If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

UP Jal Nigam - UPJN Tender

Works
Eprocure

Opening Date

1 Feb 2019

Closing Date

22 Feb 2019

Tender Amount

₹ 35,00,00,000 
Notes
Download

Costs

Summary

Lalitpur Water Supply Reorgnization Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Electric Power Substation Building near Intake Well Site /Water Works Campus - Const of electric power sub station buiding as per Dept Design and Drawing.( Metre Room Size -3mx3m ,HT room 5 x 5.73 , LT room- 4x5.730, open space for transformer 7x 5.73 , 2 nos of blocks 1.5 m x 1.5 m x 1 m , height of substation 4 m) Provisions also include Concrete with 40 mm gauge stone ballast sand and cement in 8:4:1 in foundation including supply of all material labour T&P etc. Complete.Coarse stone masonary in 1:6 cement and local sand mortar in foundation and plinth including supply of all material labour T&P. etc. complete. 12 mm thick plaster with cement and fine sand in 1:6 over brick minimum thickness not to be less than 10 mm including supply of all material labour T&P etc. complete . Raised Pointing over stone masonary with cement and coarse sand in ratio 1:2 including supply of all material labour T&P etc. complete. Earth filling in plinth including supply of earth filling, watering & ramming etc. M.S. Rolling shutter gate with fram including Fabrication and all material, labour and T&P etc. complete. Supply and fixing angle iron frame for door windows shutters including supply and fixing and adjustment of hinges bolts. hooks & handles springs and other fit things including supply of all fittings as per requirement. Painting on new iron work with one coat of Primer and two coats of approved enamal paints including supply or materials labour T&P. Apporved apex paints in 2 coats including supply of all material labour and T&P etc as per requirement.

2

-

1068750

... More
Water Treatment Plant (10 MLD) Survey, hydraulic and Structural Design of treatment plant from reputed university in R.C.C. grade not less than M-25 and supply of all materials, T&P etc. complete required for construction of civil works and installation of mechanical equipments for 10 MLD treatment plant (based on latest technology) consisting of inlet chamber, alum dosing chamber hydraulic jump mixers flocculation chambers, hopper bottom settling tanks with provision of hydraulic desludging, rapid sand filters under drainage system back wash tank, air blower and waste water sump to recycle waste water with pumping plants including all pipes and appurtement works, sewer system for disposed of waste water and sludge etc., laboratory of size 3.0 Mtrs. x 5.0 Mtrs. Size with attendant room of size 3.0 Mtrs. x 2.5 Mtrs. Size to accommodate water sample testing equipments, installation of suitable mechanical devices i.e. blowers clear water auto control device including the required pipe specials and fitting errection commissioning and testing all complete as per direction of Engineer in charge. Provisions also include Ultimate clear water demand per day 9.18 mld,Working hours of treatment plant -20 Hrs,Designed out put rate of flow of clear water from treatment plant (for 20 hours working ) -12mld, Designed input rate of raw water in treatment plant (for 20 hours working ) -12.6mld.The minimum mix for all the R.C.C. works shall be M-25. or As per IS 456:2000 and IS 3370 (part 1-4) and its latest revisions.Quote rate taking into account that foundation has to rest on firm and stable strata of soil. Soil testing will be conducted by contractor.All the hydraulic and structural design with drawings shall be supplied by the contractor at his own cost. The works shall be executed as per the approval of the hydraulic and structural design with drawings from the competent authorities of the Jal nigam.Supply and installation of pressure gauges and flow gauges of standard ‘Make’ as approved by the department suitable for the filtration unit including its satisfactory testing and supply and fixing of all accessories required for proper working. Wiring with 1.50 mm2 Copper conductor running with (25 mm dia PVC conduct pipe concealed in slabs & walls etc. including fixing of required M.S. boxes, Mica sheet & Switches & Sockets etc. including suitable nos of 5 amp plug point and 5 amp light points.2.5 mm2 copper conductor including 15 Amp Power Point and Exhaust Point.Supply & fixing of following including proper connections with wiring on boards etc. complete,150 watt sodium vapor lamps complete,Tube lights complete. (1 x 40 watt.), C.F.Ls. 15 watt. Main Switch 32 Amp. along with box etc.Frames for doors shall be made 50x50x5 mm M.S. angle iron and ionized and shall be partly panel and glazed made of suitable steel sections, confirming to ISI. Painting of all concrete surface with three coats of approved apex paint, painting of pipes, doors, windows with anticorrosive paints including laying jointing and fixing of suitable size of D.I.D/F pipes, specials and CIDF sluice valves ,desludging valve as directed by the engineer required for inlet pipe, disludging pipe and wash out pipes including supply of ISI marked D.I.D/F pipes and Kirloskar C.I.D/F sluice valve specials and all jointing materials such as nut, bolts, rubber insertion etc. supply and fixing of sluice gates of standard make wherever required to regulate the flow of water in raw water channel; supply and proper fixing or grouting.

1

-

54000000

... More
CONSTRUCTION OF R.C.C C.W.R. 1000 KL CUM PUMP HOUSE Design supply of all material T&P etc. and construction of following sizes under ground semi sunk clear water reservoir cum pump houses at a safe bearing capacity of 8 ton /sqm on seismic proof design & drawing provided by contractors, duly approved by the department and as per details given in scope of work.All other details of C.W.R. not covered here shall also be as per specifications and relevant IS code capacity of C.W.R.'s as follows 1 nos. 1000 K.L. at water works campus. Provisions included in above worksSubmission of detailed design, soil testing and drawing of C.W.R. cum Pump House from any recognised University or as per direction of Engineer in-charge.The minimum mix for all the R.C.C. works shall be M-25. or As per IS 456:2000 and IS 3370 (part 1-4) and its latest revisions.The lower surface of the raft foundation shall rest on 10mm thick P.C.C. 1:4:8 compacted properly with cement; coarse sand & stone ballast 40mm gauge. Framed structure for pump house is to be provided above CWR with minimum 12m x8 mx4 m dimension to accommodate pumping plants, control panels with cable trenches. The floor of pump sump is to be kept minimum 50 cm. below to provide V.T pumps. The floor will be sloping as per standards laid down in water supply manual. Columns of the pump house shall be provided for gantry girders. Sufficient no. of windows shall be provided with 'Z' section partly fixed and partly open able. Flush doors of approved qualities shall be provided in doors. The Pump house floor shall be finished with 50 mm thick ironite flooring laid in panels. Cable trenches shall be provided as per requirement. Free board is to be kept minimum 30 cm. in C.W.R. Parapet wall is to be kept 30 cm. above pump house roof. Sufficient number of drain pipes (rain water) of cast Iron of reasonable dia shall be provided. Supply of all materials, labour, T&P etc. Painting of all concrete surface with three coats of approved apex paint and painting all exposed surface of steel works such as railing, ladders, ventilator, manhole cover, inlet outlet, washout and overflow pipe etc. painted with a coat of metal primer and after this two coats of approved quality paint. M.S. ladder duly painted of designed size shall be provided in C.W.R. 600mmx600mm size MS manhole cover with locking arrangement fitted with 50x50x6mm angle iron embedded in concrete in the roof of C.W.R. at appropriate place. The thickness of cover of manhole shall not be less than 4mm and shall be provided with overlap 1200mm dia ventilator is to be constructed at CWR roof. Angle iron 40x40x5mm posts eight nos. embedded properly in concrete with fly mosquito proof mesh of size 3mm over 20mm sq. expended metal jali of all around the angle irons with arrangement to cover it with metal sheet at top. Suitable size of over flow pipe should be provided including proper drainage arrangement. R.C.C. Plateform (Splashing Pad) is to be constructed to encounter the force of water falling on floor of C.W.R. so as to save it against scouring or damage in the floor. Appoxy paint is to be painted on free board area and bottom of the roof area of C.W.R .Plaster and Brick work in pump house shall be with 1:4 cement, sand mortar . Sunshade are to be provided in 50 cm. width at each and every window where as 1.2 m width of sunshade is to be provided at main entrance gate of Pump House. Separate doors is to be provided for chlorinating room with mechanically operated shutter with unloading arrangement of Chlorine cylinders and other T&P. All inlet & overflow pipe of suitable size shall be grouted in wall of C.W.R. at required leve l. Clearance of site before and after completion of the work as per direction of Engineer-in-charge.

