Uttarakhand Urban Sector Development Agency Tender

... More
The UUSDA has issued a formal invitation for competitive bids for the Uttarakhand Urban Sector Development Agency project, for Development Of Water Supply System Intake Works, Rising Main, Oht Cwr, Distribution System, Pump House, House Service Connections And Allied Works, Including 2 Year O And M, At Pithoragarh In Uttarakhand. in Pithoragarh, Uttarakhand. The bid opening date for this tender is 06-11-2026 and the last date for bid submission is 22-12-2026. Interested bidders for Uttarakhand Urban Sector Development Agency tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.

Uttarakhand Urban Sector Development Agency - UUSDA Tender - Uttarakhand Tender

Opening Date6 Nov 2026
Closing Date22 Dec 2026
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Development Of Water Supply System Intake Works, Rising Main, Oht Cwr, Distribution System, Pump House, House Service Connections And Allied Works, Including 2 Year O And M, At Pithoragarh In Uttarakhand.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Earth Work for Pipeline and Its Ancillary Work

-

-

-

... More
Excavation in ordinary soil (loam, clay, sand) for pipe line trenches including lift up to 1.5 m and all leads with back filling in layers not exceeding 20 cm including consolidation, watering, ramming of excavated earth in the trenches.

75143

-

-

... More
Excavation in soil mixed with single bouldres etc. requireing the use of special T&P, if any, for pipe line trenches including lift up to 1.5 m and all leads with back filling, watering, ramming of excavated earth in the trenches.

62619

-

-

... More
Excavation in hard Rock by chiseling or mechanical means requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and all lead with back filling, watering, ramming of excavated earth in the trenches.

1378

-

-

... More
Dewatering of water caused due to seepage of ground water and surface water, including rain etc. excluding excavation of foundation but during execution of civil works including supply of all machine operator, khalashi, POL, T&P, accessories required for proper completion of the work including disposal to the nearest drainage or as as directed by Employers Representative

1500

-

-

... More
Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe ("B" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing suitably two rows of 100 mm wide PVC Tape preferabley of red colour. The M.S. pipe shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading the hole shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis).

186228

-

-

... More
Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe ("B" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing two rows of 40 mm dia M.S. pipe ("B" class) as horizontal members with nuts & bolts. Both vertical and horizontal members shall be painted in red and white colour strips as per approved pattern as when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading holes shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis).

124152

-

-

... More
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6 mm angle iron or 50x50x3 mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50 cm long MS angle 40x40x6 mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250 mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Employer's Representative which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Employer's Representative. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Employer's Representative.(Note : One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).

1862

-

-

... More
Providing and laying sand bedding and encasing all around the pipeline in trenches including watering, ramming, consolidating and dressing complete as per technical specification & as directed by Employer's Representative.

7885

-

-

... More
Providing & laying Granular bedding with graded hard crusher broken stone of 100% passing through 20mm sheive, 20 to 50 % passing through 10mm sheive and 100 % retain on 6.3mm sheive, laying in layers of thickness 10/15cm including ramming, consolidation etc complete for all type of pipes of following sizes as per drawing and or as directed by Employer's Representative

1353

-

-

... More
Pipe Line Works

-

-

-

... More
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of MS ERW Pipes grade Yst 210, Jointing by electric welding process with proper grade of eletrodes suitable for jointing of water supply pipe lines by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete.

-

-

-

... More
200 mm dia 4.8 mm thick

13826

-

-

... More
250 mm dia 4.8 mm thick

12793

-

-

... More
300 mm dia 5.6 mm thick

12261

-

-

... More
350 mmd dia 5.2 mm thick

3263

-

-

... More
400 mm dia 5.2 mm thick

8224

-

-

... More
450 mm dia 5.6 mm thick

5812

-

-

... More
Providing of all material Carting from site store to site of work. laying & jointing of G.l pipes confirming to IS :1239 (PART-1) including supply of all jointing materials Iike specials. white lead. hemp and oil etc in trenches with its cutting. threading and testing of pipe line etc complete.Heavy Duty Class C with testing of pipe line,disinfection, commissioning all complete as per technical specification & as per the direction of Employers Representativ

-

-

-

... More
40 mm dia

9546

-

-

... More
50 mm dia

14319

-

-

... More
65 mm dia

123082

-

-

... More
80 mm dia

36310

-

-

... More
100 mm dia

39746

-

-

... More
125 mm dia

10346

-

-

... More
150 mm dia

10502

-

-

... More
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of API Pipes confirming to API 5L / ISO 3183, Jointing by electric welding process with proper grade of eletrodes suitable for jointing of water supply pipe lines by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete. with testing of pipe line, disinfection, commissioning all complete as per technical specification & as per the direction of Employers Representative.

-

-

-

... More
250 mm dia 4.8 mm thick

10200

-

-

... More
300 mm dia 5.6 mm thick

150

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make & design standard of following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Employer's Representative Class PN 1.6 (Manually Operated), for the following:

-

-

-

... More
65 mm dia

93

-

-

... More
80 mm dia

23

-

-

... More
100 mm dia

15

-

-

... More
125 mm dia

9

-

-

... More
150 mm dia

5

-

-

... More
200 mm dia

7

-

-

... More
250 mm dia

3

-

-

... More
300 mm dia

5

-

-

... More
350 mm dia

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make & design standard of following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Employer's Representative Class PN 1.6 (Manually Operated), for the following:

-

-

-

... More
400 mm dia

1

-

-

... More
450 mm dia

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Scour valves of approved make & design standard of following dia complete including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Employer's Representative (Class (PN-1.6) Manually Operated), for the following-

-

-

-

... More
65 mm dia

72

-

-

... More
80 mm dia

7

-

-

... More
100 mm dia

21

-

-

... More
125 mm dia

3

-

-

... More
150 mm dia

7

-

-

... More
300 mm dia

4

-

-

... More
350 mm dia

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing in pipe line DI Kinetic Air Valves (PN1.6) as per IS 14845:2000 including isolation valve of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Employer's Representative, for the following-

-

-

-

... More
50 mm dia

16

-

-

... More
80 mm dia

98

-

-

... More
100 mm dia

51

-

-

... More
Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Employers Representative

-

-

-

... More
100mm dia

72

-

-

... More
150mm dia

26

-

-

... More
200mm dia

8

-

-

... More
250mm dia

6

-

-

... More
350mm dia

1

-

-

... More
400mm dia

1

-

-

... More
Supplying and fixing of Landing valve double outlet including stand pipe at suitable location and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect as per the direction of Employers Representative.

-

-

-

... More
100 mm diameter Fire Hydrant Confirming to IS: 5290 (Flanged)

20

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing DI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Employers representative.

-

-

-

... More
80 mm dia PN-1.6

116

-

-

... More
100 mm dia PN-1.6

15

-

-

... More
150 mm dia PN-1.6

5

-

-

... More
200 mm dia PN-1.6

7

-

-

... More
250 mm dia PN-1.6

3

-

-

... More
Construction of brick masonry Sluice Valve Chamber for different size of valves with 7.5 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100 mm thick leveling course of PCC 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Employers representative.

-

-

-

... More
For 100-150 mm dia pipe

183

-

-

... More
For 200-250 mm dia pipe

149

-

-

... More
For 300-350 mm dia pipe

13

-

-

... More
For 400-450 mm dia pipe

6

-

-

... More
Construction of brick masonry Air Valve Chamber for different size of valves with 7.5 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100 mm thick leveling course of PCC 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Employers representative.

-

-

-

... More
Upto-150 mm dia pipe

165

-

-

... More
For 200-250 mm dia pipe

1

-

-

... More
For 300-350 mm dia pipe

1

-

-

... More
For 400-450 mm dia pipe

1

-

-

... More
Construction of brick masonry Scour Valve Chamber for different size of valves with 7.5 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100 mm thick leveling course of PCC 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Employers representative.

-

-

-

... More
Upto 150 mm dia pipe

196

-

-

... More
Construction of RCC Electro-Magnetic Flow meter Chamber including earthwork excavation, 100 mm PCC (1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as leveling course, RCC M25 grade for base slab, side wall & cover slab including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Employers representative.

-

-

-

... More
Upto 250 mm dia pipe

58

-

-

... More
For 300-350 mm dia pipe

18

-

-

... More
For 400-450 mm dia pipe

3

-

-

... More
Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants,and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design and as directed by Employers Representative.

20

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

94

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).

715

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo- mechanically Treated bars of grade Fe-500D or more.

35773

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns

2320

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

100

-

-

... More
Over Head Tank, Tubewell and Pump House

-

-

-

... More
Supply of all materials, labor, T&P etc and construction of R.C.C. Sump of following capacities (in kiloliters) with M.S. ladder outside the tank and alluminium ladder inside of the tank, M.S. M.H. cover with locking arrangement, lightning conductor as per electricity rules, water level indicator,supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover, ventilator column etc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials. complete in all respect as per specifications, design, drawing & satisfaction of Employers Representative.

-

-

-

3

-

-

... More
40 KL

1

-

-

... More
Supply of all materials, labor, T&P etc and construction of R.C.C. Sump of following capacities (in kiloliters) with M.S. ladder outside the tank and alluminium ladder inside of the tank, M.S. M.H. cover with locking arrangement, lightning conductor as per electricity rules, water level indicator,supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover, ventilator column etc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials. complete in all respect as per specifications, design, drawing & satisfaction of Employers Representative.

-

-

-

60

-

-

... More
100 KL

100

-

-

... More
250 KL

250

-

-

... More
250 KL

250

-

-

... More
700 KL

700

-

-

... More
700 KL

700

-

-

... More
750 KL

750

-

-

... More
800 KL

800

-

-

... More
1100 KL

1100

-

-

... More
Construction of Over Head Tank including, Geotechnical investigation, Detailed Structural Design (Water retaining structure shall be designed confirming to IS: 3370-2021, Construction of Flat Bottom/Intze Type RCC Over Head Tank with Maintenance Gallery (M-30 Grade concrete) supported on RCC Beam Column Structure of sufficient staging height, designed for Safe Bearing Capacity as per the soil investigation report. The cost shall be all inclusive of supply, erection, construction, all testing, disinfecting and commissioning of reservoir, maintenance gallery, Dog-legged / suitable stairs, MS ladders with cage (maintenance gallery to top of roof & stairs from last landing to maintenance gallery), Aluminium ladder (from manhole to inside the tank), manhole frame with cover, handrail (around roof, maintenance gallery, up to manhole & along stairs), water proofing treatment of tank (polymer modified slurry coating), painting all exterior concrete surfaces with weather shield emulsion paint, providing piping arrangement with flanged D.I (K-9) pipes for inlet/s and outlet/s, scour and overflow, motorised DI sluice valves for inlet and OHT bypass, PRV and manual Sluice valve at bypass of outlet valve and manual sluice valve for scour, Float valve, sluice valve chambers, Flow meter chamber, plinth protection, surface drain, flooring below OHT, Grill Gate at start of stair, Landscaping, lightning arrestor with two earth pits etc. complete in all respect as per specifications, design, drawing & satisfaction of Employers Representative.

-

-

-

... More
150 KL

150

-

-

... More
450 KL

450

-

-

... More
Additional rates for staging per meter height beyond 12 m height including cost of all material, labour,shuttering, scaffolding T&P complete for following capacity ( in kiloliters ) Over Head Tanks

-

-

-

... More
150 KL

3

-

-

... More
450 KL

3

-

-

... More
Construction of Control Room building (G+1) as per drawing and technical specification including civil, electrical, mechanical, instrumentation, plumbing, EPABX system, PA system, CCTV system etc. complete in all respect as directed by Employer's Representative.

244

-

-

... More
Construction of SCADA cum Billing Room as per drawing and technical specification including civil, electrical, mechanical, instrumentation, plumbing etc.in all respect as directed by Employer's Representative.

875

-

-

... More
Construction of Operator Room / Pump House with toilet as per drawing and technical specification including civil, electrical, mechanical, instrumentation, plumbing etc.in all respect as directed by Employer's Representative.

348

-

-

... More
Construction of Pump House & Dosing Room at Tubewell location as per drawing and technical specification including civil, electrical, mechanical, instrumentation, plumbing etc.in all respect as directed by Employer's Representative.

40

-

-

... More
Construction of Admin Building with Chemical House and Labaratory as per drawing and technical specification including all civil, electrical, mechanical, instrumentation, plumbing etc.complete in all respect as per drawing, technical specification and as directed by Employer's Representative.

1030

-

-

... More
Construction of Staff Quarter as per drawing and technical specification including civil, electrical, plumbing etc.complete in all respect as per drawing, technical specification and as directed by Employer's Representative.

1794

-

-

... More
Construction of Septic tank (10 users) as per drawing and technical specification including all ancillary works in all respect as directed by Employer's Representative.

68

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in all respect as directed by Employer's Representative.

68

-

-

... More
Contstruction of Intake well including Pump House as per drawing and technical specification including civil, electrical,mechanical,instrumentation etc.complete in all respect as per drawing, technical specification and as directed by Employer's Representative.

