Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure

Opening Date

4 Feb 2020

Closing Date

9 Mar 2020

Tender Amount

₹ 7,50,950 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and laying XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specifiedand directed.

150

-

-

... More
Supply and laying XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specifiedand directed.

150

-

-

... More
Supply and laying XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specifiedand directed.

140

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable, pole foundation, stay, laying of pipe etc complete all as specified and directed.

84.15

-

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick using soil obtained from excavation complete all as specified and directed.

43.13

-

-

... More
Removing excavated soil to a distance not exceeding 50 metre and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.

41.02

-

-

... More
Supply, lay / spread in trenches, dry river sand , clean including spreading , levelling , punning for laying / cushioning of cables all as specified in clause No 19.75 of SSR Part I and as directed. Note: Only punned thickness will be considered for measurement.

30.29

-

-

... More
Supply, lay in trenches burnt fly ash bricks , old size , for cable protection, laid across the trench complete all as specified and as directed.

2.99

-

-

... More
Supply installation erection commissioning and testing of LT Feeder Pillar cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including Four Pole copper bus bar 300 amp capacity including control wiring with suitable size of PVC insulated stranded copper conductor and incoming/outgoing connection with aluminium busbar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands size of LT Panel 1450mm x 1600mm x 450mm complete comprising the following :-

1

-

-

... More
INCOMING MCCB a) 320 Amp 4 pole MCCB 36 KA breaking capacity with fixed thermal magnetic setting-01 Nos.

-

-

-

... More
OUTGOING MCCBs a) 200 Amp 4 pole MCCB 25 KA breaking capacity with fixed thermal magnetic setting-02 Nos. b) 100 Amp 4 pole MCCB 25 KA breaking capacity with fixed thermal magnetic setting-03 Nos. c) 320 Amp 3 pole Change over Switch-01 Nos.

-

-

-

... More
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-200 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set. c) LED Indicating lamps RYB set of three -01 Sets

-

-

-

... More
Supply installation erection commissioning and testing of LT Feeder Pillar cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including Four Pole copper bus bar 300 amp capacity including control wiring with suitable size of PVC insulated stranded copper conductor and incoming/outgoing connection with aluminium busbar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands size of LT Panel 1300mm x 1700mm x 450mm complete comprising the following :-

1

-

-

... More
INCOMING MCCB a) 400 Amp 4 pole MCCB 36 KA breaking capacity with fixed thermal magnetic setting-01 Nos.

-

-

-

... More
OUTGOING MCCBs a) 200 Amp 4 pole MCCB 25 KA breaking capacity with fixed thermal magnetic setting-03 Nos. b) 100 Amp 4 pole MCCB 25 KA breaking capacity with fixed thermal magnetic setting-03 Nos.

-

-

-

... More
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-200 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set. c) LED Indicating lamps RYB set of three -01 Sets

-

-

-

... More
Supply installation erection commissioning and testing of LT Feeder Pillar cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including Four Pole copper bus bar 300 amp capacity including control wiring with suitable size of PVC insulated stranded copper conductor and incoming/outgoing connection with aluminium busbar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands size of LT Panel 1650mm x 1650mm x 450mm complete comprising the following :-

1

-

-

... More
INCOMING MCCB a) 400 Amp 4 pole MCCB 36 KA breaking capacity with fixed thermal magnetic setting-01 Nos.

-

-

-

... More
OUTGOING MCCBs a) 200 Amp 4 pole MCCB 25 KA breaking capacity with fixed thermal magnetic setting-05 Nos. b) 100 Amp 4 pole MCCB 16 KA breaking capacity with fixed thermal magnetic setting-01 Nos. c) 400 Amp 3 pole Change over Switch-01 Nos.

-

-

-

... More
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-200 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set. c) LED Indicating lamps RYB set of three -01 Sets

-

-

-

... More
Supply installation erection commissioning and testing of LT Feeder Pillar cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including Four Pole copper bus bar 300 amp capacity including control wiring with suitable size of PVC insulated stranded copper conductor and incoming/outgoing connection with aluminium busbar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands size of LT Panel 1650mm x 1650mm x 450mm complete comprising the following :-

1

-

-

... More
INCOMING MCCB a) 320 Amp 4 pole MCCB 36 KA breaking capacity with fixed thermal magnetic setting-01 Nos.

-

-

-

... More
OUTGOING MCCBs a) 160 Amp 4 pole MCCB 25 KA breaking capacity with fixed thermal magnetic setting-06 Nos. b) 100 Amp 3 pole MCCB 16 KA breaking capacity with fixed thermal magnetic setting-01 Nos.

-

-

-

... More
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-200 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set. c) LED Indicating lamps RYB set of three -01 Sets Note :- Make of MCCB, VAF meters are of L&T or equalivant

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.