1

-

6750000

... More
RCC Over Head Tank At Nehru Nagar Zone 1800 Kl/20 m and At Chandmari Zone 1200Kl/22m Design & construction of following capacities of R.C.C. (Intz type) Over Head Tank at a staging shown against each at locations shown in scope of work with foundation depth 2.5 m below ground level and at a safe bearing capacity of soil 8 ton/m2 on pile /Raft foundation to be for decided after the actual soil bearing capacity test to be got conducted by the contractor as per details given in scope of work. Capacity of O.H.T 1800 KL/20 M and 1200 KL /22m STAGING Provisions included in above works Submission of detailed design and drawing from any recognized University or as per direction of Engineer in-charge The lower surface of the raft foundation shall rest on 10mm thick P.C.C. 1:4:8 compacted properly with cement; coarse sand & stone ballast 40mm gauge according. One meter wide balcony around the tank at the middle ring beam level. One meter wide stair case, supported on two RCC columns attached with the tank body as an access to balcony and top dome of the tank from made up ground level up to top dome having landing 1 to 1.25m long at vertical intervals in between 2 to 3 mt. Rise and tread of steps around 15 and 25 cms respectively. One meter wide gate with a cage of 2 M high at first landing shall be provided in stair case as per direction of Engineer-in-charge. G.I. pipe (medium), 20mm dia ISI marked, railing around both edges of the seprate double piller stair case with cap gate from ground level to the top dome and all around the outer perimeter of the balcony in three rows fastened to angle iron posts embedding into the concrete steps or to be fixed by two vertically fitted bolts grouted at the time of concreting. The clear height of angle iron post from top of the concrete surface shall be 1.25mt. The angle iron posts shall be of size 50x50x6mm placed 1 to 1.5mts horizontally the top of the angle iron posts finished smoothly. Aluminium ladder 60cm. Wide from manhole upto top of the bottom dome inside the tank body made up of aluminium section of size 65x65x6mm and 20mm bars of pipe thickness minimum 6mm 25 cm c/c welded or riveted to the and having side railing of 45 cms in height. The ladder grouted properly in concrete at each and as per direction of Engineer in charge and material for ladder as per latest IS code. 600mmx600mm size MS manhole cover with locking arrangement fitted with 50x50x6mm angle iron embedded in concrete in the top dome manhole at appropriate place. The thickness of cover of manhole shall not be less than 4mm and shall be provided with overlap. 1200mm dia ventilator at the crown of the top dome made up of 40x40x5mm angle iron posts eight nos. embedded properly in concrete with fly mosquito proof mesh of size 3mm over 20mm sq. expended metal jali of all around the angle irons with arrangement to cover it with metal sheet at top. Fixing foot steps 20mm MS flat bars of length 25 cm at 300 mm c/c from the MS manholes to the ventilator of the top dome of tank for maintenance including supply of all materials etc. Provide and fix water level indicator calibrated in metres / cms as per specifications given in tender document. Provide and fix-lightening conductor as per latest IS code and specification given in tender document .Supply and fixing of D.I. double flanged pipes of class K-9 as per requirement and design, The pipes will rest on duck foot bends below the floor of the tank including supply of all materials required for jointing and erecting true to alignment of the columns. The inlet and overflow pipes shall go upto the lower level of free board or H.W.L. while outlet and washout pipes shall go upto L.W.L. inside the tank body. The lower limits of pipe fixing shall be from dome of the tank upto S.V. chambers. The duck foot bends of all the pipes shall be fixed so that pipes rest on the floor. The duck foot bends shall be supported on cement concrete foundation in 1:2:4 below one metre cover. Supply and fixing of clamps to the vertical pipes with MS clamps of size 65x6mm at 2.0m c/c. Supply all materials labor, T&P etc. and provide 1.5m wide apron from the outer face of the columns, all around the floor of over head tank consisting of 40mm thick PCC 1:4:8 with 20mm gauge stone ballast over late on grated stone ballast 40 mm thick in 1:4:8 cement sand mortar. Flooring will also be done in the same day upto the perimeter including all columns of the staging. The apron all around shall be guarded with a single brick on edge laid radially all around it in 1:4 cement, sand mortar. Supply of all materials, labour, T&P etc. and painting all exposed surface of steel works such as railing, ladders, ventilator, manhole cover, inlet outlet, washout and overflow paint over and above a coat of metal primer Supply of all materials, labour, T&P etc. and painting all exposed surface of concrete including bottom face of bottom dome but excluding the surface which is below the ground with 3 coats of approved cement paint. Preferably ISI marked approved by Engineer in charge also including wall writing as specified in specification attached. Filling the tank as many times as required with water and testing the tank for water tightness and marking it watertight.

1

-

27934200

... More
Raw-Water Rising Main From Intake well to Treatment Plant & Clear Water RMs waterworks to zonal OHTs.

-

-

-

... More
Raw-Water Rising Main From Intake well to Treatment Plant & Clear Water RMs waterworks to zonal OHTs. Supply of 450 mm DI K-7 class medium pipes of approved make including railway freight, insurance charges and cartage upto site with required specials etc complete.(intake well to WTP)

3500

-

3771.9

... More
Same as above but for 400 mm DI k-7 pipes (WTP to Nehru Nagar OHT)

3000

-

3276.9

... More
Same as above but for 300 mm DI k-7 pipes (WTP to Chandmari OHT)

5000

-

2153.25

... More
Excavation in soil mixed with moorum single, kankar and bazari for pipe line trenches with lift upto 1.50 m and lead upto 50 m including disposal of surplus earth within a distance of 50 m from center of trenches also including filling back with watering and ramming of excavated earth in to trenches

7200

-

158

... More
Same as above item but excavation in soft rock and similar types

7200

-

649.12

... More
Design Laying, jointing testing and commissioning of Raw /Clear water Rising Mains Carting of 450 mm dia D.I. k-7 pipes( or as per design), specials, jointing materials to the site of work, lowering the same into the trenches, laying true to alignment and gradient into the trenches / under or above the culvert/ above the masonary pillars/ across the nalas, across the existing pipes or as directed by the department, jointing the same, cutting the length of pipes as per site requirement and also including testing of pipe lines to satisfaction of the department and making interconnection as required.

