Ajmer Vidyut Vitran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,08,81,780Document Cost
₹ 2,950Tender Fee
₹ 1,180
Summary
Ajd/se/tw/nathdwara/tn-392
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_AVVNL_167739_1Bid Award Id
ViewTender No
AJD/SE/TW/NATHDWARA/TN-392Tender Authority
Ajmer Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://125.21.165.41/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Add Cost: in case providing A Class bricks
250
-
175
Add cost in case of using 200 mm HDPE - DWC pipe (IS-14930)
1000
-
178.2
Supply of 33 KV XLPE Underground Cable without road cutting i.e. through burrowing machine"vermier"(120 cm deep). Use of this techonology must be restricted to the situation like:-
(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.
(ii) When the road cutting is not permitted by the local administration.
-
-
-
Supply of Cable - 33KV XLPE underground cable (AL. conductor) - 3 x 300 sq mm
8000
-
1951.37
Add cost in case of using 200 mm HDPE - DWC pipe (IS-14930)
8000
-
178.2
Supply of 33 kV (XLPE) termination kit / Straight through (ST) joints (Making Outdoor/ Indoor Joint) (Heat Shrinkable type) As Per Manufactures Kit Guidance And Direction Including Preparation Of Cable and Testing, refilling, etc. as required (including crimping of lugs).
-
-
-
i) Outdoor end terminal - 3 x 300 sq mm
8
-
3562.78
i) Straight through joint 3 x 300 Sq mm
10
-
10105.95
11 KV UNDERGROUND CABLE including ROAD-CROSSING CABLE Work:
-
-
-
Supply of two (D/C) 11KV XLPE underground cable (AL. conductor) w/o overlapping as per relevant IS/AVVNL standards including excavation of 50 cm width x 120 cm deep trench in Kaccha land, 25 cm thick under layer of sand.'A' class bricks or pipe covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30 mtr of cable and at every turn
-
-
-
Supply of Cable - 11 KV XLPE underground cable (AL. conductor) - 3 x 185 sq mm
70000
-
956.8
Supply of Cable - 11 KV XLPE underground cable (AL. conductor) - 3 x 70 sq mm
7000
-
625.26
Add Cost: in case providing A Class bricks
1000
-
175
Add cost in case of using 200 mm HDPE - DWC pipe (IS-14930)
37500
-
178.2
Supply of 11 kv XLPE underground Cable without road cutting i.e. through burrowing machine"vermier"(120 cm deep). Use of this techonology must be restricted to the situation like:-
(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.
(ii) When the road cutting is not permitted by the local administration.
-
-
-
Supply of Cable - 11 KV XLPE underground cable (AL. conductor) - 3 x 185 sq mm
8000
-
956.8
Add cost in case of using 200 mm HDPE - DWC pipe (IS-14930)
8000
-
178.2
Supply of cable termination / straight through joints on 11 kV (XLPE) Aluminium conductor underground Cable with Outdoor/ Indoor termination end and/or straight through joint including required excavation/ removal/ fixing/ testing, etc. as required
-
-
-
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
240
-
801.17
XLPE 3X185 SQ.MM H.S. ON INDOOR TYPE
1000
-
766
XLPE 3X185 SQ.MM H.S. ST TYPE
500
-
2298
XLPE 3X70 SQ.MM H.S. ON OUTDOOR TYPE
40
-
788.14
XLPE 3X70 SQ.MM H.S. ON INDOOR TYPE
120
-
766
XLPE 3X70 SQ.MM H.S. ST TYPE
20
-
2252.4
LT UG CABLE WORKS.(Incl. LT Cable road-crossings).
-
-
-
Supply & Laying of LT XLPE Insulated and PVC Sheated Armoured underground cable as per relevant IS/AVVNL standards including excavation of 30 cm width x 120 cm deep trench in Kaccha land,25 cm thick under layer of sand.'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30 mtr of cable and at every turn
-
-
-
4 C x 185 sq. mm
192000
-
601.21
4 C x 70 sq. mm
1000
-
290.22
Add Cost: in case providing A Class bricks
1000
-
100
Add cost in case of using 200 mm HDPE - DWC pipe (IS-14930)
192000
-
178.2
Supply of LT XLPE Insulated and PVC Sheated Armoured underground Cable without road cutting i.e. through burrowing machine"vermier"(120 cm deep). Use of this techonology must be restricted to the situation like:-
(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.
(ii) When the road cutting is not permitted by the local administration.
