South Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

South Central Railway - SCR Tender

Goods
Machinery and Tools
Ireps

Opening Date

2 Jul 2024

Closing Date

25 Jul 2024

Tender Amount

₹ 45,66,757.6 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Supply of relay fixing frame for Full location box, the frame should be made out MS angle of 25mm X 25mm X 3mm and approximate size of 940mm X 150mm with suitable holes to fix the same in the box." Inspection by consignee

32

591

18912

... More
"Supply of Electric Key Transmitters single complete to drg.no.SA.22601/Alt- 4& IRS S.21/2001 to ward no. specified.". Inspection by consignee

8

4767

38136

... More
"Supply of Relay AC immune, plug-in-type Style 'QNA1, DC neutral line, 24V, 8F.8B contacts, front 06 and back contacts metal to carbon with plug board retaining clip and connectors confirming to BRS 931A, IRS- S60, IRS-S34 and IRS-S23 (as applicable). The interlocking code for this unit shall be ABDGH.(with ATC clips)" Inspection by RDSO

64

3173

203072

... More
Supply of Relay AC immune, plug-in-type Style 'QNA1, DC neutral line, 24V, 12F.4B contacts, front 07 and back contacts metal to carbon with plug board retaining clip and connectors confirming to BRS 931A, IRS- S60, IRS-S34 and IRS-S23 (as applicable). The interlocking code for this unit shall be ABDFH. Inspection by RDSO

64

3143

201152

... More
"Supply of point contactor relay QBCA-1 AC immunized miniature plug in type DC biased 08 contractor, attractive armature 24Voits DC with 2HF/4B contacts, Heavy duty front contact, contacts metal to carbon complete with plug board, retaining clips and connectors to specification. BRS 943,IRS.S@ 46"44@IRS.S.23 as applicable". Inspection by RDSO

32

6859

219488

... More
Supply of Battery Charger 230V AC /24-26V-28V DC 30 Amps Capacity. RDSO Specification No.IRS.S.86-2000.(or latest) (for Telecom. Application) suitable for Axle counter application. To be procured from RDSO approved firms Inspection by consignee

8

29886

239088

... More
"Supply of Stationary low maintenence secondary lead acid cells 120 AH as per RDSO specification IRS S 88 2004 with topping up frequency upto 6 months This includes supply of intercell connectors bolts nuts, acid level indicating floats and vent plugs. Inspection by consignee

104

3080

320320

... More
Supply of PVC insulated wire copper conductor 16 0.2mm to ATC IS:694 to RDSO specification no.IRS:S 76 89 as per amendment 2 or latest Each coil of 100 mts length.To be procured from RDSO approved firms COIL=NO Inspection by RDSO

160

797

127520

... More
"Supply of PVC insulated wire, multi strand flexible copper conductor, 28 0.3 mm. to RDSO specification IRS.S.76 89 with amendment 2 or latest.Each coil of 100 mtrs length and to be procured from RDSO approved firms.INSPECTION BY RDSO COIL=NOS. Inspection by RDSO

32

1635

52320

... More
"Supply of PVC insulated wire multi-strand copper conductor 10 Sq.mm flexible Specn.IRS.S76/89.Amendment No.2 or latest. Each coil of 100 mts length. To be procured from RDSO approved firms (size 140/0.3mm)(Red- 50%,Black-50%) INSPECTION BY CONSIGNEE COIL=NOS

16

9390

150240

... More
Supply of Non-deteriorating type of fuse holders 20 Amps Capacity - electric fuse for Railway signalling.Rated voltage 240 AC DC to Specn. No. IRS S.78- 2006 IS 13703 (part 2 sec2) 1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip/Knife edge type size E1(R-SS) INSPECTION BY RDSO

160

150

24000

... More
Supply of Non-deteriorating type of fuse links 10 Amps Capacity electric fuse for Railway signalling.Rated voltage 240 AC DC to Specn. No. IRS S.78-2006 IS 13703 (part 2 sec2):1993 suitable for E1 fuse 20Amps SC 20 Holder SafeClip INSPECTION BY RDSO

