Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Eprocure

Opening Date

22 Jun 2020

Closing Date

Cancelled

Tender Amount

₹ 11,42,00,000 
Notes
Download

Costs

  • EMD

    ₹ 8,96,000
  • Document Cost

    ₹ 3,000
  • Tender Fee

    ₹ 3,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹52,400/MT*
Maharashtra
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Schedule-A' Part-III A 'Internal Water Supply'

-

-

-

... More
Supply and fix Bib tap, fancy type, chromium plated Brass, of continental series of make Jaquar cat no 037 including all necessary fittings, screwed both ends for iron pipe of size 15mm dia. Complete all as specified & as directed.

2

-

-

... More
Supply and fix Pillar tap, fancy type, chromium plated Brass, of fusion series of make Jaquar cat no 23059 including all necessary fittings, screwed both ends for iron pipe of size 15mm dia. Complete all as specified & as directed.

4

-

-

... More
Supply and fix Pillar tap, fancy type, chromium plated Brass, of fusion series of make Jaquar cat no 23059 including all necessary fittings, screwed both ends for iron pipe of size 15mm dia. Complete all as specified & as directed.

2

-

-

... More
Supply and fix liquid Soap dispenser, chromium plated Brass, with glass bottle of continental series of make Jaquar cat no 1135M including all necessary fittings complete all as specified & as directed.

2

-

-

... More
Supply and fix Towel ring chromium plated Brass, of continental series of make Jaquar cat no 1151 including all necessary fittings, Complete all as specified & as directed.

2

-

-

... More
Schedule-A' Part-IV-A 'Internal Electrification ' Total of Schedule-'A' Part-IV-A B/F from serial page No. 31

1

-

-

... More
Schedule-A' Part-IV B 'Internal Electrification'

-

-

-

... More
M&L for CFL light fitting 2 x 36 Watts, surface mounting, low glare, white powder coated CRCA sheet steel housing with square paralite P-5 louver block, crescent light opening in a perforated metallic frame including CFL lamps all pre-wired and connecting up with three core twisted fleuiable cord of size 0.5 Sqmm from ceiling rose to CFL light fitting all as specified and as directed complete. Make : Bajaj cat No BSMLA 01236 CFL WEB 2, 530718 or Equivalent in CG/Philips.

10

-

-

... More
SS&F Aviation obstruction light yellow painted die cast aluminium housing, built in 75 VA stepup tranformer, heat resistant, clear thick glass complete with & including NEON lamp 75 VA, all fixing accessries & electrical connections. Make Bajaj Cat No BJAOL 020075 Or Eqivalent Model of Wipro/CG/Philips.

1

-

-

... More
S&F Garden area light fittings 25 watts, aerodynamically designed post top with conical housing and top cover of UV stabilized polythelene in grey complete with & including CFL bulb, mounting arrangement, fixtures and fittings, electrical connections. Make Cromption Greave Cat No AGNI-CFBA 25 WCFLDG Or Eqivalent Model of Bajaj/Wipro/Philips.

26

-

-

... More
S&F Metal halide light fitting 400 watts, black powder coated, diecast aluminium, built in control gear comprising of ballast, ignitor, capacitor etc. aluminium reflector, heat resistant toughned clear glass cover complete with & including T shaped 400 watts MH bulb, mounting arrangement over the roof projected towards the open area for illumination of open ground space, electrical connections.Make Bajaj Cat No BJFL 400 MHHTS Or Eqivalent Model of Wipro/CG/Philips.

4

-

-

... More
S&F Bulk head light fitting 1x18 watts, with ABS housing, clear polycarbonate cover with & including electronic ballast, 18 watts S type CFL lamp, connector block fixtures and fittings,internally pre-wired and including connecting up with twin core twisted flexible copper coductor cable with suitable size. Make Bajaj Cat No BJCB 118 WEB 531327 OR Eqivalent Model of CG/Philips/Wipro.

33

-

-

... More
S&F Batten holder, angle type, bekalite body with brass pins, ISI marked with & including 18 watts CFL lamp, electrical connections. Make Cromption Greaves/ Philips/Bajaj.

305

-

-

... More
S&F integral, flame proof well glass, CFL light fitting 2x18 watts epoxy finish, LM6 aluminium alloy housing with heat resistant toughned glass cover, built in control gear, painted MS wire guard & eye bolt complete with & including 2 nos 18 watts CFL bulb, hanging arrangement in FOL store, electrical connections.Make Cromption Greaves Cat No FWL 200/218 IH/A Or Eqivalent Model of Bajaj/Wipro/Sudhir.

1

-

-

... More
S&F Exhaust fan, flame proof of size 300mm sweep, complete with metalic body and louvers including internally pre-wired and including connecting up with thtee core twisted flexible copper wire of size 23/0076 from ceiling rose to exhaust fan drawn into metalic conduit. Make Sudhir/Cromption Greaves/Bajaj.

1

-

-

... More
S&F MCB, SP, 2 to 20 Amps, 50 Hz, 240Volts, 'C' series, 10 KA.

600

-

-

... More
S&F MCB, SPN, 6 to 32 Amps, 50 Hz, 240Volts, 'C' series, 10 KA.

111

-

-

... More
M&L for domestic Telephone and TV cable point wiring complete in and including concealed PVC conduit , medium grade of size not less than 25mm with all accessories fixed on wall /ceiling/ floor /roof etc, with PVC terminal box for mounting fittings viz telephone/TV socket including telephone wire 2 core, 1.5 sqmm & TV cable wire ISI marked.lete all as specified & as directed.

101

-

-

... More
S&F Telephone socket, ISI marked complete all as specified and directed. Make: Anchor Roma Cat no 20857 or equivalent make Leader.

58

-

-

... More
S&F Cable TV socket, ISI marked complete all as specified and directed. Make: Anchor Roma Cat no 21157 or equivalent make Leader.

58

-

-

... More
S&F Composite metal DB panel for telephone / internet cabling for each floor having capacity of 12 pairs.

10

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanised earth strip 32x6 mm by means of bolts, nuts, and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I connected to main DB including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe, medium grade 50mm bore for earth lead and 20mm bore for watering, excavation and earthwork in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate including testing on completion.Note: GI earth strip 32x6 mm beyound 7.5m will be measured & paid for seperately.

11

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, LT cubical panel board of standard size, dust and vermin proof, fabricated out of 2.0mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 200 Amps rated electrolysis copper bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted over the hygroscopic insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3 phase 4wire system complete including accommodating, supplying and fixing the following accessories:

6

-

-

... More
(a) MCCB 63 Amps, 4 pole, 415V, 25 kA, 'C' series with microprocessor release & adjustable overload 70 to 100% - 01No(Incoming).(b) MCB SPN 32Amps, 240V, 50 Hz, 10 kA, 'C' series- 08 Nos.(c) Indicator lamp LED type (set of three RYB) - 01set.(d) Digital Voltmeter 0 to 500 volts with selector switch -01 No .(e) Digital Ampere meter 0 to 100 amps with CTs & selector switch -01 No .(f) Fixing only electronic energy meter , temper froof, single phase 230 volts with LCD display accuracy class I, 10 TO 20 AMPS-06 nos. Note : Energy meters will be issued under 'Sch B' free for fixing only.Panel to be installed at each floor of 1st to 6 th floor in the shaft & incoming shall be connected from main panel installed at meter/utility room at GF & outgoing shall go upto each MCBDB through submain wiring.

-

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, LT cubical panel board of standard size, dust and vermin proof, fabricated out of 2.0mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 200 Amps rated electrolysis copper bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted over hygroscopic insolates insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3phase 4wire system complete including accommodating, supplying and fixing the following accessories(for 7th & 8th floor):

3

-

-

... More
(a) MCCB 63 Amps, 4 pole, 415V, 16 kA, 'C' series with microprocessor release & adjustable overload 70 to 100% - 01No(Incoming).(b) MCB SPN 32Amps, 240V, 50 Hz, 10 kA, 'C' series- 02 Nos.(c) MCB SPN 20 Amps, 240V, 50 Hz, 10 kA, 'C' series- 01 No.(d) Indicator lamp LED type (set of three RYB) - 01set.(e) Digital Voltmeter 0 to 500 volts with selector switch -01 No .(f) Digital Ampere meter 0 to 63 amps with CTs & selector switch -01 No .(g) Fixing only electronic energy meter , temper froof, single phase 230 volts with LCD display accuracy class I, 10 TO 20 AMPS-2 nos. Note : Energy meters will be issued under 'Sch B' free for fixing only.

-

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, LT cubical panel board of standard size, dust and vermin proof, fabricated out of 2.0mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 200 Amps rated electrolysis copper bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted over hygroscopic insolates insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3 phase 4wire system complete including accommodating, supplying and fixing the following accessories(for Servants quarter):

2

-

-

... More
(a) MCCB 63 Amps, 4 pole, 415V, 25 kA, 'C' series with microprocessor release & adjustable overload 70 to 100% - 01No(Incoming).(b) MCB SPN 20 Amps, 240V, 50 Hz, 10 kA, 'C' series- 08 Nos.(c) Indicator lamp LED type (set of three RYB) - 01set.(d) Digital Voltmeter 0 to 500 volts with selector switch -01 No. (e) Digital Ampere meter 0 to 100 amps with CTs & selector switch -01 No. (f) Fixing only electronic energy meter , temper froof, single phase 230 volts with LCD display accuracy class I, 10 TO 20 AMPS-03 nos. Note : Energy meters will be issued under 'Sch B' free for fixing only.

-

-

-

... More
Schedule-A' Part-V 'Area Drainage ' Total of Schedule-'A' Part-V. B/F from serial page No. 33

1

-

-

... More
Schedule-A' Part-VI-A 'Sewage Disposal' Total of Schedule-'A' Part-VI (A) . B/F from serial page No. 36

1

-

-

... More
Schedule-A' Part-VI-B 'Sewage Disposal'

-

-

-

... More
M&L Construction of Brick masonry Septic tank 150 users including exacavation/ earthwork, PCC foundation, Brickwork in CM (1:4),15mm thick plaster in CM (1:4), Precast manhole cover having 6mm plate embedded allround with angle iron frame,vent shaft,Inlet/Outlet pipe and jointing complete all as shown on drawings no TD/2007/10 SHEET 1/4 TO 4/4 DATED 10 Apr 2007. and as specified.

1

-

-

... More
M&L Construction of brick masonry soak pit suitable for 150 users capacity including exacavation/earthwork, PCC foundation, Brickwork in CM (1:4), Filteration material consisting of hardcore stone, Burnt bricks pieces etc complete all as shown on drawings no. WD/2008/03 Sheet 38/38. and as specified.

1

-

-

... More
Schedule-A' Part-VII 'Road/Path /Hard standing ' Total of Schedule-'A' Part-VII B/F from serial page No. 38

1

-

-

... More
Schedule-A' Part-VIII-A 'External Water Supply' Total of Schedule-'A' Part-VIII(A) B/F from serial page No. 40

1

-

-

... More
Schedule-A' Part-VIII-B 'External Water Supply'

-

-

-

... More
S & F CI sluice valve with flanged ends, cast iron body flanged and drilled end non rising type , brass spindle with nuts, class PN-1.6 suitable for 80 mm bore as per IS:14846, ISI marked including all joints with rubber or fibre board, bolts and nuts ,washers etc complete all as specified and as directed.

2

-

-

... More
S & F CI sluice valve with flanged ends, cast iron body flanged and drilled end non rising type , brass spindle with nuts, class PN-1.6 suitable for 100 mm bore as per IS:14846, ISI marked including all joints with rubber or fibre board, bolts and nuts ,washers etc complete all as specified and as directed.

1

-

-

... More
S & F CI Non Return valve, 80mm dia. with ISI marked conforming to IS 5312 including double flanges by providing necessary pair of M.S. flanges with nuts, bolts, including all joints with rubber or fibre board, bolts and nuts ,washers etc complete all as specified and as directed.

3

-

-

... More
Supplying, Installing, perfect aligning and proper levelling,commissioning and Testing of Centrifugal pump, horizontal end suction close coupled back pull out type of 450 LPM at not less than 40 mtr head C.I casing single stage with Bronze impeller and dynamically balanced , Bronze working parts (EN-8) shaft running in double ball bearing, coupled to suitable AC 3 phase TEFC motor, in IP-55 enclosure of suitable HP 1450 RPM, 415 volts, 50 cycles & motor are to be mounted on common base plate as specified by OEM along with suitable rigid foundation, nut bolts, with coupling guards & antivibration rubber pads in an approved manner in and including suction pipe of suitable size and length connection and DOL startor and MCB TPN 20A, Class `C' on suitable size of wooden board complete all as specified and as directed.

2

-

-

... More
Supply, install, testing & commisioning pressure feed type Chloronome plant comprising of one number PVC tank of 100 litre capacity with lid & agitator assembly (consisting of one single phase electric motor, long shaft, PVC blades etc) for mixing granuals with water to make homogeneous solution, one number feeding pump consisting of single phase motor connected with suitable capacity of pump for injecting the homogeneous soloution of granuals into water supply line complete in all respect complete all as specified and as directed. Make: Altoch dozing pump/Ion exchange dosing pump.

