Indian Oil Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Indian Oil Corporation Limited - IOCL Tender

Eprocure

Opening Date

25 Apr 2019

Closing Date

Cancelled

Tender Amount

₹ 51,40,86,130 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

438016

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

35

4460400

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

1035096

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

47

3937660

-

... More
Supply of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

34

3789334

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

22

233640

-

... More
Supply of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

12

351295

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

12

407524

-

... More
15 M pole with Accessories as per specification of Tender

9

382851

-

... More
7 M pole with Accessories as per specification of Tender

7

103596

-

... More
10 M pole with Accessories as per specification of Tender

2

70800

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

35

1106014

-

... More
Supply of 20 Meter Tower along with foundation.

2

413000

-

... More
Supply of rack mounted CCTV Server (s) (N:N) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

1308631

-

... More
Supply of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

6114413

-

... More
Supply of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

540381

-

... More
Supply of minimum 55" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Security Room, TM room) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

2

204140

-

... More
Supply of minimum 75" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Control room ) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

1

294764

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

1062000

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

132144

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

1317824

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

1049728

-

... More
Supply of parallel redundant UPS of minimum capacity of 10 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

561552

-

... More
Supply of UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

17700

-

... More
Supply of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

16262

-

... More
Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

236000

-

... More
Supply of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

8250

535425

-

... More
Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

451468

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

10200

661980

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

3000

230100

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

10200

1263780

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

4500

2124000

-

... More
Flameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

27

105265

-

... More
Supplyof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

2000

129800

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Supply of 400 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

47

388220

-

... More
"Lighting Sub Distribution Board (LSDB) :Design ,Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. Vendor to advice to Design as per site location. "

1

59000

-

... More
Flameproof 16A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

13

383500

-

... More
Flameproof 25A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

47

233153

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

4900

1445500

-

... More
Supply of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

5640

500493

-

... More
OTHER ACCESSORIES

-

-

-

... More
Supply of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

38515

-

... More
Supply of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

44250

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

5250

3097500

-

... More
150 mm width

200

63720

-

... More
100 mm width

200

35400

-

... More
50 mm width

200

25960

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

180

318600

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

150

708000

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

42

2577120

-

... More
Supply of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

14160

-

... More
Supply of Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

30

498432

-

... More
Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

2500

566400

-

... More
As built documentation for entire CCTV System : 3 sets of Hardbound and 5 sets of Soft form on DVDs,

1

23600

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

100

6490

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

100

7174

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

100

12390

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

100

47200

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

100

35872

-

... More
Supply , Design , installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment or supply the Power distribution panel for the LED Lights as per site requirements. Vendor to advice to Design as per site requirements without any price implementation.

1

52864

-

... More
PART-B INSTALLATION, ERECTION, TESTING & COMMISSIONING

-

-

-

... More
Installation, Testing & Commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

8

18880

-

... More
Installation, Testing & Commissioning of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

23600

-

... More
Installation, Testing & Commissioning of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

35

123900

-

... More
Installation, Testing & Commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

11800

-

... More
Installation, Testing & Commissioningof IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

47

110920

-

... More
Installation, Testing & Commissioning of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

34

40120

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

22

51920

-

... More
Installation, Testing & Commissioning of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

12

28320

-

... More
Handling , Installation, Testing & Commissioning of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

12

99120

-

... More
15 M pole with Accessories as per specification of Tender

9

53100

-

... More
10 M pole with Accessories as per specification of Tender

9

53100

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

35

165200

-

... More
7 M pole with Accessories as per specification of Tender

7

41300

-

... More
20 Meter Tower along with foundation.

2

82600

-

... More
Installation, Testing & Commissioning of rack mounted CCTV Server (s) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

4720

-

... More
Installation, Testing & Commissioning of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

10030

-

... More
Installation, Testing & Commissioning of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

7080

-

... More
Installation, Testing & Commissioning of Ultra High Definition (4K) LED Display for the Monitoring with minimum 55" or more, supporting HDMI2.x resolution for location incharge room and Security room

2

4720

-

... More
Installation, Testing & Commissioningof Full HD LED Display for the Monitoring with minimum 75" or more, supporting HDMI2.x resolution for control room - Terminal

1

2360

-

... More
Installation, Testing & Commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document.

2

10620

-

... More
Installation, Testing & Commissioning of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document.

2

9440

-

... More
Testing & Commissioningof Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

11800

-

... More
Testing & Commissioningof Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Analytics Server with OS, Antivirus etc including analytic license for each camera complete as per specifications and Tender Document

1

59000

-

... More
Installation of of parallel redundant UPS of minimum capacity of 10 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

11800

-

... More
Installation, Testing & Commissioningof UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

2360

-

... More
Installation, Testing & Commissioning of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

2360

-

... More
Laying , Testing & Commissioningof all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

59000

-

... More
Laying, Testing & Commissioning of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

8250

340725

-

... More
Installation, Testing & Commissioningof required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

59000

-

... More
Laying Testing & Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

10200

204612

-

... More
Laying, Testing & Commissioning of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

3000

134520

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

10200

421260

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

4500

212400

-

... More
Installation, Testing & CommissioningFlameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

27

31860

-

... More
Installation, Testing & Commissioningof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

2000

70800

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Installation, Testing & Commissioning of minimum 400 Watt or as per site requirement whichever is higher LED flood light with suitable current control driver circuit including mounting arrangement complete as per specification and tender document. The required Lux level on either side of the perimeter at a distance of 20m from boundary wall shall be minimum 7 Lux and the light to be fitted on CCTV poles at a height of 8 m across the perimeter.

47

27730

-

... More
Installation, Testing & Commissioning"Lighting Sub Distribution Board (LSDB) :Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. "

1

1770

-

... More
Installation, Testing & CommissioningFlameproof 25A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

13

15340

-

... More
Installation, Testing & Commissioning of Flameproof 25A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

47

55460

-

... More
Laying , Testing & Commissioning of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

4900

231280

-

... More
Laying , Testing & Commissioning of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

5640

232932

-

... More
OTHER ACCESSORIES

-

-

-

... More
Laying , Testing & Commissioning of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

5379

-

... More
Laying, Testing & Commissioning of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

6726

-

... More
Laying, Testing & Commissioning of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

5250

1239000

-

... More
150 mm width

200

35400

-

... More
100 mm width

200

23600

-

... More
50 mm width

200

16520

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

180

14868

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

150

26550

-

... More
Fabrication of structural steel work for structural support of junction boxes, Field enclosure and Camera mounted on structures.

42

842520

-

... More
Installation of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

5664

-

... More
Construction, Testing & Commissioningof Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

30

106200

-

... More
Laying, Testing & Commissioning of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

2500

442500

-

... More
Dismantling of existing and re erection on new concrete foundation (M 15) of approx. size 0.6M x 0.6M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II),as per Drawing and as per site condition, all complete as per site direction.

2

9440

-

... More
WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any.

10

5900

-

... More
Dismantling existing camera , encoder, FCU along with power adaptor , shifting and reinstallation on existing/new pole, structure etc including termination of cable for power and signal and fixing power adaptor in New/ existing Field mounted panel.

10

59000

-

... More
underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils : Brick duct for cables, 450mm wide (24 Bricks & 0.0494 cum per Mtr) as per specifications and direction of Engineer in charge.

1000

392440

-

... More
Integration of CCTV System with TAS & Safety PLC System for GUI for monitoring, Alarms & events logging, reporting, trending and archiving and its effects as per logic & its commissioning. Also Auto tracking of PTZ camera to defined Presets based on alarms triggered by TAS.

1

11800

-

... More
Installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment for the LED lights as per site requirements. Cable from the existing panel to lighting distribution panel (LDB).

1

987

-

... More
PART C - COMPREHENSIVE AMC for 7 Years

-

-

-

... More
Comprehensive Annual Maintenance Contract for a period of seven years for entire CCTV System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardware, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, rectification/ replacement of faulty CCTV equipment etc required for running and maintenance of the entire CCTV system to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor.

-

-

-

... More
First Year @ 4% of the basic CAPEX cost

1

2135670

-

... More
Second Year @ 4% of the basic CAPEX cost

1

2135670

-

... More
Third Year @ 7% of the basic CAPEX cost

1

3737423

-

... More
Fourth Year @ 7% of the basic CAPEX cost

1

3737423

-

... More
Fifth Year @ 10% of the basic CAPEX cost

1

5339176

-

... More
Sixth Year @ 6% of the basic CAPEX cost

1

3203505

-

... More
Seventh Year @ 12% of the basic CAPEX cost

1

6407011

-

... More
MYSORE DEPOT

-

-

-

... More
PART-A Supply of Equipments and Accessories

-

-

-

... More
Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

11

1015191

-

... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

438016

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

20

2548800

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

1035096

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

18

1508040

-

... More
Supply of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

20

2229020

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

10

106200

-

... More
Supply of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

10

292746

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

6

203762

-

... More
7 M pole with Accessories as per specification of Tender

7

103596

-

... More
10 M pole with Accessories as per specification of Tender

5

177000

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

12

379204

-

... More
Supply of 20 Meter Tower along with foundation.

7

1239000

-

... More
Supply of rack mounted CCTV Server (s) (N:N) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

1308631

-

... More
Supply of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

3596714

-

... More
Supply of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

540381

-

... More
Supply of minimum 55" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Security Room, TM room) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

2

204140

-

... More
Supply of minimum 75" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Control room ) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

1

294764

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

1062000

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

132144

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

1317824

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

1049728

-

... More
Supply of parallel redundant UPS of minimum capacity of 10 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

561552

-

... More
Supply of UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

17700

-

... More
Supply of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

16262

-

... More
Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

236000

-

... More
Supply of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

3000

194700

-

... More
Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

451468

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

6000

389400

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1080

82836

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

6000

743400

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

1620

764640

-

... More
Flameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

18

70176

-

... More
Supplyof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1000

64900

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Supply of 400 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

18

148680

-

... More
"Lighting Sub Distribution Board (LSDB) :Design ,Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. Vendor to advice to Design as per site location. "

1

59000

-

... More
Flameproof 16A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

6

177000

-

... More
Flameproof 25A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

18

89292

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1100

324500

-

... More
Supply of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

2160

191678

-

... More
OTHER ACCESSORIES

-

-

-

... More
Supply of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

38515

-

... More
Supply of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

44250

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

1890

1115100

-

... More
150 mm width

300

95580

-

... More
100 mm width

200

35400

-

... More
50 mm width

200

25960

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

67

118590

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

472000

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

16.5

1012440

-

... More
Supply of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

14160

-

... More
Supply of Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

332288

-

... More
Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

900

203904

-

... More
As built documentation for entire CCTV System : 3 sets of Hardbound and 5 sets of Soft form on DVDs,

1

23600

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

100

6490

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

100

7174

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

100

12390

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

100

47200

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

100

35872

-

... More
Supply , Design , installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment or supply the Power distribution panel for the LED Lights as per site requirements. Vendor to advice to Design as per site requirements without any price implementation.

1

52864

-

... More
PART-B INSTALLATION, ERECTION, TESTING & COMMISSIONING

-

-

-

... More
Installation, Testing & Commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

11

25960

-

... More
Installation, Testing & Commissioning of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

23600

-

... More
Installation, Testing & Commissioning of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

20

70800

-

... More
Installation, Testing & Commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

11800

-

... More
Installation, Testing & Commissioningof IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

18

42480

-

... More
Installation, Testing & Commissioning of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

20

23600

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

10

23600

-

... More
Installation, Testing & Commissioning of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

10

23600

-

... More
Handling , Installation, Testing & Commissioning of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

6

49560

-

... More
7 M pole with Accessories as per specification of Tender

7

41300

-

... More
10 M pole with Accessories as per specification of Tender

5

29500

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

12

56640

-

... More
20 Meter Tower along with foundation.

7

206500

-

... More
Installation, Testing & Commissioning of rack mounted CCTV Server (s) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

4720

-

... More
Installation, Testing & Commissioning of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

10030

-

... More
Installation, Testing & Commissioning of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

7080

-

... More
Installation, Testing & Commissioning of Ultra High Definition (4K) LED Display for the Monitoring with minimum 55" or more, supporting HDMI2.x resolution for location incharge room and Security room

2

4720

-

... More
Installation, Testing & Commissioningof Full HD LED Display for the Monitoring with minimum 75" or more, supporting HDMI2.x resolution for control room - Terminal

1

2360

-

... More
Installation, Testing & Commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document.

2

10620

-

... More
Installation, Testing & Commissioning of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document.

2

9440

-

... More
Testing & Commissioningof Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

11800

-

... More
Testing & Commissioningof Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Analytics Server with OS, Antivirus etc including analytic license for each camera complete as per specifications and Tender Document

1

59000

-

... More
Installation of of parallel redundant UPS of minimum capacity of 10 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

11800

-

... More
Installation, Testing & Commissioningof UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

2360

-

... More
Installation, Testing & Commissioning of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

2360

-

... More
Laying , Testing & Commissioningof all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

59000

-

... More
Laying, Testing & Commissioning of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

3000

123900

-

... More
Installation, Testing & Commissioningof required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

59000

-

... More
Laying Testing & Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

6000

120360

-

... More
Laying, Testing & Commissioning of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1080

48427

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

6000

247800

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

1620

76464

-

... More
Installation, Testing & CommissioningFlameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

18

21240

-

... More
Installation, Testing & Commissioningof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1000

35400

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Installation, Testing & Commissioning of minimum 400 Watt or as per site requirement whichever is higher LED flood light with suitable current control driver circuit including mounting arrangement complete as per specification and tender document. The required Lux level on either side of the perimeter at a distance of 20m from boundary wall shall be minimum 7 Lux and the light to be fitted on CCTV poles at a height of 8 m across the perimeter.

18

10620

-

... More
Installation, Testing & Commissioning"Lighting Sub Distribution Board (LSDB) :Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. "

1

1770

-

... More
Installation, Testing & CommissioningFlameproof 25A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

6

7080

-

... More
Installation, Testing & Commissioning of Flameproof 25A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

18

21240

-

... More
Laying , Testing & Commissioning of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1100

51920

-

... More
Laying , Testing & Commissioning of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

2160

89208

-

... More
OTHER ACCESSORIES

-

-

-

... More
Laying , Testing & Commissioning of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

5379

-

... More
Laying, Testing & Commissioning of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

6726

-

... More
Laying, Testing & Commissioning of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

1890

446040

-

... More
150 mm width

300

53100

-

... More
100 mm width

200

23600

-

... More
50 mm width

200

16520

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

67

5534

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

17700

-

... More
Fabrication of structural steel work for structural support of junction boxes, Field enclosure and Camera mounted on structures.

16.5

330990

-

... More
Installation of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

5664

-

... More
Construction, Testing & Commissioningof Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

70800

-

... More
Laying, Testing & Commissioning of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

900

159300

-

... More
Dismantling of existing and re erection on new concrete foundation (M 15) of approx. size 0.6M x 0.6M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II),as per Drawing and as per site condition, all complete as per site direction.

10

47200

-

... More
WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any.

20

11800

-

... More
Dismantling existing camera , encoder, FCU along with power adaptor , shifting and reinstallation on existing/new pole, structure etc including termination of cable for power and signal and fixing power adaptor in New/ existing Field mounted panel.

10

59000

-

... More
underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils : Brick duct for cables, 450mm wide (24 Bricks & 0.0494 cum per Mtr) as per specifications and direction of Engineer in charge.

1000

392440

-

... More
Integration of CCTV System with TAS & Safety PLC System for GUI for monitoring, Alarms & events logging, reporting, trending and archiving and its effects as per logic & its commissioning. Also Auto tracking of PTZ camera to defined Presets based on alarms triggered by TAS.

1

11800

-

... More
Installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment for the LED lights as per site requirements. Cable from the existing panel to lighting distribution panel (LDB).

1

987

-

... More
PART C - COMPREHENSIVE AMC for 7 Years

-

-

-

... More
Comprehensive Annual Maintenance Contract for a period of seven years for entire CCTV System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardware, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, rectification/ replacement of faulty CCTV equipment etc required for running and maintenance of the entire CCTV system to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor.

-

-

-

... More
First Year @ 4% of the basic CAPEX cost

1

1298488

-

... More
Second Year @ 4% of the basic CAPEX cost

1

1298488

-

... More
Third Year @ 7% of the basic CAPEX cost

1

2272354

-

... More
Fourth Year @ 7% of the basic CAPEX cost

1

2272354

-

... More
Fifth Year @ 10% of the basic CAPEX cost

1

3246220

-

... More
Sixth Year @ 6% of the basic CAPEX cost

1

1947732

-

... More
Seventh Year @ 12% of the basic CAPEX cost

1

3895464

-

... More
BELGAUM DEPOT

-

-

-

... More
PART-A Supply of Equipments and Accessories

-

-

-

... More
Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

12

1107481

-

... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

438016

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

20

2548800

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

1035096

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

28

2345840

-

... More
Supply of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

24

2674824

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

12

127440

-

... More
Supply of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

12

351295

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

6

203762

-

... More
7 M pole with Accessories as per specification of Tender

6

88797

-

... More
10 M pole with Accessories as per specification of Tender

8

283200

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

22

695208

-

... More
Supply of 15 Meter pole along with foundation.

5

885000

-

... More
Supply of 20 Meter Tower along with foundation.

2

413000

-

... More
Supply of rack mounted CCTV Server (s) (N:N) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

1308631

-

... More
Supply of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

4256111

-

... More
Supply of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

540381

-

... More
Supply of minimum 55" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Security Room, TM room) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

2

204140

-

... More
Supply of minimum 75" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Control room ) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

1

294764

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

1062000

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

132143

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

1317824

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

1049728

-

... More
Supply of parallel redundant UPS of minimum capacity of 10 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

561552

-

... More
Supply of UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

17700

-

... More
Supply of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

16262

-

... More
Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

236000

-

... More
Supply of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

4450

288805

-

... More
Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

451468

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

7100

460790

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1612

123640

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

7100

879690

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

2400

1132800

-

... More
Flameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

22

85771

-

... More
Supplyof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1500

97350

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Supply of 400 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

28

231280

-

... More
"Lighting Sub Distribution Board (LSDB) :Design ,Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. Vendor to advice to Design as per site location. "

1

59000

-

... More
Flameproof 16A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

8

236000

-

... More
Flameproof 25A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

28

138900

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1650

486750

-

... More
Supply of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3360

297360

-

... More
OTHER ACCESSORIES

-

-

-

... More
Supply of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

38515

-

... More
Supply of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

44250

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

2822

1664980

-

... More
150 mm width

300

95580

-

... More
100 mm width

200

35400

-

... More
50 mm width

200

25960

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

98

173460

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

472000

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

22

1349920

-

... More
Supply of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

14160

-

... More
Supply of Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

332288

-

... More
Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1344

304496

-

... More
As built documentation for entire CCTV System : 3 sets of Hardbound and 5 sets of Soft form on DVDs,

1

23600

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

100

6490

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

100

7080

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

100

12390

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

100

47200

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

100

35872

-

... More
Supply , Design , installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment or supply the Power distribution panel for the LED Lights as per site requirements. Vendor to advice to Design as per site requirements without any price implementation.

1

52864

-

... More
PART-B INSTALLATION, ERECTION, TESTING & COMMISSIONING

-

-

-

... More
Installation, Testing & Commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

12

28320

-

... More
Installation, Testing & Commissioning of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

23600

-

... More
Installation, Testing & Commissioning of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

20

59000

-

... More
Installation, Testing & Commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

11800

-

... More
Installation, Testing & Commissioningof IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

28

66080

-

... More
Installation, Testing & Commissioning of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

24

28320

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

12

28320

-

... More
Installation, Testing & Commissioning of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

12

28320

-

... More
Handling , Installation, Testing & Commissioning of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

6

49560

-

... More
7 M pole with Accessories as per specification of Tender

5

23600

-

... More
10 M pole with Accessories as per specification of Tender

6

35400

-

... More
10 M pole with Accessories as per specification of Tender

8

47200

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

22

103840

-

... More
20 Meter Tower along with foundation.

2

82600

-

... More
Installation, Testing & Commissioning of rack mounted CCTV Server (s) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

4720

-

... More
Installation, Testing & Commissioning of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

10030

-

... More
Installation, Testing & Commissioning of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

7080

-

... More
Installation, Testing & Commissioning of Ultra High Definition (4K) LED Display for the Monitoring with minimum 55" or more, supporting HDMI2.x resolution for location incharge room and Security room

2

4720

-

... More
Installation, Testing & Commissioningof Full HD LED Display for the Monitoring with minimum 75" or more, supporting HDMI2.x resolution for control room - Terminal

1

2360

-

... More
Installation, Testing & Commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document.

2

10620

-

... More
Installation, Testing & Commissioning of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document.

2

9440

-

... More
Testing & Commissioningof Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

11800

-

... More
Testing & Commissioningof Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Analytics Server with OS, Antivirus etc including analytic license for each camera complete as per specifications and Tender Document

1

59000

-

... More
Installation of of parallel redundant UPS of minimum capacity of 10 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

11800

-

... More
Installation, Testing & Commissioningof UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

2360

-

... More
Installation, Testing & Commissioning of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

2360

-

... More
Laying , Testing & Commissioningof all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

59000

-

... More
Laying, Testing & Commissioning of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

4450

183785

-

... More
Installation, Testing & Commissioningof required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

59000

-

... More
Laying Testing & Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

7100

142426

-

... More
Laying, Testing & Commissioning of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1612

72282

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

7100

293230

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

2400

113280

-

... More
Installation, Testing & CommissioningFlameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

22

25960

-

... More
Installation, Testing & Commissioningof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1500

53100

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Installation, Testing & Commissioning of minimum 400 Watt or as per site requirement whichever is higher LED flood light with suitable current control driver circuit including mounting arrangement complete as per specification and tender document. The required Lux level on either side of the perimeter at a distance of 20m from boundary wall shall be minimum 7 Lux and the light to be fitted on CCTV poles at a height of 8 m across the perimeter.

28

16520

-

... More
Installation, Testing & Commissioning"Lighting Sub Distribution Board (LSDB) :Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. "

1

1770

-

... More
Installation, Testing & CommissioningFlameproof 25A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

8

9440

-

... More
Installation, Testing & Commissioning of Flameproof 25A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

28

33040

-

... More
Laying , Testing & Commissioning of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1650

77880

-

... More
Laying , Testing & Commissioning of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3360

138768

-

... More
OTHER ACCESSORIES

-

-

-

... More
Laying , Testing & Commissioning of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

5379

-

... More
Laying, Testing & Commissioning of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

6726

-

... More
Laying, Testing & Commissioning of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

2822

665992

-

... More
150 mm width

300

53100

-

... More
100 mm width

200

23600

-

... More
50 mm width

200

16520

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

98

8094

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

17700

-

... More
Fabrication of structural steel work for structural support of junction boxes, Field enclosure and Camera mounted on structures.

22

441320

-

... More
Installation of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

5664

-

... More
Construction, Testing & Commissioningof Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

70800

-

... More
Laying, Testing & Commissioning of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1344

237888

-

... More
Dismantling of existing and re erection on new concrete foundation (M 15) of approx. size 0.6M x 0.6M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II),as per Drawing and as per site condition, all complete as per site direction.

3

14160

-

... More
WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any.

10

5900

-

... More
Dismantling existing camera , encoder, FCU along with power adaptor , shifting and reinstallation on existing/new pole, structure etc including termination of cable for power and signal and fixing power adaptor in New/ existing Field mounted panel.

10

59000

-

... More
underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils : Brick duct for cables, 450mm wide (24 Bricks & 0.0494 cum per Mtr) as per specifications and direction of Engineer in charge.

1000

392440

-

... More
Integration of CCTV System with TAS & Safety PLC System for GUI for monitoring, Alarms & events logging, reporting, trending and archiving and its effects as per logic & its commissioning. Also Auto tracking of PTZ camera to defined Presets based on alarms triggered by TAS.

1

11800

-

... More
Installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment for the LED lights as per site requirements. Cable from the existing panel to lighting distribution panel (LDB).

1

987

-

... More
PART C - COMPREHENSIVE AMC for 7 Years

-

-

-

... More
Comprehensive Annual Maintenance Contract for a period of seven years for entire CCTV System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardware, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, rectification/ replacement of faulty CCTV equipment etc required for running and maintenance of the entire CCTV system to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor.

-

-

-

... More
First Year @ 4% of the basic CAPEX cost

1

1518796

-

... More
Second Year @ 4% of the basic CAPEX cost

1

1518796

-

... More
Third Year @ 7% of the basic CAPEX cost

1

2657894

-

... More
Fourth Year @ 7% of the basic CAPEX cost

1

2657894

-

... More
Fifth Year @ 10% of the basic CAPEX cost

1

3796992

-

... More
Sixth Year @ 6% of the basic CAPEX cost

1

2278195

-

... More
Seventh Year @ 12% of the basic CAPEX cost

1

4556390

-

... More
MANGALORE TERMINAL

-

-

-

... More
PART-A Supply of Equipments and Accessories

-

-

-

... More
Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

6

553740

-

... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

12

525619

-

... More
Integral Explosion Proof HD IP PTZ Cameras (2MP) including power supply unit / POE, surge protection unit and mounting accessories.

5

3363000

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

35

4460400

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

9

2328966

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

31

2597180

-

... More
Supply of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

32

3566432

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

15

159300

-

... More
Supply of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

17

497668

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

10

339604

-

... More
15 M pole with Accessories as per specification of Tender

12

510468

-

... More
7 M pole with Accessories as per specification of Tender

4

59198

-

... More
10 M pole with Accessories as per specification of Tender

5

177000

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

16

505606

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m and LED flood light at 15 m of the pole across perimeter as per tender

4

195880

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m, 2 PTZ camera at 15 m and LED flood light at 14 m of the pole across perimeter as per tender

2

93220

-

... More
Supply of 20 Meter Tower along with foundation.

2

413000

-

... More
Supply of rack mounted CCTV Server (s) (N:N) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

1308631

-

... More
Supply of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

5754742

-

... More
Supply of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

540381

-

... More
Supply of minimum 55" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Security Room, TM room) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

2

204140

-

... More
Supply of minimum 75" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Control room ) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

1

294764

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

1062000

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

132143

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

1317824

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

1049728

-

... More
Supply of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

808300

-

... More
Supply of UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

17700

-

... More
Supply of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

16262

-

... More
Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

236000

-

... More
Supply of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

5088

330211

-

... More
Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

451468

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

9600

623040

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1850

141895

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

9600

1189440

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

2775

1309800

-

... More
Flameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

29

113062

-

... More
Supplyof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1542

100075

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Supply of 400 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

31

256060

-

... More
"Lighting Sub Distribution Board (LSDB) :Design ,Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. Vendor to advice to Design as per site location. "

1

59000

-

... More
Flameproof 25A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

9

265500

-

... More
Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

31

153782

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1850

545750

-

... More
Supply of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3720

330112

-

... More
OTHER ACCESSORIES

-

-

-

... More
Supply of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

38515

-

... More
Supply of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

44250

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

3238

1910420

-

... More
150 mm width

300

95580

-

... More
100 mm width

200

35400

-

... More
50 mm width

200

25960

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

113

200010

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

472000

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

26

1595360

-

... More
Supply of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

14160

-

... More
Supply of Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

332288

-

... More
Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1542

349355

-

... More
As built documentation for entire CCTV System : 3 sets of Hardbound and 5 sets of Soft form on DVDs,

1

23600

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

100

6490

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

100

7174

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

100

12390

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

100

47200

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

100

35872

-

... More
Supply , Design , installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment or supply the Power distribution panel for the LED Lights as per site requirements. Vendor to advice to Design as per site requirements without any price implementation.

1

52864

-

... More
PART-B INSTALLATION, ERECTION, TESTING & COMMISSIONING

-

-

-

... More
Installation, Testing & Commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

6

14160

-

... More
Installation, Testing & Commissioning of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

12

28320

-

... More
Integral Explosion Proof HD IP PTZ Cameras (2MP) including power supply unit / POE, surge protection unit and mounting accessories.

5

17700

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

35

103250

-

... More
Installation, Testing & Commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

9

26550

-

... More
Installation, Testing & Commissioningof IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

31

73160

-

... More
Installation, Testing & Commissioning of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

32

37760

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

15

35400

-

... More
Installation, Testing & Commissioning of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

17

40120

-

... More
Handling, Installation, Testing & Commissioning of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

10

82600

-

... More
15 M pole with Accessories as per specification of Tender

12

70800

-

... More
7 M pole with Accessories as per specification of Tender

4

23600

-

... More
10 M pole with Accessories as per specification of Tender

5

29500

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

16

75520

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m and LED flood light at 15 m of the pole across perimeter as per tender

4

44840

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m, 2 PTZ camera at 15 m and LED flood light at 14 m of the pole across perimeter as per tender

2

22420

-

... More
20 Meter Tower along with foundation.

2

82600

-

... More
Installation, Testing & Commissioning of rack mounted CCTV Server (s) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

4720

-

... More
Installation, Testing & Commissioning of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

10030

-

... More
Installation, Testing & Commissioning of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

7080

-

... More
Installation, Testing & Commissioning of Ultra High Definition (4K) LED Display for the Monitoring with minimum 46" or more, supporting HDMI2.x resolution for location incharge room and Security room

2

4720

-

... More
Installation, Testing & Commissioningof Full HD LED Display for the Monitoring with minimum 75" or more, supporting HDMI2.x resolution for control room - Terminal

1

2360

-

... More
Installation, Testing & Commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document.

2

10620

-

... More
Installation, Testing & Commissioning of Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

9440

-

... More
Testing & Commissioningof Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 100 cameras recording, 100 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

11800

-

... More
Testing & Commissioningof Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Analytics Server with OS, Antivirus etc including analytic license for each camera complete as per specifications and Tender Document

1

59000

-

... More
Installation of of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

11800

-

... More
Installation, Testing & Commissioningof UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

2360

-

... More
Installation, Testing & Commissioning of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

2360

-

... More
Laying , Testing & Commissioningof all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

59000

-

... More
Laying, Testing & Commissioning of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

5088

210134

-

... More
Installation, Testing & Commissioningof required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

59000

-

... More
Laying Testing & Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

9600

192576

-

... More
Laying, Testing & Commissioning of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1850

82954

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

9600

396480

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

2775

130980

-

... More
Installation, Testing & CommissioningFlameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

29

34220

-

... More
Installation, Testing & Commissioningof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1542

54586

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Installation, Testing & Commissioning of minimum 400 Watt or as per site requirement whichever is higher LED flood light with suitable current control driver circuit including mounting arrangement complete as per specification and tender document. The required Lux level on either side of the perimeter at a distance of 20m from boundary wall shall be minimum 7 Lux and the light to be fitted on CCTV poles at a height of 8 m across the perimeter.

31

18290

-

... More
Installation, Testing & Commissioning"Lighting Sub Distribution Board (LSDB) :Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. "

1

1770

-

... More
Installation, Testing & CommissioningFlameproof 16A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

9

10620

-

... More
Installation, Testing & Commissioning of Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

31

36580

-

... More
Laying , Testing & Commissioning of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1850

87320

-

... More
Laying , Testing & Commissioning of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3720

153636

-

... More
OTHER ACCESSORIES

-

-

-

... More
Laying , Testing & Commissioning of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

5379

-

... More
Laying, Testing & Commissioning of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

6726

-

... More
Laying,, Testing & Commissioning of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

3238

764168

-

... More
150 mm width

300

53100

-

... More
100 mm width

200

23600

-

... More
50 mm width

200

16520

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

113

9333

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

17700

-

... More
Fabrication of structural steel work for structural support of junction boxes, Field enclosure and Camera mounted on structures.

26

521560

-

... More
Installation of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

5664

-

... More
Construction, Testing & Commissioningof Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

70800

-

... More
Laying, Testing & Commissioning of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1542

272934

-

... More
Dismantling of existing and re erection on new concrete foundation (M 15) of approx. size 0.6M x 0.6M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II),as per Drawing and as per site condition, all complete as per site direction.

4

18880

-

... More
WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any.

10

5900

-

... More
Dismantling existing camera , encoder, FCU along with power adaptor , shifting and reinstallation on existing/new pole, structure etc including termination of cable for power and signal and fixing power adaptor in New/ existing Field mounted panel.

10

59000

-

... More
underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils : Brick duct for cables, 450mm wide (24 Bricks & 0.0494 cum per Mtr) as per specifications and direction of Engineer in charge.

1000

392440

-

... More
Integration of CCTV System with TAS & Safety PLC System for GUI for monitoring, Alarms & events logging, reporting, trending and archiving and its effects as per logic & its commissioning. Also Auto tracking of PTZ camera to defined Presets based on alarms triggered by TAS.

1

11800

-

... More
Installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment for the LED lights as per site requirements. Cable from the existing panel to lighting distribution panel (LDB).

1

987

-

... More
PART C - COMPREHENSIVE AMC for 7 Years

-

-

-

... More
Comprehensive Annual Maintenance Contract for a period of seven years for entire CCTV System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardware, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, rectification/ replacement of faulty CCTV equipment etc required for running and maintenance of the entire CCTV system to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor.

-

-

-

... More
First Year @ 4% of the basic CAPEX cost

1

1959448

-

... More
Second Year @ 4% of the basic CAPEX cost

1

1959448

-

... More
Third Year @ 7% of the basic CAPEX cost

1

3429034

-

... More
Fourth Year @ 7% of the basic CAPEX cost

1

3429034

-

... More
Fifth Year @ 10% of the basic CAPEX cost

1

4898620

-

... More
Sixth Year @ 6% of the basic CAPEX cost

1

2939172

-

... More
Seventh Year @ 12% of the basic CAPEX cost

1

5878345

-

... More
HUBLI DEPOT

-

-

-

... More
PART-A Supply of Equipments and Accessories

-

-

-

... More
Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

13

1199772

-

... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

438016

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

28

3568320

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

6

1552644

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

33

2764740

-

... More
Supply of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

30

3343530

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

15

159300

-

... More
Supply of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

15

439119

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

7

237722

-

... More
15 M pole with Accessories as per specification of Tender

6

255234

-

... More
7 M pole with Accessories as per specification of Tender

7

103596

-

... More
10 M pole with Accessories as per specification of Tender

10

354000

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

21

663608

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m and LED flood light at 15 m of the pole across perimeter as per tender

3

146910

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m, 2 PTZ camera at 15 m and LED flood light at 14 m of the pole across perimeter as per tender

2

93220

-

... More
Supply of 20 Meter Tower along with foundation.

2

413000

-

... More
Supply of rack mounted CCTV Server (s) (N:N) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

1308631

-

... More
Supply of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

5215235

-

... More
Supply of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

540381

-

... More
Supply of minimum 55" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Security Room, TM room) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

2

204140

-

... More
Supply of minimum 75" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Control room ) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

1

294764

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

1062000

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

132143

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

1317824

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

1049728

-

... More
Supply of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

561552

-

... More
Supply of UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

17700

-

... More
Supply of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

16262

-

... More
Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

236000

-

... More
Supply of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

5940

385506

-

... More
Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

451468

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

8700

564630

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

2160

165672

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

8700

1077930

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

3240

1529280

-

... More
Flameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

25

97468

-

... More
Supplyof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1800

116820

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Supply of 400 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

33

272580

-

... More
"Lighting Sub Distribution Board (LSDB) :Design ,Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. Vendor to advice to Design as per site location. "

1

59000

-

... More
Flameproof 25A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

10

295000

-

... More
Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

33

163703

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

2400

708000

-

... More
Supply of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3960

350460

-

... More
OTHER ACCESSORIES

-

-

-

... More
Supply of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

150

48144

-

... More
Supply of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

200

59000

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

3780

2230200

-

... More
150 mm width

400

127440

-

... More
100 mm width

200

35400

-

... More
50 mm width

200

25960

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

131

231870

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

472000

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

30

1840800

-

... More
Supply of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

14160

-

... More
Supply of Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

332288

-

... More
Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1800

407808

-

... More
As built documentation for entire CCTV System : 3 sets of Hardbound and 5 sets of Soft form on DVDs,

1

23600

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

100

6490

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

100

7080

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

100

12390

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

100

47200

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

100

35872

-

... More
Supply , Design , installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment or supply the Power distribution panel for the LED Lights as per site requirements. Vendor to advice to Design as per site requirements without any price implementation.

1

52864

-

... More
PART-B INSTALLATION, ERECTION, TESTING & COMMISSIONING

-

-

-

... More
Installation, Testing & Commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

13

30680

-

... More
Installation, Testing & Commissioning of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

23600

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

28

82600

-

... More
Installation, Testing & Commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

6

17700

-

... More
Installation, Testing & Commissioningof IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

33

77880

-

... More
Installation, Testing & Commissioning of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

30

35400

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

15

35400

-

... More
Installation, Testing & Commissioning of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

15

35400

-

... More
Handling, Installation, Testing & Commissioning of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

7

57820

-

... More
15 M pole with Accessories as per specification of Tender

6

35400

-

... More
7 M pole with Accessories as per specification of Tender

7

41300

-

... More
10 M pole with Accessories as per specification of Tender

10

59000

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

21

99120

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m and LED flood light at 15 m of the pole across perimeter as per tender

3

33630

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m, 2 PTZ camera at 15 m and LED flood light at 14 m of the pole across perimeter as per tender

2

22420

-

... More
20 Meter Tower along with foundation.

2

82600

-

... More
Installation, Testing & Commissioning of rack mounted CCTV Server (s) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

4720

-

... More
Installation, Testing & Commissioning of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

10030

-

... More
Installation, Testing & Commissioning of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

7080

-

... More
Installation, Testing & Commissioning of Ultra High Definition (4K) LED Display for the Monitoring with minimum 46" or more, supporting HDMI2.x resolution for location incharge room and Security room

2

4720

-

... More
Installation, Testing & Commissioningof Full HD LED Display for the Monitoring with minimum 75" or more, supporting HDMI2.x resolution for control room - Terminal

1

2360

-

... More
Installation, Testing & Commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document.

2

10620

-

... More
Installation, Testing & Commissioning of Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

9440

-

... More
Testing & Commissioningof Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 100 cameras recording, 100 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

11800

-

... More
Testing & Commissioningof Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Analytics Server with OS, Antivirus etc including analytic license for each camera complete as per specifications and Tender Document

1

59000

-

... More
Installation of of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

11800

-

... More
Installation, Testing & Commissioningof UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

2360

-

... More
Installation, Testing & Commissioning of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

2360

-

... More
Laying , Testing & Commissioningof all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

59000

-

... More
Laying, Testing & Commissioning of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

5940

245322

-

... More
Installation, Testing & Commissioningof required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

59000

-

... More
Laying Testing & Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

8700

174522

-

... More
Laying, Testing & Commissioning of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

2160

96854

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

8700

359310

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

3240

152928

-

... More
Installation, Testing & CommissioningFlameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

25

29500

-

... More
Installation, Testing & Commissioningof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1800

63720

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Installation, Testing & Commissioning of minimum 400 Watt or as per site requirement whichever is higher LED flood light with suitable current control driver circuit including mounting arrangement complete as per specification and tender document. The required Lux level on either side of the perimeter at a distance of 20m from boundary wall shall be minimum 7 Lux and the light to be fitted on CCTV poles at a height of 8 m across the perimeter.

33

19470

-

... More
Installation, Testing & Commissioning"Lighting Sub Distribution Board (LSDB) :Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. "

1

1770

-

... More
Installation, Testing & CommissioningFlameproof 16A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

10

11800

-

... More
Installation, Testing & Commissioning of Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

33

38940

-

... More
Laying , Testing & Commissioning of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

2400

113280

-

... More
Laying , Testing & Commissioning of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3960

163548

-

... More
OTHER ACCESSORIES

-

-

-

... More
Laying , Testing & Commissioning of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

150

6724

-

... More
Laying, Testing & Commissioning of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

200

8968

-

... More
Laying,, Testing & Commissioning of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

3780

892080

-

... More
150 mm width

400

70800

-

... More
100 mm width

200

23600

-

... More
50 mm width

200

16520

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

131

10820

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

17700

-

... More
Fabrication of structural steel work for structural support of junction boxes, Field enclosure and Camera mounted on structures.

30

601800

-

... More
Installation of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

5664

-

... More
Construction, Testing & Commissioningof Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

70800

-

... More
Laying, Testing & Commissioning of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1800

318600

-

... More
Dismantling of existing and re erection on new concrete foundation (M 15) of approx. size 0.6M x 0.6M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II),as per Drawing and as per site condition, all complete as per site direction.

5

23600

-

... More
WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any.

10

5900

-

... More
Dismantling existing camera , encoder, FCU along with power adaptor , shifting and reinstallation on existing/new pole, structure etc including termination of cable for power and signal and fixing power adaptor in New/ existing Field mounted panel.

10

59000

-

... More
underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils : Brick duct for cables, 450mm wide (24 Bricks & 0.0494 cum per Mtr) as per specifications and direction of Engineer in charge.

1000

392440

-

... More
Integration of CCTV System with TAS & Safety PLC System for GUI for monitoring, Alarms & events logging, reporting, trending and archiving and its effects as per logic & its commissioning. Also Auto tracking of PTZ camera to defined Presets based on alarms triggered by TAS.

1

11800

-

... More
Installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment for the LED lights as per site requirements. Cable from the existing panel to lighting distribution panel (LDB).

1

987

-

... More
PART C - COMPREHENSIVE AMC for 7 Years

-

-

-

... More
Comprehensive Annual Maintenance Contract for a period of seven years for entire CCTV System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardware, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, rectification/ replacement of faulty CCTV equipment etc required for running and maintenance of the entire CCTV system to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor.

-

-

-

... More
First Year @ 4% of the basic CAPEX cost

1

1798807

-

... More
Second Year @ 4% of the basic CAPEX cost

1

1798807

-

... More
Third Year @ 7% of the basic CAPEX cost

1

3147913

-

... More
Fourth Year @ 7% of the basic CAPEX cost

1

3147913

-

... More
Fifth Year @ 10% of the basic CAPEX cost

1

4497019

-

... More
Sixth Year @ 6% of the basic CAPEX cost

1

2698211

-

... More
Seventh Year @ 12% of the basic CAPEX cost

1

5396423

-

... More
BIJAPUR DEPOT

-

-

-

... More
PART-A Supply of Equipments and Accessories

-

-

-

... More
Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

13

1199772

-

... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

438016

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

24

3058560

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

1035096

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

26

2178280

-

... More
Supply of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

25

2786275

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

10

106200

-

... More
Supply of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

15

439119

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

7

237722

-

... More
15 M pole with Accessories as per specification of Tender

5

212695

-

... More
7 M pole with Accessories as per specification of Tender

6

88797

-

... More
10 M pole with Accessories as per specification of Tender

7

247800

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

13

410805

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m and LED flood light at 15 m of the pole across perimeter as per tender

5

244850

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m, 2 PTZ camera at 15 m and LED flood light at 14 m of the pole across perimeter as per tender

1

46610

-

... More
Supply of 20 Meter Tower along with foundation.

2

413000

-

... More
Supply of rack mounted CCTV Server (s) (N:N) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

1308631

-

... More
Supply of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

4435946

-

... More
Supply of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

540381

-

... More
Supply of minimum 55" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Security Room, TM room) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

2

204140

-

... More
Supply of minimum 75" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Control room ) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

1

294764

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

1062000

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

132143

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

1317824

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

1049728

-

... More
Supply of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

561552

-

... More
Supply of UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

17700

-

... More
Supply of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

16262

-

... More
Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

236000

-

... More
Supply of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

4785

310546

-

... More
Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

451468

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

7200

467280

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1740

133458

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

7200

892080

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

2610

1231920

-

... More
Flameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

23

89670

-

... More
Supplyof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1450

94105

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Supply of 400 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

26

214760

-

... More
"Lighting Sub Distribution Board (LSDB) :Design ,Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. Vendor to advice to Design as per site location. "

1

59000

-

... More
Flameproof 25A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

8

236000

-

... More
Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

26

128978

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1740

513300

-

... More
Supply of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3120

276120

-

... More
OTHER ACCESSORIES

-

-

-

... More
Supply of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

38515

-

... More
Supply of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

44250

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

3045

1796550

-

... More
150 mm width

350

111510

-

... More
100 mm width

200

35400

-

... More
50 mm width

200

25960

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

105

185850

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

472000

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

24.5

15033200

-

... More
Supply of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

14160

-

... More
Supply of Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

332288

-

... More
Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1450

328512

-

... More
As built documentation for entire CCTV System : 3 sets of Hardbound and 5 sets of Soft form on DVDs,

1

23600

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

100

6490

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

100

7080

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

100

12390

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

100

47200

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

100

35872

-

... More
Supply , Design , installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment or supply the Power distribution panel for the LED Lights as per site requirements. Vendor to advice to Design as per site requirements without any price implementation.

1

52864

-

... More
PART-B INSTALLATION, ERECTION, TESTING & COMMISSIONING

-

-

-

... More
Installation, Testing & Commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

13

30680

-

... More
Installation, Testing & Commissioning of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

10

23600

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

24

70800

-

... More
Installation, Testing & Commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

4

11800

-

... More
Installation, Testing & Commissioningof IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

26

61360

-

... More
Installation, Testing & Commissioning of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

25

29500

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

10

23600

-

... More
Installation, Testing & Commissioning of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

15

35400

-

... More
Handling, Installation, Testing & Commissioning of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

7

57820

-

... More
15 M pole with Accessories as per specification of Tender

5

29500

-

... More
7 M pole with Accessories as per specification of Tender

6

35400

-

... More
10 M pole with Accessories as per specification of Tender

7

41300

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

13

61360

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m and LED flood light at 15 m of the pole across perimeter as per tender

5

56050

-

... More
15 M pole with cantilever arrangement for mounting of 1 fixed camera at 12 m, 2 PTZ camera at 15 m and LED flood light at 14 m of the pole across perimeter as per tender

1

11210

-

... More
20 Meter Tower along with foundation.

2

82600

-

... More
Installation, Testing & Commissioning of rack mounted CCTV Server (s) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

4720

-

... More
Installation, Testing & Commissioning of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

10030

-

... More
Installation, Testing & Commissioning of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

7080

-

... More
Installation, Testing & Commissioning of Ultra High Definition (4K) LED Display for the Monitoring with minimum 46" or more, supporting HDMI2.x resolution for location incharge room and Security room

2

4720

-

... More
Installation, Testing & Commissioningof Full HD LED Display for the Monitoring with minimum 75" or more, supporting HDMI2.x resolution for control room - Terminal

1

2360

-

... More
Installation, Testing & Commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document.

2

10620

-

... More
Installation, Testing & Commissioning of Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

9440

-

... More
Testing & Commissioningof Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 100 cameras recording, 100 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

11800

-

... More
Testing & Commissioningof Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Analytics Server with OS, Antivirus etc including analytic license for each camera complete as per specifications and Tender Document

1

59000

-

... More
Installation of of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

11800

-

... More
Installation, Testing & Commissioningof UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

2360

-

... More
Installation, Testing & Commissioning of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

2360

-

... More
Laying , Testing & Commissioningof all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

59000

-

... More
Laying, Testing & Commissioning of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

4785

197620

-

... More
Installation, Testing & Commissioningof required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

590000

-

... More
Laying Testing & Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

7200

144432

-

... More
Laying, Testing & Commissioning of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

1740

78021

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

7200

297360

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

2610

123192

-

... More
Installation, Testing & CommissioningFlameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

23

27140

-

... More
Installation, Testing & Commissioningof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

1450

51330

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Installation, Testing & Commissioning of minimum 400 Watt or as per site requirement whichever is higher LED flood light with suitable current control driver circuit including mounting arrangement complete as per specification and tender document. The required Lux level on either side of the perimeter at a distance of 20m from boundary wall shall be minimum 7 Lux and the light to be fitted on CCTV poles at a height of 8 m across the perimeter.

26

15340

-

... More
Installation, Testing & Commissioning"Lighting Sub Distribution Board (LSDB) :Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. "

1

1770

-

... More
Installation, Testing & CommissioningFlameproof 16A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

8

9440

-

... More
Installation, Testing & Commissioning of Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

26

30680

-

... More
Laying , Testing & Commissioning of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

1740

82128

-

... More
Laying , Testing & Commissioning of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

3120

128856

-

... More
OTHER ACCESSORIES

-

-

-

... More
Laying , Testing & Commissioning of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

120

5379

-

... More
Laying, Testing & Commissioning of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

150

6726

-

... More
Laying,, Testing & Commissioning of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

3045

718620

-

... More
150 mm width

350

61950

-

... More
100 mm width

200

23600

-

... More
50 mm width

200

16520

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

105

8673

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

100

17700

-

... More
Fabrication of structural steel work for structural support of junction boxes, Field enclosure and Camera mounted on structures.

24.5

491470

-

... More
Installation of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

40

5664

-

... More
Construction, Testing & Commissioningof Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

20

70800

-

... More
Laying, Testing & Commissioning of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

1450

256650

-

... More
Dismantling of existing and re erection on new concrete foundation (M 15) of approx. size 0.6M x 0.6M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II),as per Drawing and as per site condition, all complete as per site direction.

5

23600

-

... More
WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any.

10

5900

-

... More
Dismantling existing camera , encoder, FCU along with power adaptor , shifting and reinstallation on existing/new pole, structure etc including termination of cable for power and signal and fixing power adaptor in New/ existing Field mounted panel.

10

59000

-

... More
underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils : Brick duct for cables, 450mm wide (24 Bricks & 0.0494 cum per Mtr) as per specifications and direction of Engineer in charge.

1000

392440

-

... More
Integration of CCTV System with TAS & Safety PLC System for GUI for monitoring, Alarms & events logging, reporting, trending and archiving and its effects as per logic & its commissioning. Also Auto tracking of PTZ camera to defined Presets based on alarms triggered by TAS.

1

11800

-

... More
Installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment for the LED lights as per site requirements. Cable from the existing panel to lighting distribution panel (LDB).

1

987

-

... More
PART C - COMPREHENSIVE AMC for 7 Years

-

-

-

... More
Comprehensive Annual Maintenance Contract for a period of seven years for entire CCTV System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardware, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, rectification/ replacement of faulty CCTV equipment etc required for running and maintenance of the entire CCTV system to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor.

-

-

-

... More
First Year @ 4% of the basic CAPEX cost

1

2113404

-

... More
Second Year @ 4% of the basic CAPEX cost

1

2113404

-

... More
Third Year @ 7% of the basic CAPEX cost

1

3698458

-

... More
Fourth Year @ 7% of the basic CAPEX cost

1

3698458

-

... More
Fifth Year @ 10% of the basic CAPEX cost

1

5283511

-

... More
Sixth Year @ 6% of the basic CAPEX cost

1

3170107

-

... More
Seventh Year @ 12% of the basic CAPEX cost

1

6340214

-

... More
DEVANGONTI TERMINAL

-

-

-

... More
PART-A Supply of Equipments and Accessories

-

-

-

... More
Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

12

1107481

-

... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

15

657024

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

41

5225040

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

13

3364062

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

63

5278140

-

... More
Supply of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

45

5015295

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

23

244260

-

... More
Supply of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

22

644041

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

11

373564

-

... More
15 M pole with Accessories as per specification of Tender

14

595546

-

... More
7 M pole with Accessories as per specification of Tender

8

118396

-

... More
10 M pole with Accessories as per specification of Tender

10

354000

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

30

948012

-

... More
Supply of 20 Meter Tower along with foundation.

2

413000

-

... More
Supply of rack mounted CCTV Server (s) (N:N) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

1308631

-

... More
Supply of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

8452277

-

... More
Supply of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

540381

-

... More
Supply of minimum 55" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Security Room, TM room) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

2

204140

-

... More
Supply of minimum 75" Ultra High Definition (4K) LED Display monitor along with mounting accessories etc complete as per specifications and Tender Document for repeat display of CCTV output. (Location : Control room ) Note: Number of LED TV monitor to be provided as per viewing window size requirement.

1

294764

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

1062000

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

132143

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

588744

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

702013

-

... More
Supply of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

808300

-

... More
Supply of UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

17700

-

... More
Supply of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

16262

-

... More
Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

236000

-

... More
Supply of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

11830

767767

-

... More
Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

451468

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

14800

960520

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

4302

329963

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

13700

1697430

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

6453

3045816

-

... More
Flameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

47

183239

-

... More
Supplyof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

2500

162250

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Supply of 400 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

63

520380

-

... More
"Lighting Sub Distribution Board (LSDB) :Design ,Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. Vendor to advice to Design as per site location. "

1

59000

-

... More
Flameproof 25A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

20

590000

-

... More
Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

63

312525

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

12000

3540000

-

... More
Supply of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

7560

669060

-

... More
OTHER ACCESSORIES

-

-

-

... More
Supply of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

150

48144

-

... More
Supply of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

200

59000

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

7528

4441520

-

... More
150 mm width

400

127440

-

... More
100 mm width

200

35400

-

... More
50 mm width

200

25960

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

200

354000

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

180

849600

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

65

3988400

-

... More
Supply of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

50

17700

-

... More
Supply of Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

28

465203

-

... More
Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

3600

815616

-

... More
As built documentation for entire CCTV System : 3 sets of Hardbound and 5 sets of Soft form on DVDs,

1

23600

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

100

6490

-

... More
Supply of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

100

7080

-

... More
supply of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

100

12390

-

... More
supply of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

100

47200

-

... More
Supply of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

100

35872

-

... More
Supply , Design , installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment or supply the Power distribution panel for the LED Lights as per site requirements. Vendor to advice to Design as per site requirements without any price implementation.

1

52864

-

... More
PART-B INSTALLATION, ERECTION, TESTING & COMMISSIONING

-

-

-

... More
Installation, Testing & Commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

12

28320

-

... More
Installation, Testing & Commissioning of HD IP Fixed Dome camera with IR and MFZ lens including power supply unit / POE, surge protection unit and mounting accessories

15

35400

-

... More
Supply of HD IP PTZ Camera (2MP) including power supply unit /POE with POE injector (industrial grade), surge protection unit and mounting accessories.

49

144550

-

... More
Installation, Testing & Commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

13

38350

-

... More
Installation, Testing & Commissioningof IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

63

148680

-

... More
Installation, Testing & Commissioning of 8 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 8 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specifications and Tender Document.

45

53100

-

... More
Outdoor weather proof housing (IP 66) Panel with canopy suitable for installing Layer 2 switch / PSU / LIU / Adaptor for Ethernet switch / media convertor / surge protectors etc. The scope shall also include blinding plugs, double compression cable glands, etc. complete in all respect.

23

54280

-

... More
Installation, Testing & Commissioning of Outdoor Explosion proof cum weather housing (IP 65) Panel suitable for installing Layer 2 switch, PSU, LIU and adaptor for ethernet switch/media convertor surge protectors etc.. The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc complete in all respect.

22

51920

-

... More
Handling, Installation, Testing & Commissioning of Heavy Duty self supported Hot Dip Galvanized Poles along with civil foundation, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, foundations, SS bolts, accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document). Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

11

90860

-

... More
15 M pole with Accessories as per specification of Tender

14

82600

-

... More
7 M pole with Accessories as per specification of Tender

8

47200

-

... More
10 M pole with Accessories as per specification of Tender

10

59000

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

30

141600

-

... More
20 Meter Tower along with foundation.

2

82600

-

... More
Installation, Testing & Commissioning of rack mounted CCTV Server (s) along with 19" rack mounted industrial monitor, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

4720

-

... More
Installation, Testing & Commissioning of Network Attached Storage ( NAS ) / Server Attached Storage for 24Hrs. x 90 days of recording / 15 FPS at full resolution of camera, RAID-5 protection. (Vendor to submit the Hard Disc Calculation with necessary throughput considered)

1

10030

-

... More
Installation, Testing & Commissioning of CCTV client work station along with client software, with minimum 23" colored LED monitor, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. (Location : Control Room - 1 no. Rack type, Security room- 1 no. tower type, TM room - 1 no. tower type) Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors along with one no. of HD LED monitor. Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.

3

7080

-

... More
Installation, Testing & Commissioning of Ultra High Definition (4K) LED Display for the Monitoring with minimum 46" or more, supporting HDMI2.x resolution for location incharge room and Security room

2

4720

-

... More
Installation, Testing & Commissioningof Full HD LED Display for the Monitoring with minimum 75" or more, supporting HDMI2.x resolution for control room - Terminal

1

2360

-

... More
Installation, Testing & Commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document.

2

10620

-

... More
Installation, Testing & Commissioning of Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties etc complete in all respect for functioning of CCTV camera,terminal blocks and wiring etc complete as per specification and tender document For mounting of CCTV Servers, Analytics Servers, NAS/SAN , rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, PDB panel if required sepearte to be provided at no additionale cost ,MCBs etc as per specification and tender document

2

9440

-

... More
Testing & Commissioningof Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 100 cameras recording, 100 cameras viewing license, 2 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

11800

-

... More
Testing & Commissioningof Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Analytics Server with OS, Antivirus etc including analytic license for each camera complete as per specifications and Tender Document

1

59000

-

... More
Installation of of parallel redundant UPS of minimum capacity of 15 KVA or as per load calculation (whichever is higher) for entire CCTV equipments with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries ,monitoring software etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type Ni-Cd batteries.

1

11800

-

... More
Installation, Testing & Commissioningof UPS Power Distribution Panel for powering CCTV system. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use

1

2360

-

... More
Installation, Testing & Commissioning of Panel/feeder with contactors, MCCB, Fuse etc. required for powering the parallel redundant UPS and for providing power to bypass line. Note: The above item is applicable only when three independent feeders are not provided by IOCL and vendor needs to install separate panel along with MCCB, fuses etc (3 sets) for taking input power supply to UPS

1

2360

-

... More
Laying , Testing & Commissioningof all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP & Non FLP Junction Boxes( Power, Signal & Control) along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned above & below but are required as per tender & BOQ requirement for complete IP based CCTV Survellienace System as per specification and tender document.

1

59000

-

... More
Laying, Testing & Commissioning of 12 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

11830

488579

-

... More
Installation, Testing & Commissioningof required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, media converter along with power supply unit, Ethernet cable with RJ45 connector etc complete as per specifications and Tender Document required for entire CCTV system.

1

59000

-

... More
Laying Testing & Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

14800

296888

-

... More
Laying, Testing & Commissioning of 40 mm HDPE pipe of 3 mm thick in trenches, should be laid above ground for easy maintenance , as required for laying of cables in road, station piping crossing and cable rising up to instruments.

4302

192901

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 2.5 sqmm FRLS Copper Armoured cable.

13700

565810

-

... More
Laying , Testing & Commissioning of Power cable 3 C x 16 sqmm FRLS Copper Armoured cable for CCTV power

6453

304581

-

... More
Installation, Testing & CommissioningFlameproof 10 A,230V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3 x 16 sq.mm (Al) and 4 nos- 3C x 2.5 sq. mm (CU.) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

47

55460

-

... More
Installation, Testing & Commissioningof 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes to nearest earth grid.

2500

88500

-

... More
LED Based Lighting for Perimeter Camera

-

-

-

... More
Installation, Testing & Commissioning of minimum 400 Watt or as per site requirement whichever is higher LED flood light with suitable current control driver circuit including mounting arrangement complete as per specification and tender document. The required Lux level on either side of the perimeter at a distance of 20m from boundary wall shall be minimum 7 Lux and the light to be fitted on CCTV poles at a height of 8 m across the perimeter.

63

37170

-

... More
Installation, Testing & Commissioning"Lighting Sub Distribution Board (LSDB) :Supply of 415V,3 phase 4 wire 50 Hz, 63 A, Lighting Sub Distribution Board (LSDB) comprising of 1 no. 63A 4P MCB incomer feeder and 06 nos. 415V, 16A , 4 pole RCBO outgoing feeders as per Single Line Diagram shown in Drg. no. PC00088-0807 REV. 0. The lighting sub distribution boards shall have double door arrangement, fabricated out of 2.5 mm thick cold rolled sheet steel and shall be suitable for mounting on wall/structure. These shall have dust and vermin proof construction & suitable for outdoor installation, the enclosure shall conform to IPW-55 as per IS: 13947. Suitable canopy made out of 2 mm thick Aluminum sheet shall be supplied along with the board. The LSDB shall be provided with Heavy duty double compression type Aluminum cable glands with suitable PVC shroud, suitable for incoming and outgoing cables of size 3.5x50sq.mm (Al) XLPE, FRLS cables with separate terminal blocks, required lugs, earthing terminals, etc. The enclosure after suitable pre-treatment shall be painted with two coats of anti rust paint followed by two coats or anticorrosive paint. The finishing shade shall be light grey shade no.631 as per IS: 5. Routine test as per IS/ IEC shall be carried out on the LSDB and same shall be provided with the equipment. "

1

1770

-

... More
Installation, Testing & CommissioningFlameproof 16A, 415V, Ph-N, 6-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 2nos.-3.5C x50sq.mm (Al) and 4 nos- 3Cx2.5 sq. mm (CU) XLPE, FRLS cables, 2mm thick Alu canopy shall be provided.

20

23600

-

... More
Installation, Testing & Commissioning of Flameproof 16A, 240V, Ph-N, 3-way Junction boxes; Junction boxes with terminals block with additional earthing terminals and end clamps etc. including 3 Nos. Ex’d’ double compression stainless steel cable glands with PVC shrouds suitable for 3x2.5 sq. mm (cu.) XLPE, FRLS cables,

63

74340

-

... More
Laying , Testing & Commissioning of 3.5C x 50 sqmm (AL) FRLS Armoured cable for LED light

12000

566400

-

... More
Laying , Testing & Commissioning of 3C x 2.5 sqmm (Cu) FRLS Copper Armoured cable for LED light

7560

312228

-

... More
OTHER ACCESSORIES

-

-

-

... More
Laying , Testing & Commissioning of Cable conduits made up of GI pipes for medium class (B) etc as required for laying of cables in road, station piping crossing and cable rising up to instruments.

150

6724

-

... More
Laying, Testing & Commissioning of 150 mm RCC Hume pipes of NP3 class conforming to IS 458 under driveway and for culverts including excavation, providing collar joints, backfilling, etc.

200

8968

-

... More
Laying,, Testing & Commissioning of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
300 mm width

7528

1776608

-

... More
150 mm width

400

70800

-

... More
100 mm width

200

23600

-

... More
50 mm width

200

16520

-

... More
Providing Plain Cement Concrete (PCC) 1:2:4 using 20 mm nominal size aggregates conforming to latest IS 456 for all works in foundation, plinth & superstructure. Item includes cost of all materials etc complete as specified in detailed description.

200

16520

-

... More
Providing Reinforced Cement Concrete (RCC) of Concrete of nominal mix 1:1.5:3 conforming to latest IS 456 Item includes cost of all materials steel reinforcement, etc complete as specified in detailed description.

180

31860

-

... More
Fabrication of structural steel work for structural support of junction boxes, Field enclosure and Camera mounted on structures.

40

802400

-

... More
Installation of Cable marker for cable route at every bend of the trench and at every 25 m in straight run for identifying and locating cables directly buried underground. The marker shall be cast iron 5 mm thick plate with arrow indicating the route of the cable work etc.

50

7080

-

... More
Construction, Testing & Commissioningof Earth pit as per IS : 3043 with 100 mm dia of minimum 3.8 mtr length and backfilling ahomegeneous mixuture od Salt and Charcoal around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification

28

99120

-

... More
Laying, Testing & Commissioning of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, CCTV pole with Earthing grid/ Earth pit etc.

3600

637200

-

... More
Dismantling of existing and re erection on new concrete foundation (M 15) of approx. size 0.6M x 0.6M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II),as per Drawing and as per site condition, all complete as per site direction.

5

23600

-

... More
WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any.

10

5900

-

... More
Dismantling existing camera , encoder, FCU along with power adaptor , shifting and reinstallation on existing/new pole, structure etc including termination of cable for power and signal and fixing power adaptor in New/ existing Field mounted panel.

10

59000

-

... More
underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils : Brick duct for cables, 450mm wide (24 Bricks & 0.0494 cum per Mtr) as per specifications and direction of Engineer in charge.

2000

784880

-

... More
Integration of CCTV System with TAS & Safety PLC System for GUI for monitoring, Alarms & events logging, reporting, trending and archiving and its effects as per logic & its commissioning. Also Auto tracking of PTZ camera to defined Presets based on alarms triggered by TAS.

1

11800

-

... More
Installation, Testing & Commissioning of Power distribution panel 63A 4P MCCB 32 KA in vaccant compartment for the LED lights as per site requirements. Cable from the existing panel to lighting distribution panel (LDB).

1

987

-

... More
PART C - COMPREHENSIVE AMC for 7 Years

-

-

-

... More
Comprehensive Annual Maintenance Contract for a period of seven years for entire CCTV System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardware, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, rectification/ replacement of faulty CCTV equipment etc required for running and maintenance of the entire CCTV system to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor.

-

-

-

... More
First Year @ 4% of the basic CAPEX cost

1

2884347

-

... More
Second Year @ 4% of the basic CAPEX cost

1

2884347

-

... More
Third Year @ 7% of the basic CAPEX cost

1

5047607

-

... More
Fourth Year @ 7% of the basic CAPEX cost

1

5047607

-

... More
Fifth Year @ 10% of the basic CAPEX cost

1

7210867

-

... More
Sixth Year @ 6% of the basic CAPEX cost

1

4326520

-

... More
Seventh Year @ 12% of the basic CAPEX cost

1

8653041

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.