Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical Works
Eprocure
Opening Date
8 Oct 2019Closing Date
4 Nov 2019Tender Amount
₹ 30,00,000Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_267996_2Bid Award Id
ViewTender No
864/WS-43/2019-20Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and directed.
130
-
-
Sub class burnt bricks for cable protection complete all as specified and directed.
14.5
-
-
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm, 2 core laid in trenches complete all as specified and directed.
500
-
-
PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles complete all as specified and directed.
4
-
-
PCC 1:3:6 type C1 with 20mm graded stone aggregate in foundation of poles/stays including necessary form work complete all as specified and directed.
4
-
-
S&F in replacement of MCCBs TP / FP 415 Volts 50HZ adjustable including complete connections with incoming cable and outgoing cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under complete all as specified and directed for the following:- (a) MCCB 100 Amps TP, 415 volts 25 KA with thermal and magnetic setting
4
-
-
(b) MCCB 200 Amps 4 pole, 415 volts 35 KA with thermal and magnetic setting
6
-
-
(c) MCCB 400 Amps 4 pole 415 volts 35 KA with thermal and magnetic setting
4
-
-
(d) MCCB 160 Amps 4 poles, 415 volts 35 KA with thermal and magnetic setting
6
-
-
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh, lugs and test point complete all as specified and directed.
10
-
-
GI pipe light grade 50 mm dia in trenches for cable protection/on pole/on wall complete all as specified and directed.
54
-
-
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screw and single swan neck as specified type 410 SP - 22 (9 Mtr long) including removing existing unserviceable poles of any type complete all as specified and directed. (earth work and PCC will be measured and paid separately under relevant item of schedule 'A')
10
-
-
FRP cable looping boxes with PVC sheet finish inside including MCB SP 1 No, heavy duty PVC connector 4 way Terminal strip 01 no & fixed to pole with suitable size clamp with nuts, bolts complete all as specified and directed.
80
-
-
Timeline distribution board of 32 Amps 3 pole/230 volts-Digital time switch of Cat Pt No TL032DBO of Indoasian/L&T/Indoasian/Legrand complete all as specified and directed.
6
-
-
Bracket made out of GI tubing medium grade 40 mm bore , 90 cm long including MS clamps made out of MS flat iron 25 x 10 mm , nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer before fixing complete all as specified and directed.
80
-
-
S&F in replacement of 2 runs of PVC insulated 1.5 sqmm single core multistranded aluminium conductor cable and one run of 1 sqmm copper wire as earth continuity conductor drawn through and including rigid non metallic conduit 20 mm external dia fixed on poles & connecting up complete all as specified and directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length.
600
-
-
S&F in repair/replacement LED Street light fitting 72W, pressure die-cast aluminum complete fixing arrangement complete all as specified and directed. Make: Havells Cat Part No LHFAXU7DPN6J070 or equivalent in Philips/ Bajaj/ surya
70
-
-
Energy saving sleek 35W LED Post top luminaire made of pressure die cast aluminum IP 65 housing *& opal diffuser ( ENDURA SPRING 6) including suitable pole dis 76 mm , PVC flexible wire complete all as specified and directed. Make : Havells Cat No LHLC18145099 or equivalent in Bajaj/Philips
6
-
-
Preparing existing old surface of steel tubular poles of 09/11 Mtr long and applying one coat of aluminium paint on the surfaces complete all as specified and directed.
600
-
-
Painting black and white strips 05 Nos (each strip of 30 cm height) with synthetic enamel paint of black and white colour round the steel tubular pole alternatively from the bottom of the pole also including numbering of pole complete all as specified and directed.
600
-
-
Pin type insulator 100 mm height, 65 mm dia porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut, suitable for 1100 volt grade complete all as specified and directed.
50
-
-
Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps (31 x 5mm), washers, insulators bolts 14mm, washers and nuts, working pressure 1100 volts, height 100 mm, 115mm dia complete all as specified and directed.
50
-
-
Cross arm bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
3
-
-
ACSR conductor of any size on existing LT pole including copper binding or aluminium tap complete all as specified and directed.
4
-
-
Labour only for restringing of ACSR conductor any size/type complete all as specified and directed.
5
-
-
S&F in replacement of LED lamp 7 Watts capacity B-22 base complete all as specified and directed. Make : Havells /Surya/ Wipro
250
-
-
S&F in replacement of LED lamp 85 Watts capacity B-22 base complete all as specified and directed. Make: Havells/Surya/Wipro
100
-
-
LED light Driver unit suitable for LED light fitting of capacity 24/25/30 Watt complete all as specified and directed. Make: Bajaj/ Philips/ Havells/ Surya/ GoldWin
20
-
-
LED light Driver unit suitable for LED light fitting of capacity 45/48 Watt complete all as specified and directed. Make : Bajaj/ Philips/ Havells/ Surya/ GoldWin
15
-
-
LED light Driver unit suitable for LED light fitting of capacity 60/66 Watt complete all as specified and directed. Make: Bajaj/ Philips/ Havells/ Surya/ GoldWin
20
-
-
LED light Driver unit suitable for LED light fitting of capacity 72/80/90 Watt complete all as specified and directed. Make : Bajaj/ Philips/ Havells/ Surya/ GoldWin
35
-
-
LED light Driver unit suitable for LED light fitting of capacity 120/150/170 Watt complete all as specified and directed. Make: Bajaj/Philips/ Havells/ Surya/ GoldWin
25
-
-
Supply, laying and testing in replacement cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 16 sqmm, 4 core complete all as specified and directed.
500
-
-
Supply, laying and testing in replacement cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 6 sqmm, 2 core complete all as specified and directed.
700
-
-
Supply and laying in replacement of unserviceable GI tubing 50mm bore light grade as protection to under ground cable at road crossing, floor, fixed to walls , laid in trenches and along poles complete all as specified.
24
-
-
Cutting existing road/hardstanding of any type by using crow bar chisel etc not exceeding 45 cm wide and not exceeding 1.5 mtr depth for laying GI pipe including making good the surface by returning, filling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
40
-
-
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/ LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed. NOTE: All tools required for the job should be arranged by the contractor within the overall cost quoted in the item.
200
-
-
Evaluation Notes How It Works ?