City Of Winnipeg Tender
Environmental Service
Canada
Details: Full Title: Professional Consulting Services For Environmental Site Assessment (esa), Decommissioning And Alternative Land Use Plan For Former Sludge Drying Beds D7. Scope Of Services D7.1 The Major Components Of The Work Identified In This Section Shall Form The Minimum Requirements And Anticipated High Level Sequence Of Work. The Proponent Is Encouraged To Review The Major Work Components And Provide Additional Information On How The Work Components Could Be Altered, Updated, Or Sequenced Appropriately As Part Of Their Proposal Submission. D7.2 Review All Applicable Information, Data, Surveys, Reports And Existing Drawings Related To The Project Including, But Not Limited To The Information Contained In This Rfp. D7.3 The Services Required Under This Contract Shall Consist The Following: (a)phase I: Complete An Environmental Site Assessment (esa)/existing Infrastructureassessment (referred To Below As ‘phase I Report’) Of The Sludge Drying Beds Site: (i)the Entirety Of This Phase Will Be Paid Out As A Fixed Price Item In Accordance Withsection B9. (ii) The Proponent Will Request And Review All Pertinent Background Reports, Operating Data, And Any Other Data The Consultant Feels Pertinent In The Background Evaluation. (iii) The Proponent Will Submit Any Specific Questions On The Sludge Drying Beds History/use To The City Project Manger To Forward On To Appropriate Staff During This Phase. (iv) The Majority Of The Work Within This Phase Is Tied To The Submission Of Phase I Report, Which Will Include The Following At Minimum: (i) The Esa Aspects Of This Report Can Be Aligned With The Requirements Of Csa-z768-01 (r2022) For Completion Of A Phase I Environmental Site Assessment, But Does Not Necessarily Need To Comply With All Requirements. The Intention To Align With Csa-z768-01 (r2022) Is To Provide A Template For The Format For The Report Deliverables. (ii) The Esa Aspects Of This Phase May Also Be Aligned With The Requirements Of Manitoba Environment & Climate’s Guideline For Environmental Site Assessments In Manitoba. (iii) The Following Items Identified Within Csa-z768-01 (r2022) Are Specifically Clarified Related To This Work: Interviews Can Occur Via Email Inquiries, Submitted To The City Project Manager As Stated In D7.1(a)(iii) Above. They Are Not Required To Be In-person Interviews. Interviews With Staff Can Occur To Confirm The Status Of Specific Infrastructure Believed To Be Decommissioning Or Still In Operation. Interviews With Staff Can Also Gather Necessary Background On The Current Operational Issues/concerns In The Use Of Existing Infrastructure. The Proponent Should Consider The Site Visit Requirements For The Purposes Of Reviewing The Entire Site Visually And Taking A Suitable Number Of Photographs To Demonstrate The Current Condition Of The Lands. This Will Be As Part Of Completing The Site Visit Component Of The Phase I Report. As Part Of The Records Review Component Of The Study, Detailed Review Of Existing Municipal Servicing Drawings Should Be Completed. This Exercise Should Result In A Detailed Infrastructure Inventory Of All Existing Infrastructure Believed To Be Currently In Operation. The Records Review Should Particularly Focus On Confirming The Extent Of Decommissioning Works Completed Through The 1990s As Part Of Decommissioning The Drying Cells, And Construction Of The Asphalt Drying Pad. (iv) The Following Requirements Will Augment The Typical Requirements Of A Phase I Esa In Accordance With Csa-z768-01 (r2022), In Order To Document The Existing Infrastructure: Cursory Statements As To The Expected Condition Of The Existing Infrastructure Is Also Be Contained In The Report. Expected Condition Is To Be Assessed Based On The Records Review, Interviews With Staff, And Basic Information Gathered From The Site Visit. All Infrastructure No Longer In Operation, But Unknown If Fully Decommissioned To Be Documented In This Report Within The Infrastructure Inventory. All Infrastructure No Longer In Operation, But Known To Be Decommissioned Based On Past Project Work To Be Documented In This Report Within The Infrastructure Inventory. All Infrastructure Supporting The Current Site Operation, Including The Decant Pump Station And The 5.5 Km Forcemain Extents (3.2km Length Prior To Tying Into The Local Wws System, And The Remaining 2.3km Segment Disconnected But Not Removed) Is To Be Included Within The Infrastructure Inventory Under Consideration. (b) Phase Ii: Complete Sampling/infrastructure Assessment Plan (i) The Entirety Of This Phase Will Be Paid Out As A Fixed Price Item In Accordance With Section B9. (ii) This Plan Is Expected To Be Drafted As A Brief Work Proposal Detailing The Extent Of Sampling And Sampling Finding Reporting, Along With Condition Assessments Or Other Site Inspections Believed To Be Beneficial Is To Be Submitted To The City Project Manager For Approval To Use The Additional Work Allowance To Fund. (iii) This Work Can Occur Concurrently With The Development Of The Phase I Report. It Is Assumed It Will Not Begin Until A Suitable Point Within The Phase I Report Development, However It Is Not Required For The Phase I Report To Be Finalized Before This Work Can Be Initiated. (i) It Should Not Be Initiated Until The Consultant Has A Fundamental Understanding The Site, Its Infrastructure Components, Land Use History, And Risks From The Desktop Assessments Associated With The Phase Report Submission. (ii) It Is Recommended The Proponent Notify The City Project Manager When They Intend To Begin Work In This Phase Within The Proposal, Should It Be Desired To Occur Concurrently With The Phase I Report Submission. (iv) The Sampling Plan Component Of This Proposal Can Be Drafted In Accordance With Csa-z769-00 (r2023) Acting As A Template. This Will Establish All Intrusive Investigations Proposed To Determine Soil And Ground Water Conditions With The Objective Of Determining The Extent Of Impacts, In Any, To Allow For The Preparation Of Remediation Options In Accordance With Phase Iv Of The Work. (v) The Extent Of Samples Completed, Along With The Overall Number Of Samples Proposed To Be Collected And Tested, Is To Be Based On The Specific Environmental Risks Identified In The Esa, Along With The Budget Available With The Additional Work Allowance. (vi) Sampling Shall Be Completed Against Appropriate Environmental Quality Guidelines Or Regulatory Requirements, As Applicable And In The Professional Judgement Of The Proponent. (i) For Example, Soil Samples Are To Be Compared Against The Ccme Soil Quality Guidelines For The Protection Of Environmental And Human Health. (ii) Specific Environmental Quality Guidelines/requirements Assumed To Be Applied Samples Collected Shall Be Documented Within The Sample Plan Of This Proposal. (vii) The Infrastructure Assessment Component Should Present A Sequence Of Tasks To Review/confirm The Condition Of Existing Infrastructure Identified In The Infrastructure Inventory. (viii) The Infrastructure Assessment Component Should Also Present Any Tasks Required To Confirm Existence Or Existing Infrastructure, Or Status Of Decommissioning Of Existing Infrastructure As Required. (ix) The Scope Of Condition Assessment Tasks Is To Be Determined By The Consultant Based On The Risks/condition Of Specific Infrastructure, The Extent Of Existing Infrastructure To Be Assessed, Along With The Budget Available Within The Additional Work Allowance. (x) The Sampling/infrastructure Assessment Plan Shall Include An Updated Safe Work Plan The Consultant Specific For The Site Sample And Infrastructure Assessment Work. (xi) The Estimated Costs For The Tasks Expected In The Sampling/condition Assessment Plan Is To Be Submitted Within The Plan, Utilizing Form P: Person Hours Utilizing Key Personnel Hourly Estimates, Along With Subconsultant Prices. (c) Phase Iii: Complete Soil Testing, Groundwater Monitoring, Or Laboratory Testing Of Samples Collected To Confirm Specific Sources Of Contamination, If Required. Site Investigations To Further Assess The Condition Of Existing Infrastructure On Site, Or To Assess The Status Infrastructure Believed To Be Decommissioned, Are Also To Be Completed In This Phase. (i) The Entirety Of This Phase Will Be Approved Utilizing Funds From The Additional Work Allowance. (ii) The Sampling/infrastructure Assessment Plan Is Expected To Be Complete Before This Phase Can Begin, As This Deliverable Will Form The Proposal For Approval To Utilize The Additional Work Allowance. Under Extenuating Circumstances Such As Seasonal Impacts On Site Investigation Activities, Portions Of This Phase May Be Initiated Or Completed Prior To The Completion Of The Sampling/infrastructure Plan. (iii) The Initiation Of This Work However Can Occur Concurrently With The Remaining Tasks Related To The Development Of The Phase I Report, Under The Condition Where The Sampling/infrastructure Assessment Plan Is Approved Prior To The Completion Of The Phase I Report. (iv) It Is Recommended The Proponent Notify The City Project Manager When They Intend To Begin This Phase Within The Proposal, Should It Be Desired To Occur Concurrently With The Phase I Report Submission. (v) The Conclusion Of This Phase Will Be The Submission Of A Technical Memorandum Which Will Include The Following At Minimum: (i) Summarize/update The Extent Of Site Sampling And Testing Completed, In Comparison To The Extent Of Work Identified In The Sampling/infrastructure Assessment Plan. (ii) Summarize/update The Extent Of Infrastructure Assessments Completed, In Comparison To The Extent Of Work Identified In The Sampling/infrastructure Assessment Plan. (iii) Identify The Results From The Site Sampling And/or Testing, Along With Results From Any On Site Inspections Or Condition Assessments. (iv) Provide An Assessment Of Findings From These Results, In Terms Of Environmental Risk Previously Assumed, Infrastructure Risks Previously Assumed, Etc. (v) Include The Sampling/infrastructure Assessment Plan As An Appendix To This Technical Memorandum. (d) Phase Iv: Complete A Decommissioning And Land Use Plan (i) The Entirety Of This Phase Will Be Paid Out As A Fixed Price Item In Accordance With Section B9. (ii) The Goal Of This Phase Of Work Will Be To Complete All Remaining Engagement With The City Project Team, And Correlate The Data Captured In The Phase I Report And Site Testing Technical Memorandum In Order To Develop The Final Decommissioning And Land Use Plan Document. (iii) A Dedicated Meeting With The Proponent’s Project Team And The City Working Group Members In Attendance Will Be Coordinated Following The Submission Of The First Draft Of This Deliverable. (iv) An Interim Submission Of The Proposed Alternative Land Use Concepts Is To Be Submitted To The City Working Group Prior To The Decommissioning And Land Use Plan First Draft. (i) This Interim Submission Will Then Be Reviewed And Discussed With Appropriate External Stakeholders As Required. (ii) Modifications To The Land Use Concepts May Also Be Proposed By City Staff To Incorporate In The Final Report. (iii) The Content Of This Interim Submission Can Be Directly Incorporated Into The Content Of Decommissioning And Land Use Plan Document. (v) The Decommissioning And Land Use Plan Document Will Include The Following At Minimum: (i) Identify All Additional Site Testing, Infrastructure Inspection, Etc. Believed To Be Necessary In The Future To Verify The Environmental Risks, Asset Condition Risks, Etc. (ii) Document All Remediation Options To Address The Assumed Environmental Risks Identified From The Esa And Site Sampling Work. (iii) Include Recommendations Of Remediation Options Based On The Professional Judgement Of The Proponent, Risk Management Approach, Cost-benefit Analysis, Or Any Other Feedback From City Staff. Specifically Identify Remediation Measures, If Any, To Improve The Surface Runoff Water Quality Such That It Can Be Classified As Stormwater Runoff In The Future. (iv) Document Additional Remediation Measures Required To Accommodate Specific Land Uses, As Required. (v) In Specific Remediation Strategies Are Not Feasible, Then This Should Be Stated. (vi) If The Runoff Can Be Classified As Stormwater And No Longer Needs To Be Conveyed To The Newpcc, A Recommended Land Drainage Servicing Plan To Tie Into The Local Stormwater Collection System Shall Be Included In The Document. (vii) Remediation Options Should Address Primarily On-site Remediation Requirements, With The Exception Of Any Environment Remediation Measures Required For The Existing Forcemain Network Servicing The Sludge Drying Beds. (viii) Develop Conceptual Engineering Assessments Of Work(s) Necessary For Decommissioning/abandoning Existing Infrastructure To Support Alternative Land Uses And/or Existing Land Use. All Infrastructure Supporting The Current Site Operation, Including The Decant Pump Station And The 5.5 Km Forcemain Extents (3.2km Length Prior To Tying Into The Local Wws System, And The Remaining 2.3km Segment Disconnected But Not Removed) Is To Be Included Within The Decommissioning Works Under Consideration. (ix) Specifically Develop Decommissioning Plans Under The Assumption That All Necessary Remediation Measures Are Completed Such That The Surface Water Quality Can Be Classified As Stormwater. (x) Develop Conceptual Engineering Assessments Of New Municipal Infrastructure Required To Support Alternative Land Uses And/or Existing Land Use. (xi) Consider New Municipal Infrastructure Needs With Respect To The Potential Expansion Of The North Perimeter Highway, And Based On The Latest Information Available Related To This Expansion. See D4.6. (xii) Conduct Any Additional Internal Engagement With Stakeholders Within The City Of Winnipeg Real Estate And Land Development Division, The Wastewater Division, And/or Winnipeg Police Service As Part Of The Development Of The Alternative Land Use Options. Include An Allowance For One (1) Meeting At Minimum With Internal Stakeholders To Raise Alternative Land Use Options And Reach Consensus On Alternative Land Use Options To Be Considered. See D9.5. (xiii) Complete Alternative Land Use Assessments Based On City Needs For The Space, And Plausible Alternative Land Uses For The Site In The Future. (xiv) Provide An Assessment Of Additional Remediation/decommissioning Requirements To Align With The Current Land Use. (xv) Develop A Aace Class 5 Capital Cost Estimates For Remaining Site Testing Recommended In Accordance With D7.1(d)(iv)(i), Along With The Recommended Site Remediation, Decommissioning, And New Infrastructure Installation Works. Where New Infrastructure Costs, Remediation Option Costs, Or Decommissioning Option Costs Vary Significantly Depending On Alternative Land Uses Identified Above, Include Capital Cost Scenarios Based On Each Land Use/decommissioning Option. Capital Cost Scenarios To Remain At A Class 5 Level Of Definition. Clearly Identify All New Infrastructure Costs, Remediation Costs, Or Decommissioning Costs Which Will Be Required Regardless Of Land Use Option, At A Class 5 Level Of Definition. Utilize The Basis Of Estimate (boe), Class Of Estimate (coe) As Part Of Submission Of This Capital Cost Estimate. See D10.7 (xvi) Compare Alternative Land Use Options, Decommissioning Approaches, Etc And Summarize Pros And Cons Of Each. Utilize The Net Present Value (npv) City Of Winnipeg Investment Planning Templates To Illustrate The Comparison Of Alternative Land Use Options, Specifically In Terms Of Costs And Benefit Impacts To The City Of Winnipeg. See D10.7 (xvii)include Deliverables Associated With D7.1(a) And D7.1(c) As Appendices To Thedocument. The Decommissioning And Alternative Land Uses Report Is Intendedto Be The Final Summary Deliverable Prepared By The Proponent. D7.3.1 Notwithstanding The Foregoing, The Consultant Is Being Engaged By The City For Its Professional Expertise; The Consultant Shall Bring To The City’s Project Manager’s Attention Any Aspect Of The City’s Standards, Manuals, Guidelines Or Templates Which The Consultant Is Of The Opinion Is Not Consistent With Good Industry Practice. D7.4 The Funds Available For This Contract Are $375,000.00. (a)within This Funds Total: (i)$50,000 Is Allocated Towards The Additional Work Allowance
Closing Soon10 Jan 2025
Tender AmountRefer Documents
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Others
United States
Details: This Pre-solicitation Notice Is Not A Request For Proposal. All
information Needed To Submit Sf330 Documents Are Contained
herein. No Additional Solicitation Package Or Technical
information Will Be Issued.
project: 544-25-125 Replace Dental Vacuum System
work Location: Wm. Jennings Bryan Dorn Va Medical Center, Columbia, Sc 29209
estimated/target Completion Period: 145 Calendar Days After Award.
construction Magnitude: Between $100,000 And $250,000.
naics: 541330 - Engineering Services
small Business Standard: $25.5 Million
set-aside: 100% Service-disabled Veteran-owned Small Business (sdvosb)
site Visits Will Not Be Arranged During This Phase.
the Anticipated Award Date Of The Proposed A-e Contract Is On Or Before September
30, 2025.
sf 330 Date Of Receipt/due Date: Interested Firms Having The Capabilities To Perform This Work Must Submit One (1) Electronic Sf 330 And Attachments (if Any) No Later Than
(nlt) 12:00 Pm (est) January 13, 2025.
***attention*** Acknowledgement E-mails Will Be Sent From The Co Upon Receipt Of A Submission. If An Acknowledgement Is Not Returned, The Firm Should Contact The Co At Christopher.jenkins@va.gov And 478-595-2794.
project Overview:
the Columbia Va Health Care System Requires A Designed Solution To Repair Or Replace The Dental Vacuum System To Include All Piping, Pumps, Vacuums, Filters, Separators, Valving, Motors, Starters, Controllers, And All Other Necessary Components To Provide A Completely New System. The Current System Is Not Functioning Properly And Believed To Be Caused By The Current Configuration, Component Locations, And Length Of Installed Vacuum Piping.
the End Result Of The Contract Is A Complete Set Of Construction Documents To Repair Or Replace The Existing Dental Vacuum System That Are Prepared For Solicitation For Construction.
sdvosb Set-aside:
this Requirement Is A 100% Set-aside For Service-disabled Veteran-owned Small Businesses Under The Authority Of 38 U.s.c. 8127(d). To Be Eligible For Award The Sdvosb You Must Be Considered Small Under The Relevant Naics Code. Sdvosb Contractors Must Be Verified And Viewable In Sba Vetcert: Https://veterans.certify.sba.gov/ Prior To Submission Of Proposal And Prior To Award Of Contract With Vaar 804.1103-70. Status As A Qualified Sdvosb Concern Is Under The Authority Of 38 Cfr Part 74 In Accordance With The Va Acquisition Regulation (vaar) Part 819. Any Person, Persons, Or Business Entity Suspected Of Misrepresenting Itself For The Purpose Of Securing A Government Contract May Be Criminally Investigated And Prosecuted For Fraud Against The United States Of America. Parties Found Misrepresenting Their Status Also Risk Debarment From Further Government Contracts. Eligibility Determination Is Performed By The Center For Veterans Enterprise (cve). Eligible Sdvosb Concerns Must Also Be Registered At The Following Websites:
system For Award Management (sam): Https://www.sam.gov
vets-4212 Federal Contractor Reporting Https://www.dol.gov/agencies/vets/programs/vets4212
important Notice: Prior To Submitting A Proposal Under This Sdvosb Set- Aside Solicitation; Offerors Must Apply For And Receive Verification From The Department Of Veteran Affairs Center For Veterans Enterprise (cve) In Accordance With 38 Cfr Part 74 And Vaar 819.70 By Submission Of Documentation Of Veteran Status, Ownership And Control Sufficient To Establish Appropriate Status. All Offerors Are Urged To Contact The Cve And Submit The Aforementioned Required Documents To Obtain Cve Verification Of Their Sdvosb Status If They Have Not Already Done So.
for A Service-disabled Veteran Owned Small Business (sdvosb) To Be Considered As A Prospective Contractor, The Firm, Including Joint Ventures, Must Be Verified And Registered In The Department Of Veteran Affairs (va) Office Of Small & Disadvantaged Business Utilization (osdbu) Sba Vetcert: Https://veterans.certify.sba.gov/ And Registered In The System For Award Management (sam) Database (www.sam.gov) At Time Of Submission Of Their Qualifications. Failure Of A Prospective Sdvosb To Be Verified By The Center For Veterans Enterprise (cve) At The Time The Sf 330 Is Submitted Shall Result In Elimination From Consideration. All Joint Ventures Must Be Cve Verified At Time Of Submission And Submit Agreements That Comply With 13cfr 125.15 Prior To
contract Award.
in Order To Assure Compliance With Far Clauses, 52.219-14 Limitations On
subcontracting (deviation 2019-01) And Vaar 852.219-10, Va Notice Of Total
service-disabled Veteran-owned Small Business Set-aside (jul 2019)
(deviation), All Firms Submitting A Sf 330 For This Pre-solicitation Notice Are
required To Indicate What Percentage Of The Cost Of Contract Performance Will Be Expended On The Concerns Employees And In Which Discipline(s) And Percentage Of Cost Of Contract Performance To Be Expended (and In What Disciplines) By Any Other Consultant/subcontractor Or Otherwise Used Small Or Large Business Entity(s). Any Consultant/subcontractor Or Otherwise Business Entity(s) Used Must Be Identified By Name, Office Location And Size/type Of Business (i.e. Sdvosb, Vosb, 8(a), Small, Large, Etc.). Failure To Provide This Information Will Deem The Firm S Sf 330 Submittal As Nonresponsive And Preclude Further Evaluation.
far Part 36.6 (brooks Act) Selection Procedures Apply. The A-e Services Listed Herein Is Being Procured In Accordance With The Brooks Act (public Law 92-582) As Implemented In Far 36.6 And Vaar 836.6. Pursuant To Far, The Firm Responding To This Requirement Must Be Permitted, By Law, To Practice The Professions Of Architecture Or Engineering And Meet All Required Qualifications For The State Of Georgia.
sf330s Shall Be Organized In The Following Order:
cover Sheet (one-page Limit)
design Team Background With Locations Of Supporting Offices (one-page Limit)
design Team Organizational Structure With Key Discipline Roles (one-page Limit)
factor 1 Specialized Experience (one Page Per Project Limit)
factor 2 - Professional Qualifications (one Page Per Resume Limit)
factor 3 Past Performance Summary Sheet (one-page Limit)
factor 4 - Capacity (one-page Limit)
factor 5 Knowledge Or Location (one-page Limit)
factor 6 Sdvosb Inclusion Statement (one-page Limit)
full Cpars/ppqs Documentation For Factor 1 Projects (20-page Limit)
additional Information (10-page Limit)
sf330s Received Out Of Sequence Will Be Viewed Negatively.
sf330 Specific Requirements:
all Sf330 Pages Shall Be Pdf Searchable For Items 1 Through 11 And Item 13. Full Cpars And Ppqs May Be Scanned.
start Each Factor Response On A New Page.
use No Less Than 11-point Font.
all Text And Images Containing Text Is Legible When Printed On 8.5 X 11 Paper. The Evaluation Board Will Not Seek Clarification Regarding Illegible Text.
primary Selection Criteria (listed In Descending Order Of Importance):
factor 1
specialized Experience (sections F, G And H): Specialized Experience And Technical Competence In The Design And Construction Period Services Will Be Required To Perform Throughout The Life Of The Contract. Projects Experience Pertains To The Types, Size, Recency, Cost, And Complexity Of Work Previously Or Currently Being Performed By The Offeror That Is Comparable To The Work Covered By This Solicitation.
page Limit One Page Per Project. Five-page Total For Factor 1. Information Provided On Additional Pages Beyond The One Page Per Project Limit Or Beyond The Five-page Total Limit Will Not Be Included With The Review.
relevant Project Experience: Submit Five (3) Projects That Meet All Criteria Shown Below.
relevant Project Type Design-bid-build Projects Involving Site Investigation, Schematic Design, Design Development, And Construction Documents. Dental Vacuum System Replacements, Renovations Of Dental Clinics That Include New Dental Vacuum Systems, And New Building Construction That Include New Dental Vacuum Systems Are Acceptable Project Types. Masterplan And Rfp Development For Design-build Contracts Will Not Be Viewed As Relevant.
relevant Project Size Systems Service Five Dental Chairs Or More.
relevant Project Recency Project Construction Must Be Complete Or Substantially Complete Within The Past Five Years Of The Solicitation Due Date. Substantially Complete Is Defined As 80% Or Greater Of The Construction Project Is Complete At The Time Of The Solicitation Due Date.
relevant Project Cost - Construction Project Cost Must Be Greater Than $75,000
relevant Project Complexity The Project Narrative Description Must Indicate Experience With All The Following Criteria:
designing Main Vacuum Systems That Include Amalgam Separators For Dental Service Lines.
designing Infection Control Risk Mitigation Plans
designing New Pump/vacuum Drive And Controller System
the Relevant Project Criteria Listed Above Is The Minimal Information Required For Acceptable Project Relevance. Additional Value Will Be Considered For Projects Which Convey Expertise With The Following Categories And Will Potentially Increase The Overall Rating For This Factor. Projects That Do Not Convey Additional Value Expertise Will Not Be Considered A Weakness. Additional Value Expertise Includes:
experience With The Submitting Firm Serving As The Prime Contractor Leading A Multi-discipline Team Through Investigative, Design, Solicitation, And Construction Period Services. These Services Must Be Documented For Each Project Narrative.
designing Hazardous Material Abatement Plans
experience With Recent Projects Intended To Support Service Line Dental Service Lines.
va Projects Showing Documented Experience With Implementing Va Design Guides And Standards From The Technical Information Library.
experience With Recent Projects Located In The Columbia, Sc, South Carolina Midlands Area, Or Adjacent Counties.
experience With Recent Projects That Include Implementing Va Cad And Bim Standards.
submissions Shall Include No More And No Less Than Three (3) Type Projects Of Recent And Relevant Government And Private Experience Projects Similar In Type, Size, Recency, And Complexity, Cost, And Experience With The Type Of Projects/competence Above.
section G Will Used To Evaluate The Prior Experience Of The Prime Firm And Any Key Subcontractors Working Together As A Cohesive Unit On The Provided Relevant Projects. An Acceptable Rating Will Be Given If All Key Disciplines Are Shown, And Each Discipline Participated With At Least One Project Listed On Section G. Proposed Design Team Members That Do Not Have Experience With Any Of The Five Submitted Example Projects As Shown In Section G Will Be Viewed Negatively.
factor 2
professional Qualifications (sections C Through E) Necessary For Satisfactory Performance Of Required Service. The Ae Shall Demonstrate They Are Able To Sign And Stamp Each Drawing By Individuals Licensed In Any State In The United States For The Key Positions Listed Below. The Design Firm And A-e Staff Representing The Project Must Be Licensed To Practice In Any State Of The United States Of America. Provide Professional License Numbers And/or Proof Of Licensure. The Evaluation Shall Consider The Specific Experience (minimum Of Five Years) And Qualifications (i.e., Education, Training, Registration, Certifications, Overall Relevant Experience, And Longevity With The Firm As Full-time Employees) Of Personnel Proposed For Assignment To The Project, And Their Record Of Working Together As A Team When Evaluating Professional Qualifications. The Lead Designer In Each Discipline Must Be Registered To Sign Drawings In Each Discipline Must But Does Not Have To Be Registered In The State Where The Project Is Located. The Licensed Professional Must Hold Current Licensure For Said Discipline To Practice In Any State Of The United States Of America. Engineer-in -training (eit) Is Not Considered A Professional Licensure.
page Limit One Page Limit Per Position Resume 8 Pages Total For Factor 2. Information Provided On Additional Pages Beyond The 8-page Limit Will Not Be Included With The Review.
resume Requirements - A Resume For Each Of These Key Positions Must Be Provided Identifying Their Specific Role, Via Section E In The Sf330. Key Positions And Disciplines Required For This Project Include, But Are Not Limited To, The Lists Of Professionals With Required Licensure And Preferred Licensure Below. An Unacceptable Rating May Be Given If Resumes Are Not Provided For All Roles Listed.
positions Requiring Professional Licensure. Not Providing The Professional Licensure Will Be Viewed Negatively And Will Not Be Compliant With The Solicitation.
architect
mechanical Engineer
electrical Engineer
fire Protection Engineer
plumbing Engineer
key Positions With Preferred Qualifications. Design Team Professionals That Have Obtained The Indicated Preferred Licensure May Be Viewed More Favorably. Not Providing The Professional Licensure Will Not Be Viewed Negatively And Will Not Reduce The Overall Rating For This Factor. Higher Value Will Be Given For Professionals With The Preferred Professional Licensure.
quality Control Manager - Either Cqm, Cqe, Lean Six Sigma Black Belt, Or Experience With Minimum Five Projects Were Served As Qc Manager.
project Manager - Project Management Professional (pmp) Certification Or More Than 10 Years Experience With Managing A/e Design Projects.
construction Cost Estimator - Aspe Certified Professional Estimator (cpe) Certification
multi-function Roles Are Allowable For The Following Positions And May Be Shown As Multi-role Positions On The Resumes:
mechanical And Plumbing Engineering.
architect, Seps Manager, Bim Manager, Interior Designer
electrical Engineer And Rcdd
project Manager And Quality Control Manager
include The Home Office Location For Each Key Discipline Identified On Each Respective Resume In Section E Block 15.
the Criteria Listed Above Is The Minimal Information Required For Acceptable Professional Qualifications. Additional Value Will Be Considered For Each Key Position And Will Potentially Increase The Overall Rating For This Factor And Shall Not Exceed The Prescribed Page Limit.
key Personnel Having Greater Than 10 Years Experience In The Practicing Field.
key Personnel With Greater Than Five Years Employment With The Proposed Design Team Firm.
va Design And Construction Experience Within The Past Five Years.
any Other Information The Design Team Wishes To Include For This Factor So Long As The Page Limit Is Not Exceeded.
factor 3
past Performance (section H): Past Performance Will Be Evaluated On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Of Work, And Compliance With Performance Schedules Along With The Firm S History Of Design Error, Omission, And/or Deficiency Claims.
past Performance Will Be Evaluated For All Projects Provided In Section F. The Contractor Performance Assessment Rating System (cpars) Database Will Be Reviewed To Evaluate The Projects That Have A Va Cpars Entry. Va Cpars Are Not Required To Be Submitted With The Sf330 Submission. However, If The Va Cpars Is Not Included With The Sf330 Submission, Then The Contract Number For The Project Must Be Submitted For Each Project Provided In Section F So Cpars Can Be Reviewed In The Database. Please Note We Are Unable To Review Any Cpars From Other Federal Agencies, Outside Of The Va.
for Any Project That Does Not Have Va Cpars Data Available, A Past Performance Questionnaire (ppq) Is Required To Be Submitted With The Sf330. If The Firm (prime Or Subcontractor) Was Not The Prime Contractor On Any Project Submit-ted In The Sf330 A Ppq Must Be Provided Listing Their Specific Role As A Subcontractor. The Ppq Should Be Rated And Signed By The Evaluator. In The Event That A Firm Does Not Receive A Requested Complete Ppq From An Evaluator Prior To The Time For Submission, The Firm Shall Submit The Partially Completed Ppq With Section 1 And The Evaluator Information In Section 2 Completed. Ensure A Poc Is Listed With The Project Title/contract Number. The Va Will Make Reasonable Attempts To Contact The Poc Upon Submission For Ppq Completion.
the Government May Also Consider Additional Performance Related Information Regarding The Firm, To Include Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. The Government Reserves The Right To Contact Any Poc Listed On A Cpars Report Or Ppq. If Appropriate, The Record Of Significant Claims Against The Firm Because Of Improper Or Incomplete Architectural And Engineering Services May Be Evaluated.
failure To Provide Requested Data, Accessible Points Of Contact, Or Valid Phone Numbers Will Result In A Firm Being Considered Less Qualified. The Information For This Factor Shall Be Provided In Section H Of The Sf 330.
for Ppqs, Please Utilize The Attached Ppq Document. Completed Ppqs Should Be Incorporated Into The Sf 330 Directly. Ppqs Should Not Be Submitted To The Vha Pcac Directly. Any Cpars And Ppqs Will Not Be Counted Towards The Page Limitations For This Submission. However, Any Narratives Provided For Past Performance In Section H Will Be Counted Toward The Page Limit.
page Limit Provide No More Than One Page Total For This Factor For The Summary Page. Full Cpars/ppq Documentation Shall Be Included On Additional Pages With The Sf330 And Will Not Count Towards The Total Page Count.
provide A Summary Page That Provides The Factor S Required Information. For Each Of The Five Projects, Provide The Following Information.
project Information (each Project For Specialized Experience)
past Performance Record Type (ppq Or Cpars)
contract Number
point Of Contact (name, Phone, Email, Job Title, Poc Role)
ae Firm Role With Project (prime Or Subcontractor)
category Ratings
provide Complete Cpars (or Ppqs If Cpars Is Not Available) For All Sample Projects After The Sf330 Factor 8 Section.
the Criteria Listed Above Is The Minimal Information Required For Acceptable Factor Compliance. Additional Value Will Be Considered For Each Additional Item Below And May Potentially Increase The Overall Rating For This Factor. Locate This Documentation After The Complete Cpars/ppq Documents. Additional Value Documentation Shall Not Exceed Five Pages.
letters Of Appreciation Or Accolades From Previous Projects
industry Recognition Or Design Awards
any Other Information The Design Team Wishes To Include For This Factor So Long As The Five-page Limit Is Not Exceeded.
factor 4
capacity (section H): The Evaluation Will Consider The Firm S Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Key Disciplines To Perform The Work In The Required Time. Provide The Available Capacity Of Key Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded By The Va, Any Federal Agency, And Private Sector During The Previous Twelve (12) Months And The Full Potential Value Of Projects Forecasted Within The Next Twenty-four (24) Months Any Current Indefinite Delivery Contracts That The Firm Has. Include The Full Potential Value Of Any Current Indefinite Delivery Contracts. Offeror Shall Clearly State Their Available Capacity Presenting Workload Percentages For The Key Disciplines And/or Team Members, Including Sub-consultants. Also, The Offeror Must Provide The Completion Percentages And Expected Completion Date For All The Va Projects Current And Forecasted. Awarded In The Previous 12 Months. Please Ensure The Capacity Applies Toward The Team/personnel Provided In The Sf330. The Information For This Factor Shall Be Provided In Section H Of The Sf330.
page Limit Provide No More Than Two Pages Total For This Factor. Information Provided On Additional Pages Beyond The One-page Limit Will Not Be Included With The Review.
include A Table That Conveys Each Key Discipline, Quantity Of Current Design Project Workload, Quantity Of Current Construction Period Service Workload, Estimated Future Design Load, Estimated Future Construction Workload, Quantity Of Current Idiq Contracts, Total Idiq Contract Capacity, Total Remaining Idiq Capacity, And Percent The Key Discipline Is Available. For Example:
key Discipline
total # Of Current Design Project Workload
# Of Current Construction Project Workload
estimated # Of Future Design Project Workload
estimated # Of Future Construction Project Workload
quantity Of Current Idiq Contracts Involved With
total Idiq Capacity All Contracts
(millions)
total Idiq Remaining Capacity
(millions)
percent Available
capacity
architect
6
7
6
7
4
$1m
$2m
45%
mechanical Engineer
4
8
3
8
2
$1m
$1
10%
add Disciplines As Required
the Criteria Listed Above Is The Minimal Information Required For Acceptable Factor Compliance. Additional Value Will Be Considered For Each Additional Item Below And May Potentially Increase The Overall Rating For This Factor. Do Not Include Additional Pages In The Additional Information Section.
providing A Narrative Conveying The Design Team S Approach On How New Work Will Merge With The Current Workload.
provide A Narrative Describing The Process Regarding Replacement Of Key Disciplines Should One Decide To Leave The Design Team.
convey How The Design Team Can Maintain Schedule If A Key Discipline Member Is No Longer Available?
any Other Information The Design Team Wishes To Include For This Factor So Long As The Page Limit Is Not Exceeded.
factor 5
knowledge Of Locality (section H). Knowledge Of The Locality, To Include Specific Knowledge Of Certain Local Conditions Or Project Site Features, Such As Geological Features, Climatic Conditions, Working With And Local Construction Methods Or Local Laws And Regulations. The Information For This Factor Shall Be Provided In Section H Of The Sf 330.
note That The Intent Of This Factor Is To Showcase A Firm S Understanding Of The Site And Locality, And Not Where The Firm Is Located, How Far Away The Firm/branch Office Is From The Site, And How They Would Travel To The Site.
page Limit Page Limit Provide No More Than One Page Total For This Factor. Information Provided On Additional Pages Beyond The One-page Limit Will Not Be Included With The Review.
provide An Individual Narrative Conveying Knowledge Of The Locality For Each Of The Following Categories:
local Conditions Or Project Site Features
climatic Conditions
geologic Features
working With And Local Construction Methods
working With Local Laws And Regulations
the Criteria Listed Above Is The Minimal Information Required For Acceptable Factor Compliance. Additional Value Will Be Considered For Each Additional Item Below And May Potentially Increase The Overall Rating For This Factor So Long As The Page Limit Is Not Exceeded. Do Not Include Additional Pages In The Additional Information Section.
experience With Seismic Designs Applicable To The Columbia, Sc Area.
any Other Information The Design Team Wishes To Include For This Factor So Long As The Page Limit Is Not Exceeded.
factor 6
use Of Service- Disabled Veteran-owned Small Businesses, Veteran-owned Small Businesses, And Other Types Of Small Businesses As Subcontractors. Offerors Shall Be Evaluated Based On Their Utilization Plans For Service- Disabled Veteran- Owned Small Businesses (sdvosbs), Veteran-owned Small Businesses (vosbs), Or Other Types Of Small Businesses. Offerors Shall Submit Qualifications For Proposed Consultants Per Other Criteria In This Solicitation.
page Limit Page Limit Provide No More Than One Page Total For This Factor. Information Provided On Additional Pages Beyond The One-page Limit Will Not Be Included With The Review.
provide A Listing Of All Consulting Firms And Business Government Certification(s). Indicate The Anticipated Percentage Of Work The Consulting Firm Will Perform.
the Criteria Listed Above Is The Minimal Information Required For Acceptable Factor Compliance. The Higher Percentage Of Certified Sdvosb Firms Included With The Design Team May Provide Additional Value And Potentially Increase The Overall Rating For This Factor So Long As The Page Limit Is Not Exceeded. Do Not Include Additional Pages In The Additional Information Section.
Closing Soon13 Jan 2025
Tender AmountRefer Documents
DEPT OF THE ARMY USA Tender
Civil And Construction...+1Drainage Work
United States
Details: The U.s. Army Corps Of Engineers (usace), Nashville District (lrn), Intends To Issue An Invitation For Bid (ifb) Solicitation For A Firm Fixed-price (ffp) Construction Contract For The Old Hickory Sewer System Replacement Project In Hendersonville, Tn.this Is A Pre-solicitation Notice. This Notice Is Being Issued For Planning And Information Purposes Only. This Notice Is Not A Solicitation, Nor Is It To Be Construed As A Commitment By The Government. The Government Will Not Pay For Any Effort Expended In Responding To This Notice, Nor Will The Government Accept Bids As A Result Of This Notice. Point Of Contact: The Primary Contract Specialist For This Solicitation Is Kenyanna Jennings, Kenyanna.l.jennings@usace.army.mil. Any Communication Regarding This Notice Should Be Made In Writing Sent Via Email And Must Identify The Solicitation Number, Company Name, Address, Phone Number And Point Of Contact.project Description: The Scope Of This Requirement Includes The Replacement Of Existing Sanitary Sewer Lines, Construction Of New Polyethylene (pe) Force Main, One (1) Lift Station In The Left Bank Area Of Old Hickory, One (1) New Lift Station In The Old Hickory Powerhouse, One (1) New Jib Crane In The Powerhouse For Pump Removal, One (1) New Flow Meter In The New Discharge Line Of The New Lift Station In The Powerhouse, And Demolition Of The Existing Wastewater Treatment Plant (wwtp) In Hendersonville, Tennessee In Sumner County. The Anticipated Period Of Performance For The Contract Is Approximately 280 Calendar Days From The Notice To Proceed. This Description Is Not Intended To Be All Encompassing And Is Subject To Change. No Solicitation Document Exists At This Time. The Plans And Specifications Will Be Available With The Solicitation Announcement. The Anticipated Release Date For The Solicitation Is On Or Around 22 January 2025. The Solicitation Will Be Posted To Both Sam.gov And Procurement Integrated Enterprise Environment (piee) Solicitation Module. Disclosure Of Magnitude Of The Construction Project: The Estimated Price Range Is Between $1,000,000 And $5,000,000.naics Code And Sba Size Standard: 237110 ? Water And Sewer Line And Related Structures Construction; $45,000,000 Type Of Set-aside: 100% Total Small Business Set- Aside System For Award Management (sam): Bidders Are Required To Be Registered In The System For Award Management (sam) Database (https://sam.gov) And Procurement Integrated Enterprise Environment (piee) At The Time A Bid Is Submitted In Order To Comply With The Annual Representations And Certifications Requirements. Registration For Piee Is Required As This Is The Only Place Bids Shall Be Submitted.additional Information: Information Regarding Usace?s Process For Settling Requests For Equitable Adjustments And Duration Goals To Achieve Definitization Of Equitable Adjustments For Change Orders Under Construction Contracts Can Be Found By Going To Https://www.usace.army.mil/business-with-us/partnering/ Then Clicking On ?view Ffp Contract Changes Playbook Here?.specific Information Pertaining To This Procurement Will Be Available In The Solicitation. The Solicitation Documents Will Be Posted On The Sam.gov Website, Https://sam.gov And Piee Solicitation Module. It Is, And Will Continue To Be, The Responsibility Of All Potential Bidders To Monitor The Sam.gov Website For Any Amendments, Updates, Responses To Industry Questions And Answers, Etc. The Government Will Not Be Maintaining A Mailing List.instructions For Submitting Electronic Bids: In An Effort To Reduce Paperwork And Cost, All Bids Shall Be Submitted Electronically Via The Solicitation Module Of Piee Suite, As Described Below. Submissions Shall Be In Adobe Pdf Format. Electronic Bid Submissions Is Required Through The Army?s Electronic File Sharing Service In Piee (https://piee.eb.mil/). The Piee Application Is Used To Send Large Files To Individuals That Would Normally Be Too Large To Send Via Email. Information Regarding How To Set Up A Vendor Registration Is Included In This Link: Https://pieetraining.eb.mil/wbt/xhtml/wbt/portal/overview/vendorregister.xhtml. On This Page, Click On The ?vendor User Registration? Doc And It Will Take You Through The Process Of Registering As A Vendor.if You Plan On Submitting A Bid, Be Sure To Select ?sol-solicitation? In The Drop-down List And Choose The ?proposal Manager? Role To Be Given The Proper Permissions. Further Training Is Available At The Following Links: Https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml - This Link Shows Information Regarding The Solicitation Application In Piee And The Different Roles Available.https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/solicitation/proposals.xhtml - This Link Is For Bidders Regarding The Proposal Manager Function And Instruction On Submitting A Bid. Pre-bid Site Visit: Tbdofferors Are Urged And Encouraged To Inspect The Site Where Services Are To Be Performed And To Satisfy Themselves Regarding All General And Local Conditions That May Affect The Cost Of The Contract Performance (far 52.237-1, Site Visit). ** All Participants Are Required To Have Personal Protective Equipment, I.e. Hard Hat, Safety Glasses, Reflective Vests, And Steel-toed Shoes Before Entering The Project Site. Attendees Who Do Not Have These Items Present At The Site Visit May Not Be Able To Participate In The Visit.an Approved Site Visit Request Form Will Be Needed For Each Individual Attendee. This Will Be The Only Site Visit For This Project. If You Miss The Scheduled Event, No Other Arrangements Will Be Made Due To Personnel And Time Restrictions.u.s. Citizens: To Register For The Pre-bid Site Visit, U.s. Citizens Must Fill Out A U.s. Citizen Site Visit Request Form And Submit To The Point-of-contacts (poc) Listed Below No Later Than Seven (7) Calendar Days Prior To The Site Visit. Foreign Nationals (fns): To Register For The Site Visit, Foreign Nationals (fns) Shall Submit A Completed Fn Site Visit Request Form And Legible Color Copies Of Two (2) Of The Following Documents: Passport (unexpired Or Expired), Certificate Of U.s. Citizenship (ins Form N-560 04 N-561), Certificate Of Naturalization (ins Form N 550 Or N-570), Unexpired Foreign Passport With I-551 Stamp Or Attached Ins Form I-94 Indicating Unexpired Employment Authorization, An Alien Registration Receipt Card With Photo (ins Form I-151 Or I-551), Unexpired Temporary Resident Card (ins Form I-688), Unexpired Employment Authorization Card (ins Form I-688a), Unexpired Reentry Permit (ins Form I-327), Unexpired Refugee Travel Document (ins- Form I571), Or Unexpired Employment Authorization Documentation Issued By The Ins Which Contains A Photograph (ins Form I-688b) To The Lrn Poc. These Documents Must Be Submitted Thirty (30) Calendar Days Prior To The Pre-bid Meeting. Exceptions Will Be Considered On A Case-by-case Basis But Will Be Limited. Both The U.s. Citizen Site Visit Request Form And The Fn Site Visit Request Form Are Provided On Sam.gov With This Notice. Only Two (2) Persons From Each Business Entity Will Be Permitted To Attend The In-person Site Visit. Any Persons Without An Approved U.s. Citizen Site Visit Request Form Or Fn Site Visit Request Form Will Be Removed From Both The Site Visit.point-of-contact: Please Submit All Site Visit Request Forms To Kenyanna Jennings At Kenyanna.l.jennings@usace.army.mil And Samantha (dani) Bautch At Samantha.d.bautch@usace.army.mil. When You Send Your U.s. Citizen Site Visit Request Form Or Fn Site Visit Request Form, Please Put ?w912p525ba001 (foreign National Or U.s. Citizen) Request Form- (your Company Name)? In The Subject Line Of The Email. Please Edit The Information In Parenthesis To Match The Request Form You Submit And Your Company Name.
Closing Date21 Jan 2025
Tender AmountRefer Documents
Department Of Agriculture Tender
Others
Philippines
Details: Description Invitation To Bid For The Procurement Of Supply And Delivery Of Liquid Nitrogen Plant Generator (phase 2) 1. The Department Of Agriculture-western Visayas, Through The General Appropriations Act Of 2024 Intends To Apply The Sum Five Million Six Hundred Forty One Thousand Four Hundred Seventy Pesos (php5,641,470.00) Being The Abc To Payments Under The Contract For Procurement Of Supply And Delivery Of Liquid Nitrogen Plant Generator (phase 2)/ib No. 2024-128 (amv). Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The Department Of Agriculture-western Visayas Now Invites Bids For The Procurement Of Supply And Delivery Of Liquid Nitrogen Plant Generator (phase 2) With The Following Specifications: Liquid Nitrogen Plant Generator (phase 2) • Lnp 40 Liquid Nitrogen Plant – Water Cooled System • (modular, Membrane Type Technology And Gifford Mcmahon Cryocooler Principle) • Liquid Nitrogen Production Rate If Complete*> 40 Liter/day (1.7 Liter/hour); 10.6 Gal/day (0.44 Gal/hour) • System Parameters Helium Pressure 200 ± 5 Psig (13.8 ± .34 Bar) @ 60 Hz 200 ± 5 Psig (13.8 ± .34 Bar) @ 50 Hz Ambient Temperature Range 45⁰f To 100⁰f (7⁰c To 38⁰c) Maximum Altitude (standard Lnp) 10,000 Ft (3000 M) • Air Compressor Flow Rate 6.3 Acfm At 175 Psig (178 Alpm At 12.1 Bar) Fad Weight 500 Lb (227 Kg) Dimension (lxwxh) 53 X 28 X 48 In (135 X 71 X 122 Cm) Duty Cycle 1/3 Horsepower 3 Electrical Rating 208/230; 460vac, 3ph, 60hz//220;380vac, 3ph, 50hz Sound Level 74 Dba @ 1 Meter • Refrigerated Air Dryer Nominal Capacity 15 Scfm (425 Slpm) Weight 44 Lb (20 Kg) Dimensions (lxwxh) 18x8x18 In (46x20x46cm) Power Consumption 0.23 Kw Electrical Rating 115vac, 1ph, 60hz; 230vac, 1ph, 50hz • Water Chiller (orion Machinery Co Ltd) Model: Rke370b-v-g1 Cooling Capacity: 12.2kw Operating Ambient Temperature: -20 To 45 Deg C Operating Temperature Range: 3 To 35 Deg C Control Currency: +/- 0.1 Deg C (during Periods Of Stable Load: +/- 0.5 Deg C Power Consumption: 5.4kw Electric Current: 16.5 Amp Power Capacity: 7.0kva Breaker Capacity: 30 Amps Compressor Output: 1.7kw Condenser: Fin And Tube Forced Air Cooling Heat Exchanger: Plate Type Heat Exchanger Material: Sus 316 Grade Stainless Steel (brazing: Cu) Discharge Pump Output: 1.1 Kw – Inverter Controlled Flow Rate Discharge: 15-60 L/min Fan Motor Output: 0.4kw – Inverter Controlled Water Tank Capacity – Approx.60l Operations Method: Compressor Speed Control Refrigerant: R410-a • Service Kits: Installation Tool Kit Installation Spare Parts Kit Installation And Operations Manual Term And Conditions: • With 1 Year Warranty And Technical Support/guidance After Full Delivery Is Included Delivery Of The Goods Is Required Within 90 Calendar Days From Receipt Of Notice To Proceed And To Be Delivered At Da - Iloilo Research Outreach Station, Sta. Barbara, Iloilo. Bidders Should Have Completed, Within Three (3) Years (2021-present) From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. The Prospective Bidder Must Be Registered In The Philgeps. 4. Prospective Bidders May Obtain Further Information From Department Of Agriculture - Visayas And Inspect The Bidding Documents At The Address Given Below During Office Hours, 8:00 A.m. To 5:00 P.m. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On December 30, 2024 – January 22, 2025 From The Given Address And Website(s) Below And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of Five Thousand Pesos (php5,000.00). The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees To Be Presented In Person. 6. The Department Of Agriculture-western Visayas Will Hold A Pre-bid Conference At 9:30 A.m. On January 8, 2025 At The Rcpc Library, Rcpc Building, Da Wesviarc Compound, Brgy. Buntatala, Jaro, Iloilo City, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Below On Or Before 9:30 A.m. On January 22, 2025. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Securing Declaration Or Bid Security In The Amount Of Any Of The Acceptable Forms And In The Amount Of Php112,829.40 (if The Bid Security Is In The Form Of Cash, Cashier’s/manager’s Check, Bank Draft/guarantee Or Irrevocable Letter Of Credit) Or Php282,073.50 (if The Bid Security Is In The Form Of Surety Bond). In Lieu Of A Bid Security, The Bidder May Submit A Duly Notarized Bid Securing Declaration That Is An Undertaking Which States, Among Others, That The Bidder Shall Enter Into Contract With The Procuring Entity And Furnish The Required Performance Security Within 10 Calendar Days From Receipt Of The Notice Of Award, And Committing To Pay The Corresponding Fine And Be Suspended For A Period Of Time From Being Qualified To Participate In Any Government Procurement Activity In The Event That It Violates Any Of The Conditions Stated Therein As Required In The Guidelines Issued By The Gppb. 9. Bid Opening Shall Be At 9:30 A.m. On January 22, 2025 At The Given Address Below. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. The Department Of Agriculture-western Visayas Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. The Department Of Agriculture-western Visayas Does Not Condone Any Forms Of Solicitation On Any Prospective Winning And Losing Bidders By Any Of Our Staff/employees Or Any Other Party. Any Sort Of This Kind Shall Be Reported Immediately To The Office Of The Secretary Or The National Bureau Of Investigation (nbi) For Entrapment And Proper Investigation. 12. For Further Information, Please Refer To: Zarlina B. Cuello Bac Chairperson Da-wesviarc Compound Brgy. Buntatala, Jaro, Iloilo City Tel. No. (033) 320-23-73 Www.westernvisayas.da.gov.ph Procurement@wv.da.gov.ph 13. You May Visit The Following Websites: For Downloading Of Bidding Documents: Philgeps December 30, 2024 Zarlina B. Cuello Bac Chairperson
Closing Date22 Jan 2025
Tender AmountPHP 5.6 Million (USD 97.2 K)
DEPT OF THE NAVY USA Tender
Others
Corrigendum : Closing Date Modified
United States
Description: Item Unique Identification And Valuation (jan 2023)|19||||||||||||||||||||
inspection Of Supplies--fixed-price (aug 1996)|2|||
inspection And Acceptance - Short Version|8|x||x||||||
stop-work Order (aug 1989)|1||
wide Area Workflow Payment Instructions (jan 2023)|16|see Schedule|n/a|tbd|n00104|tbd|tbd|w25g1u|tbd|n/a|n/a|tbd||||||
monetary Limitation Repair Purchase Orders|1|7,235.00|
navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|wss|
transportation Of Supplies By Sea (oct 2024)|2|||
alternate A, Annual Representations And Certifications (oct 2024)|13||||||||||||||
annual Representations And Certifications (may 2024)|13|332710|500||||||||||||
notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2|x||
1.this Requirement Is Pursuant To Emergency Acquisition Flexibilities (eaf).
2.the Resultant Award Of This Solicitation Will Be Issued Bilaterally, Requiring The Contractor's Written Acceptance Prior To Execution.
3.all Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders, Delivery Orders, And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By
facsimile, Or Sent By Other Electronic Commerce Methods Such As Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Herein.
4.if Requirement Will Be Packaged At A Location Different From The Offeror's Address, The Offeror Shall Provide The Name, Street Address, And Cage Of The Facility.
5.any Contract Awarded As A Result Of This Solicitation Will Be Do Certified For National Defense Under The Defense Priorities And Allocations System (dpas). Provision 52.211-14, Notice Of Priority Rating For National Defense, Emergency Preparedness, And Energy
program Use, Shall Be Inserted In Solicitations When The Contract To Be Awarded Shall Be A Rated Order.
6.if Drawings Are Included In The Solicitation, Access Needs To Be Requested On The Individual Solicitation Page Under Contract Opportunities On Sam.gov Website. After Requesting Access, Send An Email To The Poc Listed On The Solicitation.
7.please Provide Repair Price As Estimated (est) For The Full Repair Effort Of The Requirement.
8.vendor Shall Have 90 Days After Receipt Of Carcass(es) To Complete A Teardown & Evaluation (td&e) Of The Carcass(es) And Submit A Firm-fixed Price (ffp) Quote For The Full Repair Effort Of The Carcass(es).
9.when Submitting A Quote, Please Include The Cost Of New (actual Or Estimated) For Evaluation Purposes.
10.quote Shall Specify Any Exceptions Including But Not Limited To Mil-std Packaging, Mil-std Labeling, Inspection & Acceptance Locations, Packaging House, Surplus Materials, Etc. If No Exceptions Are Indicated Or Received, Award Shall Be Based Upon Solicitation
requirements. Changes Or Requests For Changes After Award Shall Be Subject To Consideration Costs Deducted From The Unit Price.
11.in Repair Price, Include All Costs Associated With Receipt And Complete Repair Of Material That May Be In Unwhole Condition, Missing Hardware, Damaged, Handling Damage, Missing Parts, Wear Damage, And Cav Reporting. Also Provide The Following Information:
a.teardown & Evaluation Rate:
b.repair Turn Around Time (rtat):
c.throughput Constraint:
d.induction Expiration Date:
12.price Reductions
a.any Asset For Which The Contractor Does Not Meet The Required Rtat Will Incur A Price Reduction Of Xxxx Per Unit. This Adjustment Will Be Implemented Via A Reduction Modification At The End Of Contract Performance. Price Reductions Made Pursuant To This Section
shall Not Limit Other Remedies Available To The Government For Failure To Meet Required Rtats, Including But Not Limited To The Government's Right To Terminate For Default.
13.the Contractor Must Obtain Final Inspection And Acceptance By The Government For All Assets Within The Rtat Established In The Resulting Contract.
a.requested Rtat: 80 Days
14.quotes Shall Reference The Proposed Rtat And Any Capacity Constraints.
\
this Requirement Has Been Updated From 3r To 2g.
all Other Terms And Conditions Remain The Same.
\
teardown And Evaluation Only Quotes Will Not Be Accepted. Induction Expirationdate: 120 Days After The Date Of Subsequent Award. Any Assets Recieved Afterthis Date In Days Is Not Authorized To Be Repaired Without Bi-lateralagreementbetween The Vendor And
contracting Officer. If Firm-fixed Repairpricing Isprovided, Beyond Economical Repair (ber) Does Exist. With Dcma Concurrence,beyond Repair (br) Is Possible. If Unit Is Determined Br, The Unit Price Willbe Negotiated Downward From The Awarded Firm-fixed Repair
price.
unless Otherwise Specified, Pricing For This Quotation Is Valid For 90 Days After The Closing Date As Indicated On The Quotation. Please Specify (if Other Than 90 Days) _________ Days.
if You Are Submitting Your Quote Via Email Or Neco, Please Specify The Number Of Days Pricing Is Valid.
all Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders,delivery Orders And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By Facsimile, Or
Sent By Other Electronic Commerce Methods,
1. Scope
1.1 This Contract/purchase Order Contains The Requirements For Repair And The Contract Quality Requirements For The Stand,maintenance,a .
1.2 Government Furnished Material - Government Furnished Material Is Available. The Material And Quantities Are As Follows: ;prior To Delivery Of Any Unit, With Exception Of A Fa Unit, Thecontractor Must Perform A Manufacturer's Proof Test On Each Engine
housing Maintenance Stand Assembly. The Manufacturer's Proof Test Requirement Isdefined In Drawing 53711-7052553 And Includes Use Of Government Furnished Material (gfm), Engine Housing Stand Test Weight (53711-8667274).the Gfm Test Weight For Proof
testing Can Be Obtained From Naval Underseawarfare Center Division Newport, Newport, Ri 02841-1708. Requests Can Beemailed To Nwpt_nuwc_npt_8554_torpmtrlrqst@navy.mil. The Weight Test Plate,when Filled Out Completely As Described In
note 3 Of Drawing 53711-7052553,serves As Objective Quality Evidence (oqe) For Completion Of This Test.;
.
2. Applicable Documents
2.1 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions.
2.1.1 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order.
drawing Data=6301669 |53711| A|fn |d|0001 | A|49998|0112700
drawing Data=6301669 |53711| A|pl |d|0001 | A|49998|0022283
drawing Data=6301669 |53711| A|pl |d|0002 | A|49998|0032676
drawing Data=7052526 |53711| B|fn |d|0001 | |49998|0022325
drawing Data=7052553 |53711| H|fn |d|0001 | |49998|0168695
drawing Data=7052553 |53711| H|pl |d|0001 | |49998|0012642
drawing Data=7052553 |53711| H|pl |d|0001.0002 | A|49998|0036978
drawing Data=7052554 |53711| A|fn |d|0001 | A|49998|0081004
drawing Data=7052554 |53711| A|fn |d|0002 | -|49998|0039263
drawing Data=7052574 |53711| C|fn |d|0001 | |49998|0720658
drawing Data=7052574 |53711| B|pl |d|0001 | |49998|0009092
drawing Data=7052574 |53711| B|pl |d|0001.0002 | A|49998|0027928
drawing Data=7052605 |53711| G|fn |d|0001 | |49998|0019343
drawing Data=7052674 |53711| B|fn |d|0001 | |49998|0028045
drawing Data=7052681 |53711| E|fn |d|0001 | |49998|0055962
drawing Data=7052682 |53711| C|fn |d|0001 | |49998|0023328
drawing Data=7052683 |53711| D|fn |d|0001 | |49998|0135611
drawing Data=8243462 |53711| D|fn |d|0001 | D|49998|0048512
drawing Data=8243463 |53711| D|fn |d|0001 | D|49998|0048452
drawing Data=8475682 |53711| -|fn |d|0001 | -|49998|0050234
drawing Data=8667456 |53711| | |d|0001 | |49998|0410681
drawing Data=8667457 |53711| A| |d|0001 | |49998|0111686
drawing Data=8667457 |53711| A|pl |d|0001 | |49998|0027661
drawing Data=8667540 |53711| | |d|0001 | |49998|0151055
document Ref Data=mil-std-129 | | |r |180524|a| |01|
3. Requirements
3.1 Cage Code/reference Number Items - The Stand,maintenance,a Repaired Under This Contract/purchase Order Shall Meet The Operational And Functional Requirements As Represented By The Cage Code(s) And Reference Number(s) Listed Below. All Repair Work Shall
be Performed In Accordance With The Contractors Repair/overhaul Standard Practices, Manuals And Directives Including But Not Limited To Drawings, Technical Orders, Manufacturing Operations, Tooling Instructions, Approved Repair Standards And Any Other
contractor Or Government Approved Documents Developed To Provide Technical Repair Procedures.
cage___ref. No.
;53711 7052553;
3.2 Marking - This Item Shall Be Physically Identified In Accordance
with ;mil-std-129; .
3.3 Changes In Design, Material Servicing, Or Part Number - Except For A Code 1 Change, Which Shall Be Processed As Provided In The Code Statement Shown Below, No Substitution Of Items Shall Be Made Until The Navicp-mech Contracting Officer Has Notified And
approval Has Been Given By Issuance Of A Written Change Order. When Any Change In Design, Material, Servicing Or Part Number Is Made To Replace Or Substitute Any Item To Be Furnished On This Contract/purchase Order, The Contractor Shall Furnish, For The
substituting/replacement Item, A Drawing And An Explanation Of The Reason For The Change, Explaining The Reason Therefor. If Finished Detail Drawings Are Not Available, Shop Drawings In The Form Used By The Manufacturer Will Be Acceptable For Government
evaluation. When Notifying The Procurement Contracting Officer Of The Reasons For Making Substitutions, The Type Of Change Shall Be Indicated By Code Number In Accordance With One Of The Following Statements:
code 1: Part Number Change Only - If The Manufacturer's Part Number Indicated Thereon Has Changed, But The Parts Are Identical In All Respects, Supply The Item And Advise Navicp-mech Immediately Of The New Part Number.
code 2: Assembly (or Set Or Kit) Not Furnished - Used Following Detail Parts.
code 3: Part Not Furnished Separately - Use Assembly.
code 4: Part Redesigned - Old And New Parts Are Completely Interchangeable.
code 5: Part Redesigned - New Part Replaces Old. Old Part Cannot Replace New.
code 6: Part Redesigned - Parts Not Interchangeable.
3.4 Mercury Free - The Material Supplied Under This Contract/purchase Order Is Intended For Use On Submarines/surface Ships And Therefore Shall Contain No Metallic Mercury And Shall Be Free From Mercury Contamination. Mercury Contamination Of The Material
will Be Cause For Rejection.
If The Inclusion Of Metallic Mercury Is Required As A Functional Part Of The Material Furnished Under This Contract, The Contractor Shall Obtain Written Approval From The Procurement Contracting Officer Before Proceeding With Manufacture. The
contractor's Request Shall Explain In Detail The Requirements For Mercury, Identify Specifically The Parts To Contain Mercury, And Explain The Method Of Protection Against Mercury Escape. Such A Request Will Be Forwarded Directly To The Procurement Contracting
officer With A Copy To The Applicable Government Inspector. Upon Approval By The Contracting Officer, The Vendor Will Provide A "warning Plate" Stating That Metallic Mercury Is A Functional Part Of The Item And Will Include Name And Location Of That Part.
The Use Of Mercury, Mercury Compounds, Or Mercury-bearing Instruments And/or Equipment In A Manner Which Might Cause Contamination In The Manufacture, Assembly, Or Test Of Material On This Contract Is Prohibited. The Most Probable Causes Of
contamination Are Direct-connected Manometers, Mercury Vacuum Pumps, Mercury Seals, Or The Handling Of Mercury In The Immediate Vicinity. Mercury Switches, Mercury In Glass Thermometers, Standard Cells And Other Items Containing Mercury May Be Used If They Are
located So As Not To Constitute A Contamination Hazard.
If External Contamination By Metallic Mercury Occurs Or Is Suspected, The Following Test May Be Used To Determine Whether Contamination By Metallic Mercury Exists Or Whether Corrective Cleaning Measures Have Been Effective. Enclose The Equipment In A
polyethylene Bag Or Close-fitting Airtight Container For Eight Hours At Room Temperature (70 Degrees F Minimum).sample The Trapped Air And If Mercury Vapor Concentration Is 0.01 Mg/cu Meter Or More, The Material Is Mercury Contaminated Insofar As The
requirements Of This Contract Are Concerned.
These Requirements Shall Be Included In Any Subcontract Or Purchase Order Hereunder And The Contractor Shall Insure Subcontractor Compliance With These Requirements.
Technical Questions Pertaining To These Requirements Shall Be Referred To The Procurement Contracting Officer Via The Cognizant Administrative Contracting Officer. For Background, The Following Information Is Provided:
Mercury Is Corrosive To Gold, Silver, Nickel, Stainless Steels, Aluminum And Copper Alloys. Stainless Steels, Nickel, And Copper Alloys Are Widely Used In Reactor Plants And Other Submarine/surface Ship Systems. Accidental Trapping Of Mercury In A
component Could Cause Serious Damage To Vital Parts. Mercury Is Also Toxic If Inhaled, Ingested, Or Absorbed Through The Skin. It Is Evident That Grave Consequences Could Result From Small Amounts Of Mercury Vapor Present In An Unreplenished Submarine/surface
ship Atmosphere.
3.5 First Article Approval (government Testing) - First Article Test (fat) And Approval Is Required.
3.6 Serialization - The Supplier Shall Mark A Serial Number On Each Stand,maintenance,a In Accordance With ;iaw Dwg 7052553 Rev "h" Note 13.;
. Actual Serial Numbers Will Be Assigned ;apply A Goverment Serial Number To Each Unit Manufactured. Serial Number Shall Be Obtained From Commander, Naval Undersea Warfare Center Division Newport, Newport, Ri 02841-1708. Requests Can Be Made To
nuwc_npt_serialnumbers@navy.mil.;
.
3.7 Serialization - The Supplier Shall Mark A Serial Number On Each Stand,maintenance,a In Accordance With ;iaw Dwg 8667456 Rev "-" Note 9.;
. Actual Serial Numbers Will Be Assigned ;apply A Goverment Serial Number To Each Unit Manufactured. Serial Number Shall Be Obtained From Commander, Naval Undersea Warfare Center Division Newport, Newport, Ri 02841-1708. Requests Can Be Made To
nuwc_npt_serialnumbers@navy.mil.;
.
3.8 ;a First Article (fa) Sample Is Required If The Contractor/supplier Has Not Manufactured This Item Before (or Has Not Done It In A Long Time).for Fa, One (1) Preproduction Sample, Here In After Referred To As The Fa, Shall Be Inspected And Tested By The
government Prior To Proceeding With Production Of Any Additional Units. The Fa Shall Be Fully Representative Of Those Proposed For Production And Demonstrate The Adequacy And Suitabilityof The Contractor's Processes And Procedures In Complying With There
quirements Set Forth By The Engine Housing Maintenance Stand Assembly Technical Documentation. Acceptance Of The Fa Is Required Prior Toproceeding With Production Of Additional Units. The Government Will Be Responsible For Performing Fa Inspection, Testing And
acceptance. The Fa Shall Not Be Previously Load Tested. All Tests Will Be Performed Atan Ambient Temperature Of 77 � 18� Fahrenheit With Ambient Humidity. The Naval Undersea Warfare Center Division Newport Will Prepare A Written Test Report At The Conclusion Of
fa Inspection And Testing. Once A Contractor Has An Accepted Fa, The First Article Submission Requirementmay Be Waived Thereafter.;
3.9 Marking - This Item Shall Be Physically Identified In Accordance With Mil-std-130.
3.10 ;packaging And Packing.
unless Otherwise Specified In The Contract Or Purchase Order, Each Engine Housing Maintenance Stand Assembly Shall Be Prepared For Shipment Inaccordance With Mil-std-2073-1, Method 10. One Engine Housing Maintenance Stand Assembly Shall Be Packed By Pallet Or
wooden Box. Blocking Andbracing Of The Box Shall Be Performed To Restrict The Engine Housingmaintenance Stand Assembly Movement Within The Wood Box. The Wood Box Shallbe Of Nailed And Locked Corner Construction (formerly Ppp-b-621, Class 1,style 4, Grade B).
the Box Shall Have Full Cleated Ends And Butt Joints.the Thickness Of The Wood Members Shall (as A Minimum) Be In Accordancewith Table 1.
table 1 - Wood Thickness:thickness Of Sides Inch Top And Bottom: 1/2 Inch; Ends: 5/8 Inch;thickness And Width Of Cleats: 5/8 X 3 Inches
nails Shall Be Placed So As Not To Intrude On The Interior Space Ofthe Box. The Box Shall Accommodate One Complete Engine Housing Maintenancestand Assembly. The Box Shall Be Banded Using Two Straps Conforming Toastm D3953, Type 1 (flat Strapping Regular Duty),
finish B, Grade 3(galvanized Commercial Coating).
marking.
in Addition To Any Special Marking Required By The Contract Or Purchase Order, The Wood Box Shall Be Marked In Accordance With Mil-std-129. As A Minimum,the Box Shall Contain The Following Information:
example: The Below Information Is For Example Purposes Only.
p/n 7516900
nomenclature: Beam, Lifting, Mk 99 Mod 0
nsn 1450-01-123-4567
1 Each
n08861-08-c-1001
156 Lbs
s/n 123
;
3.11 ;item Unique Identification (iuid).
defense Procurement And Acquisition Policy Requires Serial Number Registration For The Engine Housing Maintenance Test Stand Assembly. Data Submission And Policy Requirements Are Found In The Following Websites:
https://www.acq.osd.mil/asda/dpc/ce/ds/unique-id.html And Https://piee.eb.mil/.;
4. Quality Assurance
4.1 Responsibility For Inspection - Unless Otherwise Specified In The Contract/purchase Order, The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified Herein. Except As Otherwise Specified In The Contract/purchase Order,
the Contractor May Use His Own Or Any Other Facilities Suitable For The Performance Of The Inspection Requirements Specified Herein, Unless Disapproved By The Government. The Government Reserves The Right To Perform Any Of The Inspections Set Forth In The
specification Where Such Inspections Are Deemed Necessary To Assure Supplies And Services Conform To Prescribed Requirements.
4.2 Inspection/testing Repaired Items - The Contractor Shall Perform All Inspection And Testing Requirements As Specified In The Original Manufacturer's Specifications And Drawings.
4.3 Records - Records Of All Inspection Work By The Contractor Shall Be Kept Complete And Available To The Government During The Performance Of Contract/purchase Order And For A Period Of 365 Calendar Days After Final Delivery Of Supplies.
4.4 First Article Test/inspection (government) - The Contractor Shall Deliver ;1 Unit;
unit(s) To ;receiving Officer, Naval Station Newport47 Chandler St.newport, Ri 02841-1716 Mark For: Navunseawarcendiv Newport, Code 8524;
for First Article Tests In Accordance With The ;iaw The Schedule Provided By The Contract.
dwg 7052553 Rev "h" Note 4 "d".
a First Article Sample Is Required When Specified In The Contract. Acceptance Will Be Based On Conformance To The Requirements Of This Drawing.;
.
4.5 First Article Test/inspection Report - The Contractor Shall Prepare And Submit A Report In Accordance With The Contract Data Requirements List (dd Form 1423). The Report Shall Be Approved Prior To Production.
4.6 ;supplemental Quality Assurance Provisions:
a. Due To The Critical Application Of This Part That Includes Personnel Safety,it Is Recommended That The Critical/major Characteristics And Key Features Of Thepart, Identified Below, Be Emphasized When Communicating With The Contractor/supplier
b. Government Source Inspection:
drawing 7052553 (engine Housing Maintenance Stand Assembly) Key Features:
1. Note 1 On Drawing Is A Critical Characteristic (c1)
2. Note 3 On Drawing Is A Major Characteristic (m101)
3. Note 7 On Drawing Is A Key Feature
4. Note 13 On Drawing Is A Key Feature
5. Note 14 On Drawing Is A Key Feature
drawing 7052554 (base Assembly) Key Features:
1. Note 8 On Drawing Is A Key Feature
drawing 8667456 (clamp Machining) Key Features:
1. Note 7 On Drawing Is A Key Feature
2. Note 8 On Drawing Is A Key Feature
3. Note 9 On Drawing Is A Key Feature
4. Note 10 On Drawing Is A Key Feature
5. Note 11 On Drawing Is A Critical Characteristic (c1)
6. Note 13 On Drawing Is A Major Characteristic (m101)
drawing 8667540 (swivel Caster) Key Features:
1. This Is A Source Control Drawing With One Approved Source Of Supply Listed O
drawing 7052681 (horizontal Stop) Key Features:
1. Note 7 On Drawing Is A Key Feature
2. Note 8 On Drawing Is A Key Feature
drawing 7052682 (vertical Stop) Key Features:
1. Note 1 On Drawing Is A Key Feature
drawing 7052526 (toggle Clamp Mounting Plate) Key Features:
1. Note 2 On Drawing Is A Key Feature
drawing 7052683 (locator) Key Features:
1. Note 2 On Drawing Is A Key Feature
drawing 7052605-7 (identification Plate) Key Features:
1. Note 3 On Drawing Is A Key Feature:
drawing C49667 (hand Wheel) Key Features:
1. Note 2 On Drawing Is A Key Feature
drawing B49671 (bearing Shaft) Key Features:
1. Note 3 On Drawing Is A Key Feature
drawing C49672 (bearing Block) Key Features:
1. Note 3 On Drawing Is A Key Feature;
5. Packaging
5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Shall Be In Accordance With The Contract/purchase Order Schedule And As Specified Below.
mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule
6. Notes
6.1 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss)
(i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. Most Specifications Can Obtained Directly From Http://quicksearch.dla.mil/
a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documentsthat Are Required By Private Industry In Fulfillment Of Contractual Obligationsin Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk.
b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. Theymay Be Obtained From The Publishers Of The Applicable Societies.
c. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To:
commander, Indian Head Division, Naval Surface Warfare Center
code 8410p, 101 Strauss Avenue
indian Head, Md 20640-5035
d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contractnumber, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For
certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document.
e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From:
contracting Officer
navsup-wss
code 87321
5450 Carlisle Pike
p.o. Box 2020
mechanicsburg, Pa. 17055-0788
f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered Enue:
commanding Officer
navsup-wss
code 009
5450 Carlisle Pike
p.o. Box 2020
mechanicsburg, Pa. 17055-0788
g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From:
commanding Officer
navsup-wss
code 1 Support Branch
700 Robbins Avenue
philadelphia, Pa. 19111-5094
h. Interim Changes And Classified Specifications Must Be Obtained By Submitting A Request On Dd Form 1425 To Navsup-wss.
6.2 Notice To Distributors/offerors - Consideration For Award Of Contract Shall Be Given Only To Authorized Distributors Of The Original Manufacturer's Item Represented In This Solicitation. If You Desire To Be Considered As A Potential Source For Award Of
this Contract, Proof Of Being An Authorized Distributor Shall Be Provided On Company Letterhead Signed By A Responsible Company Official And Sent With Your Offer To The Procurement Contracting Officer.
6.3 In Accordance With Opnavinst 5510.1 All Documents And Drawings Provided By The U.s. Navy To Perspective Contractors Must Include A "distribution Statement" To Inform The Contractor Of The Limits Of Distribution, And The Safeguarding Of The Information
contained On Those Documents And Drawings.
There Are 7 (seven) Seperate Distribution Statement Codes Used For Non-classified Documents And Drawings. The Definition For Each Is As Follows:
a... Approved For Public Release; Distribution Is Unlimited.
b... Distribution Authorized To Us Governments Agencies Only.
c... Distribution Authorized To Us Government Agencies And Their Contractors.
d... Distribution Authorized To Dod And Dod Contractors Only.
e... Distribution Authorized To Dod Components Only.
f... Further Distribution Only As Directed By Commander, Naval Sea
Systems Command, Code 09t.
x... Distribution Is Authorized To Us Government Agencies And Private Individuals Or Enterprises Eligible To Obtain Export Controlled Technical
Data In Accordance With Opnavinst 5510.161.
6.4 ;for Contracting:
quality Assurance Provisions (qaps) For Dwg 7052553 Can Be Found On S:
mech
navicp
icpm
wss General Shares
n97 General Shares
n9713 Technical
torpedo (qaps) Quality Assurance Provisions;
date Of First Submission=030 Dac
;certificate Of Quality Compliance (coqc).
a Certificate Of Quality Compliance For Drawing 53711-7052553 Note 1 Manufacturer Proof Test Results For Each Unit Shall Be Delivered To The Government Via Contract Data Requirements List (cdrl).
Note 1. Manufacturer's Proof Test: Using The Test Configurations Shown In Figures 1 And 2, Each Engine Housing Maintenance Stand Assembly Shall Withstand A Static Load Test Of 684
(+34/-0) Lbs For A Minimum Of Two Minutes In The Vertical Direction And Two Minutes In The Horizontal Direction. Failure Or Permanent Deformation Of Any Part Shall Be Cause For Rejection. Copies Of The Certificate Of Quality Compliance Cdrl Shall Be Delivered To
the Engineering Support Activity, Nuwc Newport:
nwpt.nuwc_8554_qapcdrl@navy.mil
james.c.ferguson1.civ@us.navy.mil
richard.d.penfold2.civ@us.navy.mil
patrick.r.faerber.civ@us.navy.mil
recommend A Post Award Conference Be Conducted With The Contractor/supplier To Review The Item Key Features. The Government Engineeringsupport Activity, Nuwc Newport, Would Like To Participate In Theconference If One Is Scheduled.
;
Closing Soon14 Jan 2025
Tender AmountRefer Documents
DEPT OF THE ARMY USA Tender
Civil And Construction...+2Consultancy Services, Civil And Architectural Services
United States
Details: This Sources Sought Notice Is Being Issued For Market Research Purposes To Determine The Availability, Capability, And Interest Of Small Business Firms For A Potential Government Requirement. No Solicitation Is Available; Requests For A Solicitation Will Go Unanswered. No Award Will Be Made From This Notice. Responses Will Be Used To Determine Potential Acquisition Strategies, Understand Current Market Capabilities, And To Gain Knowledge Of Potential Sources.
general Scope:
the United States Army Corps Of Engineers (usace) Sacramento District (spk) Anticipates A Potential Requirement For A-e Vertical Design Services In Support Of The South Pacific Division’s Military, Interagency And International Services (iis), And Civil Works (cw) Projects.
the Potential Requirement May Result In A Firm-fixed-price Solicitation Issued Approximately October 2025. If Solicited, The Government Intends To Procure These Services In Accordance With The Selection Of Architects And Engineers Statute As Implemented In Far Subpart 36.6.
if The Requirement Is Solicited, Firms Will Be Selected For Negotiation Based On Demonstrated Competence And Qualifications For All The Required Work. The Government May Issue Five Or More Firm-fixed-price (ffp) Indefinite Delivery Indefinite Quantity (idiq) Contracts Within The Five-year Period. The Combined Capacity Is Estimated At $499,000,000.00.
the North American Industrial Classification System (naics) Code For This Potential Requirement Is Anticipated To Be 541330, Engineering Services. The Small Business Size Standard For This Naics, As Established By The U.s. Small Business Administration, Is $25,500,000 Annual Revenue. The Product Service Code (psc) For The Potential Requirement Is Anticipated To Be C219, Architect And Engineering- General: Other.
projects Will Primarily Locate Within The Area Of Responsibility (aor) Of Usace South Pacific Division (spd) But May Be Used At Conus Locations If Determined Within Scope Of The Contract By The Contracting Officer. Spd’s Civil Works Boundaries Generally Include Ca, Nv, Az, Ut, And Portions Of Or, Id, Co, Tx And Wy. Military/iis Boundaries Generally Include Ca, Nv, Ut, Nm, And Az. This Regional Acquisition Tool Will Be Used By Any District Within Spd (sacramento, San Francisco, Los Angeles, And Albuquerque Districts) To Encompass The Entire Spd Geographical Aor For All Programs. A Specific Scope Of Work And Services Will Be Issued With Each Task Order.
all Interested Firms Are Encouraged To Respond To This Notice And May Respond To This Announcement By Submitting A Capabilities Statement Which Addresses The Following Key Areas:
the Primary Focus Of This Contract Is To Provide Vertical Design Services In Support Of The Spd Military, Iis And Civil Works Programs. The Design Services Could Range From An Architectural Renovation (some Of Historical Significance), Maintenance And Repair Of A Variety Of Small Projects, Energy Conservation Investment Program (ecip) Program Studies/designs (more Detail Below), Or May Also Include Design Of Complete Additions, Alterations, Or New Facility Designs For Projects Such As Barracks, Warehouses, Storage Facilities, Administrative Facilities, Training Facilities, Maintenance Facilities, Aircraft Hangars, Computer Facilities, Aircraft Runways, Taxiways, Aprons, Treatment Plants, And The Entire Spectrum Of Infrastructure (road And Utility) Systems. Ecip Projects Include Energy Reduction And Renewable Energy Projects, Including But Not Limited To Photovoltaic, Wind, Microgrids, Energy Management Control Systems (emcs) And Water Conservation. Projects May Also Include Design Of Waterfront Or In Water Facilities Such As Piers And Marine Terminals, Which Would Require Design Services For Either Sustainment Of Existing Facilities Or Design Of New Facilities. Demolition Of Existing Facilities May Be Required Which Will Necessitate Asbestos And Or Lead Based Paint Investigation With Provisions For Removal Included In The Design Documents.
design Services May Also Be Required To Support The Interagency And International Services (iis) Program Providing Technical Assistance To Non-department Of Defense (dod) Federal Agencies, State And Local Governments, Tribal Nations, Private U.s. Firms, International Organizations, And Foreign Governments.
designs May Require Compliance With Previously Obtained Environmental Clearance Under The National Environmental Policy Act (nepa) Process. Project Designs May Require Measures For Environmental Restoration To Include Wetlands Development And Establishing Or Restoring Plant And Animal Habitat.
projects May Be Required To Mitigate Impacts On Protected Resources Such As Plant And Animal Species. Other Design Strategies May Be Necessary To Meet The Requirements Of An Environmental Clearance Issued For The Project, Such As Limiting Land Disturbing Activity To Specific Seasons Of The Year Or Controlling The Generation Of Dust And Equipment Exhaust. Project Designs May Also Be Required To Address Cultural And Biological Resource Preservation, Clean Air And Water Attainment Goals, And Other Resource Protection Requirements.
although The Primary Intent Of This Prospective Suite Of Idiqs Is Vertical Design, Design Services May Also Include Support Of The Civil Works Program. Civil Works Project Studies And Designs Could Involve Levees, Floodwalls, Dams, Spillways, Various Mechanical Gate Structures, Pumping Stations, Stilling Basins, Hydraulic Flow Control Structures, And Bridges. Civil Works Studies May Include, But Not Be Limited To, The Evaluation Of Flood Damage, Preparation Of Engineering Analysis, Acquisition Of Topographic And Hydrographic Data, And Environmental Restoration To Include Wetlands Development.
capability Statement
all Interested Firms Are Encouraged To Respond To This Notice And May Do So By Submitting A Capabilities Statement.
the Capabilities Statement Is Limited To Six (6) Pages Total And Shall Include The Following Information:
1) Company Name, System For Award Management Unique Entity Identification Number (sam Ueid) Or Employer Identification Number (ein), Address, Point Of Contact, Phone Number, And E-mail Address.
2) Demonstration Recency And Relevancy Of The Firm's Experience As The Designer Of Record On Projects Of Similar Size, Scope, And Complexity Within The Past Five (5) Years. List At Least Three (3) Vertical Design Projects That Have Been Constructed Within The Last Five (5) Years. Include The Project Title, Location, Brief Description Of The Project, Dollar Amount Of The Project, Period Of Performance And Percentage & Description Of Work That Was Self- Performed. Different Facility Type Designs Are Highly Encouraged To Show The Depth Of The Firm’s Design Capabilities.
3) Business Size And Socioeconomic Type For The Applicable Naics (ex: Woman-owned Small Business, Serviced-disabled Veteran-owned Small Business (sdvosb), Veteran-owned Small Business (vosb), Certified Historically Underutilized Business Zone (hubzone), 8(a) Participant, Small Business, Or Other Than Small Business (large Business)).
please Submit All Capabilities Statements, Information, Brochures, And/or Marketing Material As One Document, Limited To The Page Maximum Above.
please Consider The Following When Preparing Your Capabilities Statement: Unrestricted Task Orders Will Generally Contain More Complex Requirements With An Anticipated Value Ranging From $250,000 To $5,000,000 Or Greater. A Lower Task Order Value May Be Considered. Small Business Set Aside Task Orders Will Generally Contain Less Complex Requirements And Lower Anticipated Values. The A-e Will Be Expected To Handle Multiple Task Orders Throughout The South Pacific Division Simultaneously. Please Indicate The Dollar Amount And Number Of Task Orders Your Firm Could Comfortably Complete At The Same Time. This Will Inform The Government’s Decision About The Set Aside Of Any Contracts And Number Of Contracts To Set Aside For Small Business Concerns.
the Response Must Be Specific To The Qualifications Listed Above To Show That The Respondent Meets The Requirements And Possesses The Necessary Skills And Experience. If A Response Does Not Show That The Respondent Meets The Qualifications And/or Does Not Possess The Necessary Skills And Experience, The Results Of The Government’s Market Research Will Not Reflect The Accurate Number Of Qualified And Interested Firms.
this Is A Sources Sought Announcement Only. It Is Not A Request For Quote/proposal. There Is No Solicitation Available At This Time. This Notice Does Not Represent A Commitment By The Government To Pay For Costs Incurred In The Preparation And Submission Of Information Or Any Other Costs Incurred As A Response To This Announcement.
responses Will Not Be Considered An Offer, Proposal, Or Bid For Any Solicitation That May Result From This Notice. Moreover, Responses Will Not Restrict The Government To An Acquisition Approach. This Notice Is For Information And Planning Purposes Only. Respondents Will Not Be Notified Of The Results Of Any Review Conducted Or The Capability Statements Received.
please Provide Responses (i.e. Capabilities Statements) By E-mail To The Contract Specialist, Gilbert Coyle, At Gilbert.coyle@usace.army.mil By 0800/8:00 A.m. (pacific Time) Monday, 3 February 2025.
please Include The Sources Sought Notice Number, ‘w9123825s0011’ In The E-mail Subject Line.
Closing Date3 Feb 2025
Tender AmountRefer Documents
DEPT OF THE NAVY USA Tender
Chemical Products
Corrigendum : Closing Date Modified
United States
Description: Item Unique Identification And Valuation (jan 2023)|19||||||||||||||||||||
higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|mil-i-45208 Or Iso 9001 Ansi/ncsl Z540.3 Or Iso 10012 |
inspection Of Supplies--fixed-price (aug 1996)|2|||
navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|wss-n00104|
first Article Approval--contractor Testing (sep 1989)|10| Fat Requirements Are Included In The Drawings||15|180|n64498|tbd|tbd|45|||
notice Of Total Small Business Set-aside (oct 2020)(deviation 2020-o0008)|1||
alternate A, Annual Representations And Certifications (oct 2024)|13|x|x||x||||||||||
annual Representations And Certifications (may 2024)|13|336612|1000|x|x|x|||||||||
notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2||x|
evaluation Of First Article Testing|3|||x|
any Order Resulting From This Solicitation Will Be Issued Bi-laterally Requiring The Contractor's Written Acceptance Prior To Execution.
_______________ - Place Of Material Inspection
_______________ - Place Of Packaging Inspection & Final Acceptance
requested Delivery Is 300 Days After Date Of Contract.
quoted Delivery Is____ Days Adc.
dfars 252.232-7006, Wide Area Workflow Payment Instructions, Is Incorporated By Reference Into This Request For Quotation(rfq). Any Resulting Order Will Require Electronic Submittal Of Invoices And Receiving Reports Through Piee-wawf, And Will Include The Clause
In Full Text, Complete With Submittal Instructions.
far Clause 52.213-4, Terms And Conditions-simplified Acquisitions (other Than Commercial Products And Commercial Services), Is Incorporated By Reference Into This Rfq.this Clause Is A Compilation Of The Most Commonly Used Clauses That Apply To Simplified
acquisitions And Incorporates Them By Reference As Well.
all Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders, Delivery Orders And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By Facsimile,
or Sent By Other Electronic Commerce Methods Such As Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Herein.
dd1423 Contract Data Items Apply To This Procuremment. Contractor First Article Test And Contractor Production Lot Test Are Required To Be Completed And And Approved By N64498 Prior To Starting Production.
\
1. Scope
1.1 ;this Procurement Specification Contains The Requirements For Manufacture And The Contract Quality Requirements For ;an/bra-24 Antenna Seal Assembly; For Use On Navy Submarines.;
2. Applicable Documents
2.1 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions.
2.1.1 Documents, Drawings, And Publications Supplied Are Listed Under "drawing Number". These Items Should Be Retained Until An Award Is Made.
2.1.2 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order.
2.1.3 The "document Changes" Section Provides Supersessions/changes To Referenced Documents.
2.2 Order Of Precedence - In The Event Of A Conflict Between The Text Of This Contract/purchase Order And The References And/or Drawings Cited Herein, The Text Of This Contract/purchase Order Shall Take Precedence. Nothing In This Contract/purchase Order,
however, Shall Supersede Applicable Laws And Regulations Unless A Specific Exemption Has Been Obtained.
drawing Data=psnsy-0063-12 |80064| -|lr |d|0001 | -|49998|0103349
drawing Data=re-b102146 |80064| E| |d|0001 | E|49998|0073812
drawing Data=re-b102147 |50225| D| |d|0001 | D|49998|0046933
drawing Data=re-b102148 |50225| D| |d|0001 | D|49998|0047618
drawing Data=re-b102150 |50225| F| |d|0001 | F|49998|0050965
drawing Data=re-b102151 |50225| F| |d|0001 | F|49998|0049220
drawing Data=re-b102225 |50225| E| |d|0001 | E|49998|0050481
drawing Data=re-b102226 |50225| C| |d|0001 | C|49998|0026072
drawing Data=re-b102227 |50225| E| |d|0001 | E|49998|0043319
drawing Data=re-b102260 |80064| H| |d|0001 | H|49998|0178831
drawing Data=re-b102270 |50225| F| |d|0001 | F|49998|0043237
drawing Data=re-c102149 |50225| G| |d|0001 | G|49998|0060273
drawing Data=re-c102184 |50225| E| |d|0001 | E|49998|0035246
drawing Data=re-c49491 |80064| H| |d|0001 | H|49998|0091687
drawing Data=re-c49502 |80064| H| |d|0001 | H|49998|0125769
drawing Data=re-d102152 |80064| E| |d|0001 | E|49998|0085710
drawing Data=4677518 |80064| J| |d|0001 | J|49998|0184705
drawing Data=4677518 |80064| J| |d|0002 | J|49998|0086018
document Ref Data=fed-std-h28 |0020| |b |941221|a| |01|
document Ref Data=mil-std-130 | | |n |121116|d| |01|
document Ref Data=mil-std-973 | | | |950113|a| |03|
document Ref Data=qq-n-281d | | | |851023|a|2 | |
document Ref Data=asme B46.1 | | | |190101|a| | |
document Ref Data=iso9001 | | | |150915|a| | |
document Ref Data=sae As9390 | | |d |190401|a| | |
document Ref Data=iso10012 | | | |030415|d| | |
document Ref Data=mil-i-45208 | | |a |810724|a|1 | |
document Ref Data=ncsl Z540.3 | | | |060803|a| | |
document Ref Data=sae-ams-qq-s-763 | | |d |150301|a| | |
document Ref Data=astm B21/b21m | | | |200401|a| | |
document Ref Data=ethacure 300 Coml | | | | |a| | |
document Ref Data=adiprene L167 (90-95a) Coml | | | | |a| | |
3. Requirements
3.1 ;design And Manufacturing - The ;an/bra-24 Antenna Seal Assembly; Furnished Under This Contract/purchase Order Shall Meet The Material, Physical, Mechanical And Test Requirements As Specified On Drawings Re-c49502 (consisting Of Item Numbers 1 Thru 4)
including Associated Specifications Mentioned In This Procurement.;
3.1.1 ;the Supplier Shall Have Or Fabricate The Required Tooling To Perform The Acceptance Test Specified On Drawing Re-c49502.;
3.1.2 ;source Control Drawing Re-b102260 - The Urethane Elastomer (adiprene L167) And Curative (ethacure 300) Shall Only Be Procured For Lanxess Urethane Systems; And Shall Conform To The Requirements Specified On Drawing Re-b102260,
dash No.2. ;
3.2 ;marking Requirements - The Supplier Shall Permanetly Mark And Identify Each First Article And Production Lot Unit ;an/bra-24 Seal Assembly; In Accordance With The Requirements Of Drawing Re-c49502, Note 2 (contract Number, Vendor Part Number And Serial
number) Per Mil-std-130.;
3.2.1 ;the Supplier Shall Permanently Mark Parts Re-b102147, Re-b102148, Re-b102150, Re-b102151 And Re-c102149 As Identified On The Applicable Drawing Per Mil-std-130. The Supplier Shall Mark ;tag Or Bag; Each Part With Contract, Heat, Lot And Serial Number
per Mil-std-130 Until Installed On The Designed Assembly.;
3.2.2 ;the Supplier Shall Mark ;tagor Bag; Parts Re-b102146, Re-b102148/item No.2, Re-b102225 And Re-c49491 With Contract, Applicable Part, Heat, Lot Or Batch And Serial Number Per Mil-std-130 Until Installed On The Designated Assembly.;
3.3 ;first Article Testing/inspection - (supplier Testing/inspection). The First Article Testing/inspection Procedure And Approval Are Required For The ;an/bra-24 Seal Assembly;. Government Approval Is Required Prior To Commencement Of First Article Unit.;
3.4 ;notification - The Supplier Shall Notify Naval Surface Warfare Center, Philadelphia Division, (nswcpd) 5001 S. Broad Street, Philadelphia, Pa 19112- 1403 By Emial Matthew.j.ogilvie.civ@us.mavy.mil, Code 242mo After Award Of Contract.;
3.4.1 ;the Nswcpd Is The Acceptance Activity For The Contract Data Requirements List (dd1423) Data Items. Nswcpd Wawf/irapt ;acceptor; Dodacc Is ;n64498;.;
3.5 Configuration Control - Mil-std-973 Entitled "configuration Management", Paragraph 5.4.8, Configuration Control (short Form Procedure), Is Hereby Incorporated. The Contractor Shall Submit All Engineering Change Proposals In Accordance With Mil-std-973,
paragraph 5.4.8.2 And Appendix D. Requests For Deviations Shall Be Processed In Accordance With Mil-std-973, Paragraph 5.4.8.3 And Appendix E. Requests For Waivers Shall Be Processed In Accordance With Mil-std-973, Paragraph 5.4.8.4 And Appendix E. (original
and Two Copies Shall Be Submitted To Contracting Officer, Navicp-mech, P. O. Box 2020, Mechanicsburg Pa. 17055-0788.)
3.5.1 Configuration Control - When The Contractor Has Received Authorization On A Prior Contract For The Same Nsn For The Use Of A Drawing Of A Later Revision Status, That Authorization Is Hereby Extended To All Succeeding Contracts/purchase Orders Until
another Drawing Revision Is Approved. The Contractor Will Notify The Pco Of This Occurrence In Each Instance, In The Response To The Solicitation. Such Notification Shall Be In Writing Setting Forth The Contract Under Which The Prior Authorization Was Granted,
the Date Of The Granting Of The Authorization, And The Name Of The Granting Authority.
Contractors Shall Also Refer Technical Inquiries (other Than Those Covered By Mil-std-973) On Company Letterhead Signed By A Responsible Company Official, With Copies Distributed As Stated Below.
The Original And Two Copies Of All Contractor Generated Correspondence Regarding Configuration Shall Be Submitted To Contracting Officer, Navicp-mech, P.o. Box 2020, Mechanicsburg, Pa 17055-0788.
Contractors Are Cautioned That Implementing Engineering Changes, Waivers, Deviations Or Technical Inquiries Into The Contract/purchase Order Without Approval Of The Contracting Officer Will Be At The Sole Risk Of The Contractor.
3.6 Mercury Free - The Material Supplied Under This Contract/purchase Order Is Intended For Use On Submarines/surface Ships And Therefore Shall Contain No Metallic Mercury And Shall Be Free From Mercury Contamination. Mercury Contamination Of The Material
will Be Cause For Rejection.
If The Inclusion Of Metallic Mercury Is Required As A Functional Part Of The Material Furnished Under This Contract, The Contractor Shall Obtain Written Approval From The Procurement Contracting Officer Before Proceeding With Manufacture. The
contractor's Request Shall Explain In Detail The Requirements For Mercury, Identify Specifically The Parts To Contain Mercury, And Explain The Method Of Protection Against Mercury Escape. Such A Request Will Be Forwarded Directly To The Procurement Contracting
officer With A Copy To The Applicable Government Inspector. Upon Approval By The Contracting Officer, The Vendor Will Provide A "warning Plate" Stating That Metallic Mercury Is A Functional Part Of The Item And Will Include Name And Location Of That Part.
The Use Of Mercury, Mercury Compounds, Or Mercury-bearing Instruments And/or Equipment In A Manner Which Might Cause Contamination In The Manufacture, Assembly, Or Test Of Material On This Contract Is Prohibited. The Most Probable Causes Of
contamination Are Direct-connected Manometers, Mercury Vacuum Pumps, Mercury Seals, Or The Handling Of Mercury In The Immediate Vicinity. Mercury Switches, Mercury In Glass Thermometers, Standard Cells And Other Items Containing Mercury May Be Used If They Are
located So As Not To Constitute A Contamination Hazard.
If External Contamination By Metallic Mercury Occurs Or Is Suspected, The Following Test May Be Used To Determine Whether Contamination By Metallic Mercury Exists Or Whether Corrective Cleaning Measures Have Been Effective. Enclose The Equipment In A
polyethylene Bag Or Close-fitting Airtight Container For Eight Hours At Room Temperature (70 Degrees F Minimum).sample The Trapped Air And If Mercury Vapor Concentration Is 0.01 Mg/cu Meter Or More, The Material Is Mercury Contaminated Insofar As The
requirements Of This Contract Are Concerned.
