Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Coronavirus COVID 19
Eprocure

Opening Date

11 May 2019

Closing Date

7 Jun 2019

Tender Amount

₹ 91,65,990 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Manning and operation of water supply installation consisting of electrically operated monoblock pump sets of capacity as mentioned below including taking care of from any pilfrage/damage daily in one shift from 1800 hrs to 0200 hrs including Sunday/holiday at HQ MAGNA and Godfrey clinic pump house all as specified and directed by Engineer-in-Charge. (a) 7.5 HP - 02 No. (for fresh water) (b) 5 HP- 02 No. (for fresh water)

11

-

-

... More
Manning and operation of water supply installation consisting of electrically operated monoblock pump sets of capacity as mentioned below including taking care of from any pilfrage/damage daily in one shift from 0900 hrs to 1700 hrs including Sunday/holiday at FLOTILA NIWAS and NMRL pump house all as specified and directed by Engineer-in-Charge

11

-

-

... More
Manning and operation of electrical Distribution system 440 V/ 230 Volts at INS AGNIBAHU MES Complaint Cell by employing the below mentioned man power in One shifts per day including Sunday / Holidays: i) Skilled Electrician-01No. Per shift. Note:- Shift timings shall be are as under:- a) First shift: 0900 hrs. To 1700 hrs.

11

-

-

... More
Manning and operation of electrical receiving substation 11KV/ 440 Volts at SOMA power house by employing below mentioned man power in three shifts per day including Sunday / Holidays:- (i) Skilled Electrician-01No. Per shift. Note: Shift Timings are as under:- (a) First shift: 0600hrs. To 1400hrs. (b) Second shift : 14.00hrs. To 2200 hrs. (c) Third shift : 2200 hrs to 0600hrs

33

-

-

... More
Supply only CALCIUM HYPO CHLORITE high strength calcium based granular disinfectant packed in 45 Kg each plastic drum for chlorination of water/Water treatment. Make :Declibac/Sree Rayalaseema/Potter&Watts(As per E-in-C's approved)

450

-

-

... More
Supply & Fix set of five pieces chlorine tablets of size 50.80 mm in diameter ( packed in plastic sealed disposable packet with arrangement for appropriate water contact with the tablet and circulation through the plastic packet, suitable for operation through suitable feeder for disinfection of water pressuried line. Replacement indication : Visual & weight variation)

50

-

-

... More
Notes for item Nos 1 to 7:- (a) Rates quoted by the contractor shall be deem to be included cleaning of installation and surrounding area of pump house, operation of chlorine dosing system, taking care from any pilferage/demage of installation and maintaining documents/registers chlorine testing register, duty roster and attendance register etc as directed by Engineer-in-Charge (b) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. In case payments are made in current coin or currency notes, contractor shall submit certificate alongwith undertaking of employee that asking for payment other than by cheque or by crediting in the bank account of the empolyee. The contractor shall submit proof to Engineer-in-Charge before claiming any payment.

-

-

-

... More
(e) Contractor has to submit proof of payment of EPF subscription made by him alongwith RAR failing which RAR will not be progressed for payment. (f) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (g) Contractor shall quote the rates considering their monthly leaves, releiver etc as per labour laws and nothing extra shall be paid on account of the above. In case of absence of staff/tradesman from duty, payment of that day will not be paid. In addition to that a penalty of Rs 1500/- per day per person will be recovered from contractors dues. Also in case of long absence continuously (more than one week) of staff/tradesman, the penalty shall be recovered Rs 3000/- per day per person and payment of that day will not be paid. The contractor shall have no claim on this account. (h) Contractor has to supply three sets of Tools and Plants to the labours employed by him and should be placed with the safe custody of department. Rates quoted shall be deemed to be included the above provision.

-

-

-

... More
Material & labour for detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas and commissioning and testing the window type air conditioner unit 1.5 Ton capacity complete all as specified and directed.

150

-

-

... More
All as per item No 11 above but of 2.0 Ton capacity

35

-

-

... More
All as per item No 11 above but of Split type AC 1.5 Ton Capacity.

180

-

-

... More
All as per item No 11 above but of Split type AC 2.0 Ton Capacity.

25

-

-

... More
All as per item No 11 above but of Water cooler 40/60/80 Ltrs. Capacity.

20

-

-

... More
All as per item No 11 above but of Water cooler 120/150/170 Ltrs. Capacity.

15

-

-

... More
All as per item No 11 above but of Refrigerator 100/165/180/230 Ltrs. Capacity.

10

-

-

... More
All as per item No 11 above but of Refrigerator 260/280/310/350 Ltrs. Capacity.

8

-

-

... More
Material & labour for Taking out window type Air conditioner 1.0/1.5/2.0Ton capacity of any make from its original location, removing the dust from body with blower, cleaning the condenser and cooling coil by using water and caustic soda, painting the base tray with one coat of black enamel paint checking all the connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum etc. oiling/ greasing of fan motor checking serviceability and refixing it in its original place including testing commissioning for 1.0/1.5/2.0 Ton of AC of any make all as specified & directed by Engineer-in-charge.

200

-

-

... More
All as per item No 19 above but of split type AC 1.5/2.0 Ton capacity complete out door and indoor. (Note for item nos.09 &10:Refrigerant gas will be measured & paidly separately as supply only under respective items.)

250

-

-

... More
Cutting out existing wall / widow grills / existing window frame for making suitable space to accommodate window type AC making frame with 2nd class hard wood piece of min of 50 x 50 mm size & up to 60 cm height for fixing of outer cover of AC & supporting structure made out 40 mm x 40 mm x 5 mm thick MS angle iron duly grouted in wall & closing the open space around ACs with the help of 6 mm thick ply wood exterior grade to close air leakage tightening with woolen felt (green felt) and painting to wooden structure matching to interiors as directed & steel structure with one coat of primer and two coats of synthetic black enameled paint and fixing only window type AC all as directed by Engineer-in-Charge including complete connecting and testing all as specified and directed by Engineer-in-Charge.

6

-

-

... More
All as per item No 21 above but shifting of AC from existing location to new location including making good of old location all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Material & labour for taking down Corroded body base tray etc of window type air conditioners and replacement of body base tray etc out of 18 SWG and other portion with MS sheet 20 SWG including motor mounting frame nuts and bolts suitable size painting and necessary insulation complete for 1.0 / 1.5 / 2.0 Ton capacity Air conditioner.(Note : For dismantling compressor for body work and reassembling shall be inclusive in quoted rate)

20

-

-

... More
Material & labour for preparation of old painted surfaces of Refrigerator any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.

10

-

-

... More
Material & labour for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.

20

-

-

... More
Supply, install, test & commissioning new compressor sealed reciprocating type suitable for window type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas etc. complete all as specified & directed by Engineer-in-charge including taking out old . Make : Voltas/usha Shriram/Bluestar /samsung/Hitachi/videocon/LG/Carrier/Daikin etc. as per existing make at site.

40

-

-

... More
All as per item No 26 above but of 2.0 Ton capacity

12

-

-

... More
All as per item No 26 above but of Split type AC 1.5 ton capacity

50

-

-

... More
All as per item No 26 above but of Split type AC 2.0 ton capacity

10

-

-

... More
All as per item No 26 above but of Refrigerator 100/165/180/210 Liters Capacity.

8

-

-

... More
All as per item No 26 above but of Refrigerator 260/280/310/350 Liters Capacity.

8

-

-

... More
All as per item No 26 above but of Water coolers 40 / 60 /80 Liters capacity

12

-

-

... More
All as per item No 26 above but of Water coolers 120/150/170 Liters capacity

10

-

-

... More
All as per item No 26 above but of deep freezers of capacity 310ltrs/410Ltrs. Capacity

2

-

-

... More
Taking down carefully split type AC of capacity 1.5 / 2.0 ton & refixing on new location complete with pre fabricated brackets/ frame work as required complete & making the good existing surface with out any damage out & indoor unit complete.

20

-

-

... More
Removing the existing unserviceable coil burnt fan motor from window/Split type AC of capacity 1.0 / 1.5 / 2.0 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete.

50

-

-

... More
Supply & fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete.

25

-

-

... More
Supply,fixing and testing fan blade suitable for window/split type Air conditioner of 1.0 / 1.5 / 2.0 Ton capacity including removing old fan blade.

55

-

-

... More
Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old fan blade.

20

-

-

... More
Replacing old defective blower drum and supply & fix blower drum suitable for window type Air conditioner of 1.0 Ton / 1.5 Ton / 2.0 Ton capacity.

30

-

-

... More
Replacement of front cover grill suitable for window type AC 1.0 Ton / 1.5 Ton / 2.0 Ton capacity AC of various makes.

25

-

-

... More
Replacement of starting capacitor 60 - 80 mfd.Make:(ANAND/UNIQUE/ KELTRON)

180

-

-

... More
Replacement of starting capacitor 80-100 mfd.Make:(ANAND/UNIQUE/ KELTRON)

150

-

-

... More
Replacement of starting capacitor 100 -120 mfd.Make: ANAND/UNIQUE/ KELTRON)

80

-

-

... More
Replacement of running capacitor 25 MFD (Make : Asian / Epcos)

100

-

-

... More
Replacement of running capacitor 36 MFD (Make : Asian / Epcos)

150

-

-

... More
Replacement of running capacitor 45 MFD (Make : Asian / Epcos)

70

-

-

... More
Supply & Fix of selector switch push button type for window type AC any make 1.0 Ton / 1.5 Ton / 2.0 Ton capacity (Make : Arvind / Usha)

45

-

-

... More
All as per item No 48 above but rotary type

4

-

-

... More
Supply & fix of thermostat switch for window type AC of capacity 1.0 Ton / 1.5 Ton / 2.0 Ton capacity (Make :- Indofoss / Ranutral)

60

-

-

... More
Supply & fix of thermostat switch for split type AC of capacity 1.5 Ton / 2.0 Ton capacity (Make :- Indofoss / Ranutral)

50

-

-

... More
Supply & fix of thermostat switch for Refrigerator of any capacity (Make :- Indofoss / Ranutral)

15

-

-

... More
Replacement of thermostat switch for Water Cooler of any capacity (Make :- Indofoss / Ranutral)

20

-

-

... More
Taking out old unserviceable and Supply & Fix new over load relay suitable for Window/Split type AC of 1.0 Ton / 1.5 Ton / 2 Ton capacity all as directed.(Make : Arvind / Usha / Rametrol)

80

-

-

... More
Taking out old unserviceable and Supply & Fix new over load relay suitable for water cooler of any capacity all as directed(Make : Arvind / Usha / Rametrol)

45

-

-

... More
Taking out old unserviceable and Supply & Fix new over load relay suitable for Refrigerator of any capacity all as directed(Make : Arvind / Usha / Rametrol)

25

-

-

... More
Supply & fix of Float valve suitable for Water cooler of any capacity

20

-

-

... More
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete.

250

-

-

... More
Supply and lay cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as directed by Engineer-in-Charge

150

-

-

... More
Supply and lay PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete.

120

-

-

... More
Supply & fix push cock / lifting cock of 15 mm bore in repair for water cooler of any capacity

20

-

-

... More
Supply & fix PVC connecting pipe with brass nuts and washers at both ends of length not exc 60 cms for connection of water coolers

20

-

-

... More
Supply & fix GI water tray 2 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe.

60

-

-

... More
Supply & Fix PVC drain pipe with necessary saddles of 25 mm size to be used as out let drain to be fixed all as per direction of Engineer-in-Charge

100

-

-

... More
Supply and fix sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps all as specified & directed by Engineer-in-Charge.

40

-

-

... More
Taking out old unserviceable and Supply & Fix new magnetic gasket for refrigerator of 165 / 286 / 310 liters complete all as directed by Engineer-in-Charge.

