UP Jal Nigam Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

UP Jal Nigam - UPJN Tender

Civil Works Water Works
Eprocure

Opening Date

14 Feb 2020

Closing Date

Cancelled

Tender Amount

₹ 1,56,90,171 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(i) Start-stop switch with key

-

-

-

... More
(ii) Water temperature indication

-

-

-

... More
(iii) Lubrication oil pressure indication

-

-

-

... More
(iv) Lubrication oil temperature indication

-

-

-

... More
(v) Battery charging indication

-

-

-

... More
(vi) RPM indication

-

-

-

... More
(vii) Over speed indication

-

-

-

... More
(viii) Low Lub. Oil trip indication

-

-

-

... More
(ix) Engine hours indication

-

-

-

... More
(c) Alternator: Synchronous alternator rated 1010 KVA, 415 volts at 1500 RPM, 03 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation, along with backup protection including inbuilt panel having followig features :

-

-

-

... More
Fabrication & supply of LT panel 415V including bus coupler panel suitable for 1010 KVA silent type D.G. set complete with relays, timer set of CTs, for metering and protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for revers power protection overload, short circuit, restricted earth fault. under frequency, control cabling from panel to Diesel engine and elsewhere if required and all interlocking including the following:

-

-

-

... More
4 pole motorized electrically operated drawout with cradle type 3 position ACB with electromagnetic/electronic release for O/C &E/F and shunt trip.

-

-

-

... More
Auto/Manual/ Test/ Off selector swtich

-

-

-

... More
Over voltage relay, reverse power relay and under voltage relay

-

-

-

... More
3 Sets of current transformer 15P10 accuracy for protection and 15A class-I for metering.

-

-

-

... More
Energy analyser unit to indicate current voltage frequency power factor and KHW

-

-

-

... More
Indicating lamps for load on main and load on set.

-

-

-

... More
Fuse / MCB for instrument

-

-

-

... More
Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.

-

-

-

... More
Main supply failure monitor

-

-

-

... More
Supply failure timer

-

-

-

... More
Restoration timer

-

-

-

... More
Control unit with three impulse automatic engine start/stop and failure to start lockout.

-

-

-

... More
Impulse counter with locking and reset facility.

-

-

-

... More
On /OFF control circuit switch with indicator

-

-

-

... More
Auto/video annuciation for

-

-

-

... More
(i) High water temperature

-

-

-

... More
(ii) Low lubricating oil pressure

-

-

-

... More
(iii) Engine over speed

-

-

-

... More
(iv) Engine fails to start

-

-

-

... More
(v) Full load/ maximum load warning.

-

-

-

... More
Note: Such items or features provided with inbuilt micro processor panel of the D.G. set, need not provide in separate LT panel for PMCC room.

-

-

-

... More
(d) Fuel Tank: Daily service fuel tank of prefrerably 900 litres at the minimum capacity fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.

-

-

-

... More
(e) Exhaust System: Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.

-

-

-

... More
(f) Starting System: 12//24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable Nos. of batteries (25 plates, 180 Amp. hour capacity lead acid type) as required as per specifications.

-

-

-

... More
Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications.

1

-

-

... More
Providing Installation, Testing and Commissioning of silent type Diesel Generating sets along with having prime power rating of 1010 KVA as mentioned above.

1

-

-

... More
Testing at the place of OEM : During this test generator set shall run for at least four hours under the following conditions. 30 minutes at 25% of rated output 30 minutes at 50% of rated output Two hours at 100% rated output One hour at 110% rated output 15 second at 150% rated output Instantaneous swing in voltage and frequency after load removal and block loading. Block load test.

1

-

-

... More
Testing at site.

1

-

-

... More
Supply, Installation & Commissioning of LT switchgear panel 2000A Indooor floor mounted panel for D.G. Set as per details given below:

-

-

-

... More
Fabrication from CRGO sheet size 1.6mm, 2mm and gland plate 3.0mm & supply of LT swtichgear panel 415V floor mounted including bus bars of 2000 Amp. suitable 1010 KVA silent type D.G. set complete with accessories as per details given below:

-

-

-

... More
Auto/Manual/ Test/ Off selector swtich

-

-

-

... More
Over voltage relay, reverse power relay and under voltage relay

-

-

-

... More
3 Sets of current transformer 15P10 accuracy for protection and 15A class-I for metering.

-

-

-

... More
Energy analyser unit to indicate current voltage frequency power factor and KHW

-

-

-

... More
Indicating lamps for load on main and load on set.

-

-

-

... More
Fuse / MCB for instrument

-

-

-

... More
Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.

-

-

-

... More
Main supply failure monitor

-

-

-

... More
Supply failure timer

-

-

-

... More
Restoration timer

-

-

-

... More
Control unit with three impulse automatic engine start/stop and failure to start lockout.

-

-

-

... More
Impulse counter with locking and reset facility.

-

-

-

... More
On /OFF control circuit switch with indicator

-

-

-

... More
Auto/video annuciation for

-

-

-

... More
(i) High water temperature

-

-

-

... More
(ii) Low lubricating oil pressure

-

-

-

... More
(iii) Engine over speed

-

-

-

... More
(iv) Engine fails to start

-

-

-

... More
(v) Full load/ maximum load warning.

1

-

-

... More
Note: Such items or features provided with inbuilt micro processor panel of the D.G. set, need not provide in separate LT panel for PMCC room.

-

-

-

... More
Installation & Commissioning of incomer panel including Interlocking with existing Transformer incomer Panel.

1

-

-

... More
Supply & laying of bus trunking, installation, testing and commissioning of 2000 Amp bus trunking arrangement in covenient section complete with aluminium bus bars for use on three phase, 4 wire, 415V, AC supply for the following current carry capacity, including jointing of sections, flexible joints, expansion joints, bends and earthign with two runs of aluminium strips etc.including XLPE power cable of 1.1 KV grade, of size 5x3.5cx400sqmm / 225x7sqmm as required.

1

-

-

... More
(a) Earthing of D.G. Set and incomer panel: Earthing with GI /copper earth plate 600mm x600mm x6mm in GI or 600x600x3mm for copper including accessories providing masonary enclosures with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete conforming to IS-3034 and IER.

1

-

-

... More
Note: Earth resistance less than 5 Ohm and distance of earthing pits 20 feet from building in case of D.G. set up to 333 KVA and 30 feet more than 333 KVA. Earthing strip size 25x6mm in copper for 250 KVA, D.G. set and 50x6mm for 1010 KVA, D.G. set. 2 earth pits for each neutral and earthing and 2 earth pits for LT panel.

-

-

-

... More
(b) Earthing of incomer panel consisting of 02 Nos. earthing pits with all material, labour required for completion of the work. Earthing shall be in copper strip size 32x5mm, the minimum distance between to earthing pits shall be 02m.

1

-

-

... More
Supply, fabrication & Installation of exhaust system with the existing 30m high exhaust system including all required piping, band support structure complete.

1

-

-

... More
Base Frame and foundation: Bothe the engine and aternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufactuers

1

-

-

... More
Supply & Installation of Lightning Arrestor.

1

-

-

... More
Supply and Installation of Aircraft warning light.

1

-

-

... More
Trial run for three months.

1

-

-

... More
Servicing charges including cost of Mobile oil, Diesel filter and all consumeables etc. First servicing after 50 Hrs. and second servicing after 250 Hrs or at every 06 months, which ever is earlier. Note: HSD oil shall be borne by the department.

2

-

-

... More
Schdule "G-2" D.G. Set (250 KVA)

-

-

-

... More
D.G. set : Consisting of : (a) Diesel Engine 4 stroke water colled, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 meter MSL and conforming to BS-5514, BS 649, is 10000, capable of taking 10% over loading for one hour after 12 hour of continuous operation. The engine will be fitted complete with all the required accessories.

-

-

-

... More
(b) Engine mounted instrument panel fitted with and having digital display for following:

-

-

-

... More
(i) Start-stop switch with key

-

-

-

... More
(ii) Water temperature indication

-

-

-

... More
(iii) Lubrication oil pressure indication

-

-

-

... More
(iv) Lubrication oil temperature indication

-

-

-

... More
(v) Battery charging indication

-

-

-

... More
(vi) RPM indication

-

-

-

... More
(vii) Over speed indication

-

-

-

... More
(viii) Low Lub. Oil trip indication

-

-

-

... More
(ix) Engine hours indication

-

-

-

... More
(c) Alternator: Synchronous alternator rated 250 KVA, 415 volts at 1500 RPM, 03 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation, along with backup protection as per details given below:

-

-

-

... More
Auto/Manual/ Test/ Off selector swtich

-

-

-

... More
Over voltage relay, reverse power relay and under voltage relay

-

-

-

... More
3 Sets of current transformer 15P10 accuracy for protection and 15A class-I for metering.

