Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 30,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_279355_1Bid Award Id
ViewTender No
80380Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repair/maintenance of fire fighting pump house at Kautilya Auditorium and INHS Navjivini Hospital including repair/maintenance of fire detection and fire alarm system at INA Ezhimala
Repair/maintenance of fire fighting pump house at Kautilya Auditorium and INHS Navjivini Hospital including repair/maintenance of fire detection and fire alarm system at INA Ezhimala
Repair/maintenance of fire fighting pump house at Kautilya Auditorium and INHS Navjivini Hospital including repair/maintenance of fire detection and fire alarm system at INA Ezhimala
BOQ Items
Pump coupled to 15HP/11KW (Make: Kirloskar, Model-KDT 1598+)
2
-
-
Servicing of diesel engine driven high pressure fire pump of following capacity at Fire Pump House at INA Ezhimala by servicing all accessories PT pump injectors, wood ward governor, self starter, Radiator, dynamo, engine wiring, terminal contacts and safety controls etc., including replacement of spare parts as required (spare parts shall be measured and paid separately under relevant items) and reassembling sub assemblies after carrying out necessary repairs and painting with one coat of synthetic enamel paint testing, commissioning as directed by Engineer-in-Charge. Make : Kirlosker:
-
-
-
108BHP capacity Diesel engine
1
-
-
38 BHP capacity Diesel engine
1
-
-
Material and labour for refilling fire extinguisher for following type and capacity complete all as directed by Engineer-in-Charge :-
-
-
-
DCP stored pressure - 5 Kg capacity
15
-
-
DCP stored pressure - 9 kg capacity
5
-
-
CO2 - 2Kg capacity
20
-
-
CO2 - 4.5Kg capacity
20
-
-
AFFF foam - 9 liters capacity
10
-
-
Preparing surfaces of fire hydrant pipe line up to 150mm dia by scrapping old rusted paint with and including applying two coats of synthetic enamel paint of fire red colour over one coat of red oxide primer including marking fire hydrant flow complete all as directed by Engineer-in-Charge
500
-
-
Taking down carefully electric motor 3phase, 415v, 50Hz, AC from foundation/coupling, transporting to civil workshop, opening motor, checking insulation value of the windings, insulating the winding with same class of insulation, painting with one coat of synthetic enamel paint as per color code and tranporting back to site for re-installing motor and connecting to pump, testing the motor for satisfactory performance complete all as directed by Engineer-in-Charge for the following capacity :-
-
-
-
40HP/30KW
1
-
-
15HP/11KW
1
-
-
S&F addressable control module including taking down old unserviceable item complete all as directed by Engineer-in-Charge. Make : Honeywell/Notifier
2
-
-
S&F addressable input module including taking down old unserviceable item complete all as directed by Engineer-in-Charge. Make : Honeywell/Notifier
1
-
-
S&F addressable monitor module for beam detector including taking down old unserviceable item complete all as directed by Engineer-in-Charge. Make : Honeywell/Notifier
1
-
-
S&F addressable short circuit isolator including taking down old unserviceable item complete all as directed by Engineer-in-Charge. Make : Honeywell/Notifier
1
-
-
S&F Dial type pressure gauge (4"Dia) (Firebug) 0-21 kgs including taking down old unserviceable item acomplete all as directed by Engineer-in-Charge.
5
-
-
S&F Single pressure switch, universal type to suit the system including taking down old unserviceable item acomplete all as directed by Engineer-in-Charge.
5
-
-
S&F Air release valve 25mm dia including taking down old unserviceable item complete all as directed by Engineer-in-Charge.
20
-
-
Replacement of Gun metal fire Hydrant valve with 5mm flanged inlet and 63 mm female single instantaneous outlet complete with Lug & Chain as per IS-5290 Hydrostatically tested to 21 Kgf/cm2 of pressure having a flow rate of 900 LPM at 7Kgf/m2 complete all as directed by Engineer-in-Charge.
5
-
-
Replacement of fire hose 63 mm dia confirming to IS: 636, 30 meter length including gunmetal heavy duty pair of male and female couplings complete all as directed by Engineer-in-Charge.