10

-

-

... More
Taking out old unserviceable condenser coil of 1.5 Ton window type AC any make with sins cutting in let outlet connecting copper pipe and providing new condensor coil with sins and connecting in let out let copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
All as per item No 67 above but for 2.0 ton window type AC complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
All as per item No 67 above but for 1.5 ton Split type AC complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
All as per item No 67 above but for 2.0 ton Split type AC complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Removing electronic unserviceable circuit boards from window type AC 1.5 ton / 2.0 Ton capacity and replacing with new circuit boards and connecting with system with replacing remote control hand set and testing complete all as specified and directed

10

-

-

... More
All as per item No 71 above but for 1.5 Ton / 2.0 Ton Split type AC complete all as specified and directed

25

-

-

... More
Supply & Fix blower fan motor capacitor 4 MFD (Make : Asian / Keil)

70

-

-

... More
Supply & Fix blower fan motor capacitor 6 MFD (Make : Asian / Keil)

70

-

-

... More
Supply & fix of electric bulb suitable for refrigerator of any capacity screw type / pin type (Make :- Philips / Equivalent)

8

-

-

... More
Supply & fix of Air filter for window type AC of any capacity and type by Engineer-in-Charge.

30

-

-

... More
Material & labour for replacement of damaged outer cover for window type Air conditioner of any capacity and size made out of GI sheet of 20SWG all as specified by Engineer-in-Charge.

25

-

-

... More
Taking out existing unserviceable over load protector and Supply & Fix new over load protector for 1.0 /1.5 /2.0 Ton capacity window type Air Conditioner (Make : Usha/ Ranutral).

20

-

-

... More
Supply and fix in repair sensor remote plate(PCB) suitable for 1.5/2.0 Ton capacity split type AC etc. complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Supply of sensor remote handset suitable for 1.5/2.0 Ton capacity split type AC etc. complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Supply and fix in replacement multipurpose door lock with duplicate key of refrigerator of any make &capacity etc complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Taking out old unserviceable cooling coil of window/split type AC any capacity and any make with sins cutting in let outlet connecting copper pipe and providing new cooling coil with sins and connecting in let out let copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply & fix Condensing unit Bracket of any size and type suitable for supporting to out door unit of split type AC including nut, bolts & washers etc complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supply and fix in replacement Contactor of split type AC any capacity complete all as directed by Engineer-in-Charge.

15

-

-

... More
Supply and fix in replacement sunction & liquide line valve of size (5/8"&1/4")/(5/8"&3/8") suitable for split type AC complete all as directed by Engineer-in-Charge.

20

-

-

... More
Dismantling and takingout old unserviceable cooling tower and Supply, install, commissioning of New brand Draft rectangular counter flow type Cooling tower body of capacity 80 TR Comprising of FRP casing FRP fan stack,FRP Fan,PVC header with branches totally enclosed weather proof enclosure complete testing all as directed by Engr in Charge.Make : Mihir Engineers Pvt Ltd./ Advance cooling Tower Ltd /Paharapur cooling tower Ltd.

1

-

-

... More
Spare parts of Draft rectangular counter flow type Cooling tower of capacity 80 TR such as Electric Motor, PVC Fills,PVC Eliminators, MSHDG Structure and necessary Hardware etc. including addition alteration to water inlet and outlet pipe connection Complete testing all as directed by Engr in Charge.

1

-

-

... More
Dismantling and takingout old unserviceable cooling tower and Supply, install, commissioning of New brand Draft rectangular counter flow type Cooling tower body of capacity 35 TR Comprising of FRP casing FRP fan stack,FRP Fan,PVC header with branches complete testing all as directed by Engr in Charge.Make : Mihir Engineers Pvt Ltd./ Advance cooling Tower Ltd /Paharapur cooling tower Ltd.

1

-

-

... More
Spare parts of Draft rectangular counter flow type Cooling tower of capacity 35 TR such as Electric Motor, PVC Fills,PVC Eliminators, MSHDG Structure and necessary Hardware etc. including addition alteration to water inlet and outlet pipe connection Complete testing all as directed by Engr in Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.