Indian Oil Corporation Limited Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Indian Oil Corporation Limited - IOCL Tender

Works
Coronavirus COVID 19
Eprocure

Opening Date

13 Jun 2019

Closing Date

1 Jul 2019

Tender Amount

₹ 79,91,102 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Transformer : General Inspection & replacement of blown off fuses etc., Checking of Oil leakage, Condition of silica gel. Oil temperature/Winding temperature, Load (Amperes), Cleanliness of Transformer & Busbar duct. Checking of Overheating, and sparking (of contacts), Oil level and oil leakage, Earthing connections, and overhead earth mesh (whichever applicable). Any other jobs as advised by officer in charge.

36

-

5621.579

... More
HT, ACB/ VCB Stabiliser & Others : Preventive/ breakdown maintenance as and when required for HT (33 KV) structure/Panel, Transformers, Operation of A/B switch, lightning circuits as and whenever required. VCB/ACB panels, Capacitor Banks, Maintaining power factor not less than 0.95 etc. Interchanging the blue & yellow phases whenever there is a change in the OSEB phase rotation. Cleaning the stabilizer with dry cloth (daily). Adjusting the settings of the Transformer/Stabiliser as and when required. All checks/inspections as OISD-137 , OEM recommendations & IOCL M&I formats have to be carried out & records to be maintained. Any other jobs as advised by officer in charge. Material to be supplied by IOCL.

36

-

6212.5175

... More
Panels & Others : Preventive/ Breakdown maintenance & operation of all LT panels, LT ACBs Lighting panels, distribution boxes, LT circuits, PFC panel, UNICOS panel as and when required, Changing of defective fans, tubes & bulbs. Changing of chokes, capacitors, MCB, ELCB and fuses as & when required, Checking the circuits for communication system. Computers, Tank Farm Monitoring system, UPS, LAN etc., and attending to all problems thereof, Cleaning the Filter of (A/C) as & when required, Checking the circuit of A/c, Fridge, Water coolers and attending to all minor problems, Repairs / replacement of Circuits, Starters, Motors, including that at of Fire Engine panels, Highmast, flood light, Tower lights, Yard lights, FLP fittings, Domestic lights and appliances, fans etc., as and when required. All checks/inspections as OISD-137, OEM Recommendations & IOCL M&I formats have to be carried out & records to be maintained. Any other jobs as advised by officer in charge.

36

-

6212.5175

... More
Battery : Checking General cleanliness of battery room, Functioning of ventilation system, Formation of acid vapours in room, Spillage of electrolyte, Level of electrolyte, Cell voltage and proper connections for correct polarity, Specific gravity of cell. Check Availability & condition of safety equipment (such as rubber apron, goggle, and acid proof hand gloves), Caution boards ("No smoking") etc., Condition of acid -proof flooring, Joints, terminal and bolted connections for tightness (full electrical contact) Blockage of vent plugs, Corrosion effects on terminals and connectors, Condition of supports (racks), Damages such as cracks in containers, Capacity test

156

-

1858.8854999999999

... More
Charger & DC board : Check for General cleanliness, Ventilation system, Float voltage & charging current Overheating, External damages, Tightness of connections, Condition of contactors and switches, Operation of charger circuit with annunciation.

36

-

3830.0696999999996

... More
UPS & Inverter : Condition of ventilation and detection of any overheating, Any other inspection recommended by the manufacturer, All UPS connected to Computers to be checked for working & repairs.

156

-

1915.0424

... More
ELCB : Checking ELCB for Corrosion effects (external), Functioning of lamps and meters, illumination in critical areas, Condition of conduits, Junction boxes

36

-

1915.0424

... More
Pumps & Motors: (Jobs which are not covered in AMC) Checking of Mechanical freeness of rotor shaft, Testing and certifying the IR Values of all Cables, Motors & Pumps, Checking Vibration of Pumps/Motors and recording, Earth resistance and continuity, Operation of Space heater, Interlocks/Trips, Annunciation circuits, Availability of all protective devices and circuits in line as per design, and all in operating condition. Condition of remote tripping devices & limit switches, Oil level in lubricating gear case. Internal damage, discolouration and loose connections, Condition of supporting legs, pedestal and base plate, Condition of the foundation and tightness of foundation bolts, Any carryover of oil or grease inside the windings, checking the vibrations of pumps & motors. Power supply to pump and motors as per operational/ maintenance requirement. Assisting to AMC vendor during AMC of the equipment.

36

-

6212.5175

... More
Capacitor & APF panel / Relay & Meters : Checking Dielectric strength and acidity of oil of Transformer in the approved lab as advised by IOCL (If applicable), testing charges in Lab to be born by IOCL. Checking Tightness of wiring connections of Capacitor & APF panel, Changeover circuit operation of relays, Contacts (for pressure, alignment, free operation, freedom from corrosion and burning effects),

6

-

4764.8956

... More
Cable & Wiring : Checking Availability of permanent cable route markers and joint location markers, Condition of cable termination / joints and clamping arrangements. Providing mechanical protection to under ground and overhead cables (especially for energised cables). Insulation resistance (IR) value to be measured once in a year or as required. Carrying out Insulation deterioration test(Polarisation Index Test), Continuity tests. Replacement of damaged cables, conduits, wires including clamps/cable supports. Contractor to avoid/ rectify congestion of cable in the duct (conformity for pipe fill 50%), Damages to cable trench including covers, duct and tray support. Cable trenches & ducts are to be cleaned on half yearly basis. Providing electrical connection to any new equipment installed/ shifted inside the terminal.job includes proper termination and glanding of power cable , earthing of equipment, laying of cable trays and proper dressing of cables. IOCL to provide the materials.

6

-

10721.0151

... More
Earth Testing: Maintenance and treatment of all earth pits to keep the earth pit value within limits. The treatment material shall be provided by IOCL and manpower to be engaged by the cotractor. Testing of Earth pits by earth tester and submitting reports and stenciling the details on the pits (Twice in a year and as and when required) including earth pits of solar panels. Approx. 170 earth pits.

6

-

12040.438

... More
Outdoor Switches : Checking Earthing of fencing, gauge, insulator supports and other metallic structures, Condition of fencing & all metallic structures from corrosion effects, Provision of locking arrangement for gate and isolators (especially when the transformers & O.H. line are energised), Provision of metal jelly oil soak pit and fire partition walls (as applicable), Condition of trenches cover slabs and earth electrodes in the yard, Accessibility for maintenance and operation of switchyard equipment with component parts, General illumination

36

-

1786.8434

... More
Substation : Checking of General illumination, Emergency lighting provision and its auto -changeover circuit operation, Ventilation, Roof leakage, Sealing of cable and bus duct entries (to make them water & vapour tight), Water drainage arrangement, Provision of rubber mats, shock treatment chart, fire extinguisher (suitable for electrical fires), sand filled buckets, break -glass fire alarm station and telephone (for internal and external communication), Condition of trench, cover slabs, and chequered plates. Marking on the switchboard, for the identification of circuits and provision of danger, caution boards, Damages and corrosion effects if any

36

-

961.9605999999999

... More
Relays / Meters & Starters / HT/ Earthing / Cable & Wiring : Relay operation under fault conditions simulated (primary injection), Sealing cable trenches/ducts (prevention of entry of foreign materials-vermin, water, chemicals, dirt, reptiles, etc into trenches, ducts), Corrosion on the metallic tray supports, Visual check for external damages to earth electrodes down conductors, lightning arrestors, supporting structures and insulators, Checking Continuity of Earthing conductors, Bonding and Earthing of all metallic structures, pipe racks. Armour of cables, and electrical equipment enclosures, Earth loop impedance (measurement), Process equipment in the plant area (such as heat exchanger, vessel, column, piping etc.) whether grounded, Liasion with External agency & assist for Checking and calibration of all relays (LT & HT) and meters (KWA/KVA demand, ammeter, volt meter),

3

-

10718.7199

... More
Maintenance of Solar Power Panels & cells- Check for proper functioning of solar panels everyday. Panel suface to be cleaned and kept free from dust MONTHLY. Records of readings from Solar Power Panel to be maintained properly. Any maintenance and repair activity related to solar panel to be carried out as directed by IOCL official. Material to be provided by IOCL.

36

-

1191.2239

... More
Testing of electrical continuity of Hoses of Terminal and all Tank Trucks and submit a report as per the format given by IOC.

36

-

595.6195

... More
Round the Clock Fire Engine operation (as & when required) & Maintenance of Fire fighting equipments.

-

-

-

... More
Maintenace of Fire Fighting Equipments in Field/Stores/Fire Equipment Room, PPEs, Portable 200 liter Foam Trolley and HVLR. Round the clock presence for operation of Fire Engines, Jockey pumps at the time of need. Ensuring the availability of Fire Fighting Equipments in designated place.

36

-

16081.5151

... More
Operation of Diesel Engine Driven Fire Pumps (Six nos) for 30 Mins (Each Engine twice in a week) by opening one hydrant or monitor by keeping the hydrant system in Auto mode twice per week as per OISD. Maintaing relevant records in the IOC provided log book.

36

-

3573.6717000000003

... More
Topping up of HSD in fuel tanks of fire engines & DG sets to always keep the tanks in Full condition.

36

-

1191.2239

... More
Assisting Vendor in servicing of Fire Engines.Undertaking Daily, Monthly, Qtrly & yearly Maintenance Schedule of Fire Engine. Cleaning of radiators & maintaining records their off.

36

-

1191.2239

... More
Daily checking of Auto Functioning of All Fire Engines(Six nos) & Jockey pumps(Two Nos), Sequencing operation of all fire pumps & all electrical panel. External cleaning of Fire Engine,Jockey Pump , panels & cleaning of base tiles etc.

36

-

1786.8434

... More
Routine & preventive Maintenance of Gland packing of Fire Engine & Jockey pumps (Material Supplied by IOC.) (Two pumps - Quterly Checking)

36

-

2382.4478

... More
Ensuring leak free operation of total Hydrant system & Foam system on daily basis. Flushing of Hydrant line to be done in every fortnight or recirculation of line water to be done.

36

-

2382.4478

... More
Preventive maintenance & checking of Batteries, Nonreturn valve, Lube Oil Level,Fuel Oil level etc & required topping up as & when required. (Material cost will be bonre by IOC)

36

-

2382.4478

... More
Greasing & servicing of valves of Double Hydrants (DH), Water Monitors (WM), Water cum foam monitors (WCFM), HVLR, P-HVLR & isolation Valves (appx DH -30, WM-26, WCFM-13. HVLR-06, P-HVLR-03 and 33 no isolation valve and any other safety related equipments. Material will be supplied by IOC. Greasing to be done once in a month & record to be maintained (111X12)

3996

-

130.766

... More
Preventive Maintenance & testing of Sprinklers of 3 nos of IFR Tanks and upcoming furture Tanks. Cleaning the chocked nozzles, replacing the damaged nozzles. Sprinkler should be tested once in a quarter & record to be maintained in IOC provided log book. (Material cost will be born by IOC)

12

-

4828.9951

... More
Topping up of the 2 numbers of AG Water storage tank by operating the Deep Tube well and required valves on daily basis. The dips of both the water tanks to be taken on daily basis & to be posted in Fire Engine log book & to be countersigned by DSO.

36

-

1915.0424

... More
Assist in Monthly Fire Drill,Disaster Drill,Daily Safety Checks,Daily Safety Talk, training etc. Putting back the used DCP/CO2 to Servicing Yard. All Fire fighting equipments back in their designated place.

36

-

1191.2239

... More
Preventive maintenance , testing & servicing of all foam pourers of product tanks. Foam Pourers to be tested once in a quarter. (Material will be supplied by IOC)

12

-

3637.7711999999997

... More
Preventive Maintenance & checking of 9/10 kg DCP Type Fire Extinguishers(109 Nos),75 kg DCP type FEx (07 Nos), 25 Kg(20 nos), CO2 Type Fire Extinguishers(2 kg -18 nos & 4.5 kg-10nos=28 Nos) & MEFG (8 nos.). Preventive maintenance of DCP includes Checking of Nozzles, Weight of Cartridge, Replacement of powder etc. Painting of the checking date on the body of Fire Extinguisher as per IOCL Provided format (172X4). Submission of checking record in IOC provided format.

2064

-

400.37649999999996

... More
Checking of Fire Pumps (6 Nos) for its performance by opening required nos of Hydrant/Monitors to verify the performance in rated capacity, discharge pressure,flow rate etc. Half Yearly or as and when required. Assisting AMC Vendor.

6

-

1786.8434

... More
Checking of Fire Engines (6 Nos) for its performance once in a year by running the fire engine continuously for four hours by opening the bypass line to water tank to verify the performance in rated capacity,discharge pressure.flow rate etc. Assisting AMC Vendor.

18

-

1786.8434

... More
Testing of stand by Jockey Pump on weekly basis & monitoring of the start/stop duration & holding of the pressure (7kg) in Hydrant line at the furthest point. Record to be maintained in IOCL format

156

-

595.6195

... More
Testing/Cleaning of First Aid Fire Fighting Equipments and the trolley on monthly basis including stacking & maintaing stock in the provided format.

36

-

595.6195

... More
Filling of foam concentrate in foam tank-3 KL (2 No.), 4 KL (1 No.) & 200 Ltrs moveable foam trolley (02 Nos ) as & when required. Shifting of foam from stores & Positioning at the designated places including stock staking.

36

-

2978.0673

... More
Testing Fire Hose (85-100 Nos.) once in 6 months at a pressure 1.5 times of working pressure. i.e.10.5 kg/cm2

600

-

320.4975

... More
Maintenance of First Aid Boxes which includes checking the expiry date of the items, replacing if expired, replenishing the used items etc. Materials will be supplied by IOCL.

36

-

595.6195

... More
Cleaning of strainers in Fire Hydrant system ( Fire Engines, Water sprinkler, Foam Bladder Tank) and date to be stenciled on the strainer.

192

-

160.25629999999998

... More
Operation of Fire Siren and Testing of Hand sirens once in a week and their maintenance, ensuring that they are always in working condition.

36

-

1281.99

... More
Assisting vendor in calibration of Pressure gauges, Pressure Switches, Pressure/ Temperature Relief Devices, PV Valves, Temperature gauges, Tachometer etc. and in maintenance/repair of VHF sets.

36

-

640.995

... More
Round The Clock compressor operation (as & when required) & Maintenance of Air pipeline & the equipments

-

-

-

... More
Maintaining the online compressors round the clock , checking the airline for any leakage and arresting the leakage. The airline to be maintained at it's set pressure for the fileld equipments. Maintaing the motor and the panel for the compressor or any other required works as per direction of LIC.

36

-

3845.97

... More
MISCELLANEOUS

-

-

-

... More
Extended working Hours beyond normal working hours/ holiday working on account of emergency etc. and any other works in the work schedule (appx 20 Hrs/man/month) 7 workmen

5040

-

131.75

... More
Extended working Hours beyond normal working hours/ holiday working on account of emergency etc. and any other works in the work schedule (appx 20 Hrs/man/month) 1 supervisor

720

-

154.25

... More
Electrical and technical maintenance (For the items which are not covered in AMC) of the equipments in TLF like BCU, PD meter, DCV, JBs, command switch and indication lights of BCU, Bulbs etc. Job includes replacement of fused bulbs, changing of indication light of BCU, openeing of BCU and closing it properly after maintenance, proper cable terminal & glading at TLF JVs and other connection, ensuring FLP fitting in proper condition, fixing of wooden stopper, crocodile clip of buckets of all areas & clips of all body earthing wire and other jobs as directed by officer in-charge. Material to be supplied by IOCL

36

-

3845.97

... More
Electrical/ minor technical maintenance (For the items which are not covered in AMC) of ROSOV, DBBV, all pumps in PPH, FPH; air compressors, DG sets, HVLR, ACs, Water cooler/ purifer, TAS/ equipments, CCTVs, blue dye dosing pumps, additive dosing pumps, all pressure gauges and any other equipments as directed by IOCL officials. Assisting the AMC vendors of the above said equipments during annual maintenance. Assisting in various inspection of the terminal by any internal or external team/ agency.

36

-

5621.58

... More
Cleaning of Panel: Cleaning of automation panels, Panels of PMCC building, transformer room, VCB room, fire pump house, Jockey pumps, VCB,air compressor, DG sets etc. Job includes cleaning of the panels as well as machines/ equipments using cottons or vaccum cleaner as directed by IOCL officials.

36

-

5021.29

... More
Carrying out electrical maintenance work at Officer's and staff transit camp, colony of IOCL (Whichever applicable) at Jharsuguda, as and when required on call basis. IOCL to provide the material.

36

-

1960.36

... More
Electrical and minor technical maintenance (For the items which are not covered in AMC) of Pumps of newly installed mechnised OWS, VRS unit. Material to be supplied by IOCL. Assistance to AMC vendor for maintenance of these facilities.

36

-

1933.97

... More
Carrying out non-routined incidental work related to drilling, cutting, grinding, welding, nailing etc as directed by IOCL officials. Material to be provided by IOCL. Providing power connection to machines/ equipments of contractors awarded with work orders to carry out various jobs inside the terminal as directed by IOCL official. To carry out any other jobs as assigned by LIC/ DSO Jharsuguda Terminal for smooth & safe operation of the terminal.

36

-

4829



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.