160

21

3360

... More
"Supply of Non-deteriorating type of fuse links 2 Amps Capacity electric fuse for Railway signalling.Rated voltage 240 AC/DC to Specn. No. IRS S.78-2006 IS 13703 (part 2 sec2) 1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip INSPECTION BY RDSO

160

20

3200

... More
"Supply of terminal block 6 way PBT 25mm as per RDSO Drg.No. SA.23756/Alt.3 & IRS S.75/91 & IRS.S.23 with amendment no.2 or latest. INSPECTION BY RDSO"

200

285

57000

... More
"Supply of terminal block 1 way PBT 60mm as per RDSO Drg.No. SA.23745/Alt.5 & IRS S.75/91 & IRS.S.23 with latest amendment.INSPECTION BY RDSO"

200

61

12200

... More
"Supply of hylam sheet, resin bonded, 6mm thick ,grade P3, to IS specification IS: 2036 of 1974 or latest and size 2400mm X 600mm of colour approved by the site in-charge.INSPECTION BY CONSIGNEE"

8

2356

18848

... More
"Digging of cable trench to a depth of not less than 30 Cms in rocky terrain, Concreting the trench with 150mm thick concrete with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size. All the material is to be arranged by contractor"

400

128

51200

... More
Laying different type cables in the trench. Termination covered elsewhere.

4000

5

20000

... More
"Supply & laying of DWC split pipe of 120/103 mm dia, 2meter long in already dug cable trenches has per Drawing No.SK.9/11 .The unit of RMT means two split pipes of 1 Mtr each."

1200

232

278400

... More
"Breaking of metal/ tar road and refilling after laying the cables as per drawing no.SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface"

4000

142

568000

... More
Track crossing by horizontal boring method based on the drawing no.DRM/J/6735 dated 7-8-03 07 (enclosed) and as advised by the engineer at site. This includes the supply and insertion(pushing) of GI pipe (80mm) confirming to IS.1239 heavy class in the bore drilled with the coupler between two pipes. All the joints of casing pipes should be tight and leak proof.

200

1403

280600

... More
Supply Transportation and installation RCC cable Route Markers with round collers. They should be standard Lettering SCR S&T with SIGNALLING on the top engraved to a depth of 8 mm and painted on one side .They shall be painted with "Green" when placed at joint chamber, Yellow Placed at loop

40

272

10880

... More
Supply and Laying of GI pipes of 100mm dia medium quality to specification IS 1239 (part-I) 1990 09 and galvanised to specification IS.4736-1986 with coupling wherever required as per Rly. Requirement over the Cement bridges, girder bridges and drainage etc. In case of Cement Concrete bridges GI pipes are to be provided with brick masonary of 300x300x300mm at an interval of 2 M and the remaining portion

160

341

54560

... More
Supply and Laying of GI pipes of 50 mm dia medium quality to specification IS.1239 (part-I) 1990 10 and galvanised to specification IS.4736-1986 with coupling wherever required as per Rly. Requirement over the Cement bridges, girder bridges and drainage etc. In case of Cement Concrete bridges GI pipes are to be provided with brick masonary of 300x300x300mm at an interval of 2 M and the remaining portion INSPECTION BY CONSIGNEE

160

254

40640

... More
Supply and Laying of Double Walled Corugated Pipe(DWC) of REX or similar make of 120mm 11 outer dia/103 mm inner dia to IS spec.no.14930-part-II for underground cables of SIX meters length with one snap fit coupler Note -Contractor should submit the manufecturer internal test report,guarantee certificate,genuinness certificate for IS Brand.per length of six mtrs

80

1134

90720

... More
Foundations, erection, fixing of ' E' type locks, painting the box and painting of termination & other 12 particulars of Full GKP boxes . Metal Size of the aggregate should not be more than 40mm. Work to be done as per prescribed drawing no.SK/CN/1/89-A & B- All the material is to be arranged by the contractor except E- type lock ( E-type lock will be supplied by Rlys)

32

2460

78720

... More
Cable termination including fixing of ARA terminals, fuses, LDs etc, Meggering the cables and 13 recording the readings as per detailed technical specification. (All materials for the work except cable, ARA terminal, fuses and LD's shall be supplied by the contractor). Note: Payments can be made based on the meggering records submitted.per cond=nos

16000

7

112000

... More
Numbering of location box as per standard practice and writing all Cable(main and tail ) termination particulars and equipments inside the location box as per the details.LB serial number on four sides of the box connected earth pit perticulars and implantation to the track

32

280

8960

... More
Fixing relay bases on the relay frames erected in Relay Room, Wiring of all types of relays by drawing various sizes of wires/multicore cable, fixing fuses, condensers, resistances, LEDs etc and wiring duly soldering the same as per approved circuit diagram, testing point to point before soldering and after

240

174

41760

... More
Excavation of Earth Pit and providing earth pipe of size 50mm dia, 3.5mm thick 2.0 m. long G.I. 17 pipe with anti pulling out arrengement at the bottom and wound with 8SWG GI wire To be drawn from bottom of earth Pipe to top terminal point. with masonary tub constructed around at earthing locations as specified by site Engineer. Alternate layers of 30kgs-chrcoal and 30kgs common salt to be filled in the INSPECTION BY CONSIGNEE

48

1406

67488

... More
Supply and fixing of teak wood reapers with 50 mm width x 20mm thick and length of 940mm applying two coats of wood primer after Smooth finishing and varnishing Etc are suitable for Full location Box INSPECTION BY CONSIGNEE

160

130

20800

... More
Supply and fixing of teak wood reapers of size 50mm x 50mm x940mm in Full Box applying two coats of wood primer after Smooth finishing and varnishing Etc and clamping the Cables.NSPECTION BY CONSIGNEE PER REAPER=NOS

64

204

13056

... More
Supply and fixing of teak wood reapers with 75mm width x 20mm thick and length of 940mm applying two coats of wood primer after Smooth finishing and varnishing Etc is suitable for Full Box NSPECTION BY CONSIGNEE PER REAPER=NOS

64

159

10176

... More
Supply and fixing of 20mm thick teak wood planks of size is 940mmx20mm x300mm for Keeping Equipment in the Full Box after applying two coats of wood primer.NSPECTION BY CONSIGNEE PER PLANK=NOS

16

490

7840

... More
Supply and fixing of H.Wood planks of 40mm thick and not less than 200 mm width and required length with smooth surface, painting with black enamel (Hardwood paints & fixing bolts are to be arranged by contractor) NSPECTION BY CONSIGNEE

1.6

18673

29876.8

... More
Strengthening of signal full GKP Half GKP location box foundations by carrying out the earth work 23 around the signal/box raming of the earth carrying out masonry work from bottom of earth. work using country stones and cement mud masonary to prevent the earth from sliping down the bank.( All the materials required for the above work shall be arranged by the contractor)

32

2813

90016

... More
Fixing of the following on pre-erected relay racks. "I) Fixing of approximately 200 nos of 6 way/ 1 24 way terminal block horizontally on 6mm Hylam sheets which in turn to be fixed to rack with all supports as per instructions of SSE incharge. Materials such as bolts, nuts and supporting flats to be supplied by the contractor only."

8

479

3832

... More
"II) Cutting and fixing of Hylam sheet of 6 mm/3mm thickness to suit to 1 way relay rack and fixing the following with contractors screws, bolts and nuts and fixing strips, condensers and resistances of various values - 50 No. LS=NOS

8

103

824

... More
"III) Fixing of non-deteriorating fuse holders with LED indications and resistors and negative terminal strips on 6mm Hylam sheet with contractors screws, bolts and nuts."

160

5

800

... More
"Excavation of square coil pit up to a depth of 1 Mtr. X 1.5 Mtr. For providing coil at location box, point, signals etc., This includes back filling and ramming of trench / pit after laying the cable and consolidation of soil."

48

181

8688

... More
"Initial Charging of Secondary Cells 2 volts 80 AH Capacity.The required Acid and distilled water to be arranged by the contractor. Note:-Acid and Distled water Quality should be certified by the railways before mixing for solution.

104

220

22880

... More
"Preparation of Contact Analysis for 'Q' style relays as per detailed technical specification."

200

14

2800

... More
Fabrication and supply of MS frames to suit Q series relays to accommodate 6 No. in each set as per Drg.No. B.SG.CN. MISC.9.98 duly drilling required holes for relay bases (All materials such as frames bolts nuts and washers to be supplied by the contractor) (Only Relay bases will be supplied by the Railways)

32

294

9408

... More
(a) Stage -1 : testing of wires drawn point to point using buzzer. (one time Before soldering and two times after soldering .) PER SHEET =NOS

40

316

12640

... More
"(a) Circuit diagrams issued by the Railways ( of A-2 size ) are to be taken on reproduction tracing film and manually entering the relay contact number and other required circuit details if any. ( Reproduction tracing film and other consumables are to be arranged by the contractor.) PER SHEET OF A-2 SIZE=NOS

100

226

22600

... More
(b) Preparation of A-3 size drawings as at site. Providing one print on tracing paper on in stadard format. Drawings are to be prepared on polyester tracing film of double side 50 microns thickness. ( Polyester tracing film and other consumables are to be arranged by the contractor.) PER SHEET OF A-3 SIZE=NOS

100

99

9900

... More
"(c) Preparation of A-4 size drawings as at site. Providing one print on tracing paper on in stadard format. Drawings are to be prepared on polyester tracing film of double side 50 microns thickness.( Polyester tracing film and other consumables are to be arranged by the contractor.) PER SHEET OF A-4 SIZE=NOS

100

73

7300

... More
(d) Taking copies of approved circuit diagrams/drawings issued by the Railways on ammonia printing paper. (A-2 size.) - including supply of ammonia paper. EACH SHEET OF A-2 SIZE=NOS

100

7

700

... More
(e) Taking copies of approved circuit diagrams/drawings issued by the Railways on ammonia printing paper. (A-3 size.) - including supply of ammonia paper.EACH SHEET OF A-3 SIZE=NOS

100

4

400

... More
(f) Taking copies of approved circuit diagrams/drawings issued by the Railways on ammonia printing paper. (A-4 size.) - including supply of ammonia paper. EACH SHEET OF A-4 SIZE=NOS

100

4

400

... More
(g) Arranging rexin cloth bound booklets and binding for large size drawings EACH BOOKLET=NOS

48

174

8352

... More
(h) Arranging rexin cloth bound booklets and binding for small size drawings EACH BOOKLET=NOS

48

142

6816

... More
Transparent plastic cover superior quality for keeping circuit diagram sheets with provision for hanging size "C". INSPECTION BY CONSIGNEE

1000

40

40000

... More
"Transportation of materials from any Stores to Site and vice-versa including vLead above 50 Kms loading and unloading." PTPK=NOS

16000

4

76800

... More
"Supply and fixing of yellow retroreflective strips of 1"" width each on both sides of the yellow painted portion for both the lifting barrier booms. INSPECTION BY CONSIGNEE"

240

446

107040

... More
Fixing and wiring RKT/EKT for siding or L.C. Gate interlocking as per Tech./Specn. No. 15.12. This includes installation of Magneto telephones at location, gate, SM's office etc.,

8

602

4816

... More
"Foundation & Erection of Electrically operated lifitng barriers assembly, drive mechanism, motors etc. as per technical specification enclosed as annexure -B, with control panel, boom locking arrangements & 44 crank handles complete with Hand generator as per detailed technical specification and instructions of site in- charge.(The above work includes excavation of fit and concreting foundation for pedestal-2 nos :Excavation of pit and concreting foundation for meeting post-2 nos: Erection of Electrical Lifting barrier- 1 Set: Fixing of EOLB Panel and its wiring-1 No.as per detailed technical specification and instructions of site incharge." LS=NOS

8

16810

134480

... More
Testing and commissioning of Electric lifting barrier operation from panel. LS=NOS

8

5000

40000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.