1

-

-

... More
Construction of Approach Bridge for Intake Well

1

-

-

... More
Construction of Boundary wall as per drawing and technical specification including earth work, PCC work, RCC work, reinforcement, masonry work, plastering, painting, structural steel work, formwork, framework, etc.in all respect as directed by Employer's Representative.

1100

-

-

... More
Construction of Internal road as per drawing and technical specification including all ancillary works.in all respect as directed by Employer's Representative.

2700

-

-

... More
Construction of Entrance Gate with pillar including all ancillary works. in all respect as directed by Employer's Representative.

16

-

-

... More
Construction of Cable trench as per drawing & technical specification including earth work, PCC ,RCC , steel reinforcement, steel work. Etc in all respect as directed by Employer's Representative.

313

-

-

... More
Supply and Installation of Ultra Filtration (UF) system of 6.93 MLD Capacity as per Technical Specifications, including all Civil, Mechanical,Electrical and Instrumentation works and as per direction of Employers Representative

1

-

-

... More
House Service Connection

-

-

-

... More
Providing House Service Connection(Single Service connection) from HDPE/ Ductile Iron/GI distribution main to water meter, including supply & fixing of brass ferrule confirming to IS: 2692, clamp saddle of non corrosive Engineering Plastic(Polyethylene) body moulded with Stainless Steel threaded metal insert for tapping outlet.The stirrup metal plate shall be duly embedded in the plastic body, except at the place of nut-bolt lugs.Threading size & dimensions shall confirm to IS :554. The design of the saddle body should be such that, the service connection outlet metal insert shall project out towards pipe side & align with hole drilled on the pipe to ensure positive locking against rocking or creeping on the pipe, as might be caused by vibration, pressure or excessive external loading. Saddle seal shall be of virgin rubber SBR Grade 30 / NBR (NSF 61 approved). It shall be of type pressure activated hydro-mechanical design. It shall be contoured gasket to provide a positive initial seal, which increases with increase in the line pressure.Gasket shall be gridded mat, with tapered ends, with the outlet section having ring contacting the saddle body multiple rings contacting the pipe, preferably with a stainless steel reinforcing ring insert moulded to prevent expansion under pressure. Stainless Steel Type 304, NC rolled threaded, Tightening torque for1/2"(M12) nut bolt: 14g.m and for 5/8"(M16) nut bolt:21-23kg.m. Drilling the DI pipeline shall be through the chain and rachet mechanism and the drill hole shall be perpendicular to the axis of the DI pipeline, including supplying & laying MDPE PE 80 PN16 blue pipe as per ISO 4427 upto the property limit of both sides of road including supplying & fixing PP compression fittings such as Metal Insert Female Thread Adaptor with SS304 material (2Nos), Double compression elbow with compression on both sides (4Nos) complying to ISO 14236-2000 and GI plug-in for closure of ends/GI pipe with union to joint with existing connection, SS Ball Valve, FVC. All Pipes & fittings shall be PN 1.6 rating including transportion, loading & unloading at site, all labours, tools, eqipments etc. complete work including connecting new house service pipeline to existing/new legal house connection after completing the distribution pipeline as per the drawing & as directed by Employer's Representative.(Road Cutting & Restoration shall be paid separately)

-

-

-

... More
15 mm Connection

9103

-

-

... More
20 mm Connection

284

-

-

... More
25 mm Connection

95

-

-

... More
Making ferrule connection in the existing main of any type of pressure mains with the saddle piece, service connections, fitting and fixing of ferrule including tapping the mains all complete as per the design, drawing and as per the direction of Employers Representative

7000

-

-

... More
Road Cutting, Restoration & miscellaneous works

-

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish with all lead outside the periphery of the area cleared as per direction of Employer's Representative.

15000

-

-

... More
Dismantling of flexible pavements and disposal of dismantled materials with all lead, stacking serviceable and unserviceable materials separately as per Technical Specification and as per direction of Employer's Representative.

-

-

-

... More
By Manual Means

567

-

-

... More
By Mechanical Means

851

-

-

... More
Dismantling of cement concrete by mechanical means using concrete cutter tools & equipments to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials with all leads and lifts, stacking serviceable and unserviceable materials separately as per direction of Employer's Representative.

22946

-

-

... More
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material with all lead as per direction of Employer's Representative.

37801

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.

-

-

-

... More
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

1500

-

-

... More
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)

1000

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.For Grading I Material as per drawing and as per direction of Employer's Representative.

20355

-

-

... More
Granular sub-base/base/surface course with local materials (Table 400.13)/ by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408.

12802.5

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. as per drawing and as per direction of Employer's Representative.

-

-

-

... More
By Manual Means

1519

-

-

... More
By Mechanical means

13671

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.as per drawing and as per direction of Employer's Representative.

-

-

-

... More
By Manual Means

506

-

-

... More
By Mechanical means

4554

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.as per drawing and as per direction of Employer's Representative.

30366

-

-

... More
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 as per drawing and as per direction of Employer's Representative.

30366

-

-

... More
Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site with all lead laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504. (Bitumen VG-10 @ 3.3% of the weight of mix has been used for analysis purpose. The choice of bitumen will depend upon the prevailing site conditions and shall be in accordance with Clause 504 of MORD) as per drawing and as per direction of Employer's Representative.

152

-

-

... More
Providing and laying Semi Dense Bituminous Concrete with the use of batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects.Grading I - 13mm using Bitumen VG - 10 (bituminous binder @ 4.5 % of mix as per drawing and as per direction of Employer's Representative.

91

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 25 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. as per drawing and as per direction of Employer's Representative.

-

-

-

... More
By Manual Means Bitumen (VG-10)

3644

-

-

... More
Mechanical Means Bitumen (VG-10)

2429

-

-

... More
Providing and laying seal coat sealing the void in a bituminous surface laid to the specified levels, grade and cross fall using Type-A, Type-B and Type-C as per technicle specification clause 510 as per drawing and as per direction sof Employers,s Representative.

-

-

-

... More
By Manual Means, Type A Bitumen (VG-10)

5465.88

-

-

... More
Mechanical Means, Type A Bitumen (VG-10)

3643.92

-

-

... More
Providing concrete for plain/ reinforced concrete complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 - Nominal mix (1:2.5:5)

13370

-

-

... More
Providing concrete for plain/ reinforced concrete complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 - Nominal mix (1:2.5:5), Hand Mixing

600

-

-

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )-M-20

19642.5

-

-

... More
Providing and Laying of Interlocking Concrete Block (M-35) Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504,as per drawing and as per direction of Employer's Representative.

14090

-

-

... More
Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504,as per drawing and as per direction of Employer's Representative.

14090

-

-

... More
Laying serviceable cement concrete interlocking paver blocks of any design/shape/thickness laid in required line, level, curvature,colour and pattern over and including 50 mm thick compacted bed of coarse sand , filling the joints with fine sand etc. all complete as per drawing and as per direction of Employer's Representative.

15120

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material with all lead as per direction of Employers Representaive.In cement mortar

349.8

-

-

... More
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Employers Representaive.In cement mortar

315

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge (1:3:6)

150.96

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

542.26

-

-

... More
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.

33.64

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (Of area 3 sq. metres and below)

30

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. (For thickness of tiles 10 mm to 25 mm)

470

-

-

... More
Disposal of surplus dismantlled material obtained from road cutting by mehancical means including loading, unloading with all leads & lifts, to the dumping site as per the directions of the Engineer -in-charge Including all lead

1877.8

-

-

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

362

-

-

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand)

870

-

-

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.

200

-

-

... More
Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.

100

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

3066

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.

50

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

1116.8

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

478

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

240

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc

1200

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

10

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

10

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

10

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

57000

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.

-

-

-

... More
All works upto plinth level

497

-

-

... More
All works above plinth level upto floor V level

337

-

-

... More
Extra for providing richer mixes at all floor levels.Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

50

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

475.8

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)

227.2

-

-

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)

3049

-

-

... More
20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)

1163

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)

498.7

-

-

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications

133

-

-

... More
Pointing with cement mortar (1:3) on brick work as per drawing and technical specification Clauses 613.3 and 1204

1180

-

-

... More
Providing and Laying of Mechanically Woven Double Twisted Hexagonal shaped Gabions of galvanized steel, of size 3mX1mX1m with two diaphragms at 1 m interval, having mesh opening 100mmx120mm, mesh wirediameter3mm for gabions , edge/selvedge wire diameter 3.9 mm and lacing wire diameter 2.2mm.(The work includes filling boulders in the gabions).

100

-

-

... More
Painting on Steel Surfaces Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701

530

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

48

-

-

... More
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

2000

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate

1446.4

-

-

... More
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge

-

-

-

... More
50mm average thickness

620

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

550

-

-

... More
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.

-

-

-

... More
Bars upto 12 mm diameter

400

-

-

... More
Bars above 12 mm diameter

550

-

-

... More
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.

-

-

-

... More
Upto and including 12mm dia.

100

-

-

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.

-

-

-

... More
Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

500

-

-

... More
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).

-

-

-

... More
12 mm average thickness

160

-

-

... More
Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member.Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member.

-

-

-

... More
50mm thick in Grade M 25 with cement content not less than 330 kg per cum

1620

-

-

... More
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge.(The payment shall be made on the basis of actual weight of approved grout injected.)

-

-

-

... More
Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work.

200

-

-

... More
Dismantling of Exsiting structures including disposal of dismantled material all complete as per the direction of Employers Representative.

4

-

-

... More
Finishing walls with water proofing cement paint of required shade

3579

-

-

... More
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).

960

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

20000

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

350

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- in-charge.

150

-

-

... More
Supply and installation of single stage centrifugal water pump with all accessories such as gate valves, flexible coupling, strainers, check valves consist with automatic pump stater and stop with low and high water levels of over head tank.

-

-

-

... More
Pump capacity 60 l/m on @25m head

12

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : white solid plastic seat and lid

24

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.

36

-

-

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS 13983. Kitchen sink with drain board 510x1040 mm bowl depth 200mm.

12

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. Semi rigid pipe 40mm dia

48

-

-

... More
Providing and fixing soil, waste and vent pipes: 100 mm dia. Sand cast iron S&S pipe as per IS: 1729.

375

-

-

... More
Providing and fixing soil, waste and vent pipes: 75 mm dia. Sand cast iron S&S pipe as per IS: 1729.

300

-

-

... More
Providing and filling the joints with spun yarn cement slurry and CM 1:2. 75 mm dia pipe

168

-

-

... More
Providing and filling the joints with spun yarn cement slurry and CM 1:2. 100 mm dia pipe

252

-

-

... More
Providing and fixing plain bend of required degree. 100 mm dia. Sand cast iron S&S pipe as per IS: 1729.

108

-

-

... More
Providing and fixing plain bend of required degree. 75 mm dia. Sand cast iron S&S pipe as per IS: 1729.

72

-

-

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260 gms

48

-

-

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263 gms.

36

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 15 mm dia nominal bore:

750

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Iinternal work - Exposed on wall. 20 mm dia nominal bore:

270

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Iinternal work - Exposed on wall. 25 mm dia nominal bore:

180

-

-

... More
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore

140

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 25 mm nominal bore

54

-

-

... More
Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length. 15 mm nominal bore

255

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

18000

-

-

... More
Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 107mm long, weighing not less than 110 grams.

72

-

-

... More
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated rod with L.P./ H.P.H.D. plastic ball. 15 mm nominal bore, 105mm long, weighing not less than 138gms.

18

-

-

... More
Providing and fixing square-mouth S.W. gully trap grade ‘A” complete with C.I.100x100 mm size P type With F.P.S. Bricks class designation 75

180

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg): With F.P.S. bricks class designation 75

24

-

-

... More
Providing, Installation Testing And Commissioning Of Automatic chlorine dosing system: Principle : Time Of Flight Electronic Dosing Pump with LCD display, 4-20 MA communication with Chlorine Analyser, enable with proportional dosing (1W&1S) unit : with Process Connection, Common discharge & NRV

8

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design

72

-

-

... More
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I, cover (heavy duty) the weight of the cover to be not less than 108 kg.

24

-

-

... More
Ambient Air Quality

108

-

-

... More
Noise Quality

108

-

-

... More
Ground water Testing

108

-

-

... More
Surface water Testing

108

-

-

... More
Electrical Works

-

-

-

... More
Supply Installation Testing & Commissioning of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c), (d) below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear. (c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. Complete in all respect as per specification, design, drawing & as directed by Employer Representative.

353

-

-

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade Aluminium bus bar 6010 grade

81.5

-

-

... More
Providing & Fixing of BIS approved Current Transformer as for electrical Works ,ISI marked as per IS 2705- 1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified.

-

-

-

... More
C T Class 1, Ratio upto 150/5, Burden 10 VA

84

-

-

... More
C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA

66

-

-

... More
CT Class 1, Ratio 400/5 to 1200/5, Burden 15 VA

60

-

-

... More
Providing & Fixing of IP 51 Multi function meter for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc.

-

-

-

... More
Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port.

26

-

-

... More
Providing & Fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. All as per pre approved by Employer Representative

-

-

-

... More
Luminous type Red , Yellow, Green, Amber

180

-

-

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required.

-

-

-

... More
Red/yellow/Green/Amber colour

360

-

-

... More
Blue Colour

41

-

-

... More
Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurements, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV.

-

-

-

... More
Digital type

29

-

-

... More
Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field-programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required.

-

-

-

... More
Digital type Confirming to IEC 62053-21, Below 500 A

27

-

-

... More
Digital type Confirming to IEC 62053-21, Above 500 A

4

-

-

... More
Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided .

29

-

-

... More
Providing & Fixing of ISO certified company made CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided .

31

-

-

... More
Incoming- SITC of IP 40 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardant & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C for electrical works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanism, true contact position indicator, line load inter-changeability, designed for both vertical and horizontal mounting with out any adverse effect on electrical performance, suitable for operation up to 55 degree and derating up to 40 degree.

-

-

-

... More
With Thermal Magnetic release Upto 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 %Icu

8

-

-

... More
With Thermal Magnetic release 160 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 %Icu

2

-

-

... More
With Microprocessor based release 250 Amp , 35 kA, adjustable O/L & Adjustable S/C setting, Ics = 100% Icu

2

-

-

... More
With Microprocessor based release 400 Amp ,50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu

8

-

-

... More
With Microprocessor based release 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu

2

-

-

... More
Incoming- SITC of Draw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker (ACB) for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short- circuit,earth fault and with separate LED indication for each type of fault , Password protected release (trip mechanism) shall confirm to EMI/EMC test , LCD/LEDdisplay , Thermal memory , pollution degree 4, trip free mechanism , suitable for ambient 50 degree and utilization category B.

-

-

-

... More
With Microprocessor based release draw out type (Mannual Spring Charged) 4 Pole. 1000 A, 50kA

4

-

-

... More
Outgoing- SITC of IP 40 3 pole current limiting Moulded case circuit setting for electrical works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanism, true contact position indicator, line load inter-changeability, designed for both vertical and horizontal mounting with out any adverse effect on electrical performance, suitable for operation up to 55 degree and without B587 derating up to 40 degree, pollution free degree 3 having positive isolation capacity, push (test) to trip, trip time less than 10 ms under s/c condition.With Thermal Magnetic release

-

-

-

... More
Upto 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 %Icu

13

-

-

... More
160 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 %Icu

6

-

-

... More
250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu

10

-

-

... More
400 Amp , 50 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu

6

-

-

... More
Outgoing- SITC of Draw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker (ACB) for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short- circuit,earth fault and with separate LED indication for each type of fault , Password protected release (trip mechanism) shall confirm to EMI/EMC test , LCD/LEDdisplay , Thermal memory , pollution degree 4, trip free mechanism , suitable for ambient 50 degree and utilization category B.With Microprocessor based release draw out type (Mannual Spring Charged) 3 Pole

-

-

-

... More
800 A, 50kA

10

-

-

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 up to 32 A rating and 10,000 up to 63 A, 5000 for 80 A rating including making connections, testing etc. as required. complete in all respect as per specification, design, drawing & as directed by Employer Representative.

-

-

-

... More
4P, 6-32 A

64

-

-

... More
S & F of Star delta Starter with MCB,Main and Aux Contactor,O/L Relay, L/R Selector Switch,3 Indicating lamps,Start-Stop Push Button ,Control MCB with panel with all accessories with following rating

-

-

-

2

-

-

... More
18.5 KW

2

-

-

... More
22.5 KW

2

-

-

7

-

-

... More
SITC of Variable Frequency Drives with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

2

-

-

4

-

-

... More
125 KW

10

-

-

... More
160 KW

4

-

-

... More
180 KW

2

-

-

... More
350 KW

10

-

-

... More
Supply Installation Testing & Commissioning of chemical Gel earthing system of Dual Pipe Technology made of with "B" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL accredited lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per reference of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendments (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less. (e) Self certificate for confirming above standards from OEM is mandatory. With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell Complete in all respect as per specification, design, drawing & as directed by Employer Representative.

-

-

-

... More
GI pipe 3000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip

185

-

-

... More
Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. Complete in all respect as per specification, design, drawing & as directed by Employer Representative.

-

-

-

... More
50mm x 6mm copper strip

430

-

-

... More
50mm x 6mm G.I. ( Hot Dipped ) Strip

4140

-

-

... More
25mm x 6mm G.I. ( Hot Dipped ) Strip

3350

-

-

... More
S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026- 1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C up to 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge. No Load Voltage ratio : 11/0.433 KV, No. of phases / frequency : 3 Phases/ 50 Hz

-

-

-

... More
40 KVA

2

-

-

... More
63 KVA

6

-

-

... More
100 KVA

2

-

-

... More
160 KVA

2

-

-

... More
200 KVA

6

-

-

... More
250 KVA

2

-

-

... More
315 KVA

2

-

-

... More
630 KVA

4

-

-

... More
Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’. Complete in all respect as per specification, design, drawing & as directed by Employer Representative.

26

-

-

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.

-

-

-

... More
3C, 16 sqmm

170

-

-

... More
3.5 C, 25 Sqmm

200

-

-

... More
3.5 C, 50 Sqmm

300

-

-

... More
3C, 70 sqmm

50

-

-

... More
3C, 95 sqmm

400

-

-

... More
3C, 120 sqmm

240

-

-

... More
3C, 185 sqmm

480

-

-

... More
3.5C, 185 Sqmm

300

-

-

... More
3C, 240 sqmm

100

-

-

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.

-

-

-

... More
3.5C, 300 Sqmm

600

-

-

... More
3.5C, 400 Sqmm

150

-

-

... More
P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required

-

-

-

... More
3.5 C, 25 Sqmm

200

-

-

... More
10.0 Sq.mm 3 core flat

80

-

-

... More
Wiring for light point/fan point/exhust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, sutaible size M.S. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper condutor single core cable etc. as required all as per pre approved by Employer Representative, making connections, testing etc. complete as required. Complete in all respect as per specification, design, drawing & as directed by Employer Representative.

-

-

-

... More
Group A

52

-

-

... More
Suppling & fixing of following sizes medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of reccessed conduit as required; 25 mm Complete in all respect as per specification, design, drawing & as directed by Employer Representative. MMS ( IS:9537 P - III ) PVC conduit, 25 mm

260

-

-

... More
Supplying & Fixing metal box of 180 mm X 100 mm X 60 mm Deep (Nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc as required.

13

-

-

... More
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVS conduit as required

-

-

-

... More
4x2.5 Sq.mm.

260

-

-

... More
Suppling & Fixing following way, single pole and neutral, sheet steel, MCB Distribution board, 240 V, on surface/ recess, complete with tinned Copper Bus Bar, neutral bus bar, din bar, interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Isolater)

13

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolater in exisitng MCB DB complete with connections, testing and commissioing etc as required; 63 A

13

-

-

... More
Supplying & fixing 5A to 32 A rating, 240/415V, 10 kA, "C" curve, MCB suitable for inductive load of following poles in the exisiting MCB DB complete with connections, testing & Commissioning etc as required: Single Pole

39

-

-

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. 4' LED Tube shape fixture 18/20 W (Extruded Al Base)

39

-

-

... More
Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate /Extruded Al Base Housing & diffuser SMD Mid Power LED tube (with integral driver), on existing fixture. Power Consumption of 18W / 20W system lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV ,THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Employers Representative 4', 18/ 20 Watt LED Tube Without Batten (Extruded Al Base)

39

-

-

... More
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Employer Repersentative.

13

-

-

... More
Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629; 3 Mtr

13

-

-

... More
Supply & Fixing of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have in house R&D Laboratory which is recognised by ministry of Science & Technology department, Govt. OfIndia/ NABL. Bidder shall have inhouse pole & luminaire manufacturing facility. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/Philips / Crompton. Compact Solar LED Street Light - 20W(MONO) 18V/ 12.8V9Ah/12W

13

-

-

... More
Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per Relavent IS specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. Complete in all respect as per specification, design, drawing & as directed by Employer Representative.

13

-

-

... More
Mechanical Works

-

-

-

... More
Vertical Turbine Pumps Supply, Testing & Commissioning of Vertical Turbine pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 415 V ± 10%, rated speed 1450 RPM along with column and bowl assembly, discharge head, base channel/RSJ etc. complete as per relevant IS. M.O.C.: Impeller & Sealing Rings: CF8M, Bowl & Suction Bell: Cast Steel WCB , Shaft with coupling: SS 410, Column Pipe: M.S. Mechanical Seal (above 30 kW),ERW, , Base Plate: MS, Line Bearing: Thordon type, Suction Strainer: S.S. ,all complete as per Technical Specifications , Drawing & as directed by employer's Representative.

-

-

-

... More
Centrifuge Pump, Vertical Type Working +Stand by Capacity-129 CUM/Hr, Head - 35 m(25KW)

3

-

-

... More
Centrifuge Pump, Vertical Type (Store Stand by) Capacity-129 CUM/Hr, Head - 35 m(25KW)

1

-

-

... More
Centrifuge Pump, Vertical Type Working +Stand by Capacity-200 CUM/Hr, Head - 50 m(55KW)

4

-

-

... More
Centrifuge Pump, Vertical Type (Store Stand by) Capacity-200 CUM/Hr, Head - 50 m(55KW)

1

-

-

... More
Centrifuge Pump, Vertical Type Working +Stand by Capacity-159 CUM/Hr, Head - 80 m(75KW)

5

-

-

... More
HSC pump/ HSCF Pumps Supply, Testing & Commissioning of Horizontal Split casing centrifugal pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity, horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 415 V ± 10%, rated speed 1450 RPM along with fabricated MS base frame, coupling, coupling guard, foundation bolts etc. as per relevant IS. M.O.C.: Impeller & Wearing Rings: CF8M, Casing: Cast Steel WCB , Shaft: SS 410, Shaft Sleeve: SS 410, Mechanical Seal (above 30 kW), Base Frame: MS.

-

-

-

... More
Centrifuge Pump, Horizontal Type (Working +Standby) Capacity-129 CUM/Hr, Head - 200 m (125KW)

3

-

-

... More
Centrifuge Pump, Horizontal Type (Store Stand by) Capacity-129 CUM/Hr, Head - 200 m (125KW)

1

-

-

... More
Centrifuge Pump, Horizontal Type Working +Stand by Capacity-129 CUM/Hr, Head - 535 m (350KW)

3

-

-

... More
Centrifuge Pump, Horizontal Type Store Stand by Capacity-129 CUM/Hr, Head - 535 m (350KW)

1

-

-

... More
Centrifuge Pump, Horizontal Type Working +Stand by Capacity-129 CUM/Hr, Head - 535 m (350KW)

3

-

-

... More
Centrifuge Pump, Horizontal Type Store Stand by Capacity-129 CUM/Hr, Head - 535 m (350KW)

1

-

-

... More
Centrifuge Pump, Horizontal Type Working +Stand by Capacity-129 CUM/Hr, Head - 195 m (125KW)

5

-

-

... More
Centrifuge Pump, Horizontal Type Store Stand by Capacity-129 CUM/Hr, Head - 195 m (125KW)

1

-

-

... More
Centrifuge Pump, Horizontal Type (Working +Standby) Capacity-91 CUM/Hr, Head - 410 m (180KW)

2

-

-

... More
HSC pump/ HSCF Pumps Supply, Testing & Commissioning of Horizontal Split casing centrifugal pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity, horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 415 V ± 10%, rated speed 1450 RPM along with fabricated MS base frame, coupling, coupling guard, foundation bolts etc. as per relevant IS. M.O.C.: Impeller & Wearing Rings: CF8M, Casing: Cast Steel WCB , Shaft: SS 410, Shaft Sleeve: SS 410, Mechanical Seal (above 30 kW), Base Frame: MS.

-

-

-

... More
Centrifuge Pump, Horizontal Type Working +Stand by Capacity-153 CUM/Hr, Head - 180 m(160KW)

5

-

-

... More
Centrifuge Pump, Horizontal Type Working +Stand by Capacity-20 CUM/Hr, Head - 220 m(22.50KW)

5

-

-

... More
Centrifuge Pump, Horizontal Type Store Standby Capacity-91 CUM/Hr, Head - 410 m (180KW)

1

-

-

... More
Submersible pump Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in-charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
Subermersible Pump Working .PROPOSED TW for Shikdani Chandak ,PUMP CAPACITY 17 CUM/HR , HEAD 125 M (12.5 KW )

2

-

-

... More
Submersible Pump, Working +Stand by Capacity-24 CUM/Hr, Head - 120 m

3

-

-

... More
Supply, installation, testing and commissioning of glycerin filled Pressure gauge/Compound gauge of following ranges with isolation valve and tap off pipe ,all complete as per Technical Specifications , Drawing & as directed by employer's Representative.0-15 Kg/Cm2

50

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per directionof Engineer. Electrically Operated & SCADA Compatible class PN 1.6 SV For Pump House/Tubewell

-

-

-

4

-

-

... More
100 mm

16

-

-

... More
200 mm

64

-

-

... More
250 mm

23

-

-

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/Fresilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG- 400/12 as per IS 1865 or Equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. NRV PN Rating as per Requirement

-

-

-

2

-

-

... More
100 mm

8

-

-

... More
200 mm

30

-

-

... More
250 mm

10

-

-

... More
Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.MS Pipe specials up to 600mm dia (with minimum 5mm thickness sheet

-

-

-

... More
Column pipe

36442.1

-

-

... More
90 Degree Bend

3999.77

-

-

... More
AF Tee

6693

-

-

... More
DF Pipe

78505.31

-

-

... More
Concentric Enlarger

2257.26

-

-

... More
Electromagnetic Flowmweter Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) andmaking connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as perdirection of Engineer.

-

-

-

2

-

-

... More
100 mm

2

-

-

... More
200 mm

1

-

-

... More
250 mm

2

-

-

... More
300 mm

8

-

-

... More
Electrical operated Travelling Crane Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. 5 MT Capacity Span 9 M and Lift 6 M

8

-

-

... More
Electrical operated Travelling Crane Extra Lift for EOT at Intake well

60

-

-

... More
Electrical operated Travelling Crane Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer. 3 MT Capacity Span 7 M and Lift 6 M

1

-

-

... More
Electrical operated Travelling Crane Extra Lift for EOT at I- well

30

-

-

... More
Supply, installation and commissioning of Mono Rail Single Girder Crane suitable for lift up to 9m with chain 9m pulley block and traveling trolley excluding cost of girder complete in all respect as per the direction of the Engineer. Capacity-1T

2

-

-

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. Dia 600MM

150

-

-

... More
Supply, Installation, Testing and Commissioning of CI Thimble Mounted Sluice Gate, Manually operated, Rising Spindle type. Sluice gates are as per IS 13349 Including all taxes, Freight, loading, unloading, fitting in position including Sluice gates are upward opening wall thimble mounted suitable for isolating the flow of sewer into out of the opening in the wall. It consists Gate frame, wall thimble, gate slide, shutter, seating/sealing faces .The gates will be provided with pads on sides, top and bottom to mount the wedges. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame & Shutter of CI Grade IS 210 FG 260, Head Stock assembly bolts & SS ASTM A276 Type 316, Stem, Operating Nut SS ASTM A276 Type 316., Duly tested for tensile strength, Tested for overall dimensions as per approved GA drawing complete in all respect as per specification and direction of Engineer for following PEAK FLOW

10

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.Electrically Operated & SCADA Compatible class PN Rating as per Requirement

-

-

-

... More
300 mm dia

4

-

-

... More
500 mm dia

4

-

-

... More
SCADA & INSTRUMENTATION WORKS

-

-

-

... More
Automation system work for entire local & remote equipment / instrument communicable with all iRTU/PLC Panel, field Instruments of all DMA areas of entire Pithogarh WSS scope of work will be will be Located near Hanuman Mandir for controlling all exesting and proposed system of Tubewell, Sump, OHT's, Intake & WTPs etc.Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size 1200 mm x 800 mm x 2100mm (lbh) , fabricated out of approx.min. 2 mm thick CRCA sheet Steel complete with latest configuration PC, necessary programming and Scada software and comprising of all accessories Not limited to the following.CENTRALISED REDUNDANT PROCESSOR For all RTU Station GIS based Communication, all field Instrument

-

-

-

... More
FOR DI CHANNEL-Card with 16 channel & with base channels FOR DO CHANNEL-Card with 16 channel & with base channel RELAY CARD - with 8 channels AI CHANNEL - card with 8 channels & with base channels AO CHANNEL- card with 4 channels & with base channels SCADA Software & Centralised Cloud Based System, Data Acquisition & Remote Monitoring etc. Programming Software Communication Card With Cable System Cabinet/ Panel 24V Dc Power Supply Redundant Remote I/O Panel Server Marshalling Panel Hardware Switchgear Lot Computer-32"LED –Engg. Stn.1No .& Operating Stn-1 Nos.. Total -2 Nos. Common Desktop for Centralised SCADA Centre Lazer Printer-A4- Colour Printer Aux. Contactor-Lot Furniture Air Conditioner-1.5 T UPS-Redundant 2Kva, 150 AH*2 Battery Unit, Backup For 3 Hours Backup Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End Fibre Optic Cable Remote I/O Panel-Lot Converter For Foc

1

-

-

... More
iRTU PANEL WITH HMI AT EXISITNG & PROPOSED I-Well, Pump House, IPS etc Design, manufacture, supply, installation, testing & commissioning of indoor type PLC panel with 10” HMI , with size 800 mm x 800 mm x 2100mm (lbh) , fabricated out of approx. min. 2 mm thick CRCA sheet complete with , necessary programming and HMI software and comprising of all accessories not limited to the following

-

-

-

... More
REDUNDANT PROCESSOR with 48nos. I/O capacity with 10” HMI FOR DI CHANNEL-Card with 16 channel & with base channels FOR DO CHANNEL-Card with 16 channel & with base channel RELAY CARD - with 8 channels AI CHANNEL - card with 8 channels & with base channels AO CHANNEL- card with 4 channels & with base channels HMI with Programming Software Communication Card With Cable System Cabinet/ Panel Power Supply Redundant Hardware & Software Development –Lot Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End With Dual Sim UPS- 2 Kva with 150 AH*2 Battery Unit, Backup For 3 Hours for all RTU Panel Location

21

-

-

... More
iRTU PANEL WITHOUT HMI AT FIELD LOCATION Design, manufacture, supply, installation, testing & commissioning of PLC panel without 10” HMI, fabricated out of approx. min. 2 mm thick CRCA sheet complete with , necessary programming and HMI software and comprising of all accessories not limited to the following Not limited to the following

-

-

-

... More
REDUNDANT PROCESSOR with 48nos. I/O capacity with 10” HMI FOR DI CHANNEL-Card with 16 channel & with base channels FOR DO CHANNEL-Card with 16 channel & with base channel RELAY CARD - with 8 channels AI CHANNEL - card with 8 channels & with base channels AO CHANNEL- card with 4 channels & with base channels Communication Card With Cable System Cabinet/ Panel Power Supply Redundant Hardware & Software Development –Lot Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End With Dual Sim UPS- 2 Kva with 150 AH*2 Battery Unit, Backup For 3 Hours for all RTU Panel Location

66

-

-

... More
Billing Centre Accessories accessories not limited to the following

-

-

-

... More
Common Desktop for Billing Centre Centre

4

-

-

... More
Printer

2

-

-

... More
Furniture Set [Workstation Table, chair, Almirah/Rak etc.

2

-

-

... More
Online payment SWAP Machine & other accessories

4

-

-

... More
ELECTROMEGNATIC FLOW TRANSMITTER AT DMA INLET LINE, OHT/GLSR DISCHARGE DATA LOGER & COMMUNICABLE WITH RTU/SCADA INTEGRATED FLOW TRANSMITTER Electro Magnetic Type Bulk Flowmeter ( Bfm ): Providing, Installation, Testing And Commissioning Of Bulk Flow Meter With Removable Mechanism Class "B" Confirming To ISO: 4064/1 Including All Materials (Including CI/DI Fittings) and making Connection With new / existing Pipeline required For Bulk Flow Meter For At Feeder Line From Oht With 4-20mA Signal (at Inlet/outlet of OHT/GLSR & DMA inlet)

-

-

-

... More
DN80 mm

4

-

-

... More
DN125 mm

4

-

-

... More
DN150 mm

13

-

-

... More
DN200 mm

15

-

-

... More
DN250 mm

15

-

-

... More
DN300 mm

2

-

-

... More
DN350 mm

8

-

-

... More
DN450 mm

3

-

-

... More
ELECTRICALLY OPERATED SLUICE VALVE FOR OHT/GLSR OUT LINE, ELECTRICALLY OPERATED ON OFF SLUICE VALVE WITH MANUAL OPERATING HANDEL AT DMA INLET LINE REMOTELY COMMUNICABLE WITH iRTU / PLC / SCADA FOR ON/OFF COMMAND

-

-

-

... More
DN80 mm

2

-

-

... More
DN125 mm

2

-

-

... More
DN150 mm

6

-

-

... More
DN200 mm

7

-

-

... More
DN250 mm

7

-

-

... More
DN300 mm

1

-

-

... More
DN350 mm

4

-

-

... More
DN450 mm

2

-

-

... More
Providing, Installation, Testing And Commissioning Of multijet domestic mechanical water meter Class-B dry dial, temper proof confirming to IS: 779-1994 or ISO 4064-2005 IP68 in position including all material, laboor, T&P etc complete for following Water Line Sizes including meter box for protection complete with all lead and lift

-

-

-

... More
15mm Water Meter

9103

-

-

... More
20 mm Water Meter

284

-

-

... More
25 mm Water Meter

95

-

-

... More
Providing, Installation Testing And Commissioning Of Pressure Transmitter: : for online pressure Measurement of Submersible Pump. Connection:1 1/2 Inch / 2 Inch, NPT Threaded Type Power Supply: 24 V DC / Output: 4- 20 mA / Display:Integral Display For Programming And Display Reading / IP 68

153

-

-

... More
Providing, Installation Testing And Commissioning Of Ultrasonic Level Transmitter: Principle : Time Of Flight /Sensor Moc: PP/ Process Connection:1 1/2 Inch / 2 Inch, NPT Threaded Type Power Supply: 24 V DC / Output: 4- 20 mA / Display:Integral Display For Programming And Display Reading / IP 68

52

-

-

... More
Providing, Installation And Commissioning of Float&Board type level Gauge for Water Level Indication at each OHT

31

-

-

... More
PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF pH METER WITH TRANSMITTER AND SENSOR MEASURING RANGE: 0-12,ACCURACY: 1%, RESOLUTION: OPERATING TEMPERATURE: 0- 50°C, installed in DMA

31

-

-

... More
Providing, Installation, Testing And Commissioning Of Turbidity Analyser For Water Application : Turbidity Measuring Range: 0 To 100 Ntu ; Accuracy:+/-2% Of Reading Or +/-0.02Ntu; With Inbuilt Transmitter With 4-20 Ma Output ,Relay Contacts & remote/GPRS Communication for Existing & Proposed WTP Location

64

-

-

... More
Chlorine Analyser : Transmitter : Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for chlorine and second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range:0.05 to 20 mg/l.

64

-

-

... More
Electrically operated Sluice valve communicable with RTU/SCADA for remotely ON & OFF: Providing, Installation, Testing And Commissioning Of Electrically operated sluice valve Confirming to respective IS, Including all Materials (Including CI/DI Fittings) and making Connection With New / existing pipeline required For Electrically operated on 415 V AC / 230 VAC sluice valve With 4-20mA Signal communication, (at Inlet of each DMA Line)

-

-

-

... More
DN80 mm

2

-

-

... More
DN125 mm

2

-

-

... More
DN150 mm

7

-

-

... More
DN200 mm

7

-

-

... More
DN250 mm

9

-

-

... More
DN300 mm

1

-

-

... More
DN350 mm

4

-

-

... More
DN450 mm

1

-

-

... More
Electrically operated Sluice valve communicable with RTU/SCADA for remotely ON & OFF: Providing, Installation, Testing And Commissioning Of Electrically operated sluice valve Confirming to respective IS, Including all Materials (Including DI Fittings) and making Connection with pipeline required For Electrically operated on 415 V AC, sluice valve With 4-20mA Signal communication, as per Technical Specification & as per direction of Employer's Representative Class PN 1.6 (with Manual wheel handle), for the following-

-

-

-

... More
DN100 mm

40

-

-

... More
DN150 mm

20

-

-

... More
DN 200 mm

15

-

-

... More
DN 250 mm

15

-

-

... More
DN 400 mm

2

-

-

... More
LCP/SWITCH BOARD FOR 3 PHASE/SINGLE PHASE ELECTRICAL POWER CONNECTION FOR FCV LOCAL POWER SUPPLY

-

-

-

... More
Metallic Box-100x100x60mm

92

-

-

... More
Power wiring-2 X 6 sq. mm + 1 X 6 sq. mm earth wire

2300

-

-

... More
MCB- 32 Amp,4P

92

-

-

... More
Enclosure for MCB

92

-

-

... More
Danger Board

92

-

-

... More
Switch-15/16 A

92

-

-

... More
Socket-6 pin 15/16 A socket outlet

92

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

60

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

600

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

400

-

-

... More
SProviding and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-.2009.

-

-

-

... More
1.5.0 Sq.mm 2 core Cu Armoured 1.1/0.750 Kv LV cable for instrument power up of voltage rating 230VAC/ 415VAC

1000

-

-

... More
0.75/1.0 Sq.mm Cu Armoured communication cable 2 Core Cable

1000

-

-

... More
0.75/1.0 Sq.mm Cu Armoured 6 Core Communication Cable

750

-

-

... More
0.75/1.0 Sq.mm Cu Armoured 12 Core Communication Cable

600

-

-

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

67

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

600

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

100

-

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.