Jodhpur Vidyut Vitran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
Refer DocumentsDocument Cost
₹ 2,950Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_JVVNL_214607_1Bid Award Id
ViewTender No
JPD/ZCE(J/Z)/TN-07Tender Authority
Jodhpur Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://energy.rajasthan.gov.in/content/raj/energy-department/jodhpur-vidyut-vitran-nigam-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(3.1) 9 Mtr/1.2 mx0.6mx1.50m deep
2
-
104.29
(B) Lattice Tower /Size of pit:-
-
-
-
(3.2)12.8/12.6 Mtr/ 1.5mx1.5mx2.10 m deep
203
-
361.85
( c ) Stay set/Depth of pit:-
-
-
-
(3.3)8'x3/4 -0.75x0.5x1.6m
159
-
81.53
(4)Safe carriage of PCC poles including loading / un-loading
-
-
-
(a) 9 Mtr Long 400 Kg / 11 Mtr PCC pole
(4.1) with in 10kms
2
-
236.27
(5) Safe carriage of steel (fabricated and unfabricated) l.e. M.S Rails R.S Joists . M.S Channels ,M.S Angles, M.S Flat, G.I stey set, G.I Stay wire , G.I wire Nut & Bolts etc. And ACSR Conductor including loading and unloadign and stacking in Nigam store/ at work site.
(a) with in 10kms
30
-
332.02
(6) Safe carriage of insulator hardware cable etc. Including loading/ unloading and stacking in Nigam stroes. Etc. (a) with in 10kms
40
-
397.93
(7) Safe carriage of fabricated lattice. Towers structures and sub-station structure type AB, AB beams isolators structures etc. Including loading/ unloading and stacking in the Nigam stores /at work site.
(a) with in 10kms
101
-
484
(8) Erection of PCC poles in excavated pit with fixing of brackets. Cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
(B) In Rural Area
-
-
-
(8.1) PCC poles 9 Mtr Long (400Kg)
2
-
458.72
(9) Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete to ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra. (a) Lattice Structure
101
-
4984.26
(10) Erection & fixing of G.I stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension. Size of stay set /stay wire.
-
-
-
(10.1) 8"x3/4" with 7/8 SWG Stay wire
159
-
284.27
(11) Providing and laying cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm grade blast crusher broken in pit/ foundation according to the size/ type of supports/ stay set including compaction / curing for 21 days in steel plates shuttering / farmer base
609
-
2879.19
(12) Fixing of 11 KV B&S / T&C disc insulator for 33 K.V lines (each unit consiting of 3 nos disc. & 1 set of H/W) on terminal point including fixing of hardware and strips
270
-
47.88
(13) Fixing of 33 KV pin insulator with pins
843
-
15.16
(14) Fixing of PG clamp of Dog/ Racoon Conductor
1232
-
5.06
(15) Fixing and assembly of disc. Point channel pair with pilot plates & clamps on erected double pole structure as per design. The nuts & bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
(a) 33 KV line
109
-
138.58
(16) Fixing of Danger plate on supporters/structure
203
-
7.58
(17) Laying jointing stringing tensioning and clamping of conductor with proper sag as directed using bolted type hardware including binding on pin insulator jumpering on section points with binding wire / PG clamps Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G clamps for which payment will be made as per prevailiing Discom issue rate.
(a) In Urban Area
(17.1) ACSR DOG
33.9
-
2972.11
(18) Laying jointing stringing tensioning and clamping of G.I Earthwire continuosly on single/ double pole by using earth clamps/ nuts & bolt with washers and earth reel etc. Including proper binding at each end. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
(a) In Urban Area
(18.1) G.I Earth wire 8 SWG
11.3
-
872.1
(19) 3Earthing of line for all type of supports as per REC construction standards using stay wire/ G.l wire one pcs. M.S rod 20 mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing & specification.All meterial except MS rod, MS flat & stay wire will be supplied by the contractor if material is supplied by the contractor the payment will be made as per prevailing Discomstore issue rates . (In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)
53
-
341.79
(20) Laying of 33 KV XLPE cable with out Road cutting i.e. Through burrowing machine 'VERMIER' (120 cm deep) use of this technology must be restricted to the situation like.
(ii) when the road side cutting is not permitted by the local administration.
(a) 33/11 KV 3C x300 Sq. Mm cable
2000
-
308.2
(21) For Extra Loop (Ghera) to be provided near the pole on termination point and the lenghth of cable along the pole for mounting of cable jointing kit.
(a) 33 KV Cables :-
-
-
-
(21.1) 3x240Sq. Mm to 3x400 Sq. Mm
260
-
227.84
(22) Installation of cable termination/ straight through joints on 11 KV Aluminium conductor XLPE/ PILCA Cable with outdoor / indoor termination end and / or straight throught joint including requried excavation/ remoral/ fixing / refixing/ testing etc. required.
-
-
-
(a) Outdoor end terminal:-
(22.1) 3x240 Sq. Mm to 3x400 Sq mm
8
-
1228.68
(b) Indoor end terminal:-
(22.2) 3x240 Sq. Mm to 3x400 Sq mm
6
-
1179.82
(23) Assembly installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
(a) G.O switch with earthing blade.
-
-
-
(23.1) 33 KV G.O switch
2
-
1260.18
(24) Fabrication of steel structures of M.S angle M.S channel & M.S Flat including cutting, drilling and continuous welding joint as per design and drawing.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements