IS-12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with non-over loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 40 m head & minimum 450 LPM discharge complete including suitable steel frame, PCC platform / foundation etc. The pump and motor shall comply to all the requirements of relevant IS. (1W + 1S) *Add / Deduct ________ % (_______________ percentage) Rs. ___________________ * Above / Below SSR-2010 including all over head profit.

2

-

-

... More
Iron Removal Cum Pressure Filtration plant of 6000 GPH capacity

-

-

-

... More
Supply, install testing & commissioning of Iron Removal Cum Pressure Filtration plant of 6000 GPH capacity complete with pressure filter, catalytic media, air compressor, back washing facility, pipelines, valves, pressure gauges, sampling cocks etc. including suitable civil platform with RCC foundation. NOTE: 1) Design / drawing / BOM of the IRP cum filtration plant incl foundation details showing the dimensions is to be obtained from OEM / Auth Supplier strictly keeping in view the actual Borewell Yield & the capacity / size of Submersible & Centrifugal Pumping Sets selected & the same is to be got approved from GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working of the plant is deemed to be included in the quoted rates. *Add / Deduct ________ % (_______________ percentage) Rs. ___________________ * Above / Below SSR-2010 including all over head profit.

1

-

-

... More
STP

-

-

-

... More
Supply, Install, Testing and commissioning of Package Sewage Treatment Plant of capacity 50000 LPD with FRP based septic Tank along with fixed film aeration tank -01 No, Sludge Removal Pump-01 No, Air blower - 02 Nos, Control Panel, Chlorination unit incl all connecting piping network and all other accessories as per OEM including all necessary civil work for installation complete as per relevant IS & WHO norms as applicable. NOTE: 1) Design / drawing / BOM of the Sewage Treatment plant incl foundation details showing the dimensions is to be obtained from OEM / Auth Supplier strictly keeping in view the actual ground/site requirement & the same is to be got approved from GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working of the plant is deemed to be included in the quoted rates. 3) The contractor is required to visit the site prior to quoting of the subject item so as to ascertain the actual ground requirement w.r.t. foundation, disposal etc. issues. Any further query at a later date shall not be entertained & responsibility of the same shall rest with the contractor. 4) The package sewage treatment plant shall only be procured from ISO 9001, ISO 14001 & OHSAS 18001 certified manufacturing facilities/ OEMs. 5) The quoted rate shall be deemed to be inclusive of the mandatory factory testing of the package sewage treatment plant before dispatch. *Add / Deduct ________ % (_______________ percentage) Rs. ___________________ * Above / Below SSR-2010 including all over head profit.

1

-

-

... More
Construction of Hard standing for Vehs complete all as specified and shown on drawing. *Add / Deduct ________ % (_______________ percentage) Rs. ___________________ * Above / Below SSR-2010 including all over head profit.

1

-

-

... More
Sub total

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.