2800

-

271.17

... More
same as above item but for 400 mm DI k-7 pipes

2900

-

224.82

... More
same as above item but for 300 mm DI k-7 pipes

4900

-

150

... More
Supply of 100 mm sizes of scour valves as per I.S. 780-1960 tested to 10Kg/sqm upto site with specials including lowering the same into trenches and fixing in position & jointing the same with supply of jointing material and testing etc complete.(kirloskar make or as per department direction)

6

-

18006

... More
Supply of 450 mm sizes of C.I.D/F PRV as per I.S. 780-1960 tested to 10Kg/sqm upto site with specials including lowering the same into trenches and fixing in position & jointing the same with supply of jointing material and testing etc complete.(kirloskar make or as per department direction)

2

-

55670

... More
Same as item above but for 400 mm size

2

-

46172

... More
Same as item above but for 300 mm size

2

-

41402

... More
Supply of 450 mm sizes of C.I.D/F NRV as per I.S. 780-1960 tested to 10Kg/sqm upto sitewith specials including lowering the same into trenches and fixing in position & jointing the same with supply of jointing material and testing etc complete.(kirloskar make or as per department direction)

2

-

319800

... More
Same as item above but for 400 mm size

2

-

230352

... More
Same as item above but for 300 mm size

2

-

104000

... More
Supply of 50 mm sizes double orifice type air valve up to site with specials including lowering the same into trenches and fixing in position & jointing the same with supply of jointing material and testing etc complete.(kirloskar make or as per department direction)

8

-

12090

... More
Supply of all materials and construction of scour valves/NRV/PRV chambers (Masonry type) as per type design. Provisions are included 1.5x1.5 chamber with excavation ,PCC in 1:4:8 ,first class brick work with 12 mm thik plaster with cement mortar in 1:6 ,500 mm medium duty CI main hole cover with perforated locking arrangements , required Mild Steel for chamber etc complete.

18

-

15435

... More
Supply of all materials and construction of air valve chambers (Masonry type)as per type design . Provisions include excavation ,PCC in 1:4:8 ,first class brick work with 12 mm thik plaster with cement mortar in 1:6 ,500 mm medium duty pe CI main hole cover with perforated locking arrangements etc complete.

8

-

4320

... More
Design and Construction of RCC thrust blocks at the bends including supply of all materials labour , T&P etc complete required for proper completion of the works as per department direction.

18

-

17100

... More
Survey ,design and construction of Stone Masonary Pillars with pointing of avg 2.5 metre height with all materials , T&P etc complete for supporting 450 mm dia DI Pipes in DAM catchment areaincluding laying ,jointing,testing and commisioning of 450 mm dia DI k-7 pipe,bailing out of water and fixing with ms clamps etc complete as departmental direction.

700

-

2640

... More
Survey ,design and construction of Stone Masonary Pillars with pointing of avg 2 metre height with all materials , T&P etc complete for supporting 400 mm dia DI Pipes in NALA areaincluding laying ,jointing,testing and commisioning of 400 mm dia DI k-7 pipe,bailing out of water and fixing with ms clamps etc complete as departmental direction.

100

-

3000

... More
Survey ,design and construction of Stone Masonary Pillars of avg 2 metre height with all materials , T&P etc complete for supporting 300 mm dia DI Pipes in NALA areaincluding laying ,jointing,testing and commisioning of 300 mm dia DI k-7 pipe,bailing out of water and fixing with ms clamps etc complete as departmental direction.

100

-

2950

... More
Supply of all materials labour T&P,for 150 mm. thick 1:4:8 mix PCC in foundations for construction of stone masonary pillars for supporting pipe line over and in several places as required.

10

-

4391.48

... More
Barricading of pipe line trenches by using bamboo poles, sheets, rope with red flags, Glow-caution boards, diversion boards & red lights.

1000

-

742.65

... More
Distribution system in Nehru Nagar Zone and Chandmari Zone

-

-

-

... More
Supply of 80 mm DI GI pipes of approved make including railway freight, insurance charges and cartage upto site with required specials etc complete.

57564

-

381.7

... More
Same as above but for 100 mm DI k-7 pipe

4855

-

717.75

... More
Same as above but for 125mm DI k-7 pipe

2219

-

995.95

... More
Same as above but for 150 mm DI k-7 pipe

1865

-

1019.7

... More
Same as above but for 200 mm DI k-7 pipe

3489

-

1282.05

... More
Same as above but for 250 mm DI k-7 pipe

2129

-

1692.9

... More
Same as above but for 300mm DI k-7 pipe

214

-

2153.25

... More
Same as above but for 400 mm DI k-7 pipe

400

-

2979

... More
Excavation in soil mixed with moorum single, kankar and bazari for pipe line trenches with lift upto 1.50 m and lead upto 50 m including disposal of surplus earth within a distance of 50 m from center of trenches also including filling back with watering and ramming of excavated earth in to trenches

27930

-

158

... More
Same as above item but excavation in soft rock and similar types

27930

-

649.12

... More
Barricading of pipe line trenches by using bamboo poles, sheets, rope with red flags, Glow-caution boards, diversion boards & red lights.