25
-
-
Replacement of gunmetal branch pipe with male threaded nozzle of 15mm and male instantaneous inlet of 63 mm dia as per IS : 903.93 complete all as directed by Engineer-in-Charge.
27
-
-
Supply and fix butterfly valve 100mm slim seal standard lever operated type confirming to IS: 13039 complete all as directed by Engineer-in-Charge.
4
-
-
Preparing surfaces of fire control cabinet out door type of size 0.50mX 0.50mX0.30m by scrapping out old rusted paint and necessary snickering and applying two coats of synthetic enamel paint over one coat red oxide primer by spray painting complete all as directed by Engineer-in-Charge.
10
-
-
Repair of microprocesser based fire alarm control panel NOTIFIRE FS 3030, having six loop data card, battery, LCD panel, buzzers required software program etc, including testing all as directed.
Note: The unit rate quoted shall include for regular inspection, once in a month maintenance/servicing of loop wiring, heat / smoke detectors, response indicator, MCP, sounder cum scob with control module complete all as directed by Engineer-in-Charge.
3
-
-
Supply and fix multi criteria detectors with base for below for false ceiling model FAPT 851B501 including taking down old unserviceable complete all as directed by Engineer-in-Charge. Make : Honey well or Equivalent
26
-
-
Supply and fix manual call point resettable type complete all as directed by Engineer-in-Charge. Make : Honey well or equivalent
8
-
-
Supply and fix sounder cum storb with control module with taking out old unserviceable acomplete all as directed by Engineer-in-Charge.
Make : Honey well or equivalent
10
-
-
Supply and fix Sprinkler with taking out old unserviceable complete all as directed by Engineer-in-Charge.
Make : Honey well or equivalent
10
-
-
Painting to valve chamber and cast iron cover with synthetic enamel paint of fire red colour including marking with white colour paint complete all as directed by Engineer-in-Charge.
10
-
-
Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in hard/dense soil including trimming the sides and forming bottom surface to required levels for laying pipes complete all as specified and as directed.
10
-
-
Returning, filling in including spreafing, levelling, watering and well ramming in trenches with soil obtained from excavation in layers n.exc. 25 cm complete all as specified and as directed.
5
-
-
Removing surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
5
-
-
Supply and replace rubber bush for pump coupling suitable for the following capacity of pumps
-
-
-
75KW/100HP motor
4
-
-
15HP/11KW motor
4
-
-
Repairs to CI sluice valves by taking out gland sleeve, check nut spindle, gate etc. and cleaning the valve by removing all scales and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint all as directed by the Engineer-in-Charge for the following:
-
-
-
Sluice valve flanged type 200/ 150mm dia.
4
-
-
Sluice valve flanged type 100/ 80mm dia.
4
-
-
Repairs to CI Non return valves by opening the cover and cleaning the valve by removing all scales, dirt etc and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint all as directed by the Engineer-in-Charge for the following:
-
-
-
Non return valve flanged type 150/100/80 mm dia.
2
-
-
Material & lab our for attending breakdown of 150 mm dia pipe line bursting/cracks including broken pipe pieces of various sizes through gas cutting or manual cutting as required at site and providing new CI/MS/GI pipes of required length (not more than 2m) and removing out the damaged CI pipe and inserting necessary specials such as flanges etc as required at site including testing for the leakages of flange joints for 150mm dia MS/CI pipes complete all as specified and directed by Engr-in -charge Note:Excavation and earth work shall be measured and paid seperately under relevant item of this BOQ.
2
-
-
Material and labour for replacement of glass panel for indoor fire hydrent boxes as per site requirement by taking down old broken glass as specified and directed by Engr-in-Charge.
5
-
-
S&F 25 mm brass ball valve for hose real inside Fire hydrant box by taking down old unserviceable item complete all as directed by Engineer-in-Charge.
5
-
-
Supply and fill engine oil
50
-
-
Supply and fill coolant
20
-
-
Supply and fix fan belt for 40/100HP DG pump set
2
-
-
Supply and fix fuel filter40/100HP DG pump set
4
-
-
Supply and fix Oil filter40/100HP DG pump set
2
-
-
Supply and fix air filter40/100HP DG pump set
2
-
-
Supply and replace nut, bolt and washer in repairs of any size
0.25
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements