Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Telecommunication Services
Eprocure

Opening Date

23 Jan 2019

Closing Date

30 Apr 2019

Tender Amount

₹ 29,84,69,191 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the Contractor for "Internal Electrification" as listed in Schedule ‘A’ Part-III **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-III

1

-

1887229.9

... More
Lump sum price worked out by contractor for "Road, Path Culvert and Steel gate" as listed in Schedule `A' Part-IV*Above/below the lump sum price inserted by the MES in Schedule `A' Part-IV

1

-

27324089.98

... More
Lump sum price worked out by contractor for "External water supply" as listed in Schedule `A' Part-V*Above/below the lump sum price inserted by the MES in Schedule `A' Part-V

1

-

1302213.5

... More
Lump sum price worked out by the Contractor for "External Electrification" as listed in Schedule ‘A’ Part-VI **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-VI

1

-

11636112.4

... More
Lump sum price worked out by contractor for "Sewage Disposal" as listed in Schedule `A' Part-VII*Above/below the lump sum price inserted by the MES in Schedule `A' Part-VII

1

-

3266347.41

... More
Lump sum price worked out by contractor for "Area Drainage" as listed in Schedule `A' Part-VIII*Above/below the lump sum price inserted by the MES in Schedule `A' Part-VIII

1

-

5221956.63

... More
Lump sum price worked out by contractor for "Security Fencing, Compound Wall and Steel Gate " as listed in Schedule `A' Part-IX*Above/below the lump sum price inserted by the MES in Schedule `A' Part-IX

1

-

7692824.3

... More
Lump sum price worked out by contractor for "Rain Water Harvesting " as listed in Schedule `A' Part-X*Above/below the lump sum price inserted by the MES in Schedule `A' Part-X

1

-

412925.05

... More
Lump sum price worked out by contractor for "Site Clearance and Earthwork" as listed in Schedule `A' Part-XI*Above/below the lump sum price inserted by the MES in Schedule `A' Part-XI

1

-

4858577.73

... More
Lump sum price worked out by contractor for "Cooling Appliances" as listed in Schedule `A' Part-XII*Above/below the lump sum price inserted by the MES in Schedule `A' Part-XII

1

-

176966.5

... More
Lump sum price worked out by contractor for "Hot Water Supply" as listed in Schedule `A' Part-XIII*Above/below the lump sum price inserted by the MES in Schedule `A' Part-XIII

1

-

45688.2

... More
Lump sum price worked out by contractor for "Demolition/Dismantling of Existing Building/Structure" as listed in Schedule `A' Part-XIV*Above/below the lump sum price inserted by the MES in Schedule `A' Part-XIV

1

-

4957024.29

... More
Provisional Lump Sump (Schedule A Part XV) : this shall be expended wholly or in part as directed by the GE and the work shall be carried out the extent ordered in writing by the GE. The work under provisional lump sum shall be measured and paid for at the applicable (or prorate) rate in MES schedule adjucted by the percentage quoted by the contractor here-in-below:-(A) Provide provisional lump sum for followings :- (a) Foot ball and hockey ground - 02Nos, (b) Basket ball grounds (courts) - 2Nos, (c) Volley ball ground - 02Nos, (d) Parade ground - 12467Sqm

1

-

1950000

... More
Lump sum price worked out by the Contractor for Schedule `A' Part-XVI (rate against Srl No.16.001 to 16.134 shall be quoted by the Contractor)

-

-

-

... More
MCBs, 'C' series,SP and N, 6 Amps to 32 Amps, 230/240 Volts 10 KA breaking capacity,IS-8828 marked and fixing in DBs (DBs catered separately in schedule 'A' Part III). Note : Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III

57

-

-

... More
MCBs, 'C' series,SP and N, 40 Amps, 230/240 Volts 10 KA breaking capacity,IS-8828 marked and fixing in DBs (DBs catered separately in schedule 'A' Part III). Note : Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III

1

-

-

... More
MCBs, 'C' series, TP and N, 6 to 32 Amps, 415 Volts, 10 KA breaking capacity,IS-8828 marked and rating and fixing in DBs (DBs catered separately in schedule 'A' Part III). Note: Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III

6

-

-

... More
MCBs, 'C' series, TP and N, 40 Amps, 415 Volts, 10 KA breaking capacity,IS-8828 marked and rating and fixing in DBs (DBs catered separately in schedule 'A' Part III). Note: Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III

2

-

-

... More
MCBs, 'C' series, TP and N , 63 Amps, 415 Volts, 10 KA breaking capacity,IS-8828 marked and rating and fixing in DBs (DBs catered separately in schedule 'A' Part III). Note: Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III

4

-

-

... More
MCBs, 'C' series, SP, 6 Amps to 32 Amps, 230 Volts, 10 KA breaking capacity,IS-8828 marked and rating and fixing in DBs (DBs catered separately in schedule 'A' Part III).- Note: Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III

381

-

-

... More
Supply and Fix LED light fitting high quality indoor LED tube light with aluminium extrusion housing T5 Batten 20 Watt as per Neptune Plus HPL Cat No HPLT51520WW complete including copper cable 23/.0076 for electric connection for fitting from ceiling rose all as specified and directed complete. Make as specified in appendix B to particular specifications.

750

-

-

... More
Supply and Fix LED light fitting high quality indoor LED tube light with aluminium extrusion housing T5 Batten 40 Watt as per Cadila Plus HPL Cat No HPLLEDCADPL40CW complete including copper cable 23/.0076 for electric connection for fitting from ceiling rose all as specified and directed complete. Make as specified in appendix B to particular specifications.

80

-

-

... More
Supply & fix batten holder PVC with LED Bulb 8 watt fixed on ceiling/wall.

33

-

-

... More
Supply and Fix LED Secuirity light fitting with pressure die cast aluminium housing 30 Watt including copper cable 23/.0076 for electric connection for fitting from ceiling rose all as specified and directed complete. Make as specified in appendix B to particular specifications.

44

-

-

... More
Supply and Fix Surface/Recess mounted economical LED Panel light with high quality diffuser for uniform light, CRCA Housing. Separate replaceable electronic driver, Suitable for recess and surface 36 Watt LED as light source complete including copper cable 23/.0076 for electric connection for fitting all as specified and directed complete. Make as specified in appendix B to particular specifications.

28

-

-

... More
S & F wall mounted fan (oscillating type) suitable for sp 230/250 Volts 50 Hz AC supply of 300 mm sweep including fixing/ grouting on wall complete and connecting with three numbers FRLS cable with multistranded copper conductor from ceiling rose to fan complete all as specified and directed . Make as specified in appendix B to particular specifications.

20

-

-

... More
Supply, installation and commissioning of refrigerators, electric driven, 230 Volts, (single phase), 50 HZ, having nominal storage capacity 215 ltrs direct cool, Single door, 4 Star BEE rating, colour as approved by GE. Make as specified in appendix B to particular specifications.

10

-

-

... More
Supply, installation and commissioning of refrigerators, electric driven, 230 Volts, (single phase), 50 HZ, having nominal storage capacity 286 ltrs direct cool, Single door, 4 Star BEE rating, colour as approved by GE. Make as specified in appendix B to particular specifications.

2

-

-

... More
Supply, installation and commissioning of refrigerators, electric driven, 230 Volts, (single phase), 50 HZ, having nominal storage capacity 320 ltrs direct cool, Single door, 4 Star BEE rating, colour as approved by GE. Make as specified in appendix B to particular specifications.

2

-

-

... More
Installation & Commissioning only water cooler electric driven (single phase), having approx storage capacity of 80 litres and nominal cooling capacity of 40 litres per hour with partial stainless steel body. Note:- To be issued under Sch'B' free for fixing

12

-

-

... More
Installation & Commissioning only air cooled split unit Air Conditioners electric driven single Phase of Capacity of 2 TR having non -CFC refrigerant with maximum BEE Star rating. (Note: Rates are inclusive of water drain pipe, thermal insulation of refrigerant pipe nut, bolts , brackets etc all necessary fixing arrangements all as directed. Note:- To be issued under Sch'B' free for fixing)

6

-

-

... More
Supply and fix Telephone Jack (socket) with shutter fixed on terminal box catered in Schedule `A’ Part-III.

50

-

-

... More
Supply and fix TV antena outlet (socket) fixed on terminal box catered in Schedule `A’ Part-III.

70

-

-

... More
Installation & Commissioning only Desert cooler ( overall minimum size 26 inch x 26 inch x 39 inch) made out of 18 guage galvanised sheet, depth of water tank shall 11 inch, electric driven, 230 Volts, single phase, 50 Hz supply having nominal air flow capacity of 3000 Cubic meter per hour or nearest standard size on platform provided in building catered in Schedule 'A' Part I including provision of PVC connection heavy duty 750 mm long with brass union at both ends for necessary water connection. Note:- To be issued under Sch'B' free for fixing)

155

-

-

... More
Fixing only Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & desiged for input variation between 170V to 250V with output voltage stabilied at 230V with accuracy of +/- 2.5 % and of capacity 1.0 KVA with 2 to 3 minutes time delay relay. Note:- To be issued under Sch'B' free for fixing)

12

-

-

... More
Fixing only Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & desiged for input variation between 170V to 250V with output voltage stabilied at 230V with accuracy of +/_ 2.5 % and of capacity 3 KVA with 2 to 3 minutes time delay relay . Note:- To be issued under Sch'B' free for fixing)

14

-

-

... More
Fixing only Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & desiged for input variation between 170V to 250V with output voltage stabilied at 230V with accuracy of +/_ 2.5 % and of capacity 5.0 KVA with 2 to 3 minutes time delay relay. Note:- To be issued under Sch'B' free for fixing

6

-

-

... More
Installation, testing & commissioning by OEM (i.e. Kirloskar) for Silent Diesel Engine Driven generating Set 415V 3 phase 4 wire engine of capacity 40 KVA including replacement of 12 V 88 AH Lead acid battery with copper connecting leads and brass clamps. Installation includes the Servicing and Testing by OEM (Original Equipment Manufacturer) of DG Set including repair/replacement of faulty/damaged control wiring, MCCB TPN 35 KA, RPM Meter, Lube Oil, Temperature, pressure gauge, water temp gauge, frequency meter,battery charging ammeter,self starter, battery charging alternator,Starting push button and ON-OFF Key switch, Volt meter, ammeter etc complete. Notes: (i) DG SET 40 KVA shall be issued by department Free for fixing. (ii) Item includes shifting of DG SET 40 KVA from MES Yard to Proposed Subsattion. (Appx Distance 1.0 Kms) using necessary T&P and Lifting Crane etc. (iii) Item includes PCC Foundation of DG set in (1:3:6) , Type C2m , using 40 mm graded stone aggregate of size 6.0 X3.0X0.6 m. (iv) Item includes Replacement of engine oil 6.5 ltrs , oil filter and fuel filters.

1

-

-

... More
Fixing, Installation, Testing and Commissioning of 'Solar Hot Water System' based on indirect transfer of heat of capacity 200 LPD with heat exchanger type with, electric heating back up 3 KW and backup stainless steel hot water tank insultated . Note:- To be issued under Sch'B' free for fixing)

6

-

-

... More
Material and labour for Disc type insulator,porcelain, vitreous 145 mm high & 255mm dia ball and socket type white or brown or green, 'three In series' assembly for tension with tension clamps for conductors,working pressure 33 KV complete tensile strength 20 KN.

9

-

-

... More
Material and labour Pin type, porcelain vitreous , white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33000 volts grade. 210 mm high and 255 mm dia tensile strength 20 KN.

9

-

-

... More
Supply and fix LED 40 watt decorative post top light fitting 360 degree indirect light, corrosion resitant,glare free in IP-65 protection connectors etc suitable for working on 50Hz, 240 V AC supply including suitable size GI ppe for fixing on post, all as specified. Make as specified in appendix B to particular specifications.

8

-

-

... More
Supply and fixing poly carbonate junction box , weather and vermin proof of suitable size including provn of 2 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators , including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps of suitable size for taking connections and fixing on LT steel tubular poles complete with locking arrangement complete.

144

-

-

... More
Supply, installing, testing and commissioning, factory made and tested , (including CPRI type tested and certified ) indoor type , floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with insulated copper bus bars 1200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP-54 Protection class and made out of 16 SWG CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work in the bottom of the panel , powder coated finish over one coat of red oxide primer ,double shutter front & rear opening type, including internal connection with suitable size of insulated copper bus bar , 1100 volts grade , and panel to be suitabely grouted on the floor in side the sub station with necessary arrangements including marking of incoming and out going feeders including danger notice plate and accessories and comprising of the following :- (For TR 315 KVA main LT panel 1 at Officers Accn Pocket No-1 ) INCOMING: (i) ACB, 630 amp, 4 pole, 50 KA, with micro processored based MDO type with integral over load, short circuit & earth fault & neutral protection, incl separate indication of fault display of current, voltage and bar graph on ACB 50 Hz, 415 volts grade - 01 No. (ii) LCD Multifunctional meter accuracy class 1.0,0.5,input voltage measurement range 17-550 VAC(P-P),Aux supply 90-300VAC,Flush mounting 96x96mm,Site selectable 1A/5A,CT/PT site programmable with RS485 port along with Following parameters :-VA,F,PF,kW,kVA,kVAR,kWh,kVAh,kVARh,run hours,On hours,Intrrupts,RPM,% and balance(V,A),Phase angle,THD,Neutral current,% load,max demand(KW and kVA),MD reset and Bi-directional- 01 Nos (iii) LED Indicating lamps : ­­ 01 set of three OUTGOING: (i) MCCB 3 Pole 320 Amps 36 KA Therrmal magnetic release, 415 V,50 HZ -01 Nos (ii) MCCB 3 Pole 63 Amps 25 KA Therrmal magnetic release, 415 V,50 HZ -02 Nos (iii) MCCB 3 Pole 50 Amps 25 KA Therrmal magnetic release, 415 V,50 HZ -02 Nos (iv) Auto Timer Switch 1 Phase 32 amps - 01 Nos (iv) LED Indicating lamps for each outgoing feeder ­ 05 ( set of three) NOTE: (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.

1

-

-

... More
Applying thermoplastic reflective paint as in road marking of minimum 2.5 mm thick single coat of 100/150 mm wide using HOT MARK thermoplastic paint (Hot application) white or golden yellow by indigenous modern properly road marking machine as directed incl all ingredients such as binder glass beads shall titanium dioxide calcium carbonate inter filler thermoplastic

1113

-

-

... More
S&F solar studs LED based made of aluminium alloy shell size 125mm x 125mm x 25mm (shank 60mm) 100% water proof according to Lp 65, high effeincy mono- crysiline solar panel 2.4 V/0.3 wff, one Ni- Mh or Ni-cd rechargeable battery (1.2V/1600MA) six supper bright LEDs with 10000 to 18000 med (Milicandela), maintenance free, view distance upto 1000 mtrs, flash rate 2Hz, beasable weight 10 ton (Approx). Make as specified in appendix B to particular specifications.

1162

-

-

... More
Supply and fix informatory sign boards (single sides) of size 90 x 60 cm made of 2.0 mm thick aluminium sheet duly framed with angle iron 40x 40x 5 mm size with the help of stainless steel nuts/bolts/aluminium rivets with front face of aluminium sheet to be fully covered by blue dimond grade micro prismatic type IX Retro Reflective Sheeting matter by overlay with colour film & back side painted with grey epoxy paint incl fixing provision of two posts of MS pipe 75 mm dia 3m long duly painted in black and white alternate bands of synthetic enamel paint & hold fast at bottom & PCC (1:2:4) fdn concrete, with necessary earthwork etc.

15

-

-

... More
S&F delinators comprising two high perfarmence 100 mm dia high reflectors and two rectangular reflectors of EYE or equivalent 70 mm x 23 mm fixed on both sides of guide post, reflectors shall be positioned at the best eye guiding level so that crivers can be warned from a safe distance. The body of gulce post shall be moulded in ABS plastice and fixed on powder coated steel pipe of 1mtr height Make as specified in appendix B to particular specifications.

56

-

-

... More
Boring holes in any type of soil for increasing PVC/HDPL 150 mm pipe for 6.00 m deep etc compleate all as specified

60

-

-

... More
Supply and fix 150mm bore perforated UPVC pipe for inserting in hole etc complete all as specified

60

-

-

... More
Pea gravel size 3-6 mm to be filled in perforated pipe etc complete all as specified

61

-

-

... More
Supply and fixing 150 mm dia stainless steel grating etc complete all as specified

10

-

-

... More
Ready made cast iron decorative crowns welded at top of each vertical box section.

1961

-

-

... More
Supplying, laying in trenches, under floor, under road, connecting , jointing and testing ductile iron pressure pipe centrifugally cast ISI marked, with socket and spigot ends confirming to IS 8329/2000 in standard length, of K7 specification with outside zinc coating complete with EPDM rubber ring as per IS 5382 of 100mm bore. Note :Tyton joints, special DI fittings, excavation & earth work are excluded from the scope of this item and shall be measured and paid for separately

2830

-

-

... More
Supplying, laying in trenches, under floor, under road, connecting , jointing and testing ductile iron pressure pipe centrifugally cast ISI marked, with socket and spigot ends confirming to IS 8329/2000 of standard length, of K9 specification with outside zinc coating complete with EPDM rubber ring as per IS 5382 of 150 mm bore size Note :Tyton joints, special DI fittings, excavation & earth work are excluded from the scope of this item and shall be measured and paid for separately

1150

-

-

... More
Ductile iron fittings,IS-9523 marked viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle / radius and straight connecting pieces, flanged / socket and spigot ends, size of following pipe upto 150 mm bore, complete all as specified.

850

-

-

... More
Fabrication, installation testing ERW pipe distribution header of under mentioned size including branches complete with welding work with two coat of anti corrosive spray paint over a coat of red oxide primer,complete with end plates provision of following Main Header: Main Header of size 200 mm bore x 4.0 mtr long made of ERW pipe 5.4 mm thick complete with end plates 10mm thick welded at both ends. INCOMING: (i) Incoming branch of size 100 mm bore ERW pipe with one sluice valve 150mm bore, PN1.6 complete - 01 No OUTGOING: (i) Branch Connection of size 150 mm bore ERW pipe with one sluice valve 100 mm bore, PN1.6 on each branch complete- 01 Sets (ii) Branch Connection of size 100 mm bore ERW pipe with one sluice valve 80 mm bore, PN1.6 on each branch complete- 02 Sets ( 01 for wash out)

1

-

-

... More
Trench less boring by HDD Machine of existing road/ path for laying of DI pipe 150/100 mm dia including making good disrurbed area / surface complete all as specified.

100

-

-

... More
Supply, installation, testing and commissioning centrifugal pump, horizontally split casing type Single stage , cast iron body with, SS Shaft , bronze impellers of discharge 625 LPM at 35 Mtrs head complete with electric driven TEFC motor not less than 7.5 H.P. 1450 RPM of suitable capacity for 3 phase star delta connected 415 volts 50 Hz , AC supply complete with MS base frame, PCC foundation, AVM Pads as recommended by manufacturer all as specified and directed . (a) MS suction pipe 100 mm bore, heavy grade, of suitable length but not less than 6.00 m complete with all fittings as required at site. (b) MS delivery pipe 80 mm bore, heavy grade, of suitable length but not less than 6.10 m complete with all fittings as required at site. (c) CI foot valve, with leather washer, of suitable size, lift and swing, single door, IS 4030 marked one with each pump sunction line. (d) Provn of high performance soft starter of suitable capacity ,single phase preventer (complete with UV/OL protection ) and mounted in panel (Panel catered for separately) and also including necessary cable connection with PVC insulated but unsheathed LT cable with suitable size multi stranded copper conductors cable from LT panel to motor ( laid in adequate size GI pipe), all as specified and directed

2

-

-

... More
Supply, connect, lowering, testing and commissioning Energy efficient Submersible pump set complete of capacity 180 LPM, 125 M head with suitable cap of electric motor but not less than 7.5 HP capacity , electric driven 415V TP of following capacity or nearest higher with stainless steel body and SS impeller, diffuser & diffuser casing complete with MS iron hoock -02 Nos welded at the top of motor head suitable to tie SWR rope for anchoring complete all as specified and directed at site by Engr-in-charge. (A) Provn of Fully automatic Star Delta starter for 7.5 HP submersible pump comprising of power contactor 3 pole, single phase preventor, auto over ride switch, ET-100 timer, relay for over load and including necessary cable connection with PVC insulated but unsheathed LT cable of suitable size multi stranded copper conductors cable from bus bar with screw less connector cage clamp type spring loaded made of nylone 6.6 V00 grade all as specified and directed. (B) Microprocessor based protection relay 5A to 60A with Over load, phase failure,locked rotar,phase unbalance,phase reverse protections with site selectable definite and inverse type characteristics with test reset button. The relay shall be provided with seven segment display unit for normal and fault diagnosis.

3

-

-

... More
Supply and fixing 1100 volts grade submersible cable flate 3 core with copper conductor 6.0 sqmm stranded fixed to column pipes with suitable clamps jointing material complete.

600

-

-

... More
Supplying, installing, testing and commissioning electric motor driven (PP/PVC head) type automatic bleaching powder doser, 240 LPD, 10 BAR capacity with solutioniser tank to treat water,complete with rubber bag and all fittings / accessories / valves etc (dozer body internally coated with anticorrosive resin lining), painted DA grey ( 2 coats of synthetic enamel paint over a coat of red oxide primer) on the outer surfaces. The scope of work includes material and labour for pipe connections with 15 mm dia GI pipe (medium grade) / PVC pipe (heavy duty, nylon thread braided), double flanged ventury assembly pipe with orifice plate, for 20 mm bore pipe and also connecting with existing rising main and including provision of steel ladder 2.5 mtr height (made of angle iron 40 x 40 x 6 mm thick and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer) for adding bleaching powder in the solutioniser tank complete, all as specified and directed, Make as specified in appendix B to particular specifications.

1

-

-

... More
Supplying, installing, testing and commissioning gaseous chlorination ( chloronome ) plant, vacuum feed type fitted with standard fittings like vacuum regulator (with integrated safety valve) ,filter and pressure gauge, flow meter or Rotameter Ejector, PE tubing etc, direct cylinder mounted, suitable to deliver 25 to 500 gm / hr of chlorine gas for chlorination of water, dozing capacity 1 to 5 ppm including two no. chlorine gas filled cylinder ,injector assembly Back stop, non return valves with back pressure regulator,control valves, pressure reducing valve, auto changeover valve, activated carbon filter safety shut off valve and inclusive of Cannister type gas mask kit, chlorine absorption system and booster pump-set (multistage, stainless steel impellers) suitable for operation on 3 phase, 415 volts, AC supply including DOL starter to operate electric motor and MCB TPN415 volt, 10 Amp enclosed in DB four pole 1 way (fixed in recess in wall) and necessary connection with suitable size of PVC insulated but unsheathed, multistranded copper conductor FRLS cable IS 694 marked single core cable 4 sq mm (nominal area) from switch board to motor through MCB and starter laid through 40 mm bore GI pipe (light grade pipe ) fixed to wall / embedded in floor (and in inescapable portion through PVC flexible conduit) complete all as directed. Note : Incoming connection of MCB TPN with PVC insulted unsheathed copper conductor 4 sq m, 4 RM shall be in PVC rigid conduit concealed in wall from existing panel board of pumping set and cost of the same is deemed to be included in the unit rate quoted to contractor

1

-

-

... More
Trial bore holes 150 mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000 for exceeding 0 Mtr but not exceding 50 mtr in depth from ground level

150

-

-

... More
Trial bore holes 150 mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000 for exceeding 50 Mtr but not exceding 100 mtr in depth from ground level

150

-

-

... More
Trial bore holes 150 mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000 for exceeding 100 Mtr but not exceding 150 mtr in depth from ground level

150

-

-

... More
Widening of trial bore by drilling with reverse rotary system upto 500 mm dia bore at any depth including all works pertaining to boring complete in all respects and all specified in aluvium spoil/soft strata incl hard stone/boulder etc. upto 150 mtr depth from ground level.

450

-

-

... More
Trial bore hole of 175mm dia in hard rock and drilling with DTH system exceeding 150mtr depth but not exceeding 200 mtr depth from ground leve including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000

225

-

-

... More
Assembling, jointing ,screwed,welded, lowering and fixing in position of ERW MS casing pipe 200 mm dia of 8 mm thickness complete as per IS-4270 : 2000 upto required depth below ground level in all strata (according to location chart) cut into different lengths ISI marked and all as specified and directed by Engr-in-Charge. Note :To be issued under Sch "B' Part II

120

-

-

... More
Supplying, assembling, including jointing, lowering and fixing in position ERW Stainless steel slotted pipe 200 mm dia of 8 mm thickness (minimum) as per IS-8110 : 2000 having slots of 1.59 mm wide 3" long assembled and lowered as per electrologging result and location approved by the GE including cutting welding as required complete all as specified.

60

-

-

... More
Supply and fixing of well cap of 200 mm dia size on top of pipe all as specified & complete with locking arrangement.

3

-

-

... More
Development of tube well by compressed air with compressor of minimum capactiy of 1100/350 CFM/PSI all as specified.

72

-

-

... More
Yield testing of bore well by continous pumping for 16 hrs to determine the safe pumping yield.

3

-

-

... More
S/F housing clamp 90 cm long 20 cm wide out of 20 mm thick MS plate for 250 mm dia casing pipe with necessary MS bolts, nuts and washers at ground level in PCC (1:2:4) type B 1 using 20 mm granded stone aggregate in block all as specified.

3

-

-

... More
M&L for strata sample box of second class hard wood of size 40 cm X 30 cm x 20 cm complete all as directed by Engineer-in-Charge.

3

-

-

... More
Supply and fix GI column pipe medium grade IS-1239 marked 50 mm bore x 3 mtr long both end flanged joints duly screwed and welded with pipe suspended in deep bore well with groove/cut for submersible cable screwed and welded on both ends.

90

-

-

... More
Supply fixing and lowering into bore holes centring guides suitable for 200 mm bore housing/ casing pipe all as specified

9

-

-

... More
Testing of water for chemical , bacteriological and potability test form Govt Lab and submission of testing report.

3

-

-

... More
Electro logging by means of eletric logger of the complete tube well of 500 mm bore and submission of report along with its interpretation by GWB scientist complete as directed.

3

-

-

... More
Development of tube well by means of submersible pump (of performance capacity not less than 12500 LPH) as reqd to make the well sand free upto 20 ppm in 20 min complete all as specified.

72

-

-

... More
Supply & Lay for rubber insulated mattings as per IS of size 1.0 x 2.00 mtr, 12 mm thickness complete all as specified.

3

-

-

... More
Relaying of DI Pipeline removed in trenches/under roads/floors etc complete all as directed by Eng In Charge

350

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 400 Sqmm 3 1/2 core.

50

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 240 Sqmm 3 1/2 core.

190

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 185 Sqmm 3 1/2 core.

260

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 120Sqmm 3 1/2 core.

265

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 95Sqmm 3 1/2 core.

100

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 70 Sqmm 3 1/2 core .

150

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 50 Sqmm 3 1/2 core .

285

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 25 Sqmm ,4- core .

1340

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 16 Sqmm ,4- core .

2000

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 16 Sqmm ,2- core .

420

-

-

... More
Laying only cable XLPE insulated screened PVC, galvanised steel strip or wire armoured ellectric power cable (Heavy duty) 1100 volts grade with Aluminium conductor of size 10 Sqmm ,2 - core .

2400

-

-

... More
Supply install,testing and commissioning LT panel boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 1200 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(For TR-400 KVA NO-2, Main LTP-2 at Near Gurad House Pocket No 3) INCOMING: (i) ACB, 630 amp, 4 pole, 50 KA, with micro processored based MDO type with integral over load, short circuit & earth fault & neutral protection, incl separate indication of fault display of current, voltage and bar graph on ACB 50 Hz, 415 volts grade - 01 No. (ii) LCD Multifunctional meter accuracy class 1.0,0.5,input voltage measurement range 17-550 VAC(P-P),Aux supply 90-300VAC,Flush mounting 96x96mm,Site selectable 1A/5A,CT/PT site programmable with RS485 port along with Following parameters :-VA,F,PF,kW,kVA,kVAR,kWh,kVAh,kVARh,run hours,On hours,Intrrupts,RPM,% and balance(V,A),Phase angle,THD,Neutral current,% load,max demand(KW and kVA),MD reset and Bi-directional- 01 Nos. (ii) LED Indicating lamps : ­­ 01 set of three OUTGOING: (i) MCCB 3 Pole 250 Amps 36 KA Therrmal magnetic release, 415 V,50 HZ -01 Nos (ii) MCCB 3 Pole 125 Amps 36 KA Therrmal magnetic release, 415 V,50 HZ -01 Nos (W/S) (iii) MCCB 3 Pole 100 Amps 36 KA Therrmal magnetic release, 415 V,50 HZ -02 Nos (iv) MCCB 3 Pole 50 Amps 25 KA Therrmal magnetic release, 415 V,50 HZ -05 Nos (v) LED Indicating lamps for each outgoing feeder ­ 07 ( set of three) NOTE: (i) All out going feeders shall be connected by cable through suitable size gland plate / glands.

1

-

-

... More
Supply install,testing and commissioning LT panel boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15mm thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 400 amps copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(TR-160 KVA, Main LTP-3 at MT area) INCOMING: (i) MCCB 4 Pole 250 Amps 36 KA Therrmal magnetic release, 415 V,50 HZ -01 Nos (ii) Voltmeter 0-500 volts, square, 144 mm, flush pattern with 3 way rotary selector switch - 01 No (iii) Ammeter size 144 mm, square dial, flush pattern having dual range 400 amps with three way rotary selector switch including suitable size of CT - 01 No (iv) LED Indicating lamps : ­­ 01 set of three OUTGOING: (i) MCCB 3 Pole 50 Amps 25 KA Therrmal magnetic release, 415 V,50 HZ -04 Nos (ii) LED Indicating lamps for each outgoing feeder ­ 04 ( set of three) NOTE: (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT panel boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 600 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(LTP-1 Pocket NO -1 Near Officers Accn) INCOMING: (i) MCCB 4 Pole 320 Amps 36 KA Therrmal magnetic release, 415 V,50 HZ -01 Nos (ii) Ammeter 0-600 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 100 Amps , 36 KA Therrmal magnetic release -02Nos (ii) MCCB, 3 pole, 40 Amps , 25 KA Therrmal magnetic release -03Nos (iii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iv) Ammeter as per out going rating with CTs -07 (vi) All out going feeders shall be connected by cable through suitable size gland plate / glands. (vii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (viii) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT panel boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 400 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(LTP-2 Pocket NO -2 Near Guard House) INCOMING: (i) MCCB 4 Pole 250 Amps 36 KA Therrmal magnetic release, 415 V,50 HZ -01 Nos (ii) Ammeter 0-500 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 125 Amps , 36 KA Therrmal magnetic release -01Nos (ii) MCCB, 3 pole, 100 Amps , 36 KA Therrmal magnetic release -01Nos (iii) MCCB, 3 pole, 40 Amps , 25 KA Therrmal magnetic release -02Nos (iv) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (v) Ammeter as per out going rating with CTs -04 (vi) All out going feeders shall be connected by cable through suitable size gland plate / glands. (vii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (viii) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65 double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 200 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-01 Pocket No-1 Near servant Qtr ) INCOMING: (i) MCCB, 4 pole, 40 Amps , 25 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-200 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole,25 Amps Therrmal magnetic release , 25 KA -02Nos (ii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iii) All out going feeders shall be connected by cable through suitable size gland plate / glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (v) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 250 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-02 Pocket No-2 Near FWC ) INCOMING: (i) MCCB, 4 pole, 125 Amps , 36 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-300 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole,100 Amps Therrmal magnetic release , 36 KA -01Nos (ii) MCB, 2 pole, 32 Amps , 10 KA -03 Nos (iii) All out going feeders shall be connected by cable through suitable size gland plate / glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (v) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 200 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-03 Pocket No-2 Near Education Bldg ) INCOMING: (i) MCCB, 4 pole, 100 Amps , 36 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-200 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 63 Amps Therrmal magnetic release , 25 KA -01Nos (ii) MCCB, 3 pole, 25 Amps Therrmal magnetic release , 25 KA -02Nos (iii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iv) All out going feeders shall be connected by cable through suitable size gland plate / glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (vi) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 150 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-04 Pocket No-3 Near Guard House ) INCOMING: (i) MCCB, 4 pole, 63 Amps , 25 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-200 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 25 Amps Therrmal magnetic release , 25 KA -03Nos (ii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iii) All out going feeders shall be connected by cable through suitable size gland plate / glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 250 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-05 Pocket No-3 Near Admn Block) INCOMING: (i) MCCB, 4 pole, 125 Amps , 36 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-300 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 100 Amps Therrmal magnetic release , 36 KA -01Nos (ii) MCCB, 3 pole, 40 Amps Therrmal magnetic release , 25 KA -01Nos (iii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iv) All out going feeders shall be connected by cable through suitable size gland plate / glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.(vi) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply, install, testing and commissioning factory made and tested (CPRI test certified) LT panel indoor type, dust and vermin proof totally enclosed plateform mounted (Protection class IP-54) double shutter gears front and rear frame work and 16 SWG thick MS sheet powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and neutral system and shall be completed with 200 amps capacity Copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:- (Near Sump Pump House) INCOMING: (i)MCCB, 4 pole, 100 Amp, 25 KA -01 No (ii) Changeover switch 4P, 40 Amps ,415V -01 No. (iii) Ammeter 0-100 Amps with CTs -01 No. (iv) Voltmeter 0-500 volts with selector switch -01 No (v)Indicating lamp- 01 set of three OUTGOING: (i) MCCB 4P, 25Amp, 16 KA -06 Nos (ii) MCB SPN 6 Amp -01 Nos (iii)Space for centrifugal pump starter complete with single phase preventor over load protection etc - 02 (v)Single phase preventer

1

-

-

... More
Supply, install, testing and commissioning factory made and tested (CPRI test certified) LT outdoor type control panel type, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 100 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15 mm thick CRCA sheet powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation bolt grouted in PCC 1:2:4 for mounting the panel ,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:- .( panel for bore well) INCOMING: (i) MCCB 25 Amps, rating 415 Volts, 16 KA 4 pole with thermal magnetic setting type - 01 No. (ii) Changeover switch 4P,100 Amps ,415V -01 No. (iii) Voltmeter with selector switch 0-500 V- 01 No (iv) Ampere meter 0-50 Amps with CT and selector switch - 01 No (iv) LED indicating lamps RYB-01 Set (Set of three) OUTGOING: (i) MCCB 20 Amps, rating 415 Volts, 3 pole 25 KA -1Nos (ii) Space for fixing starter of submersible pump as per motor capacity -1 Nos (iii) Ammeter with suitable CT's complete connected with each motor starter - 01Nos (iv) MCB 16 Amp 10 KA, SPN, 230 volts grade-01 No (v)Single phase preventer

3

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 200 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-06 Pocket No-3 Near Jcos Accn ) INCOMING: (i) MCCB, 4 pole, 100 Amps , 36 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-200 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 40 Amps Therrmal magnetic release , 25 KA -01Nos (ii) MCCB, 3 pole, 25 Amps Therrmal magnetic release , 25 KA -03Nos (iii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iv) All out going feeders shall be connected by cable through suitable size gland plate / glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 200 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-07 Pocket No-3 Near Cook house) INCOMING: (i) MCCB, 4 pole, 100 Amps , 36 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-200 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 40 Amps Therrmal magnetic release , 25 KA -02Nos. (ii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iii) All out going feeders shall be connected by cable through suitable size gland plate / glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (v) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 100 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-08 Pocket No-3 Near Bldg No 119 ) INCOMING: (i) MCCB, 4 pole, 50 Amps , 25 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-200 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 25 Amps Therrmal magnetic release , 25 KA -02Nos (ii) MCB, 2 pole, 32 Amps , 10 KA -02 Nos (iii) All out going feeders shall be connected by cable through suitable size gland plate / glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (v) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning LT feeder pillar boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 100 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(FP-09&10 Pocket No-4 MT Area ) INCOMING: (i) MCCB, 4 pole, 50 Amps , 25 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-200 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING:(i) MCB, 2 pole, 32 Amps , 10 KA -09 Nos (ii) All out going feeders shall be connected by cable through suitable size gland plate / glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iv) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning Street light feeder panel boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 100 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(SL FP-1,2,3,4 for Pocket No-1, 2 &3) INCOMING: (i) MCCB, 4 pole, 50 Amps , 25 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-100 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCCB, 3 pole, 25 Amps Therrmal magnetic release , 25 KA -02Nos (ii) MCB, 2 pole, 20 Amps , 10 KA -02 Nos (iii) Auto Timer Switch 3 Pole 25 amps - 02 Nos (iv) All out going feeders shall be connected by cable through suitable size gland plate / glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply install,testing and commissioning Street light feeder panel boards (KIOSK TYPE) out door use,dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-65) double shutter gears front and rear frame work and 3.15 thick MS sheet duly painted all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 100 amps capicity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:-(SL FP-5 for Pocket No-4) INCOMING: (i) MCCB, 4 pole, 50 Amps , 25 KA Therrmal magnetic release -01Nos (ii) Ammeter 0-100 Amps with CTs -01 (iii) Volt meter 0-500 Volts with selector switch -01 (iv) Indicating lamp -01 set OUTGOING: (i) MCB, 2 pole, 32 Amps , 10 KA -03 Nos (ii) Auto Timer Switch 1 Phase 32 amps - 02 Nos (iii) All out going feeders shall be connected by cable through suitable size gland plate / glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (v) Plate form for panel the panel with PCC 1:4:8 type D-32 with 40 mm graded crush stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class;B' old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
Supply installation testing and commissioning of potential tronsformer 33 KV single phase oil filled, self cooled hermatically sealed outdoor type fixed on existing steel structure & suitable for highest system voltage 36KV 50Hz frequency, PT of ratio 33Kv/rt 3/110v/rt3/110V/rt3 Class 0.5 -3 burden 50VA=50VA insulation level 70/170 KV voltage factor 1.2Cont and 1.94 30 sec confirming solidly earthed, lightning impulse withstand voltage 170KV, min creepage distance of porcelain housing 900mm, rated voltage factor 1.2 continuous and 1.5 for 30 seconds & temp rise as per IS 3156 or equivalent IEC complete in all respect and first filling of oil and complete testing.

1

-

-

... More
Supply installating testing & commissioning of currents transformer single phase, oil filled ,self cooled outdoor type suitable for 3 phase 33KV solidly earthed system complete as per IS-2705 (part I),II, III & IV - 1992) or equivalent IEC. It shall haveCT of ratio 400/5-5Amp Class 1.0-5P10 burden 15VA insulation level 70/170 KV as per IS-2705. Secondary currents rating 5/5/1 Amp for current metering & back up for O/C & E/F protection. The CT is to be fixed on existing steel structure with nut bolts etc complete as required & first filling of oil.

1

-

-

... More
Supply and fixing HT cable/route indicator cast iron of suitable size along HT cable trench including planting in ground with PCC complete all as directed.

10

-

-

... More
Supply and fixing LT cable/route indicator cast iron of suitable size along LT cable trench including planting in ground with PCC complete all as directed.

100

-

-

... More
Supply laying testing & commissioning of PVC copper armoured control cables suitables for system upto 1100V 50Hz A.C. supply. Confirming to IS 1554 (part I)1998 and its latest amendments if any the cable is to be laid in existing trey , in trench , in duct. The cables are to be properly marked and shall be provided with identification ferrules of Copper cable size 4 core 2.5 Sqmm

100

-

-

... More
Supply laying testing & commissioning of PVC copper armoured control cables suitables for system upto 1100V 50Hz A.C. supply. Confirming to IS 1554 (part I)1998 and its latest amendments if any the cable is to be laid in existing trey , in trench , in duct. The cables are to be properly marked and shall be provided with identification ferrules of Copper cable size 10 core 2.5Sqmm

50

-

-

... More
Supply laying testing & commissioning of PVC copper armoured control cables suitables for system upto 1100V 50Hz A.C. supply. Confirming to IS 1554 (part I)1998 and its latest amendments if any the cable is to be laid in existing trey , in trench , in duct. The cables are to be properly marked and shall be provided with identification ferrules of Copper cable size 6 core 2.5 Sqmm

100

-

-

... More
Supply laying testing & commissioning of PVC copper armoured control cables suitables for system upto 1100V 50Hz A.C. supply. Confirming to IS 1554 (part I)1998 and its latest amendments if any the cable is to be laid in existing trey , in trench , in duct. The cables are to be properly marked and shall be provided with identification ferrules of Copper cable size 4 core 4 Sqmm

100

-

-

... More
Supply, installing, testing and commissioning, factory made and tested, automatic power factor control panel (APFC Panel) out door type, floor mounted, cubical front opening type, The panel shall be of protection class IP-65 and made out of 3.15mm CRCA MS sheet and MS angle 40x40x6 mm thick frame, power coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of synthetic enamel paint over one coat of red oxide primer, including internal wiring with PVC insulated solid copper conduit cables, IS-694 marjed, 1100 volts grade of appropriate size but not less then 2.5 sqmm and comprising of the following:- (a) Incoming MCCB, LT, 4 pole, 250 Amp rating, 35 KA rupturing capacity :01 No (b) Capacitors type MPP-H as per IS 13585/hot I/1994/IS 13340/1993, for 120 KVAR (25x3+10x4+8x1+4x1+2x1+1x1) KVAR. (c ) Microprocessor based, modular type, intelligent APFC relay capable of having self adjustment to any capacitor value suitable to maintain power factor between 0.95 to 0.99 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps- 11 Nos Note :- (i) The APFC panel and all connected items mentioned shall be of the same make. (ii) The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specfically in all respects to high standards of engineering design and workmanship and shall be capable of performing in continous operation. (iii) indicating lamp -01 NO (set of three) (v) Multifunction digital electronic energy meter to measure KW KWH & KVAR & 300 amps 3 Phase 415 volts 50 HZ - 01 No.

1

-

-

... More
Supply, installing, testing and commissioning, factory made and tested, automatic power factor control panel (APFC Panel) out door type, floor mounted, cubical front opening type, The panel shall be of protection class IP-65 and made out of 3.15mm CRCA MS sheet and MS angle 40x40x6 mm thick frame, power coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of synthetic enamel paint over one coat of red oxide primer, including internal wiring with PVC insulated solid copper conduit cables, IS-694 marjed, 1100 volts grade of appropriate size but not less then 2.5 sqmm and comprising of the following:- (a) Incoming MCCB, LT, 4 pole, 250 Amp rating, 35 KA rupturing capacity :01 No (b) Capacitors type MPP-H as per IS 13585/hot I/1994/IS 13340/1993, for 100 KVAR (25x3+10x1+8x1+4x1+2x1+1x1) KVAR. (c ) Microprocessor based, modular type, intelligent APFC relay capable of having self adjustment to any capacitor value suitable to maintain power factor between 0.95 to 0.99 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps- 8 Nos Note :- (i) The APFC panel and all connected items mentioned shall be of the same make. (ii) The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specfically in all respects to high standards of engineering design and workmanship and shall be capable of performing in continous operation. (iii) indicating lamp -01 NO (set of three) (v) Multifunction digital electronic energy meter to measure KW KWH & KVAR & 300 amps 3 Phase 415 volts 50 HZ - 01 No.

1

-

-

... More
Supply, erection testing and commissioning of 33 KV isolator 3 pole single throw double break three posts per phase central pole rotating type manually operated in a horizental plane and shall have high pressure relieving type fixing contacts made of hard drawn electrolytic copper. The switchblades forming the moving contacts shall be made from tubular section of hard drawn electrolytic copper having suitable dia and thickness and shall be silver plated. Each isolator shall be provided with bimetallic clamping type of connector suitable for ACSR 0.2 Sq inch. The isolator shall have on, off indicator pad locking arrangements. It shall have the following parameters and shall be fixed on existing steel structure. Nominal system voltage 33 KV No of poles 3 Rated Voltage 36 KV Continuous currents 630 Amp Rated frequency 50 c/s One minute power frequency with stand voltage to earth and between poles 70 KV rms Impulse withstand voltage to earth and between poles 170 KV (peak value) One minute power frequency test voltage across isolating distance 100 KV rms Impulse withstand voltage across isolating distance 195 KV (peak value) Phase clearance (Phase to phase) 1220 mm Short time current rating 12.5 KA/ 1 Sec Rated peak short time current 2.5 times the short time current

1

-

-

... More
Supply , testing and commissioning of Electronic temper proof energy meter suitable for AC Single phase accuracy class 1.0 as per ISI 3779, 50 Hz with back light LCD display of rating 5-30 A including necessary fixing arrangement .

30

-

-

... More
Supply , testing and commissioning of Electronic temper proof energy meter suitable for AC three phase accuracy class 1.0 as per ISI 3779, 50 Hz with back light LCD display of rating 10-60 A including necessary fixing arrangement .

1

-

-

... More
Dismantling of existing two pole structure and accessories and depositing the same in MES stores

2

-

-

... More
Installing, testing and commissioning by OEM (i.e. Crompton Greaves) for outdoor type, step down power transformer, 33KV/11 KV AC 3 phase 50 Hz, 1.6 MVA capacity, core type, double Copper wound, oil immersed, naturally cooled, Oil Natural- Air Natural (ON AN) with external cooling tubes delta connected from primary side (HV), and star connected from secondary side (LV)in accordance with vector group DYn-11 and having tapings at (+) 5% to (-) 15 % in steps of 1.25 % each on HV side to be changed by on load tap changer gear locally and remote with RTCC Panel including repair/replacement of faulty/ damaged control wiring. The maximum temperature rise should not excced 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius as per ECBC norms. Intallation shoul be carried out as per IS-1180:2014 including Dehydration of transformer oil tested upto 60 KV dielectric strength at 2.5 mm air gap between testing electrodes at installation time. Installation includes the Servicing and Testing of following HT accessories by OEM (Original Equipment Manufacturer) including repair/repacement of required parts if any (a) Three Nos Porcelin bushing suitable for 33 KV on HV side complete with copper rods, nuts and washers and arching horns. (b) Four Nos porcelin bushing suitable for 11 KV on LV side complete with copper rods, nuts and washers and arching horns. (c) Oil filling holes with flanged bottom cover. (d) Oil conservator with filter and drain plug (e) Prismatic/ Transparent Oil Gauge (f) Dehydrating breather with first fill of dehydrating agent (Silica Gel) (g) Thermometer pocket (h) Air realese plug (j) Top filter valve (k) Drain cum bottom filter valves (l) On load tap chanmger with locking arrangement (m) Buchholts relay with alarm & trip contracts (n) Marshling Box (o) OTI (Oil Temp Indicator) & WTI (Winding Temp Indicator) with alarm and trip contact on HV and LV both side (p) RTCC (Remote Tap Changing control) Panel with AVR (Auto Voltage Regulator) (q) Magnetic oil level gauge with larm and trip contact ® Shut off valve for buchholts relay (s) Oil temp indicator dial type of 150 mm with alarm and trip contact capilary type Plateform : Plateform shall be provided as under: (i) Size of plateform shall be of 4.00 mx4.0 m x 0.30 m. PCC (1: 4 : 8) type D-2 , using 40 mm graded crushed stone aggregate in foundation shall be provided . (ii) Bricks work shall be in CM (1:6) with 10 MM thick plaster in CM (1:4) (iii) 100 mm thick padding in PCC (1:3:6) , Type C1 , using 20 mm graded stone aggregate shall be provided on top of brick wall (iv) Two no. ISMC 100 mm X 50 mm X 6mm shall be fixed on brick work for proper movement of transformer . (v)The height of platform shall be kept such that the top edge is achieved as 60 cm above adjoining road level. (vi) Installation of the transformer shall be carried out as per IS 1180:2014. Notes: (i) Transformer 1.6 MVA , RTCC Panel shall be issued by department as per Schedule B Part II. (ii) Item includes shifting of Transformer from MES Yard to Proposed Subsattion. (Appx Distance 50 Metre using necessary T&P and Lifting Crane etc.

1

-

-

... More
Installation, testing and commissioning by OEM (i.e. Crompton Greaves) for floor mounted 11KV HT VCB panel indoor type factory made three ways as per IS-3402, 12729, 13118 cap 630 amps with all HT accessories such as PTs, CTs, Protection device, motorised charged mechanism with indicating lamp, space heater with thermostat, electrolytic copper bus bar. including repair/ repacement of damaged internal control wiring. Installation includes the Servicing and Testing of following HT accessories by OEM (Original Equipment Manufacturer) including repair/repacement of required parts if any. (a) One No 96 mm square dial type, potential transformer operated, flush pattern voltmeter, rated 1 to 15 KV, with 3 way ON/OFF rotary type selector switch. (b) One No 96 mm square dial type, current transformer operated flush pattern ammeter dual range 1 to 50 Amps with 3 way ON/OFF rotary slector switch. (c) One No cast resin PT having rating 11 KV/110 volts with adequate VA burden and P fuse of suitable capacity (d) Three CTs 50-25/5-5 amps rating, cl;ass-I, VA burden 15 suiatble for 12 KV (e) One set of green and red pilot lamps to indicate ON/OFF position (f) One No Multifunction meter (g) Master trip relay (digital type) (h) High speed trip supervision relay (digital type) (j) One set of trip accept/ reset switch (k) switch for closing/ tripping of VCB (l) PT fuse failure relay Notes: (i) VCB Panel shall be issued by department as per Schedule B Part II. (ii) Item includes shifting of VCB Panel from MES Yard to Proposed Subsattion. (Appx Distance 1.0 Kms) using necessary T&P and Lifting Crane etc.

1

-

-

... More
Installation , testing and commissioning by OEM (i.e. Crompton Greaves) for SF6 Gas circuit breaker out door type including Control & Relay Panel (C & R Panel) single pressure puffer type 3 pole of rated voltage 33 KV and highest system voltage 36 KV ( r.m.s.) rated current 400 Amps, breaking capacity 25 KA operating time cycle of 3. This also includes Servicing and Testing of HT accessories by OEM (Original Equipment Manufacturer) such as Interrupter per pole mounted on hollow porcelin support, geared motor actuated spring loaded gang operated mechanism, marshling box and repacement of required parts/Gas if any. Notes : (i) SF6 Gas Circuit Breaker, Control and Relay Panel shall be used under Sch 'B' Part II. (ii) Item includes shifting of SF6 Gas circuit breaker & Control and Relay Panel from MES Yard to 33/11 KV substation of HQ SWC. (Appx Distance 1.5 Kms) using necessary T&P and Lifting Crane etc. (iii) Item includes Foundation of SF6 in PCC (1:3:6) , Type C1 , using 20 mm graded stone aggregate of size 2 X0.6X0.6 m including necessary foundation nuts & bolts.

1

-

-

... More
Supply and Fix street light fitting, LED as light source with pressure die cast aluminium housing of capacity 60 Watt. Make as specified in appendix B to particular specifications

106

-

-

... More
Supply and Fix street light fitting, LED as light source with pressure die cast aluminium housing of capacity 100 Watt. Make as specified in appendix B to particular specifications

30

-

-

... More
Supply, installation, testing and commissioning 11KV HT VCB panel factory made three ways out door type as per IS-13118 with 01 Nos. incomimg , & 02 Nos. outgoing set as per IS-13118 with all standard accessories and including and comprising of followings :- (At Proposed 33 KV Yard SWC Ph-I) (a) Rupturing capacity 350 MVA of rating upto 630 Amp, 18.4 KA VCB ; CT Ratio : 150-100-50/5-5A (Incommer) - 01 No. (b) Rupturing capacity 250 MVA of rating upto 400 Amp, 18.4 KA VCB, CT Ratio : 100-50-25/5-5A (Outgoing) - 02 No. Note for Item No - 17 (the following feature shall have with each VCB unless otherwise not specified separately) :- (i) Continous high conductivity electrolytic copper bus bar, Raychem Insulated for full voltage ,phase identifcation made at the end by colored tape , bus bar shall be mounted on intergral seal off bushing and interconnection with electrolytic grade copper with joints silver plated. (ii) Circuit breaker shall be mounted on a withdrawable truck which shall be horizontally drawout from service position to isolated position . (iii) Motorised Spring Charged Mechanism. (iv) Cast Resin Current Transformer ,11Kv ,5-5A ,15VA,Cl 5P10,Cl 0.5 - 3 Nos (v) Cast Resin Three phase Potentail Transformer 11Kv/√3/110V/√3,100VA , Cl 1.0 - 03 Nos with desired capacity PT Fuses (only with incomer VCB) (vi) Accessories like local remote selector switch , Breaker Control Switch ( TNC) ,space Heater with Thermostat, DC & AC Control Ckt through MCB,Indicating LED lamps for R Y B Phases,Spring Charged, DC Supply Healthy, Breaker ON/OFF, Breaker in service ,Test, Disconnected position (v) Multi function meter - 1 No (vi) 1 No of SCADA Compatible Feeder Protection Relay 50/51(3 phase overcurrent) , 50/51N ( Earth overcurrent) , 67P (3 phase directional overcurrent), 67N (Earth fault directional overcurrent) , 51V ( Voltage controlled overcurrent) , 37 ( 3 phase undercurrent) , 46 ( Negative phase sequence overcurrent) , 59N ( Residual over voltage) , 32 (Directional Power protection (Under/ Over active/ reactive power)) , 81U/O (Under/over frequency) , 49 (Thermal overload), 79 ( Autoreclose), 50BF ( Circuit breaker failure detection) , Cold load pick up, Inrush blocking. Relay will be on Modbus Protocol ( Not required with Bus coupler) (vii) High Speed Master Trip Relay – 1 No (vii) High Speed Master Trip Relay – 1 No (viii) Trip Circuit Supervision Relay – 1 No (ix) PT Fuse Failure Relay -1 No (x) Anti Pumping Relay -1 No (xi) Air insulated rear end Bottom entry cable box suitable for termination of XLPE Cables .

1

-

-

... More
Installing,testing and commissioning outdoor type, step down, transformer, 11000/415 Volts , AC 3 phase 50 Hz capacity 160 KVA, core type , double copper wound, oil immersed , naturally cooled, oil Natural, Air Natural (ONAN) , with external cooling tubes, dlta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vactor symbol DYN -11 (Vector Group) with neutral brought out on secondary side (LV side ) and having tapping at + 5% HV side to be changed by means of hand operated off load tap changer gaear including T&P required for making necessary arrangement for Dismantling, Shifting and installation of transformer 160 KVA from Signal Area to Proposed MT Site. The Installation of transformer shall be IS : 1180:2014 marked and shall comprise of the following: Plateform : Plateform shall be provided as under: (i) Size of plateform shall be of 4.00 mx4.0 m x 0.30 m. PCC (1: 4 : 8) type D-2 , using 40 mm graded crushed stone aggregate in foundation shall be provided . (ii) Bricks work shall be in CM (1:6) with 10 MM thick plaster in CM (1:4) (iii) 100 mm thick padding in PCC (1:3:6) , Type C1 , using 20 mm graded stone aggregate shall be provided on top of brick wall. (iv) Two no. ISMC 100 mm X 50 mm X 6mm shall be fixed on brick work for proper movement of transformer. (v)The height of platform shall be kept such that the top edge is achieved as 60 cm above adjoining road level.

1

-

-

... More
Dismantling of Main LT panel complete including connected assessories

2

-

-

... More
Dismantling of feeder piller box complete including connected assessories

6

-

-

... More
Dismantling of old U/S street light fittings any type, any size complete

26

-

-

... More
Removal of LT UG XLPE cable

300

-

-

... More
Taking down U/S earthing assessories

0.6

-

-

... More
Taking down U/S GOD

2

-

-

... More
Taking down U/S lightening arrestor

2

-

-

... More
Material and labour for Heat shrinkable type straight through cable jointing kit, , HT 33 KV grade complete with jointing material suitable for HT XLPE, cable of 185 sqmm 3 core 33 KV(E) grade, complete all as specified and directed.

4

-

-

... More
Taking out carefully cable cover from trenches

8200

-

-

... More
Relaying of cable cover cover

4100

-

-

... More
Supply and fix blank plate of module 1

6

-

-

... More
Supply and fix metal flush box of 8 module

12

-

-

... More
Supply and fixing PVC insulating mat 1.0 mtr width and 3.0 mm thick as per IS : 15652-2006, 33KV class 'C' all as specified and directed by Engr-in-Charge. Make Delco or equivalent make as specified in appendix B to particular specifications.

12

-

-

... More
Supply and packing with Pea gravel of 4.6 mm to 8.0 mm size approved quality as ordered to packed around the casing/slotted pipe in bore well complete all as specified and directed by engineer-in-charge

60

-

-

... More
M & L for lowering 80mm bore GI medium grade pipe 600 cm length(depth) each side (02 Nos) with screwed cap for feeding pea gravel all as required for completion of work

3

-

-

... More
Supplying, installing, testing and commissioning electric motor driven (PP/FRP construction) Bleaching powder doser confirming to IS - 10553 Part-4 with all accessories with venturi test pressure 4KG/ working pressure 3.5 KG of capacity of 217 Ltrs including accessories for bleaching powder solution doser such as 15mm P flange end diaphram valve, 15mm PP screwed end diaphram valve, 15mm connection PP funnel, 15mm PP flanged nipple, 15mm flange only, 15mm dia transparent flow indicator, 15mm dia feed water/ drain water GM valve,3/8" or 1/4" dia Air release cockwith 6" long nipple, 15mm dia PVC braided hose, 15mm hose adaptor (brass), 1/2" or 3/4" hose clip, 15mm dia GM check valve, MS rubber lined head for wheel type doser CI top plate for funnel type doser, complete fitting for bleaching powder solution doser and also connecting up with existing rising main as per make as specified in appendix B to particular specifications.

1

-

-

... More
Supplying, installing, testing and commissioning of Calcium hypochlorite- Chemical dosing Pump, Gear motored having output 06ltrs/hr @10kg back pressure, power 230 volts, 50Hz, RPM-44, self priming non metallic with connecting nuts, Ferrule, and with all accessories consisting of 100ltr FRP tank with PE/RRP LID & level gauge along with agitator with shaft and blade and connecting accessories including three plastic drum (40/45kg) of calcium hypochlorite 65-70% (high strength calcium based granular chlonation chemical) of Make as specified in appendix B to particular Specifications.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.