1000

-

742.65

... More
Design Laying, jointing testing and commissioning of distribution system Carting of 80 mm dia GI pipes( or as per design), specials, jointing materials to the site of work, lowering the same into the trenches, laying true to alignment and gradient into the trenches / under or above the culvert/ above the masonary pillars/ across the nalas, across the existing pipes or as directed by the department, jointing the same, cutting the length of pipes as per site requirement and also including testing of pipe lines to satisfaction of the department.

57564

-

81.18

... More
Same as above but for 100 mm DI k-7 pipe

4855

-

36.63

... More
Same as above but for 125mm DI k-7 pipe

2219

-

51.8

... More
Same as above but for 150 mm DI k-7 pipe

1865

-

58.9

... More
Same as above but for 200 mm DI k-7 pipe

3489

-

86.13

... More
Same as above but for 250 mm DI k-7 pipe

2129

-

116.01

... More
Same as above but for 300mm DI k-7 pipe

214

-

150

... More
Same as above but for 400 mm DI k-7 pipe

400

-

224.82

... More
Supply of 80 mm sizes of C.I.D/Fscour valves as per I.S. 780-1960 tested to 10Kg/sqm upto site with specials including lowering the same into trenches and fixing in position & jointing the same with supply of jointing material and testing etc complete.(kirloskar make or as per department direction)

6

-

13580

... More
Supply of 80 mm sizes of C.I.D/F sluice valves as per I.S. 780-1960 tested to 10Kg/sqm upto site with specials including lowering the same into trenches and fixing in position & jointing the same with supply of jointing material and testing etc complete.(kirloskar make or as per department direction)

10

-

13580

... More
Same as above but for 100 mm size

4

-

17666

... More
Same as above but for 125mm size

4

-

24477

... More
Same as above but for 150 mm size

2

-

29826

... More
Same as above but for 200 mm size

3

-

50130

... More
Same as above but for 250 mm size

2

-

68112

... More
Same as above but for 300mm size

2

-

87925

... More
Same as above but for 400 mm size

1

-

197795

... More
Supply of 20 mm sizes single orifice type air valve up to site with specials including lowering the same into trenches and fixing in position & jointing the same with supply of jointing material and testing etc complete.(kirloskar make or as per department direction)

12

-

6018.5

... More
Supply of all materials and construction of sluice valve chambers (Masonry type) as per type design. Provisions are included 1.5x1.5 chamber with excavation ,PCC in 1:4:8 ,first class brick work with 12 mm thik plaster with cement mortar in 1:6 ,500 mm medium duty CI main hole cover with perforated locking arrangements , required Mild Steel for chamber etc complete.

16

-

15435

... More
Supply of all materials and construction of sluice valve /air valve /scour valve chambers (surface box type) as per type design

32

-

4320

... More
Shifting of eletric and telephone lines coming in alignment of rising mains and distrbution system

70

-

1800

... More
Nala and Drain Crossing including reinstatement of dismentalled works

70

-

4500

... More
Making connection with OHT and distribution system ,bypass arrangement including supply of all materials, labours and T&P as per requirement & direction of Engineer Incharge.

2

-

25000

... More
Drinking Water Connections to Households Survey of households and Making Ferrule Connection in distribution mains with saddle piece ,services connection fitting and fixing of ferrule of 15 mm size including tapping the mains and cost of fitting and specials as per type design. Provision include supply of all materials GI pipe , HDPE pipe ,elbow ,clamp with saddle ,tap ,stopcock,GI union, etc including dismentling and reinstatement of all types of roads.

6664

-

3500

... More
Dismentalling and reinstatement of roads

-

-

-

... More
Dismentling and reinstatement of interlocking tiles roads ( 60 % Old tiles and 40 % new tiles)including sorting out of serivicable materials , stacking and disposal of unservicable materials with in a distance of 50 m including supply of required new materials & reinstatement the same including supply of all materials ,labour T&P etc complete and per direction of Engineer Incharge.

2050

-

768

... More
same as above for Bitumen roads

15000

-

1620

... More
same as above for CC roads

32000

-

1228

... More
same as above for BOE roads ( 60 % Old and 40 % new )

