Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Bharat Sanchar Nigam Limited - BSNL Tender

Works
Security and Emergency Services
Eprocure
Opening Date1 Apr 2024
Closing Date9 Apr 2024
Tender Amount₹ 1,07,181 
Notes
Download

Costs

Summary

Sitc Of Fire Detection Panel , Rectification Of Existing Automatic Fire Detection And Fire Alarm System N Refilling Of Fire Extinguishers At Telephone Bhawan, Puri.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation testing and commissioning of following Zones UL listed Microprocessor based Fire Alarm Control Panel Made of 16/18 SWG CRCA sheet powder coated, finish suitable for operation with 220V 50HZ AC mains power supply with standby battery backup 24Volt DC power supply and built in charger (without batteries) , normal operating voltage 24 v DC, compatible with all types of conventional detectors, manual call points and normally opened dry contact devices, 16X2 Dot matrix display, fully compatible with UL-864 and NFPA-72 etc. complete as required as per details specifications. (make- Agni Instruments / Agni Devices/GST / Honeywell / system sensor / Ravel)

-

-

-

... More
4 Zone Local panel without PA system

2

-

-

... More
6 Zone Local panel without PA system

1

-

-

... More
SITC of 12V sealed maintenance free battery of not less than 7AH capacity with all accessories etc as reqd.(Exide /Amco/Superior)

2

-

-

... More
Supply, installation, testing and commissioning of UL listed, CE certified 2 wire conventional Photo electric / Ionization type Smoke detector with base (Blinking LED type) made of ABS plastic with all accessories, suitable for operation on 24v DC, internal protection class: IP23, dual pulsing LED with 3600 visibility, relative humidity: ≤95%;non-condensing and EN54 compliance of approved make etc. as required. (Make- Apollo / GST/ Honeywell / System sensor)

12

-

-

... More
Supply, installation, testing and commissioning of UL listed, CE certified 2 wire conventional Multi detector (fixed cum rate of rise heat Detector using a thermistor, raises an alarm when the detector reaches 590C (Fixed) or when the change in temperature exceeds the rate of rise of 110C/min) with base (Blinking LED type) made of ABS plastic and all accessories, suitable for operation on 24 v DC, internal protection class: IP23, dual pulsing LED with 3600 visibility, relative humidity: ≤95%;non-condensing and EN54 compliance of approved make etc. as required. (Make- Apollo / GST / Honeywell / System sensor)

2

-

-

... More
Supply, installation, testing and commissioning of electronic hooter cum speaker made of 16/18SWG CRCA sheet duly powder coated with PO red colour, output not less than 80db @25mtr, LMT with adjustable sound output of 2.5 watt,5 watt, suitable knock out for cable entry from top suitable for operation on 100/70 volt RMS AC supply etc. as required. (Make- Apollo / Honeywell / GST/ system sensor/ Ravel /Agni)

2

-

-

... More
SITC of manual push button station(pill box) Manual Call Point in MS Housing for Conventional Fire Alarm System with glass for breaking up in case of fire and hammer with chain etc. (Make- Apollo / Honeywell / GST/ system sensor/ Ravel /Agni)

3

-

-

... More
Supply and laying of 2 core 1.5sqmm FRLS PVC insulated and PVC sheathed copper conductor armoured cable on surface/recess for looping the fire alarm devices & providing power supply to sounder cum strobes etc. as required. (ISI)

20

-

-

... More
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. a) 2 core, 6 Sq. mm (19mm)

4

-

-

... More
S/F ABS round box / MS Box on ceiling for fixing the detectors etc as reqd.

5

-

-

... More
Supplying & Fixing of wall mounted Autoglow Signage Fire Exit Sign Board 3mm PVC Sheet with high Glow intensity in total Darkness. (Red and Green colour with exit symbols as per requirements)

150

-

-

... More
Refilling of following capacity CO2 type fire extinguishers with fresh /sufficient quantity / quality of CO2 with proper weight and measure, labeling with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities. Re-fixing the same in proper position and location as per the requirement of the location and type of fire extinguisher .

-

-

-

... More
4.5 KG CO2 type Portable Fire Extinguisher

4

-

-

... More
Hydraulic Pressure Testing of 4.5 capacity CO2 type Fire Extinguishers as per IS: 5844 -1970 (Reaffirmed 2006) and submission of Test certificates etc. as required.

4

-

-

... More
Providing and fixing of Gas Discharge Hose & Horn for following capacity Co2 type Fire Extinguishers.

-

-

-

... More
For 4.5 KG CO2 type Portable Fire Extinguisher

2

-

-

... More
Providing and fixing Gun metal regulating valve with safety washers for 4.5 Kg capacity Carbon Dioxide type Fire Extinguishers as per BIS specifications. {(IS: 3224:2002 (Reaffirmed 2007)} (The dismantled scrap material may be retained by the agency)

1

-

-

... More
Providing and fixing MS clamp for fixing CO2 4.5 Kg capacity capacity fire extinguishers on wall etc. as required.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.