1

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, LT cubical panel board of standard size, IP-52 free standing, floor mounted, dust and vermin proof, fabricated out of 2.0mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 200 Amps rated bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted on hygroscopic insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3phase 4wire system complete including accommodating, supplying and fixing the following accessories:

1

-

-

... More
(a) MCCB 100 Amps, 4 pole, 415V, 25 kA, 'C' series - 01No(Incoming).(b) MCCB 40 Amps, 3 pole, 415V, 10 kA, 'C' series - 02Nos (Outgoing) Pumps.(c) MCB SPN 20Amps, 240V, 50 Hz, 10 kA, 'C' series- 02 Nos (Outgoing).(d) Indicator lamp LED type with 3 nos of 2A HRC fuses (set of three RYB) - 04 sets.(e) Digital Voltmeter 0 to 500 volts with selector switch -01 No Make: PAMEBRITA-31 HPL or equivalent .(f) Digital Ampere meter 0 to 100 amps with CTs & selector switch -01 No Make: PAMEBRITA-31 HPL or equivalent .(g) Fully automatic star delta starter upto 20 HP-02 nos.(h) Onload change over switch, 100 amps, HP, 415 volts-01 no.(i) Internal wiring with suitable size of PVC insulated multistranded copper conductor cable duly crimped with copper lugs & ferruled.

-

-

-

... More
Construction of brick masonary valve chamber of internal dimension 90 x 90 x 90 cm with brick works masonary over foundation in PCC ( 1:4:8) type D 2 , and coping with 50 mm thick PCC (1:2:4) type B1, and plastering 15 mm thick with cm (1:4) up to 75 cm below normal ground level including hinged MS cover made out from 40x40x6 mm thick ms angle frame& ms sheet 3 mm thick with lifting handle & locking arrangement complete with two coats of bituminius paint over a coat of red primer and frame cocealed in PCC foundation including necessary excavation & earth work in any type of soil , removing surplus soil to a distance not exc. 50 mtr , complete all as shown in drawing and as directed by Engineering-in-charge .

4

-

-

... More
Schedule-A' Part-IX-A 'External Electrification' Total of Schedule-'A' Part-IX(A) B/F from serial page No. 43

1

-

-

... More
Schedule-A' Part-IX-B 'External Electrification

-

-

-

... More
Supply and fix street light luminaires HPMH 150 watts, single piece, die cast/deep drawn aluminium housing complete with & including control gear compartment, acrylic cover UV stabilized ballast of dual tapping dynamic power starting device to reduce power and wattage including 150 Watt MH lamp and other accessories and mounting on bracket made out of 40mm bore medium grade GI pipe 1.5m long,bent to required shape and fixing accessories such as clamps,nuts & bolts. Make:

9

-

-

... More
M&L looping box made out of 2.0 mm CRCA sheet phospharised powder coated of size 225mm x 175mm x 100mm of hinged cover weather proof with and including locking arrangement, shutter to be opened & closed vertically with retained ball locking system, TPN aluminium bus bar & strip 16 amps capacity and 6 Amps MCB SP 10 KA-1 No and fixed to pole by means of GI clamps, bolts, nuts and washers with connector complete all as specified and as directed.

9

-

-

... More
S&F Air load break switch, indoor type, 11 KV, 630 amps, 25 KA consisting of one nunber incomer without fuses & one number load break switch as outgoing with HRC fuses, fuse trip mechanisum, earth switch, aluminium bus bar, set of HRC fuses of 5 amps complete all as specified and as directed.

2

-

-

... More
Supply and install, testing and commissioning Transformer, indoor type, 11 KV/415volts, 200 KVA , dry cast resin with double wound copper winding, AN, DYN-11, insulation class H, off line tep changer, + 5% in steps of 2.5% on HV side, cable end box on HT & LT side, winding temperature, indicator and all standard accessories as per manufacturers instructions including making rigid platform of requried size to keep the transformer at least 15 cm above ground, laying, connecting LT/HT cable, carrying out complete earthing connections, testing complete all as specified and as directed. Make: Kirloskar/Cromption/ABB/Areva. Note:- “(a) Contractor has to submit the detail specifications, drgs, manufacturers test report for the approval of GE. (b) The iron loss test, cu-loss test, high voltage test shall be carried out at factory premises & report shall be submitted for the approval of GE and all these arrangement shall be made by the contractor.”

1

-

-

... More
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to 32 x 6mm GI strip as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 40 mm dia GI pipe light grade for protection of wire etc including necessary excavation and eartwork in any type of strata , filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I. Note: GI earth strip 32x6 mm beyound 7.5m will be measured & paid for seperately.

12

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, cubical panel board of standard size, IP-52 free standing, floor mounted, dust and vermin proof, fabricated out of 3.15mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 400 Amps rated bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted on hygroscopic insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3 phase, 4wire, 415 volts, 50 HZ, AC supply system complete including accommodating, supplying and fixing the following accessories:

1

-

-

... More
(a) MCCB 300 Amps, 4 pole, 415V, ICU 36 kA, 'C' series with microprocessor release & suitable oner load 70% to 100% - 01No(Incoming).(b) MCCB 200 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 01No.(c) MCCB 100 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 04Nos.(d) Indicator lamp LED type with 3 nos (set of three RYB) - 01 set.(e) Digital Voltmeter 0 to 500 volts with selector switch -01 No .(f) Digital Ampere meter 0 to 300 amps with CTs & selector switch -01 No .(g) Internal wiring with suitable size of PVC insulated multistranded copper conductor cable duly crimped with copper lugs & ferruled.

-

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, cubical panel board of standard size, IP-52 free standing, floor mounted, dust and vermin proof, fabricated out of 3.15mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 200 Amps rated bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted on hygroscopic insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3 phase, 4wire, 415 volts, 50 HZ, AC supply system complete including accommodating, supplying and fixing the following accessories:

1

-

-

... More
(a) MCCB 100 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 01No(Incoming).(b) MCCB 63 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnatic release & suitable oner load 20% to 100% - 01No.(c) MCCB 40 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 02Nos.(d) MCCB 16 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 02Nos.(d) MCCB 16 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 02Nos.(d) Indicator lamp LED type with 3 nos (set of three RYB) - 01 set.(e) Digital Voltmeter 0 to 500 volts with selector switch -01 No .(f) Digital Ampere meter 0 to 100 amps with CTs & selector switch -01 No .(g) Internal wiring with suitable size of PVC insulated multistranded copper conductor cable duly crimped with copper lugs & ferruled.

-

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, cubical panel board of standard size, IP-52 free standing, floor mounted, dust and vermin proof, fabricated out of 3.15mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 300 Amps rated bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted on hygroscopic insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3 phase, 4wire, 415 volts, 50 HZ, AC supply system complete including accommodating, supplying and fixing the following accessories:

1

-

-

... More
(a) MCCB 200 Amps, 4 pole, 415V, ICU 36 kA, 'C' series with microprocessor release & suitable oner load 70% to 100% - 01No(Incoming).(b) MCCB 63 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 20% to 100% - 10 Nos.(c) Indicator lamp LED type with 3 nos (set of three RYB) - 10 sets.(d) Digital Voltmeter 0 to 500 volts with selector switch -01 No .(e) Digital Ampere meter 0 to 200 amps with CTs & selector switch -01 No .(f) Internal wiring with suitable size of PVC insulated multistranded copper conductor cable duly crimped with copper lugs & ferruled.

-

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, cubical panel board of standard size, IP-52 free standing, floor mounted, dust and vermin proof, fabricated out of 3.15mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 200 Amps rated bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted on hygroscopic insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3 phase, 4wire, 415 volts, 50 HZ, AC supply system complete including accommodating, supplying and fixing the following accessories:

1

-

-

... More
(a) MCCB 100 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 01No(Incoming)(b) MCCB 40 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 04 Nos.(c) Indicator lamp LED type with 3 nos (set of three RYB) - 01 set.(d) Digital Voltmeter 0 to 500 volts with selector switch -01 No .(e) Digital Ampere meter 0 to 200 amps with CTs & selector switch -01 No .(f) Internal wiring with suitable size of PVC insulated multistranded copper conductor cable duly crimped with copper lugs & ferruled.

-

-

-

... More
Supplying, installing, testing and commissioning of factory fabricated, CPRI approved, Indoor type, cubical panel board of standard size, IP-52 free standing, floor mounted, dust and vermin proof, fabricated out of 3.15mm thick CRCA sheet, weather proof, ventilated with inbuilt industrial type locking arrangement duly epoxy powder coated Siemens grey colour mat finish and wall mounted including 100 Amps rated bus-bar for phase & neutral insulated with heat shrinkable sleeves RYB coloured mounted on hygroscopic insulators, prewired with PVC insulated copper conductor for monitor wiring, cable glands for all incoming / outgoing cables. The LT panel board shall be suitable for 3 phase, 4wire, 415 volts, 50 HZ, AC supply system complete including accommodating, supplying and fixing the following accessories:

1

-

-

... More
(a) MCCB 63 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnetic release & suitable oner load 70% to 100% - 01No(Incoming)(b) MCCB 40 Amps, 4 pole, 415V, ICU 16 kA, 'C' series with thermal magnatic release & suitable oner load 70% to 100% - 03Nos.(c) MCB TPN, 32 Amps, 10 kA, 415 volt, 'C' series - 02Nos.(d) MCB SPN 10 Amps, 415V, 'C' series- 01No.(e) Indicator lamp LED type with 3 nos (set of three RYB) - 01 set.(f) Digital Voltmeter 0 to 500 volts with selector switch -01 No .(g) Digital Ampere meter 0 to 100 amps with CTs & selector switch -01 No .(h) Internal wiring with suitable size of PVC insulated multistranded copper conductor cable duly crimped with copper lugs & ferruled.

-

-

-

... More
Schedule-A' Part-X 'Lightening Protection' Total of Schedule-'A' Part-X B/F from serial page No. 45

1

-

-

... More
Schedule-A' Part-XI 'Fire fighting'

-

-

-

... More
Supplying, Installing, perfect aligning and proper levelling,commissioning and Testing of Terrace pump of 900 LPM at 40 mtr. head having C.I casing single stage (mono block) with Bronze impeller, Bronze working parts (EN-8) tensile steel shaft (C-40) and directly coupled to suitable capacity motor, `B' class insulation TEFC squirrel cage induction motor working on 3 phase, 440 Volts,AC both pump & motor are to be mounted on common base plate along with suitable rigid foundation, nut bolts, with coupling guards & antivibration rubber pads in an approved manner in and including suction pipe of suitable size and length connection and DOL startor and MCB TPN 20A, Class `C' on suitable size of wooden board all as specified and as directed.Make: Kirloskar/KSB/Mather & platt).Note:(i) Out of above two pumps, one pump shall start & stop automatically with the help of pressure sensors to ensure adequate pressure in wet riser. (ii) Any accessories requried for smooth functioning of pumps shall deeemed to be included into quoted rate.

2

-

-

... More
Supplying, laying, and jointing 100mm dia heavy grade GI pipe(ERW), flanged, Class `C', conforming to IS : 1239 in trenches/wall/floor including all fittings, such as coupling, bends, elbow and tee etc, supported by GI hangers, anchor fastners, painting with 2 coats of enamel paint over a coat of zinc dichromate primer, making direction arrows, labelling etc complete all as specified & as directed.

50

-

-

... More
Supplying, laying and jointing 80mm dia heavy grade GI pipe(ERW), flanged, Class `C', conforming to IS : 1239 in trenches/wall/floor including all fittings, such as coupling, bends, elbow and tee etc, supported by GI hangers, anchor fastners, painting with 2 coats of enamel paint over a coat of zinc dichromate primer, making direction arrows, labelling etc complete all as specified & as directed.

15

-

-

... More
S & F fire hydrant GM double head outlet flanged inlet oblique type landing valve type A of 63 mm size confirming to IS-5290 with ISI mark, C.I hand wheel, plunger type female instantaneous brass coupling, including making flanged joints by providing necessary GI nuts, bolts, gaskets, with brass cap, GI chain etc. complete all as specified and as directed. Make: Newage/Shah Bhogilal)

10

-

-

... More
S&F first aid fire hose reel , drum type, wall mounted swinging type, swinging 180 degrees fitted with 30 mtr long ,20 mm dia ,high pressure dunlop hose conforming to IS: 5132 with 6.3 mm dia bronze shut off type jet nozzle, making connection to the vertical riser by cutting, welding, providing 20mm dia shut off valve, fixing the hose reel with necessary anchor fastners by drillling holes in walls/RCC making good the same complete all as specified and as directed. Make: Newage/Suprex)

10

-

-

... More
S&F 63 mm dia, 2 lenghts of 15 mtr long woven jacketed fire hose with external coat of synthetic fibre and EPDM rubber lining from inside having 42 kg/sqcm burst pressure, 18 kg/sqcm working pressure including brass male & female instantaneous coupling, short size gun metal branch pipe with 63mm instanteneous male inlet, hose confirming to IS:636 type II and coupling confirming to IS 903- 1975 as specified and as directed. Make: Nawage/Fire hydrant.

20

-

-

... More
S & F courtyard fire hydrant consisting of 63mm dia. Single outlet flanged hydrant valve with instantaneous female plunger type coupling, brass blank cap with GI chain including making flanged joints by providing necessary GI nuts, bolts, gaskets, with brass cap , GI chain etc. for 80mm dia stand post with provn of single outlet confirming to IS 908 complete all as specified & as directed.

2

-

-

... More
Supplying & installation of wall mounted 16 gauge thick MS cabinet of size 800x6000x350mm with structural mounting supports, mounted above the ground at minimum height of 1.0 m with glazed 5mm thick glass swing door (double/single) with locking arrangement & lock of 5 lever Godrej & duly marked 'FIRE HOSE BOX', painted with 2 coats of post office red paint over a coat of red oxide primmer and suitable to accommodate landing valve, hose reel and branch pipe etc complete all as specified and as directed.

10

-

-

... More
S & F ISI marked two way GM collector head fire brigade connection consisting of 63mm dia instanteneous type with inbuilt check valve conforming to IS-904 with glazed front metal enclosure complete all as specified and as directed.

1

-

-

... More
S&F standard short size gun metal branch pipe with gunmetal nozzle 63 mm nominal bore , outlet and strandard instantaneous coupling 63 mm dia, arrangement for straight stream spray shut off, trigger type handle complete all as specified & as directed.

20

-

-

... More
S&F 100mm dia CI Non return valve heavy duty conforming to Is-5312 with ISI marked including double flanges, by providing necessary pair of MS flange nuts, bolts, gasket etc including testing to 1.5 times working pressure complete all as specified & as directed. Make: Kirloskar /Audco

3

-

-

... More
S&F 80mm dia CI Non return valve heavy duty conforming to Is-5312 with ISI marked including double flanges, by providing necessary pair of MS flange nuts, bolts, gasket etc including testing to 1.5 times working pressure complete all as specified & as directed. Make: Kirloskar /Audco.

1

-

-

... More
S & F 100mm dia CI butter fly valve with double flanges, of pressure rating class PN-1.6 suitable for 100 mm bore as per IS:13095, ISI marked including all joints with rubber or fibre board, bolts and nuts ,washers etc complete all as specified and as directed. Make: Kirloskar /Audco/Intervalve.

4

-

-

... More
S & F 100mm dia CI butter fly valve with double flanges, of pressure rating class PN-1.6 suitable for 100 mm bore as per IS:13095, ISI marked including all joints with rubber or fibre board, bolts and nuts ,washers etc complete all as specified and as directed. Make: Kirloskar /Audco/Intervalve.

2

-

-

... More
S&F 100mm dia CI 'Y' Strainer with ISI marked including stainless steel/brass screen & clean with double flanges, alongwith necessary nuts, bolts, gasket etc including testing to 1.5 times working pressure complete all as specified & as directed. Make: Zoloto /Sant.

1

-

-

... More
S&F 80mm dia CI 'Y' Strainer with ISI marked including stainless steel/brass screen & clean with double flanges, alongwith necessary nuts, bolts, gasket etc including testing to 1.5 times working pressure complete all as specified & as directed. Make: Zoloto /Sant.

3

-

-

... More
S&F electric motor siren conforming to IS 1941 suitable for three phase 415 V supply with motor suitable for 4 HP and able to deliver 143 DB noise level continuousally atleast 50 minutes Siren will have an automatic equipment for producing a warning noise complete all as specified & as directed.

2

-

-

... More
S & F fire extinguisher dry chemical powder (ABC) type 5 Kg capacity. (IS : 2171/13849, 14609) complete all as specified & as directed. Make: Ceasefire/Safex.

10

-

-

... More
S & F fire extinguisher CO2 type 5 Kg capacity (IS:2878) complete all as specified and as directed. Make: Ceasefire/Safex.

10

-

-

... More
S & F fire extinguisher Mechanical foam (AFFF) type 9 litres capacity (IS:10204). complete all as specified and as directed. Make: Ceasefire/Safex..

10

-

-

... More
Supply, fix, install & commisioning of Addressable Dual Action Manual Pull Stations complete recessed (break glass unit) including providing 16 swg thick MS sheet box of suitable size including push button switch (MCP), concealing the in the wall and with mounting accessories complete all as specified and as directed.Make : GE Edwards Model SIGA-270 or Equivalent from Notifier/Seimens/System Sensor

10

-

-

... More
Supply, lay, testing & commissioning PVC insulated, ISI Marked 2 core x 1.50 sqmm, Multistrand Copper conductor, FRLS Armoured cable, for flow switches to annunciation panel with end termination in & including GI Pipe 15mm dia, class 'B' pipe with necessary GI saddle ,spacers, GI Junction Box, lugs, cable compression glands, cable tags and Ferrling etc complete all as specified and as directed.

200

-

-

... More
Supply, laying and testing LT XLPE insulated, armoured heavy duty electric cable with aluminum conductor, 1100 Volts grade of size 3.5 core 35 Sqmm laid in trenches/ducts/wall or through pipe on pole with suitable size cable glands,crimping type cable lugs complete all as specified and as directed.Note: Cable will be issued under Schedule B on Payment.

50

-

-

... More
S & F Electonic type fire alarm hooter, medium intensity complete all as specified & as directed.

10

-

-

... More
S & F Pressure gauge 100mm dia suitable to read upto 14 kg/sqcm pressure including connecting accesssories complete all as specified & as directed.

1

-

-

... More
S & F Pressure sencing switch , universal type suitable to set the desired and generating the signal for automatic start & stop to terrace /jocky pump including connecting accesssories complete all as specified & as directed.

1

-

-

... More
S&F detectors complying with and type certified to EN-45 addressable type smoke detectors photo electric/optical with base with self built intelligence as per IS 11360 complete all as specified and as directed.

20

-

-

... More
Supply and and installing, testing of air release valve, cast iron body with two air out lets confirming to IS 14845 of size 100 mm bore including all fixing accessories all as specified and directed

1

-

-

... More
Supply installing, testing and commissioning Terrace Jockey pump TAC approved perfect aligning and proper leveling having 180LPM discharge at 40 Mtr head, 2900RPM, Single stage with bronze impeller, bronze working parts (EN-8) (C-40) and directly coupled to suitable capacity HP Motor. `B` class insulation, squirrel cage induction motor working on 3 phase, 440 Volt AC, both pumps and motors are to be mounted on common base frame along with suitable rigid foundation, nuts,bolts,with coupling guards and antivibration rubber pads including required civil work for foundation, making electrical connection in and including required capacity of starter, connecting leads from starters to motors complate in all respect all as specified and directed.Note :- Terrace pump shall have the provision of start & stop automatically to maintain the desired pressure in fire fighting pipe lines.

1

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanised earth strip 32x6 mm by means of bolts, nuts, and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I connected to main DB including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe, medium grade 50mm bore for earth lead and 20mm bore for watering, excavation and earthwork in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate including testing on completion.Note: GI earth strip 32x6 mm beyound 7.5m will be measured & paid for seperately.

8

-

-

... More
S & F GI Strip 32x6mm buried in ground or fixed to wall with fixing accessaries from main test point to panel board of each floor complete all as specified and directed.

50

-

-

... More
S & F test cum bimetallic inspection joint made out of gun metal of size 75 x 75 x 25 mm drilled & screwed including 03 Nos 8mm dia 25mm long hexagonal head screws for holding the phosphorous bronze plate including fastening/bolting the for jointing down conductor of aluminium strip and GI earth strip and aluminium ends soldered and complete joint housed in FRP Box of size 15cmx15cmx10 mm below the test point & MS sheet 3.0mm thick box front operated including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.

2

-

-

... More
Supply, installing, testing and commissioning automatic plug in electronic type 4 zone fire alarm control panel housed in not less than 2mm thick CRCA sheet endosure duly painted with two coats of red post office synthetic enamel paint over a coat of red oxide primer incorporating modular design integrated solid state circuitry gold/silver plated finger PCB and operating on 220 volts AC/24 volt DC suitable for and fitted with the following accessories.

1

-

-

... More
(a) Public address system.(b) Fire and fault repeater.(c) Zone wise/communicatoin hooter.(d) Zone expand facility.(e) Smoke detecting system.(f) Control switch like zone wise ON/OFF, zone wise open, lamp test, alarm acknowledge, fault isolate, power ON/OFF, trickle/fast charging.(g) Suitable transformer cum rectifire to supply 24 volt DC from 230/220 volt AC single phase.(h) 2x12 volt, 60 AH, maintenance free battery of make exide

-

-

-

... More
Supply, fix, test & commission Sheet steel,IP 52, Totally enclosed, dust & vermin proof , free Standing , compartment , cubicle type indoor L.T panel board for operation on 440 volts, 3 phase , 4 wires, 50 c/s , A.C. system, factory made, CPRI approved, powder coated, fabricated not less than 2mm thick MS sheet having ventillation slots, locking arragements complete in all respect for operation of fire fighting pumps, with interlocking wiring controled with pressure sensers/water level gauge complete in all respect and comprising the following.

1

-

-

... More
a) 63 Amp 415V ,4 Pole, MCCB,25kA-1 No as an Incomerb) MCCB TP 32A ,10 KA - 02 No (O/G).c) Fully automatic Star Delta starter with relay range upto 20A - 02 No.d) Digital type Voltmeter class 1 cat no PAMEBRITV-31 with selector switch of Make: HPL or equivalent - 01 No.e) Digital type Ammeter class 1 cat no PAMEBRITA-31 with selector switch of Make: HPL or equivalent - 03 Nos.f) Internal wiring with inter locking system with jockey pump/terrace pump with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled.g) Copper busbar, with heat shrikable R.Y.B. and black sleevs, having 100 Amp capacity for phase & neutral - 01 Set.h) Relay to read the pressure of wet riser and give operating signal to pumps - 01 Set.j) Indicator R.Y. B LED type -03 Set

-

-

-

... More
Schedule-A' Part-XII 'COOLING/SUMMER APPLIANCES'

-

-

-

... More
Fixing, install, connecting up and testing Water Cooler having storage capacity of 80 litres and nominal cooling capacity of 40 litres partially stainless steel body, electric driven, single phase complete capacity of 40 litres per hour. NOTE: Water Cooler will be issued under Schedule B Free for Fixing only.

4

-

-

... More
Fixing, install connecting up and testing Storage water heater, vertical, electric having capacity of 25 litres with & including flexible pipe for hot and cold water, anchor fastner 4 nos of suitable size, 3 core PVC insulated copper conductor cable and plug top of 15 amps capacity. NOTE: Storage water heater will be issued under Schedule B Free for Fixing only.

52

-

-

... More
Fixing, install connecting up and testing Storage water heater, vertical, electric having capacity of 50 litres with & including flexible pipe for hot and cold water, anchor fastner 4 nos of suitable size, 3 core PVC insulated copper conductor cable and plug top of 15 amps capacity. NOTE: Storage water heater will be issued under Schedule B Free for Fixing only.

1

-

-

... More
Schedule-A' Part-XIII 'AIR CONDITIONING'

-

-

-

... More
Install, testing and commissioning of Split type air conditioner unit 1.5 ton capacity, indoor/outdoor, complete with cordless remote control system using green gas refrigent and with in built anti dust filter for better indoor air quality having memory function, dry mode, auto mode, on/off timer in remote with minimum 5 star rating complete all as specified and as directed.NOTE: Split ytpe AC will be issued under Schedule B Free for Fixing only.

8

-

-

... More
upply installed , testing commissioning copper pipe 3/8 complete with necessary insulation and nuts, bolts etc complete all as specified and as directed.

40

-

-

... More
Schedule-A' Part-XIV 'STAND BY DG SET '

-

-

-

... More
Supply, installing, testing and commissioning , factory assembled diesel engine driven generating set, fully wired alternator AC to give an output of 50 KVA/40KW continuously at a PF of 0.8 lagging, 415 volts AC 3 phase 4 wire 50 HZ +/- 5% supply, 1500 RM, directly coupled with diesel engine air cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacture's instructions, vibration damper pads, control panel & other accessories etc. and comprising of following:-

1

-

-

... More
(a) Diesel Engine, water cooled turbo charged of not less than 69 BHP capacity, fuel efficient to give an outlet equivalent to 50 KVA at 1500 RPM under NTP conditions of BS 5514/ISO 3046 and confirming to IS 10002, Din 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 continous hours operation with the following accessories:-Make- Cummins (I) Ltd Model No C 50 D5P or equivalent in Kirloskar Oil Engine Ltd (KOEL). Note: The contractor has to submit detailed specification, Model No., technical literature, drawing and other documents for approval of accepting officer.(i) Radiator with blower fan or heat exchanger with guard(ii) Pipe coupling for engine cooling system piping(iii) Corrosion inhibitor coolant filter(iv) fuel filter.(v) Lube oil filter.(vi) By pass filter.(vii) Fly wheel housing and fly wheel to suit alternator.(viii) Engine bearing mechanism in fly wheel housing.(ix) Shut off coil with safeties for LLOP/HWT, over speed.(x) dry type air cleaners and vacume indicators.(xi) Residential silencers.(xii) Stainless Steel exhaust flexible bellows.

-

-

-

... More
(xiii) Motor driven priming pump.(xiv) battery charging alternator.(xv) Exhaust piping made out of STIC C class MS pipe inclusive of all accessories and hardware, necessary support scaffolding as per manufacture's recommondations to sustain back pressure with rain cap.(xvi) Mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature claddedwith aluminium sheet of 30 guage for the entire length of exhaust pipe.(xvii) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(xviii) Inter connecting copper cabling of adequate capacity between batteries control.(xix) Fuel pipe C class STIC 1"/ 1.5' / 2" dia - 01 lot.(xx) Self starter 12 volts D.c.(xxi) Electric operated electronic governor.(xxii) Fuel injection pump.(xxiii) Electronic instrument panel, complete with all accessories as per manufacture's specifications displaying the following:-(a) Battery voltage.(b) Water temperature.(c ) Lubricating oil pressure.(d) Engine speed.(e) Engine hours.(f) Frequency.(g) Voltage.(h) Safety control (trip and indication).(J) High water temperature.(k) Low lube oil.(l) Over speed stop pressure.(xxiv) base frame: Strudy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacture's design alongwith AVM pads.

-

-

-

... More
(aa) Battery:- 1 No, 12 volt, 120 AH, maintenance free battery with leads and terminals. (Make of battery: Exide/Amron).(ab) Fuel tank: 08 hrs full load diesel storage capacity fuel tanks with mounting brackets factory made of not less than 3.0 mm thick HR/MS sheet with level indicator fuel inlet, fuel out let, air vent, drain plug, in let arrangement for diesel filling from exterior of canopy (without opening its panel) etc. complete all as specified and directed.(B) ALTERNATOR: Suitable rated at 50 KVA at 0.8 PF, 415Volt, 3 phase, 4 wire, 50 Hz, at 1500 RPM, Self excited and self regulated with AVR brushless excitation, screen protected, drip proof, Insulation class H IP-23 ventilated and confirming to BS : 5000 / IS:4722 suitable for engine as mentioned here-in-before MAKE: STAMFORD/Kirloskar Electric.(C ) Acoustic Enclosuer: M & L for acoustic for the above 50 KVA DG Set to reduce noise level to 75 dBA measured at 1.0 meter distance for audible frequencies as per guidelines of Central Pollution Control board and size not less than 2800x1150x1575mm and manufacture's specification and comprising of following form authorised OEMs' of Set manufactures specified:-(i) Sound insulation: 100 mm thick Rock wool .(ii) Outer body : Not less than 2.0 mm thick CRCA Sheet.(iii) Door : Not less than 2.0 mm thick CRCA Sheet (Density 64 Kg/Cum).(iv) Inner Surface : 1.0 mm thick CRCA/GI sheet.(v) Base frame : ISMC 300.(vi) Inside illumination : 1 No- 1x40 watt FTL fitting of Make: Philips/bajaj/Crompton

-

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanised earth strip 32x6 mm by means of bolts, nuts, and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I connected to main DB including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe, medium grade 50mm bore for earth lead and 20mm bore for watering, excavation and earthwork in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate including testing on completion.Note: GI earth strip 32x6 mm beyound 7.5m will be measured & paid for seperately.

4

-

-

... More
Supply, install, testing and commissioning indoor AMF (Automatic mains failure) LT panel cubical type factory fabricated, dust and vermin proof, double door, made out of 2mm thick CRCA sheet except bottom sheet 3mm thick, water and weather proof incl powder coating with siemens grey paint, IP54 class of protection, CPRI approved, pedestal type with suitable locking arrangement, mounted on 40mmx40mmx6mm angle iron frame consisting of all electrical/electronic accessories required to switch 'ON' the DG set of 50 KVA in automatic manner on failure of commercial supply and switch OFF the DG set or restoring of commercial supply including comprising the undermentioned items/accessories :-

1

-

-

... More
(a) Copper bus bar of 200 Amp capacity for phase & neutral mounted over the hygroscopic insulaters.(b) MCCB 100 Amp 25 KA with thermal magnetic setting range 0.7 to 1.0 and fixed short circuit current - 01 (I/c). (c) MCCB 4 pole 63 Amp 50 HZ 415 volt 25 KA -03 (For Lift & pump)(O/g).(d) Digital type voltmeter class 1 cat no PAMEBRITV-31 of Make: HPL or equivalent. (e) Phase indicator lamp -01 set.(f) MCB SPN 20 Amp 10 KA - 03 No .(g) MCB TPN 20 Amp 10 KA - 01 No .(h) Digital type voltmeter class 1 cat no PAMEBRITA-31 of Make: HPL or equivalent .(j) Phase Indiacting lamp RYB - 01 set .(k) On load Change over switch, 4 pole, 100A- 01 No. (l) Automatic main failure relay to act on failure of main commercial supply to start the DG set and to stop the DG set on restoring of commerial supply including showing parameters of DG set such as load in KW & Amp, Hr Run, luboil pressure, engine temp etc.-01

-

-

-

... More
Schedule-A' Part-XV 'LIFT '

-

-

-

... More
Supply, install, testing & commissioning 08 Passengers Lifts in bldgs Suitable to serve G+8 upper floors with Regenerative AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (02 Nos, one each in car & near Ground floor landing door and one with hand set in machine room ) all as specified below:- Make: OTIS/Schindler/Mitubishi/Thysenkrup/ESCON Note: Lift OEM to submit detailed specification/ design perameters, construction drg of all components of lifts as per IS-14665 for approval of accepting officer before execution of work. (a) Type of Lifts : 8 Passengers.(b) Load capacity : 544 Kgs.(c) Speed: 1.5 mtr/sec with single speed motor .(d) Power Supply : 415 volts, 3 phase AC, 50 Hz.(e) Type of Drive : Regenerative AC variable voltage & variable frequency drive.(f) Type of Machine: Gearless permanent magnet electirc motor with directly coupled horizontal traction machine.(g) Car size (Inside): Not less than 1.43 Sqm.

1

-

-

... More
(h) Car door and landing doors at all floors : Automatic center opening with VVVF door drive, opening size not less than 800mm x 2000mm, sliding type, fabricated by stainless steel sheet not less than 18 gauge having hair line finish (N-304).(j) Car enclosure: Manufactured with stainless steel frame stainless steel sheet not less than 18 guage with hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with CFL/LED light fitting complete, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel gril/wire mesh for protection.(k) Terminal buffers : Metal special spring buffers as per manufacturer specifications. (l) Door opening (Inside) : Protected by automatic centre opening stainless steel doors with hairline finish doors with clear opening size not less than 800 x 2000mm .(l) Door opening (Inside) : Protected by automatic centre opening stainless steel doors with hairline finish doors with clear opening size not less than 800 x 2000mm .(m) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design. Counter weight shall be cast iron as recommanded by OEM.(n) Flooring : Aluminum chequered plate 5mm thick complete.(o) Signals :-(i) Combined luminous hall buttons  with LCD/ VFD hall position indicators at all floors.(ii) LCD/ VFD for car position indicator of stainless steel.(iii) One No car operating panel with Luminous buttons in car (stainless steel).(iv) Car direction indicator in car & Landing.

-

-

-

... More
(v) Battery operated alarm bell & emergency light (rechargeable) along with suitable  maintenance free battery.(vi) Overload warning feature in car cabin (Display and announcing type both).(vii) Fireman’s switch one No per lift to be installed at ground Floor near landing door.(viii) All signal fixture & car operating panel on stainless steel face plate.(ix) Infra red door sensor safety edge of door for entire  height. (x) Built in announcing system 02 Nos, one each in car & near Ground floor landing door and one announcing system with hand set in machine room.  (xi) The interior of the car should be provided with a device that audibly indicates the floor lift car has reached and indicates that car entrance/exit door is open or closed. (xii) Stainless steel hand rail 40 mm dia all around 3 side inside the car cabin.     (p) Stops & Opening : 9-9 ( All opening on same side)   .(q) Safety device: Automatic Rescue Device (ARD)/ automatic landing device to be operating with maintenance free batteries for landing as specified. Make: OTIS / Mitubishi / Schindler / Toshiba / Hyundai /ADICON          .(r) Operation : Simplex, collective selective automatic operation with/without attendant.(s) Machine Room : Located above the hoist way (Detail As per appendix attached. Tenderer to inspect the same at site before quoting).(t) Hoist-Way Constn : (Existing at site detail as per Appendix attached. Tenderer to inspect the site before quoting).(u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size,necessary foundation to machine..(u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size,necessary foundation to machine.

-

-

-

... More
(v) Regenerative AC variable voltage variable frequency drive to make OTIS/Schinder/Mitubishi/Fuji/Toshiba/Yaskawa.(w) Control system shall be enclosed loop type.(x) Door shall have AC-VVVFcontrolled close loop operated.(y) Face plate shape shall be rectangular and stainlees steel with hairline finish.(z) Counter weight shall be of cast iron as recommended by OEM.(aa) Electric & earthing work :- (i) Necessary electric work such as supply and fixing of all control cables, fixing of panels etc required for smooth operation of lift. (ii) Material and labour for earthing not less than 2 Nos. with GI strip of size 32x6 mm upto test point, providing test point at nearest wall and extending the earthing connection from earth test point to lift/machine room by aluminum strip 25mm x 3mm of required length and making proper connection all as per good engineering practice. (ab) One number wall mounted type telephone instrument of make Crompton Greaves/Beetal installed inside of car cabin along with fixing arrrangement and telephone cable of suitable size from car cabin to machine room alongwith trailing cable. The telephone instrument shall be connected into telephone DB installed in the machine room. (ac) One number electrically operated Siren, operating voltage 240volts having audible range of 0.3km including independent switch inside of car cabin and connecting cable from car cabin to machine room.

-

-

-

... More
PART-XVI "PILE FOUNDATION " --------NIL------------

-

-

-

... More
PART-XVII '' DEMOLITION OF BUILDING'' ----- NIL--------

-

-

-

... More
PART-XVIII '' SCHEDULE OF CREDIT'' (CREDIT FOR MATERIAL, SHEDS/ STORES AND T&P AVAILABLE AT WORK SITE) Total of Schedule-'A' Part-XVIII B/F from serial page No. 45C

1

-

-

... More
NOTE:- (i) Contractor shall quote the percentage addition over lumpsum price of credit for material, sheds/store and T&P inserted by MES and carry forward the corresponding amount. However the quoted percentage shall not be less than NIL percent (i.e. shall not be on minus side). In case contractor’s quoted percentage is less than 0% (zero percent) it shall be restricted to 0% (zero percent) & total amount accordingly be corrected. The contractor shall take this aspect in account and nothing extra whatsoever shall be admissible on this account. (ii) This schedule of credit amount will be deducted from the contract sum to arrive quoted contract sum.

-

-

-

... More
PART-XIX ( Rectification of Defects in Work Already Executed)

-

-

-

... More
Material and labour for Demolition of cement concrete (unreinforced/reinforced) in ground floors and paving's n exc 15 cm thickness (below or above ground level) all as specified and directed.

252.96

-

-

... More
Breaking carefully the loose concrete of distressed member without damaging existing strong concrete by means of sharp chissle which should tempered regularly of high frequency low impact hammers used. cleaning the surface by water jet pressure pump at 4 to 5kg / sqcm pressure to remove chlorides and loose particles air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. The damaged ceiling / concrete will be measured etc. complete all as directed.

179.52

-

-

... More
Providing and applying two coats of concrete penetrating hi-tech corrosion inhibition mechanism inhibits corrosion of steel in concrete at the poles. Cathode & anodic simultaneously on concrete surface which is prepared earlier. The work should be carried out with all safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. The damaged ceiling / concrete will be measured etc.complete all as directed.

1419.36

-

-

... More
Providing and applying approved epoxy resin EPI Bond of Krishna Conchem or equivalent before polymer plaster / concrete to have the perfect bond between old concrete and new concrete/polymer plaster surface confirming to ASTM-C-882-87 using nylon brushes scaffolding labour etc complete.

469.2

-

-

... More
Making up distressed / loose / cracked / porous carbonated, loose part of concrete and repairing the damaged surface of concrete with fiberous micro concrete having dual shrinkage compensation Master Emaco S 346 BASF/FOSROC / Krishna Conchem or equivalent and repairing the damaged surface of concrete, fixing the form work / shuttering across the profile of damaged structural element. Micro concrete should be mixed homogeneously pour the free flow ready mix micro concrete mix with 5 L to 7 L of water in the form work. The work should be carried out with all safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. The damaged ceiling / concrete will be measured etc.....complete.

82110

-

-

... More
Providing and fixing Shear connectors of 8mm dia. HYSD steel with two component, styrene & cement free, epoxy-acrylate fixing and anchoring compound supplied in self mixing cylinder-in-cartridge from that avoids site mixing using standard sealant applicator gun after drilling holes of 12 mm diameter to a minimum depth of 100 mm at required locations, inclusive of all material, manpower and equipment.

1408

-

-

... More
Drilling and fixing 10 mm, 12 mm, 16 mm, 20 mm re-bars with 'Fischer / Hiliti' system and chemical etc. Note:- Steel shall be measured and paid separately .

1456

-

-

... More
S & F TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns / piles, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed

6930.79

-

-

... More
Injecting low viscosity grade epoxy grout by pressure by epoxy or grouting pump and compressor. Mixing :- Material components DR BECK 505C + EK411 HARDNER + SOLVENT 100:50:50 weight batching. Grouting :- fill the grouting gun with resin mix maintain desired pressure at exit (7 to 10 kg /sqcm) by monitoring pressure gauge at exit. Grout the material through prefixed nozzles in the structural elements till its refusal, seal the nozzle with epoxy sealant (EPCO 10 10) after the refusal. Monitor leakages through other nozzles while grouting and seal them as per the requirement. Repeat the process all the nozzles. Complete the poeration at pot life of material, grouting is continued to all the nozzles from bottom to top and not from top to bottom. cleaning the gun and accessories (Valves, pipes and other fixtures) with T-60 thinner / or equivalent of dr. fixit. Krishna chemical, sunanda etc. The work should be helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor etc. complete.

52.23

-

-

... More
Removing any kind of debris including loading and unloading in truck and remove to a distance beyond 5Km and deposited including spreading and levelling as directed at a level n.exc 1.5 m from starting point complete.

260.14

-

-

... More
Providing Autoclaved Aerated Concrete Block masonry of Ecolite or equivalent make confirming to IS:2185(Part 3)-1984 in extra fine jointing mortar of fixoblock of Ultra tech or equivalent in superstructure including striking joints raking out joints and scaffolding etc. complete. The test shall be carried out conforming to IS:6441 (Part 1)-1972.

1093

-

-

... More
Providing fly ash brick masonry with conventional /IS type bricks in cement mortor 1:6 in superstructure including skirting joints, raking out joints ,watering and scaffolding etc complete all as directed.

1093

-

-

... More
Removing the existing rust with wire brush. Making the surface clean and dry. Providing and Applying a coat of Rust remover on the corroded steel and second coat if required. Providing and Applying two coats of Anticorrosive corrosion inhibitor coating for steel including all required necessary tools and tackles.

200

-

-

... More
M & L for providing and injecting chemical emulsion for post constructional Antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate 7.5 litre persqm of vertical surface of the sub structure to a depth of 300mm including excavation channel along the wall and rodding etc.complete all as specified and as directed.

185

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.