-

-

-

... More
Energy analyser unit to indicate current voltage frequency power factor and KHW

-

-

-

... More
Indicating lamps for load on main and load on set.

-

-

-

... More
Fuse / MCB for instrument

-

-

-

... More
Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.

-

-

-

... More
Main supply failure monitor

-

-

-

... More
Supply failure timer

-

-

-

... More
Restoration timer

-

-

-

... More
Control unit with three impulse automatic engine start/stop and failure to start lockout.

-

-

-

... More
Impulse counter with locking and reset facility.

-

-

-

... More
On /OFF control circuit switch with indicator

-

-

-

... More
Auto/video annuciation for

-

-

-

... More
(i) High water temperature

-

-

-

... More
(ii) Low lubricating oil pressure

-

-

-

... More
(iii) Engine over speed

-

-

-

... More
(iv) Engine fails to start

-

-

-

... More
(v) Full load/ maximum load warning.

-

-

-

... More
(d) Fuel Tank: Daily service fuel tank of prefrerably 500 litres at the minimum capacity fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.

-

-

-

... More
(e) Exhaust System: Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.

-

-

-

... More
(f) Starting System: 12//24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable Nos. of batteries (25 plates, 180 Amp. hour capacity lead acid type) as required as per specifications.

-

-

-

... More
Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications.

1

-

-

... More
Providing Installation, Testing and Commissioning of silent type Diesel Generating sets along with having prime power rating of 1010 KVA as mentioned above.

1

-

-

... More
Testing at the place of OEM : During this test generator set shall run for at least four hours under the following conditions. 30 minutes at 25% of rated output 30 minutes at 50% of rated output Two hours at 100% rated output One hour at 110% rated output 15 second at 150% rated output Instantaneous swing in voltage and frequency after load removal and block loading. Block load test.

1

-

-

... More
Testing at site.

1

-

-

... More
Supply, Installation & Commissioning of changeover switchgear 400A outdoor floor mounted panel for D.G. Set as per details given below:

-

-

-

... More
Fabrication & supply of outdoor changeover panel 415V floor mounted including bus bars of suitable 250 KVA silent type D.G. set complete with 3 pole position complete in all respect.

1

-

-

... More
Installation & Commissioning of outdoor change over panel IP-55 in line with existing LT incomer transformer feeder.

1

-

-

... More
Supply & laying of 02 Nos. XLPE power cable of 1.1 KV grade size 2x185 sqmm/ 3x95 sqmm in aluminium including installation, testing and commissioning of cabling network procurred for D.G. set in covenient section complete with GI strip size 25x6mm in copper for use on three phase, 4 wire, 415V, AC supply for the following current carry capacity, including jointing of sections, flexible joints, expansion joints, bends etc.

1

-

-

... More
Earthing of D.G. Set and incomer panel: Earthing with GI /copper earth plate 600mm x600mm x6mm in GI or 600x600x3mm for copper including accessories providing masonary enclosures with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete conforming to IS-3034 and IER.

1

-

-

... More
Note: Earth resistance less than 5 Ohm and distance of earthing pits 20 feet from building in case of D.G. set up to 333 KVA. 2 earth pits for each neutral and earthing and 2 earth pits for change over switchgear panel.

-

-

-

... More
(b) Earthing of changeover switchgear panel consisting of 02 Nos. earthing pits with all material, labour required for completion of the work. Earthing shall be in copper strip size 32x5mm, the minimum distance between to earthing pits shall be 02m.

1

-

-

... More
Supply, fabrication & Installation of exhaust system as per specifications.

1

-

-

... More
Base Frame and foundation: Bothe the engine and aternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufactuers

1

-

-

... More
Trial run for three months.

1

-

-

... More
Servicing charges including cost of Mobile oil, Diesel filter and all consumeables etc. First servicing after 50 Hrs. and second servicing after 250 Hrs or at every 06 months, which ever is earlier. Note: HSD oil shall be borne by the department.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.