Allahabad Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Allahabad Development Authority - ADA Tender

Eprocure

Opening Date

24 Oct 2019

Closing Date

Cancelled

Tender Amount

₹ 1,54,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Notice inviting tender document with terms and condition
Financial BOQ for bidders rate quote
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S/F of 70 Sqmm to 120 Sqmm 11 KV Joint Kit complete

8

-

4723

... More
S/L of Aluminium conductor PVC Insulated armoured served sheathed cables 1100 volts grade ata depth of 750mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the E/I complete. in all respect. 400 Sq mm x 3.5 Core (Rate UPPWD SOR 18)

60

-

2048

... More
Same as above but 240 Sq mm x 3.5 C (Rate UPPWD SOR 18)

1000

-

1379

... More
Same as above but 150 Sq mm x 3.5 C (Rate UPPWD SOR 18)

900

-

957

... More
Same as above but 70 Sq mm x 3.5 C (Rate UPPWD SOR 18)

700

-

613

... More
Same as above but 25 Sq mm x 3.5 C (Rate UPPWD SOR 18)

30

-

373

... More
Same as above but 10 Sq mm x 4 C (Rate UPPWD SOR 18)

978

-

327

... More
S/F of 400 Sq mm cable Lugs (Rate UPPWD SOR 18)

16

-

596

... More
S/F of 240 Sq mm cable Lugs (Rate UPPWD SOR 18)

120

-

272

... More
S/F of 150 Sq mm cable Lugs (Rate UPPWD SOR 18)

120

-

146

... More
S/F of 70 Sq mm cable Lugs (Rate UPPWD SOR 18)

80

-

67

... More
S/F of 25 Sq mm cable Lugs (Rate UPPWD SOR 18)

16

-

27

... More
S/F of 10 sq mm cable Lugs (Rate UPPWD SOR 18)

140

-

20

... More
S/F of TPN/ Feeder Pillar Cubical Box made of 45mm x 45mm x 5 mm Angle Iron frame and 14 SWG MS Shhet with Both side Locking arrangement, Dust and Vermin Proof consistig with Copper Bus Bar on Henry Type Fuse unit on 2 No. 500 Amp and 3 No. 300 Ap. Tailless unit Complete the Box shall be Painted with approved aluminium Paint over Red Oxide Primer in 1:3:6 CC foundation as directed by E/I. PSR in PDA

2

-

24844

... More
S/F of factory fabricated and wired metal clade dust & warming proof floor mounting distribution feeder pillar with Incomming 400 Amp. 1 Nos. MCCB and outgoing 200 Amp 2 Nos. + 63 Amp 1 Nos cubical type with required busbar as IS 8623 with Insulated Heat Srink sleeving and mounting on non Hygrscotic support as CMC/ BMC . With 3 No. indicator. The Pillar should be fabricated with CRCA sheet 2 mm thick Painted with High quality Paint with locking arragement complete with cable gland as Rate SOR 18/S.N. 813 b- ii

18

-

201500

... More
S/E of SP 32 ST 9.00 Mtr long Pole complete with grouting in 1:3:6 CC including excavation & back filling SOR 18/ 613

2

-

14671

... More
S/F of 11 KV Pin insulator with Pin, Nuts & Bolts . PSR

18

-

58

... More
S/F of 11 KV Disc insulator with Gun fitting complete PSR

18

-

301

... More
S/F of MS Channel, Angel, Clamps Iron etc. Rate PSR

500

-

51

... More
S/F of 200 Amp Busbar Box made of 16 SWG CRCA Sheet including TPN Aluminium Busbar complete with locking arrangement with required Clamps nuts & bolts and grouting / .Fixed on Wall (if required on Angle stand angle will be measured in MS Items) Rate PSR in ADA

22

-

7300

... More
S/F of 11 Meter SP-55 Double Pole for substation with excavation of pit, grouting and plinthing in 1:3:6 ratio including 3 Nos. 100x50 mm 2.24 Meter Long and 2 Nos. 75x40 mm 2.24 Meter long MS Chanal required MS Clamps Nuts bolts. On Double 1 set of 11 KV TPMO and 11 KV Fuse set with required accessories Rate PSR in ADA

4

-

39927

... More
S/Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. Rate SOR-18

30

-

4076

... More
Trenchless Drilling 110 mm HDPE Pipe for carring of Cable on Road /Crossing complete with cost of pipe with Repairing of all internal water connection/ Sever Connection if necessary

600

-

1095

... More
S/L of 90 mm HDPE Pipe for carring of Cable on Road side complete with excavation & back filling complete

2000

-

330

... More
S/L of 50 mm HDPE Pipe for carring of Cable on Road side complete with excavation & back filling complete

750

-

99

... More
S/F of 100 mm Dia GI Pipe Complete. Rate PSR

54

-

717

... More
S/F Steel tubular Pole11 M. long designated 410 SP-55 in 1:3:6 cement concrete foundation including excavation back filling etc. complete Rate PSR

6

-

19963

... More
Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete S.I. No. 634/2018

16

-

324

... More
S/E of overhead line with ACSR conductor on Poles/service bracket including binding etc. complete S.I. No. 627/2018

50

-

263

... More
S/F of 100x110 mm Shackle Insulator including bolts/ Spindle nuts complete SOR 18 /621

10

-

79

... More
S/F of 230x32x1.5 mm Shackle Strips including bolts/Spindle nuts complete SOR 18 /622

10

-

113

... More
S/E of Stay set at least 3.5 M. away from the Pole complete with galvanised 19 mm dua x 1.80 M. long Stay rod, 30 cm x 30 cm c 6.3 mm anchor plate, thimble stay clamps, stay insulator. 19 mm x 600 double screw tightener, 7/3.5 mm G.I. stay wire etc. in 1:3:6 CC S.I. No. 631/2018

24

-

3029

... More
S/B of Pole Earthing with 2.5 M. long x 20mm dia MS Bar with 8 to 4 SWG G.I. Wire

71

-

328

... More
S/P of Reflectinbg Red colour 75 mm wide strip 3 M 1 Sqft around the pole above 1.5 Mt from GI Logo of ADA. PSR

35

-

280

... More
Supply and construction of Transformer Plinth 1.25x1.25 Meter x 2.3 Meter hight full brick work with 30 Cm foundation and 15 Cm hight CC in ratio 1:3:6 on Top with surface plastering and white wash complete in all respect. Rate PSR

2

-

6958

... More
S/F of wire mesh Fencing with 2 Mtr high cage fabricated with 3 mm thick expended matal fixed on 50x50x6 mm as complete Item UPPWD SOR 1142/2018

60

-

1275

... More
S/F of 11 KV Danger Board as per Rate SOR 18/S.N. 1109

26

-

85

... More
Removal and Refixing of service Connections complete

156

-

38

... More
S/F of 90 Watt LED street light fitting having die cast aluminium body and diffuser/Reflector with driver set suitable for 90 Watt. Confirming to IP 66 protection . Cat.AAA Rate SOR 18/1423

35

-

8850

... More
S/L of 6 Sq mm Twin Flate unarmoured cable complete with proper connections Rate PSR in PDA

400

-

19

... More
SITC of 7 Mtr GI Octagonal pole of approved make (Top dia 70 mm, Bottom dia 130 mm and base plate 12 mm thick) having 3 mm thickness with single arm bracket ( One Mtr Length) on RCC Foundation including the cost of Foundation, Foundation Bolts & Nuts, Excavation & Back Filling with required T&P complete in all respect. Rate SOR 641/2018

35

-

16500

... More
S/F of followign capacity of Automatic street light cubicle control Panel painted with anti corrosive alkeli and acie proof paint considting of tme switch TSO 100 serive/Digital type with Contactors, HRC fuses, 100 Amp MCCB isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complte in all respect .

2

-

29300

... More
Removal of ACSR store deposite as per UPPCL authority with cartege complete with crain charges labour T&P complete

500

-

13

... More
Dismantle of Steel Tubular Pole/PCC Pole Rate PSR

62

-

871

... More
Dismantiling & Removal of 11 KV S/S Transformer with Loading Unloading with Proper shifting including connections Structure Complete. Rate PSR

4

-

7300

... More
S/L of 3 Core 33 KV 300 Sqmm satandard aluminium conductor XLPE (Cross linked Polyethylene ) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S 7098 (Part-II with latest amendments) 11KV grade at a depth of 900 mm below ground level over a coushion of 100 mm thick fine river, sand all around and protected with well burnt bricks sides and on top put across. The armouring of cable shall be properly connected with eath conductory by clamps Rate PSR in Usuf Road Work but without GST

250

-

1943

... More
S/F of 300 Sq mm 33 KV Outdoor Joint Kit complete. Rate PSR Usuf Road Make MMM/Reychem

4

-

23105

... More
Trenchless Drilling with HDD for carring of Cable on Road Crossing complete with HDPE Pipe 160 mm dia with Repairing of all internal water connection/ Sever Connection if necessary complete

60

-

1971

... More
S/F of 100 mm Dia GI Pipe Complete. Rate PSR

24

-

1017



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.