2050

-

303

... More
Staff Quarters

-

-

-

... More
Construction of full set of staff quarter ( plinth area 144sqm)- Const of full set SQ as per Dept Design and Drawing.( Courtyard Size -6.30mx4.85m- 2Nos ,Room size 4m x 3.2m-2 Nos , Store room- 1.8mx2.10m-2nos, Kitchen 1.8 mx 3.0 m-2 nos,Verandah 3.1mX2.4 m,Bathroom 1.8mX2.4m height of substation 3.3m) .Provisions also include excavation for foundation in all types of soil.Concrete with 40 mm gauge stone ballast sand and cement in 8:4:1 in foundation.CR stone masonary work in foundation .Ist class brick work in 1:6 cement & local sand mortar .20 mm thick D.P.C. R.C.C. work with cement coarse sand and 20 mm gauge stone ballast in proportion of 1:1½:3 in lintels of doors & windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50 mm thick binding wire including necessary shuttering and centring in slabs and sunshades.Earth filling in plinth including supply of earth filling, watering & ramming.25 mm thick 1:2:4 plain cement concrete coarse sand and 20 mm gauge stone ballast laid in panels finished with 3 mm floating coat of neat cement overand including 75 mm thick base concrete consisting of cement and local sand stone ballast 40 mm gauge in the proportion of 1:4:8 and removing and overlapping of mortar at the joints of panels if any giving them uniform finish including supply of all materials, T&P etc. required for proper completion of work with fixing & supply of Glass stripps. 12 mm thick plaster with cement and local sand mortar in 1:6 minimum ,thicknessmaking and fixing of M.S. Grill in window. Supply and fixing angle iron frame for door windows shutters including supply and fixing and adjustment of hinges bolts. hooks & handles springs and other fit things including supply of all fittings. White washing in three coats including supply of all materials labour T&P etc. required for proper completion of work. Apex Painting in three coats including supply of all materials labour T&P etc. required for proper completion of work. Painting two coats over one primer on new iron work.Construction of 100 mm dia PCC drain including supply of all materials, labour T&P etc. required for proper completion of work. Supply and fix 110 mm PVC down pipe including bend coupler clamps etc. Syntex storage tank 300 Lits Capacity. Provide and laying and jointing complete including tees, unions, bends etc. of 15 mm sizes G.I. pipe including excavation and refilling of earth.Construction of septic and soak pits as per department type design including supply and fixing of necessary materials for proper completion of work including clearance of site,electricity works fans ,tubes bulbs etc and required works as per department directions

1

-

13.32

... More
Same as above but for half set of staff quarter (plinth area 72 sqm)

2

-

6.66

... More
Boundary Wall & Related Works

-

-

-

... More
Construction of boundary wall - Supply of all materials ,labour and construction of boundary wall as per type design .Provisions also include excavation for foundation in all types of soil.Concrete with 40 mm gauge stone ballast sand and cement in 8:4:1 in foundation.CR stone masonary work in foundation .Ist class brick work in 1:6 cement & local sand mortar .20 mm thick D.P.C, 2 cm thk CC in 1:2:4 on the top of wall ,12 mm thk plaster in 1:6,apex paints in two coats of approved make etc complte and other required works as per department direction.

571

-

5130

... More
Supply & fixing of 3.60 M wide MS Gate(350 kg) and 1.20 m wide M.S wicket gate(150 kg) as per departmental design including fabrication and supply of steel and construction of boundary pillars all complete.Provisions are included excavation of foundations and construction of RCC columns and fixing of gate.pex paints in two coats of approved make for RCC columns and painted with a coat of metal primer and after this two coats of approved quality paint and other required works as per department direction.

4

-

41191.2

... More
Construction of brick on edge approach road including supply of all materials, labour, tools and plants etc. complete inside the water works campus and as per department direction

220

-

423.11

... More
Supply of all materials ,Labour and T&P for Filling of earth in lower portions including leveling ,cutting and dressing of earth at water works etc complete as per department directions.

2000

-

293

... More
Site developemnt works including plantation(including fiscus tree 2 to 3 m ht) , grassing , construction of approach road outsite the all water works campus ,site clearance etc complete and required necessary works as per department direction.

1

-

1080000

... More
E/M WORKS---------Pumping Plant 1- Supply, installation, testing and commissioning of Vertical Turbine Oil lubricated Raw water pump to lift 6350 LPM discharge at 30 m head complete with 15 m column assembly and discharge head, 75 HP VSS squirrel cage induction motor B class insulation with reversible ratchet, chuck nut and top shaft locking arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. (Synchronous Speed 1000 RPM)

2

-

1759050

... More
M.S. fabricated Dust & Vermin proof of cubical type control panel consisting One no. 400 Amps (ACB) incoming and Two nos. 200 Amp MCCB outgoing for moters and one no. of outgoing with MCB of 100 Amp. for Ligh.t & Fan & spares including Ampere meter, Volt meter, frequency meter, P.F. meter, capacitor, single phasing preventer, Selector switch, fuses etc.

1

-

256500

... More
Auto transformer starter of 75 H.P. with oil suitable for above pumping plant.

2

-

175500

... More
MAIN PIPING AND VALVES :-a. 250mm dia C.I.D.F. Sluice Valve – 2 Nos.,b. 250mm dia C.I.D.F. Reflux Valve – 2 Nos.,c.250X250X250 mm dia C.I.D.F. Tee – 2 Nos,d. 250mm dia D.F. distance piece 1m long – 2 Nos,e. 250mm dia D.F. distance piece 1.5m long – 2 Nos,f. 250mm dia D.F. distance piece 3m long – 2 Nos,g.  250mm dia C.I.D.F. Sluice Valve (for common header) – 2 No,h.  250mm dia C.I.D.F. Reflux Valve (for common header) – 1 No,Nut-Bolt & Rubber Packing - As required,  Any other Item required for proper installation of above Pumps and Necessary Tools for above pumping plant.