-
-
-
4 C x 185 sq. mm
7218
-
601.21
Add cost in case of using 200 mm HDPE - DWC pipe (IS-14930)
7218
-
178.2
Supply of cable termination / straight through joints on LT XLPE Insulated & PVC sheathed underground Cable with Outdoor/ Indoor straight through joint including required excavation/ removal/ fixing/ testing, etc. as required
-
-
-
LT XLPE Insulated and PVC Sheated Armoured Cable 4C x 70 sq mm to 4C x 185 ss mm - ST TYPE
38
-
2298
LT Works
-
-
-
Supply of LT supply distribution kiosk as per specification of Nigam, Brick masonary using cement mortar of ratio 1: 6. The work includes supply of brick & cement mortar by the contractor
-
-
-
LT supply distribution kiosk 200 Amp. suitable for distribution as per Nigam drawing/specifications
2000
-
24426
Supply of LT Distribution piller Boxes of 400 Amps. Capacity.Each 37"x24" base as per AVVNL standard including excavation,bricks,sand,cement masonary of size 4"x3"x10"and 3' in ground and 1 1/2'above road level with muffing to support and mounting the piller .Themasonary will have 4" X 4" opening 2"below ground level two in the rear sideand one each in the remaining sides to facilitate entry and exist of incomingand outgoing PVC cable.Earthing of the piller shall be connected to DP earth with 7/10 SWG StayWire & lugs.
39
-
33166.02
Supply of HD Galvanised M.S.Rod type earthing set made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire 15 meter long (for earthing of 11 KV & LT line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure/ Distribution Box/ Feeder Piller Box/ RMU & earth wire etc.
3500
-
686.55
Supply of service line LT PVC Insulated and PVC Sheathed armoured underground cable with proper connection to MCCB fixed in LT Distribution box to consumer meter location through underground trench as per relevant IS/ Specification using G.I./HDPE Pipe from service mains in LT Distribution box to Meter Box terminals using lugs/crimping pins at both ends. The work includes connecting the armour wire with meter box & earth of distribution lines with suitable clamps for proper earthing of the cable. The Armoured XLPE cable hooked to supporting pipeor MS Angle through anchor hook must be fixed on wall and with proper clamp up to meter box at an interval of 1 meter.
-
-
-
4C - 50 Sq mm
5000
-
237.83
4C - 16 Sq mm
17500
-
93.72
2C x 4 Sq mm
230000
-
43.37
Add cost in case of using 40 mm HDPE - DWC pipe (IS-14930)
252500
-
63.72
RMU Infra
-
-
-
RMU and associated works: As per the Technical Specification mentioned (Technical Specification of ring main unit fully Motorized and SCADA compatible as per Tender Specification)
-
-
-
Supply of outdoor type RMU with necessary take off terminal units for future automations contains two numbers load break isolators, one number breaker and associated accessories, equipments, (excluding civil works and earthing ) the FPI shall be integral part of each RMU and shall be capable of indicating the fault. (2LBS+1VCB)
92
-
381621.32
Supply of extensible outdoor type Load break Isolators for extension and associated accessories, with necessary take off terminal units for future automations. (excluding civil works and earthing).
25
-
158961.83
Supply of extensible outdoor type Distribution Transformer Breakers for extension with necessary take off terminal units for future automations. (excluding civil works and earthing).
54
-
245005.48
Pipe Earthing for Power Transformer / 11 KV RMU :-
Supply of earthing electrode shall consist of G.I. Pipe 100 mm, of 3 Mtr. Length. The electrode shall be buried as far as practicable 3 Meters below ground level. Wherever possible earth electrodes shall be located as near the water tap, water drain or near down take pipe. Earth electrodes shall not be installed in proximity to a metal fance. It shall be kept clear of the bulidings foundations and in no case it shall be nearer than 2 Mtr. from the outer face of the wall. The electrode shall be surrounded with layer of charcoal dust and salt mixture through out the length. The 100 mm G.I. pipe shall be provided with holes of 12 mm Dia drilled at 75mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a G.I. threaded cap for watering the earth through a pipe. A clamp with pati of 12" of M.S. Flat of size 50x6 mm shall be fixed (Bolted) on the top age of the pipe which in turn shall be connected Neutral/Body of the Power Transformer/ RMU through M.S. Flat size 50x6 mm. The G.I. cap over the G.I. Pipe shall be housed in a masonry chamber, approximately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC Inspection cover resting over a RCC frame, embedded in masonry. (supply item included in erection) (Only Erection)
400
-
834.91
Supply of M.S. flat 50x6 mm for earthing of transformer & RMU
3
-
61743.5
Supply of Modified 2-Pole / 4-Pole Distribution Transformer Structure with the provision for collection & discharge of oil from transformer’s seating to ground thro G I pipe & sump tray under DT. excluding civil work (as per Approved Drawing)
-
-
-
2-pole DT Transformer Structure
68
-
32500.28
4-Pole DT Transformer Structure
23
-
41186.39