Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure

Opening Date

8 Oct 2019

Closing Date

4 Nov 2019

Tender Amount

₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and directed.

130

-

-

... More
Sub class burnt bricks for cable protection complete all as specified and directed.

14.5

-

-

... More
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm, 2 core laid in trenches complete all as specified and directed.

500

-

-

... More
PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles complete all as specified and directed.

4

-

-

... More
PCC 1:3:6 type C1 with 20mm graded stone aggregate in foundation of poles/stays including necessary form work complete all as specified and directed.

4

-

-

... More
S&F in replacement of MCCBs TP / FP 415 Volts 50HZ adjustable including complete connections with incoming cable and outgoing cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under complete all as specified and directed for the following:- (a) MCCB 100 Amps TP, 415 volts 25 KA with thermal and magnetic setting

4

-

-

... More
(b) MCCB 200 Amps 4 pole, 415 volts 35 KA with thermal and magnetic setting

6

-

-

... More
(c) MCCB 400 Amps 4 pole 415 volts 35 KA with thermal and magnetic setting

4

-

-

... More
(d) MCCB 160 Amps 4 poles, 415 volts 35 KA with thermal and magnetic setting

6

-

-

... More
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh, lugs and test point complete all as specified and directed.

10

-

-

... More
GI pipe light grade 50 mm dia in trenches for cable protection/on pole/on wall complete all as specified and directed.

54

-

-

... More
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screw and single swan neck as specified type 410 SP - 22 (9 Mtr long) including removing existing unserviceable poles of any type complete all as specified and directed. (earth work and PCC will be measured and paid separately under relevant item of schedule 'A')

10

-

-

... More
FRP cable looping boxes with PVC sheet finish inside including MCB SP 1 No, heavy duty PVC connector 4 way Terminal strip 01 no & fixed to pole with suitable size clamp with nuts, bolts complete all as specified and directed.

80

-

-

... More
Timeline distribution board of 32 Amps 3 pole/230 volts-Digital time switch of Cat Pt No TL032DBO of Indoasian/L&T/Indoasian/Legrand complete all as specified and directed.

6

-

-

... More
Bracket made out of GI tubing medium grade 40 mm bore , 90 cm long including MS clamps made out of MS flat iron 25 x 10 mm , nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer before fixing complete all as specified and directed.

80

-

-

... More
S&F in replacement of 2 runs of PVC insulated 1.5 sqmm single core multistranded aluminium conductor cable and one run of 1 sqmm copper wire as earth continuity conductor drawn through and including rigid non metallic conduit 20 mm external dia fixed on poles & connecting up complete all as specified and directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length.

600

-

-

... More
S&F in repair/replacement LED Street light fitting 72W, pressure die-cast aluminum complete fixing arrangement complete all as specified and directed. Make: Havells Cat Part No LHFAXU7DPN6J070 or equivalent in Philips/ Bajaj/ surya

70

-

-

... More
Energy saving sleek 35W LED Post top luminaire made of pressure die cast aluminum IP 65 housing *& opal diffuser ( ENDURA SPRING 6) including suitable pole dis 76 mm , PVC flexible wire complete all as specified and directed. Make : Havells Cat No LHLC18145099 or equivalent in Bajaj/Philips

6

-

-

... More
Preparing existing old surface of steel tubular poles of 09/11 Mtr long and applying one coat of aluminium paint on the surfaces complete all as specified and directed.

600

-

-

... More
Painting black and white strips 05 Nos (each strip of 30 cm height) with synthetic enamel paint of black and white colour round the steel tubular pole alternatively from the bottom of the pole also including numbering of pole complete all as specified and directed.

600

-

-

... More
Pin type insulator 100 mm height, 65 mm dia porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut, suitable for 1100 volt grade complete all as specified and directed.

50

-

-

... More
Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps (31 x 5mm), washers, insulators bolts 14mm, washers and nuts, working pressure 1100 volts, height 100 mm, 115mm dia complete all as specified and directed.

50

-

-

... More
Cross arm bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.

3

-

-

... More
ACSR conductor of any size on existing LT pole including copper binding or aluminium tap complete all as specified and directed.

4

-

-

... More
Labour only for restringing of ACSR conductor any size/type complete all as specified and directed.

5

-

-

... More
S&F in replacement of LED lamp 7 Watts capacity B-22 base complete all as specified and directed. Make : Havells /Surya/ Wipro

250

-

-

... More
S&F in replacement of LED lamp 85 Watts capacity B-22 base complete all as specified and directed. Make: Havells/Surya/Wipro

100

-

-

... More
LED light Driver unit suitable for LED light fitting of capacity 24/25/30 Watt complete all as specified and directed. Make: Bajaj/ Philips/ Havells/ Surya/ GoldWin

20

-

-

... More
LED light Driver unit suitable for LED light fitting of capacity 45/48 Watt complete all as specified and directed. Make : Bajaj/ Philips/ Havells/ Surya/ GoldWin

15

-

-

... More
LED light Driver unit suitable for LED light fitting of capacity 60/66 Watt complete all as specified and directed. Make: Bajaj/ Philips/ Havells/ Surya/ GoldWin

20

-

-

... More
LED light Driver unit suitable for LED light fitting of capacity 72/80/90 Watt complete all as specified and directed. Make : Bajaj/ Philips/ Havells/ Surya/ GoldWin

35

-

-

... More
LED light Driver unit suitable for LED light fitting of capacity 120/150/170 Watt complete all as specified and directed. Make: Bajaj/Philips/ Havells/ Surya/ GoldWin

25

-

-

... More
Supply, laying and testing in replacement cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 16 sqmm, 4 core complete all as specified and directed.

500

-

-

... More
Supply, laying and testing in replacement cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 6 sqmm, 2 core complete all as specified and directed.

700

-

-

... More
Supply and laying in replacement of unserviceable GI tubing 50mm bore light grade as protection to under ground cable at road crossing, floor, fixed to walls , laid in trenches and along poles complete all as specified.

24

-

-

... More
Cutting existing road/hardstanding of any type by using crow bar chisel etc not exceeding 45 cm wide and not exceeding 1.5 mtr depth for laying GI pipe including making good the surface by returning, filling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.

40

-

-

... More
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/ LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed. NOTE: All tools required for the job should be arranged by the contractor within the overall cost quoted in the item.

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.