Command Area Development Authority Tender
... More
The CADA has issued a formal invitation for competitive bids for the Command Area Development Authority project, for Solar Power Pressurized Irrigation Infrastrucure At 04 Nos. Overflowing Village Ponds Namely Gudhi, Barot, Chhapra And Gudah, Block Ladwa, District Kurukshetra. in Kurukshetra, Haryana, with an estimated contract value of Rs. 92,57,091. The bid opening date for this tender is 29-05-2026 and the last date for bid submission is 08-06-2026. Interested bidders for Command Area Development Authority tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Command Area Development Authority - CADA Tender - Haryana Tender
Opening Date29 May 2026
Closing Date8 Jun 2026
Tender Amount₹ 92,57,091
Costs
EMD
₹ 1,85,140Document Cost
₹ 5,000Tender Fee
₹ 1,000
Description
Solar Power Pressurized Irrigation Infrastrucure At 04 Nos. Overflowing Village Ponds Namely Gudhi, Barot, Chhapra And Gudah, Block Ladwa, District Kurukshetra.
Contact
Tender Id
2026_HBC_525341_1Bid Award Id
ViewTender No
202643DFDA5F 96BE 486D 884A DBCB668A82C9410CADTender Authority
Command Area Development Authority ViewPurchaser Address
-Website
http://cadaharyana.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing and fixing 12 Watt LED Street Lighting of 75 watt solar panel, 12.8 volt 30 Ah Lithium Ferro Phosphate battery, 12 Watt White LED Luminaire and Pole of 5 Meter above ground level with dusk to dawn operation {first 4 hours full light Systemding, fixing and testing of Solar light including battery: min. 24 lux) , rest of the time at lower light (50% Min. 12 lux) level} and 3 days or minimum 36 operating hours autonomy or as per direction of engineer-in-charge
16
-
-
... More
Providing fixing of Header Assembly/Manifold 3` to connenct the filtration unit (loose)
4
-
-
... More
Supply and jointing of 140 mm 6 Kg/Cm2 PE80 HDPE pipe
120
-
-
... More
providing and fixing of 3` plastic hydraulic control valve threaded (quick pressure relief)
4
-
-
... More
providing and fixing of 1.5` plastic air cum vacuum relief valve.
30
-
-
... More
providing , fixing , testing and commissioning of 2.5` Dial pressure Gauge.
8
-
-
... More
providing and fixing of 2` continuous acting air cum vacuum relief valve.
4
-
-
... More
Supply, installation, Testing and Commissioning of VFD Drive for Pumps (10 HP)
4
-
-
... More
Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminum/GI structure of suitable strength, anti-theft screws. Including lightning and surge voltage protection, fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to monitor plant performance (Amp-meter, Vold-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or equivalent IS and be mounted on fixed Aluminum/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) including suitable foundation, design and drawing shall be duly vetted from government institute including third party inspection.
41.25
-
-
... More
Supplying, erection, testing and commissioning of Solar AC Open-well Submersible Pump Set with three phase motor having casing of Alloy Steel for the required power capacity, discharge and Head including all PVC insulated polymer sheathed 3 core flat type cabling in conduit, required from solar plant to solar pump through control room. (7.5HP)
1
-
-
... More
Supplying, erection, testing and commissioning of Solar AC Open-well Submersible Pump Set with three phase motor having casing of Alloy Steel for the required power capacity, discharge and Head including all PVC insulated polymer sheathed 3 core flat type cabling in conduit, required from solar plant to solar pump through control room. (10HP)
3
-
-
... More
Providing, laying, aligning, and jointing at all level/ depths ISI marked HDPE pipe of PE 80 Grade SDR 17 PN 6 for irrigation as per IS 4984-2016 amended up to date in trenches in complete, including cost of HDPE Specials, labor, sectional hydraulic testing (including to cost of conveyance of water to site for testing ) and commissioning as per Technical Specifications and approved make as per direction of Engineer rates include cost of all specials like bends , tees required during laying of pipeline along required alignment. Dia. 140MM
120
-
-
... More
Providing, laying, aligning, and jointing with uPVC heavy body solvent at all level/ depths OF Type B , class 2(4kg/cm2) ISI marked uPVC pipe of pressure as per design for raw water supply as per IS 4985:2021 (amended up to date)including cost of special,labour,sectional hydro testing in trenches in complete, including cost of all Specials, labor, and commissioning as per Technical Specifications and approved make as per direction of Engineer. Rates includes cost of all special like bend , tees required during laying of pipe line along required alignment. 110mm uPVC Pipes
8803
-
-
... More
Providing and lowering of HDPE floater manufactured with 225 mm dia PE pipe having PE -80 and PN 10 to float the submersible open well pump / motor.
4
-
-