1

-

1057500

... More
Electro Magnetic type Pressure & water level indicator gauge with fitting.

2

-

18000

... More
HOT Traveling Trolley with 5 Ton chain pulley Block

1

-

607500

... More
Fire extinguisher

4

-

13500

... More
Power wiring & earthling material.

2

-

49500

... More
Rubber resistance sheet.

6

-

3600

... More
Spare for pump motor and switch gear.

1

-

154800

... More
Supply of Elctro Megnetictype Flow meter size 250 mm dia

1

-

243000

... More
Erection of Pumping plant.

1

-

76500

... More
Commissioning & Testing of pumping plant.

1

-

18000

... More
Internal & External Electrification of Pump House

1

-

81000

... More
painting

1

-

9000

... More
Pumping Plant 2- Supply, installation, testing and commissioning of Vertical Turbine Water lubricated Clear water pump to lift 3650 LPM discharge at 52 m head complete with 4.5 m column assembly and discharge head, 75 HP VHS squirrel cage induction motor B class insulation with reversible ratchet, chuck nut and top shaft locking arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. (Synchronous Speed 1500 RPM)

2

-

1066500

... More
M.S. fabricated Dust & Vermin proof of cubical type control panel consisting One no. 630 Amps (ACB) incoming, Two nos. 200 Amp MCCB outgoing & Two Nos. 200 Amp. MCCB outgoing for moters and One no. of outgoing with MCCB of 200 Amp. for Air Blower, & 100 Amp. MCCB for Light & Fan spares including Ampere meter, Volt meter, frequency meter, P.F. meter, capacitor, single phasing preventer, Selector switch, fuses etc.

1

-

351000

... More
Auto transformer starter of 75 H.P. with oil suitable for above pumping plant.

2

-

175500

... More
MAIN PIPING AND VALVES :-a. 200mm dia C.I.D.F. Sluice Valve – 2 Nos.,b. 200mm dia C.I.D.F. Reflux Valve – 2 Nos.,c.200X200X200 mm dia C.I.D.F. Tee – 2 Nos,d. 200mm dia D.F. distance piece 1m long – 2 Nos,e. 200mm dia D.F. distance piece 1.5m long – 2 Nos,f. 200mm dia D.F. distance piece 3m long – 2 Nos,g.  200mm dia C.I.D.F. Sluice Valve (for common header) – 2 No,h.  200mm dia C.I.D.F. Reflux Valve (for common header) – 1 No,Nut-Bolt & Rubber Packing - As required,  Any other Item required for proper installation of above Pumps and Necessary Tools for above pumping plant.

1

-

769500

... More
Electro Magnetic type Pressure & water level indicator gauge with fitting.

2

-

18000

... More
HOT Traveling Trolley with 5 Ton chain pulley Block

1

-

409500

... More
Fire extinguisher

4

-

13500

... More
Power wiring & earthling material.

2

-

40500

... More
Rubber resistance sheet.

6

-

3600

... More
Spare for pump motor and switch gear.

1

-

154800

... More
Supply of Elctro Megnetictype Flow meter size 200 mm dia

1

-

162000

... More
Erection of Pumping plant.

1

-

63000

... More
Commissioning & Testing of pumping plant.

1

-

18000

... More
Internal & External Electrification of Pump House

1

-

81000

... More
painting

1

-

9000

... More
Pumping Plant 3- Supply, installation, testing and commissioning of Vertical Turbine Water lubricated Clear water pump to lift 2450 LPM discharge at 50 m head complete with 4.5 m column assembly and discharge head, 50 HP VHS squirrel cage induction motor B class insulation with reversible ratchet, chuck nut and top shaft locking arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. (Synchronous Speed 1500 RPM)

2

-

784800

... More
Auto transformer starter of 50 H.P. with oil suitable for above pumping plant.

2

-

130500

... More
MAIN PIPING AND VALVES :-a. 150mm dia C.I.D.F. Sluice Valve – 2 Nos.,b. 150mm dia C.I.D.F. Reflux Valve – 2 Nos.,c.150X150X150 mm dia C.I.D.F. Tee – 2 Nos,d. 150mm dia D.F. distance piece 1m long – 2 Nos,e. 150mm dia D.F. distance piece 1.5m long – 2 Nos,f. 150mm dia D.F. distance piece 3m long – 2 Nos,g.  150mm dia C.I.D.F. Sluice Valve (for common header) – 2 No,h.  150mm dia C.I.D.F. Reflux Valve (for common header) – 1 No,Nut-Bolt & Rubber Packing - As required,  Any other Item required for proper installation of above Pumps and Necessary Tools for above pumping plant.

1

-

675000

... More
Electro Magnetic type Pressure & water level indicator gauge with fitting.

2

-

18000

... More
Fire extinguisher

4

-

13500

... More
Power wiring & earthling material.

2

-

36000

... More
Rubber resistance sheet.

6

-

3600

... More
Spare for pump motor and switch gear.

1

-

126000

... More
Supply of Elctro Megnetictype Flow meter size 150 mm dia

1

-

117000

... More
Erection of Pumping plant.

1

-

63000

... More
Commissioning & Testing of pumping plant.

1

-

18000

... More
painting

1

-

9000

... More
200 KVA power substation at treatment works Supply, Installation, testing and commissioning of 2 mm thick MS sheet fabricated factory wired dust and vermin proof cubical and floor mounted H.T. VCB pannel comprising of one no. incomer of 400 Amp and two nos. outgoning of 400 Amp. Each complete with all internal wiring, C.T.s, P.T.,closing and tripping coil, rear entry cable box to accomodate suitable size of cable, energy analyzer (Draw out type)

1

-

1305000

... More
Supply, Installation, testing and commissioning of 3 phase, 11KV/0.44KV, 50 C/S distribution transformers as per IS 1180 Level - II (copper winding), step down outdoor type of 200 KVA capacity(100% stand by). The transformer should be provided with off load circuit tapchanger for +5% to -5% in steps of 2.5% on HV side. The transformer should have cable box on HT/LT side for termination of cables. The vector group of transformer will be DYN-11.

2

-

747000

... More
Supply, Installation, testing and commissioning of 2 mm thick MS sheet fabricated factory wired dust and vermin proof cubical and floor mounted LT ACB Panel with 2 No. Incomings of 630 Amp and 1 No. Out Goings of 630Amp with one additional MCB of 100 Amp for light and fan load. The LT MCCB Panel shall be Mechanically and Electrically inter locked.

1

-

675000

... More
Supply and Laying of 50 sq. mm. Size 3 core XLPE insulated cable from 11 KV UPPCL metering panel to 11 KV incoming H.T. Switch Gear Panel and up to Transformer

80

-

945

... More
Grounding / Earthing of H.T. VCB Panel, Distribution Transformer, and LT MCCB panel with supply of all earthing materials, digging of pits , grounding (as per I.E.R./ I.S.) including civil work.

1

-

90000

... More
Supply and Laying of 240 sq. mm. Size 3.5 Core Aluminium conductor Cable from Transformers to incomers of L.T. MCCB Panel and from MCCB panel to control panel installed in raw water pumping plant

224

-

1395

... More
Fire extinguisher (5 kg)

2

-

6300

... More
Internal Electrification of Pump House

1

-

81000

... More
Erection, testing and commissioning of Sub-Station.

1

-

45000

... More
160 KVA SUB STATION AT Govind Sagar Dam Site Supply, Installation, testing and commissioning of 2 mm thick MS sheet fabricated factory wired dust and vermin proof cubical and floor mounted H.T. VCB pannel comprising of one no. incomer of 400 Amp and two nos. outgoning of 400 Amp. Each complete with all internal wiring, C.T.s, P.T.,closing and tripping coil, rear entry cable box to accomodate suitable size of cable, energy analyzer (Draw out type)

1

-

1305000

... More
Supply, Installation, testing and commissioning of 3 phase, 11KV/0.44KV, 50 C/S distribution transformers as per IS 1180 Level - II (copper winding), step down outdoor type of 160 KVA capacity(100% stand by). The transformer should be provided with off load circuit tapchanger for +5% to -5% in steps of 2.5% on HV side. The transformer should have cable box on HT/LT side for termination of cables. The vector group of transformer will be DYN-11.

2

-

702000

... More
Supply, Installation, testing and commissioning of 2 mm thick MS sheet fabricated factory wired dust and vermin proof cubical and floor mounted LT ACB Panel with 2 No. Incomings of 400 Amp and 1 No. Out Goings of 400Amp with one additional MCB of 100 Amp for light and fan load. The LT MCCB Panel shall be Mechanically and Electrically inter locked.

1

-

567000

... More
Supply and Laying of 50 sq. mm. Size 3 core XLPE insulated cable from 11 KV UPPCL metering panel to 11 KV incoming H.T. Switch Gear Panel and up to Transformer

80

-

945

... More
Grounding / Earthing of H.T. VCB Panel, Distribution Transformer, and LT MCCB panel with supply of all earthing materials, digging of pits , grounding (as per I.E.R./ I.S.) including civil work.

1

-

90000

... More
Supply and Laying of 95 sq. mm. Size 3.5 Core Aluminium conductor Cable from Transformers to incomers of L.T. MCCB Panel and from MCCB panel to control panel installed in raw water pumping plant

200

-

990

... More
Fire extinguisher (5 kg)

2

-

6300

... More
Internal Electrification of Pump House

1

-

81000

... More
Erection, testing and commissioning of Sub-Station.

1

-

45000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.