Kerala State Electricity Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 5,00,000Document Cost
₹ 17,700Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_KSEB_302648_1Bid Award Id
ViewTender No
KL KSEB DRIP/ W17/INSTR/1(G)/CE-10/2019-20Tender Authority
Kerala State Electricity Board ViewPurchaser Address
-Website
http://http://www.kseb.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and installation of Normal Plumb line device as per specifications and provided with two travelling telescopes (one each for the X and Y axes), one of the telescopes with a right angle prism before the objective lens to facilitate observation from the same direction and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
3
-
-
Automation of existing Plumb line device at Cheruthoni and Kulamavu dams under Idukki HEP and Idamalayar dam as per specifications and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
18
-
-
Supply and installation of Resistance type Temperature sensor with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection, 2 core shielded cables and other accessories as required and as per specifications and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
119
-
-
Supply and installation of vibrating wire/ MEMS biaxial type Tilt meter with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection, 4 core shielded cables and other accessories as required and as per specifications and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
33
-
-
Supply and installation of vibrating wire type Joint meter/ Crack meter with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection, cables and other accessories as required and as per specifications and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
192
-
-
Supply and installation of mechanical, vibrating wire type Uplift pressure meter with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection, cables and other accessories as required and as per specifications and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
114
-
-
Supply and installation of V-Notch weir to measure the flow rate in the channel both electronically and mechanically with all accessories required to transmit the output proportional to the water level to the observation room through a four core jelly filled cable. The Notch shall be graduated to measure the flow directly. It shall be conforming to the specifications. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
61
-
-
Supply and installation of vibrating wire Piezometer with stainless steel enclosure with stainless steel filter stone, thermistor, unvented, sensor mounting support, IP68 or NEMA-4 protection, cables and other accessories as required and as per specifications and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
3
-
-
Supply and installation of Strong Motion Accelerograph with built in acquistion module, GPS Set pole & antenna, data logger, cables and other accessories as required and as per Technical specifications and connecting to the data transmission system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
10
-
-
Supplying, laying and wiring all power cables and data cables wherever required for connecting instruments with data collection, transmission equipment, antenna including laying them in conduits, wiring and clamping to walls, laying underground, providing terminal switches and connections, cutting concrete and making good, all earth excavation and backfilling required etc. complete for connecting all equipments of one dam
19
-
-
Supply and installation of Power supply for Data Terminal Equipment (data collecting Unit) ,GPRS modem/ VSAT , all sensors and meters with backup power supply with suitable rating and capacity for 5 hours in case of failure of ac power supply and 5 year warranty
19
-
-
Supply & installation of items/equipments required for Surge Protection, Earthing, Lightening Protection as per relevant standards.
19
-
-
CENTRAL MONITORING STATION AT DAM SAFETY ORGANIZATION AT PALLOM- Providing and Establishing Dam Management System(DMS) at Research & Dam Safety Organisation Office located at Pallom, Kottayam (excluding cost of Civil works) and shall include Design ,supply, installation, testing, commissioning of real time DAM MANAGEMENT SOFTWARE capable of processing and managing data as decribed in specification from 19 dam sites &AWS.The software shall be able to perform all functions described in specification. Further updates and patches shall be provided without any additional cost for a period of 5 years. The software shall be able to communicate with Data terminal equipments at 19 Dam sites in IEC 60870-5-104 protocol simultaneously.The software shall be able to exchange data with other control centers in ICCP and other latest protocols.Data display functions shall be available in software to display data in Large LED Displays and VPD system.Licence to use and software keys shall be handed over to the owner at the time of final acceptance. Repair, management , upgradation , inclusion of new dam sites shall be contractors responsibility for a period of 5 years. All softwares of DMS system provided , including the Operating system, Database and support software, shall comply with the industry-accepted software standards. In areas where these organizations have not yet set standards, the software shall comply with those widely accepted defacto standards put forth by industry consortiums, such as OSF and X/Open. TheRDBMS and support softwares (programming language compilers, database development and maintenance, display development, network services,Report generation, diagnostics and Backup utilities) provided by Contractor and the original software manufacturer as necessary to support the applications of DMS system.
1
-
-
Supply, installation, testing, commissioning of hardware for DMS includes DMS (Dam Manegement system) server, database server, Historian server, Communication Front End (CFE),web server,MODEMs for communication,internal and external fire wall, Engineering Laptop,Laser printers, work stations,55" Commercial HD LCD with LED backlit (PP switches, Routers, cables , ac power distribution from online ups DB s, GPS system for time synchronisation, LAN cables, POWER cables, earthing, metal cabinets of suitable IP standard and exhaust fans for installation of switches, routers, servers,etc. .The hardware and software for DMS shall meet 24/7 operational requirements that all equipments such as Servers to perform functions of Communication Front End, Database server, Storage servers sufficient for 30 years, Web Server with internal and external firewalls, Operator Console, work station, Display units, backup servers,routers, printers, etc. The Supply shall include all accessories such as Servers to perform functions of a Communication Front End, Database server, Storage servers sufficient for 30 years, Web Server with internal and external firewalls, Operator Console, work station, Display units, server software backup servers,routers, racks, printers, etc. and connecting all the data collection units established at Field units for compiling the data collected at collection units for storage and retrieving when ever found necessary and shall be conforming to the specifications
1
-
-
supply , installation, testing, commissioning of a back up data server at dam safety division Vazhathope, Idukki disrict which shall be a replica of the data back up server at dam safetyOrganisation Head quartes at Pallom including providing a UPS of minimum 700VA and capacity for 6 hrs in case of power failure with 5 years warantee . The backup server shall automatically update any changes at Data base server at Pallom& shall store per minute snap shot in such a way that the DMS at Pallom shall function without interuption
1
-
-
Design , supply , installation, testing, commissioning of Data Terminal Equipment (DTE) as detailed in specification for data collection and transmission in IEC60870-5-104, shall be provided with metal cabinet, front glass door, wall mounting type, with power supply, field cable terminal blocks, heater, light, GPRS modem,all cabling from sensors and meters, modem power supply, antenna, lock and key. The DTE shall have sufficient number of analog and digital data input for data processing and CPU with latest firmware version . The DTE shall be of latest version from a reputed manufacturer.All programming parameters and users manual shall be in English language. One Laptop for programming with support software also shall be provided for entire supply. Additional spare inputs shall be provided for adding additional instruments later as per detailed specifications and including complete wiring and commissioning etc complete as per specifications
20
-
-
Data integration and End to end testing of collected data at Dam Management System from 19 Dam sites and all AWS . Display of real time data in the existing video wall, cables, accessories and programing also included.
1
-
-
Providing communication channels of sufficient bandwidth between DMS at DSO Head quarters and Data terminal equipment at 19 Dam sites. The communication channel shall be of GPRS leased line or VSAT where GPRS signals are not available. The communication channel shall offer disturbance free communication in IEC 60870-5-104 protocol and updation of data within 6 seconds.The cost for arranging and maintaining the channels for five years is included. Terminal equipments and its power supply for communication channel shall also be provided.
1
-
-
Supply and installation of online UPS and battery for main control room at Pallom with suitable rating and capacity with 2 hours backup,output Distribution panel with MCBs of sufficient rating, input Distributiotion panel with 2 AC power supply source and 1 Diesel generator source,NO/NC contacts for alarm integration, shall offer 24/7 operation and 5 year warranty
1
-
-
Supply & installation of items/equipments required for Surge Protection, Earthing, Lightening Protection for all equiments supplied as per relevant standards.
1
-
-
Installation, testing and commissioning of 7.5 KVA Silent type DG set complete with all accessories including civil works such as foundation of DG sets, trenches for cabling, earthing etc., exhaust piping with MS rod of suitable diameter, heavy duty bend and flexible connector etc, supply and laying of 4*16 sq mm PVC insulated &PVC sheathed/XLPE aluminium armoured cable conductor from DG set to panel board at Control room with necessary cable lug, gland, gland plate and cable tray as required for proper termination of cable from both ends, supply and laying 6 SWG copper wire for earthing including 2.5m long GI pipe earth stations as per requirement, supply and fixing of 63A change over switch including suitable metal box, documentation, preparation and getting approval from Electrical Inspectorate including all fees, supply and wiring KSEB Indication lamp etc complete at Central Control Room at Pallom
1
-
-
Providing of high quality furniture for operator console, work station, almirah for keeping project documents and reports, high quality chairs for viewing video wall, operator, etc
1
-
-
Providing communication channels of sufficient band width ( not less than 2MBPS) between DSO main control center and back up server at Dam safety Division Vazhathope with terminal equipments and power supply including cost of arranging and maintaining the channels for five years.
1
-
-
Items not included in the real time data transmission
-
-
-
Supply of Electronic Total Station having angular Least count of 0.1" & 0.1mm and accuracy of 1" both for HZ and Vt. Angles, 1mm + 1.5ppm distance measurement accuracy, can measure a distance of 3.5km with single prism and 250m with tape, 500m without reflector under average atmospheric conditions, having internal memoroy and USB drive, key board on both faces etc. Tribrach with optical plummet, Wooden Telescopic Tripod, Plug in Cam - corder, battery (rechargeable), Charger with adapter, two circular prisms (with holder), target plate, Reflector pole (two numbers), with telescopic circulat bubble etc. On board application software complete as per the technical specifications
1
-
-
Supply and installation of Resistance type Temperature sensor with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection, 2 core shielded cables and other accessories as required and as per specifications and connecting to the data logger system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
5
-
-
Supply and installation of vibrating wire/ MEMS biaxial type Tilt meter with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection, 4 core shielded cables and other accessories as required and as per specifications and connecting to the data logger system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
2
-
-
Supply and installation of vibrating wire type Joint meter/ Crack meter with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection, cables and other accessories as required and as per specifications and connecting to the data logger system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
5
-
-
Supply and installation of mechanical, vibrating wire type Uplift pressure meter with stainless steel enclosure, sensor mounting support, IP68 or NEMA-4 protection,cables and other accessories as required and as per specifications and connecting to the data logger system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
17
-
-
Supply and installation of V-Notch weir to measure the flow rate in the channel both electronically and mechanically with all accessories required to transmit the output proportional to the water level to the observation room through a four core jelly filled cable. The Notch shall be graduated to measure the flow directly. It shall be conforming to the specifications. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
26
-
-
Supply and installation of vibrating wire Piezometer with stainless steel enclosure with stainless steel filter stone, thermistor, unvented, sensor mounting support, IP68 or NEMA-4 protection, cables and other accessories as required and as per specifications and connecting to the data logger system for obtaining the data in the data centre. Total cost of the item shall include charges for supply, installation, transportation, programming, testing and commissioning including providing training, documentation and technical support upto the final acceptance of the equipment as per specifications and conditions of contract.
16
-
-
Providing Settlement Plate/ Survey markers including fixing in position as per specifications and directions at site
116
-
-
Supply of rugged, hand held mobile, field data logging device and data logging software capable of communication with the dam safety monitoring software,
5
-
-
Any other item not covered herein and required for establisment of theRTSHM&EW system at various dam site of KSEBL (specify details)
1
-
-
Related services during Warranty/ Comprehensive Operation and Maintenance Contract Period Charges for related services during the warranty including cost for comprehensive operation and maintenance of entire network for 5 years and the cost of all spares required to be replaced and maintenance cost upto the end of AMC period are included. Training to be imparted during the period as per Conditions of Contract .
(Amount for AMC for a period of five years)
5
-
-