These Requirements Shall Be Included In Any Subcontract Or Purchase Order Hereunder And The Contractor Shall Insure Subcontractor Compliance With These Requirements.
Technical Questions Pertaining To These Requirements Shall Be Referred To The Procurement Contracting Officer Via The Cognizant Administrative Contracting Officer. For Background, The Following Information Is Provided:
Mercury Is Corrosive To Gold, Silver, Nickel, Stainless Steels, Aluminum And Copper Alloys. Stainless Steels, Nickel, And Copper Alloys Are Widely Used In Reactor Plants And Other Submarine/surface Ship Systems. Accidental Trapping Of Mercury In A
component Could Cause Serious Damage To Vital Parts. Mercury Is Also Toxic If Inhaled, Ingested, Or Absorbed Through The Skin. It Is Evident That Grave Consequences Could Result From Small Amounts Of Mercury Vapor Present In An Unreplenished Submarine/surface
ship Atmosphere.
4. Quality Assurance
4.1 Responsibility For Inspection - Unless Otherwise Specified In The Contract/purchase Order, The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified Herein. Except As Otherwise Specified In The Contract/purchase Order,
the Contractor May Use His Own Or Any Other Facilities Suitable For The Performance Of The Inspection Requirements Specified Herein, Unless Disapproved By The Government. The Government Reserves The Right To Perform Any Of The Inspections Set Forth In The
specification Where Such Inspections Are Deemed Necessary To Assure Supplies And Services Conform To Prescribed Requirements.
4.2 Responsibility For Compliance - All Items Must Meet All Requirements Of This Contract/purchase Order. The Inspection Set Forth In This Specification Shall Become A Part Of The Contractor's Overall Inspection System Or Quality Program. The Absence Of Any
inspection Requirements Shall Not Relieve The Contractor Of The Responsibility Of Assuring That All Products Or Supplies Submitted To The Government For Acceptance Comply With All Requirements Of The Contract/purchase Order. Sampling In Quality Conformance
does Not Authorize Submission Of Known Defective Material, Either Indicated Or Actual, Not Does It Commit The Government To Acceptance Of Defective Material.
4.3 Records - Records Of All Inspection Work By The Contractor Shall Be Kept Complete And Available To The Government During The Performance Of Contract/purchase Order And For A Period Of 365 Calendar Days After Final Delivery Of Supplies.
4.4 ;inspection System - The Supplier's Quality Inspection System Shall Be In Accordance With Mil-i-45208 Or Iso 9001 And Ncsl Z540.3 Or Iso 10012. The Supplier Shall Develop And Submit Their Written Quality Inspection And Test Plan As Indicated On The
contract Data Requirements List (dd Form 1423). Government Approval Of The Supplier's Written Quality Inspection And Test Plan Is Required By The Contract.
cdrl: Quality Inspection & Test Plan Per Mil-i-45208, Ncsl Z540.3 And Di-qcic-81110;
4.5 ;surface Roughness - All Surface Finishes Are In Rms Measurements. Where The Degree Of Surface Roughness Is Indicated, The Surface Shall Be Free From All Visible Imperfections As Defined By Standard Asme B46.1. ;
4.6 ;finished Edges - Finished Edges Shall Be In Accordance With The Applicable Drawing Requirements.;
4.7 ;threads - Threads Shall Be Inspected In Accordance With Fed-std-h28/20 System 21 Requirements. Thread Inspection Shall Include The Measurement And Recording Of The Major Diameter For External Threads And The Minor Diameter For Internal Threads.;
4.8 ;material Control - The Supplier Shall Have An Effective Material Control System That Provides For Certified Quantitative Mill Or Industrial Laboratory Reports Of Chemical And Physical Analysis By Heat, Lot Or Batch For Raw Material Ordered For First
article And Production Units. If The Material Is Subsequently Heat-treated A Certification Of Physical Analysis, After Heat Treatment Is Also Required For Each Heat Lot Or Batch. Also, Where The Applicable Material Specification Calls Out (e.g. Corrosion
resistance Test, Macro-etch Test) These Test Results Shall Also Be Reported On The Applicable Mill Or Industrial Laboratory Report. (1) The Physical Analysis Shall Establish The Following Properties For Metallic Parts: Ultimate Tensile Strength, Yield Strength
and Elongation. (2) The Physical Analysis Shall Establish The Properties For Non-metallic Parts: Re-b102260/dash No.2 As Specified On The Drawing.;
4.9 ;first Article Testing/inspection - (supplier Testing/inspection). The Supplier Shall Perform First Article Testing/inspection On ;an/bra-24 Seal Assembly; In Accordance With The Applicable Drawings And Their Approved First Article Procedure.;
4.9.1 ;the First Article Inspection Shall Be Made By The Cognizant Dcma-qar At The Supplier's And/or Subcontractor Facility. The Supplier Shall Notify Nswcpd, Code 242mo Two Weeks In Advance Prior To The Scheduled First Article Testing/ Inspection, So An
nswcpd Representative Has The Option Of Being Present During The First Article Testing/inspection.;
4.10 ;first Article Approval For Testing/inspection Procedure And Acceptance - (supplier Testing/inspection). The Supplier Shall Prepare And Submit Their First Article Testing/inspection Procedure ;an/bra-24 Seal Assembly; In Accordance With The
requriements Of Di-ndti-80603 And Applicable Drawings As Indicated On The Contract Data Requirements List (dd Form 1423). Government Approval Of The Procedure Is Required Prior To Commencement Of First Article Unit.
cdrl: First Article Testing/inspection Procedure Per Di-ndti-80603a;
4.11 ;first Article Testing/inspection.;
4.11.1 ;visual/dimensional Inspection - The Supplier Shall Visually And Physically Inspect 100% The First Article Unit (component Parts/assembly) And Record The Actual Measurements Of Each Dimension And Threads (including Of The Major Diameter For External
threads And The Minor Diameter For Internal Threads) Identified On The Applicable Drawings Including The Results Of The Adjustment Performed Of The Assembly Per Drawing Re-c49502. Threads Shall Be Inspected 100% And Results Recorded.;
4.11.2 ;acceptance Test - The Supplieer Shall Perform Acceptance Inspection And Test On The Assembly Re-c49502 In Accordance With Drawing Requirements And Record The Actual Results. Failure To Meet The Drawing Acceptance Test Notes A And I Will Be Cause For
rejection Of The Assembly.;
4.12 ;first Article Testing/inspection Report And Acceptance - (supplier Testing/ Inspection). The Supplier Shall Submit For The First Article Unit ;an/bra-24 Seal Assembly; Testing/inspection Reports In Compliance With The Requirements Of Di-ndti-80603 And
applicable Drawings. The Report Shall Also Include A Copy Of ;certified Mill Certification; Certified Industrial Laboratory Analysis; Certificate Of Compliance And Visual/dimensional Inspection Report; Identified In The Objective Quality Evidence Records
section Of This Document, And As Indicated Ont He Contract Data Requirements List (dd Form 1423). Government Approval Of The First Article Testing/inspection Report Is Required Prior To Commencement Of Production Units.
cdrl: First Article Testing/inspection Report Per Di-ndti-80809b;
4.13 ;production Lot.;
4.13.1 ;visual/dimensional Inspection - The Supplier Shall Visually And Physically Inspect 100% Each The Production Lot Unit (component Parts/assemblies) And Record The Actual Measurements Of Each Dimension And Threads (including Of The Major Diameter For
external Threads And The Minor Diameter For Internal Threads) Identified On The Applicable Drawings Including The Results Of The Adjustment Performed On Each Assembly Per Drawing Re-c49502. Threads Shall Be Inspected 100% And Results Recorded.;
4.13.2 ;acceptance Test - The Supplier Shall Perform Acceptance Inspection And Test On Each Assembly Re-c49502 In Accordance With Drawing Requirements And Record The Actual Results. Failure To Meet The Drawing Acceptance Test Notes A And I Will Be Cause For
rejection Of The Assembly.;
4.14 ;production Lot Testing/inspection Report And Acceptance - (supplier Testing/ Inspection). The Supplier Shall Submit For The Completed Production Units ;an/bra-24 Seal Assembly; Testing/inspection Reports In Compliance With The Applicable Data Item
descriptions (dids) And Drawings. The Production Lot Testing/inspection Report Shall Consist Of ;certified Mill Certification; Certified Industrial Laboratory Analysis; Certificate Of Compliance; Visual/ Dimensional Inspection Report And Mercury Exclusion
certification; Identified In The Objective Quality Evidence Records Section Of This Document, And As Indicated On The Production Lot Test/inspection (plt) Contract Data Requirements List (dd Form 1423). Government Approval Of The Procduction Lot
testing/inspection Report Is Required Prior To Shipment Of Production Lot Units.
cdrl: Production Lot Testing/inspection Report Per Di-ndti-80809b;
4.15 ;production Lot Inspection/acceptance - (supplier Testing/inspection). The Supplier Shall Submit For The Production Lot Units, The Inspection And Test Reports Identified In The Objective Quality Evidence Records Section Of This Document And As Indicated
on The Production Lot Testing/inspection (plt) Contract Data Requirements List (dd Form 1423). Government Approval Is Required Prior To Shipment Of Production Units.;
4.16 ;final Inspection And Acceptance - Final Inspection And Acceptance Of Production Lots Shall Be Made By The Cognizant Dcma-qar In Conjuction With The Specific Government Inspection Instructions (sgiis) Furnished By Nswcpd. In Addition To The Normal Dcma
surveillance, The Production Unit(s) Shall Be Under The Surveillance Of Nswcpd Quality Assurance Specialist As Required.;
4.17 ;objective Quality Evidence Records - The Supplier Shall Maintain Objective Quality Evidence Data (oqeds) Of Raw Material And Finished Parts Of ;an/bra-24 Seal Assembly;. Records Shall Be Traceable By Drawing/item, Heat Lot Or Batch, Serial And Contract
number. All Oqeds Shall Be Clearly Legible Including Name And Title. The Supplier May Provide Exact (quality) Photocopies Of Objective Quality Evidence Records Being Delivered Under This Purchase Order Instead Of Originals.;
4.17.1 ;the Supplier Shall Furnish A Copy Of The Following Oqeds Listed Below And As Indicated On The Contract Data Requirements List (dd Form 1423) For Acceptance. The Reports Shall Be Correlated To The Drawing/item, Heat, Lot Or Batch, Serial, Contract And
assembly Number. Supplier Format Is Acceptable For The Below Listed Cdrls.
a. Certified Quantitative Mill Or Industrial Laboratory Certification (chemical And Physical Analysis) For Drawing Numbers Re-b102147, Re-b102150, Re-b102151, Re-b102225 And Re-c102149.
cdrl: Certified Mill Certificate Per Di-misc-80678
b. Certified Industrial Laboratory Analysis Shall Establish The Properties For Material Urethane Elastomer Adiprene L167 (90-95a) As Specified On Drawing Re-b102260, Dash No. 2.
cdrl: Certified Industrial Lab Analysis Per Di-misc-80678
c. Certificate Of Compliance For:
(1) Drawing Re-b102148/item No.2 (certifying Part In Accordance With The Applicable Drawing And Material Specification Requirements).
(2) Drawing Re-b102260 (certifying Curative Ethacure 300 In Accordance With Drawing Requirements).
(3) Drawings Re-d102152, Re-b102226, Re-c102184, Re-b102227, Re-b102270 And 4677518/item No. 42 Tooling Use For Acceptance Test (certifying Tooling Material And Fabrication In Accordance With The Applicable Material Specification And Drawing
requirements).
cdrl: Certificate Of Compliance Per Di-misc-80678
d. Visual/dimensional Inspection Reports Shall Show All The Characteristics, The Actual Measurement Results Of Each Dimension And Feature Inspected (componenet Parts/assemblies) Including Threads (also The Major Diameter For External Threads And The Minor
diameter For Internal Threads), Assembly Re-c49502 Acceptance Inspection And Test Results, Adjustment Of The Assembly, Contract Number, Name Of Supplier, Drawing/item Number, Drawing Revision Letter, Heat, Lot Or Batch, Serial Of Finished Parts, Assembly
serial Number, Item Nomenclature, Inspector's Acceptance Signature And Date.
cdrl: Visual/dimensional Inspection Report Per Di-ndti-80809b
e. Mercury Exclusion Certification (representing The Contract Units Shipment) Cdrl Mercury Exclusion Certification Per Di-misc-80678;
5. Packaging
5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Shall Be In Accordance With The Contract/purchase Order Schedule And As Specified Below.
mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule
6. Notes
6.1 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss)
(i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products.
a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documents That Are Required By Private Industry In Fulfillment Of Contractual Obligations In Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk.
b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. They May Be Obtained From The Publishers Of The Applicable Societies.
C. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To:
Commander, Indian Head Division, Naval Surface Warfare Center
Code 8410p, 101 Strauss Avenue
Indian Head, Md 20640-5035
d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contract Number, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For
certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document.
e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From:
Contracting Officer
Navicp-mech
Code 87321
5450 Carlisle Pike
P.o. Box 2020
Mechanicsburg, Pa. 17055-0788
f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered From:
Commanding Officer
Navicp-mech
Code 009
5450 Carlisle Pike
P.o. Box 2020
Mechanicsburg, Pa. 17055-0788
g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From:
Naval Inventory Control Point
Code 1 Support Branch
700 Robbins Avenue
Phildelphia, Pa. 19111-5094
h. Interim Changes And Classified Specifications Shall Be Obtained By Submitting A Request On Dd Form 1425 To Navicp-mech.
date Of First Submission=asreq
;;approval Of The Quality Inspection Plan By Nswc Philadelphia Division Is Required Prior To First Article.;;
;;nswcpd Is The Acceptance Activity For Cdrl Data Item A001. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;;
date Of First Submission=asreq
;;procedure Shall Be In Accordance With The Requirements Of The Applicable Drawings.;;
;;approval Of Teh Procedure By Nswc Philadelphia Division Is Required Prior To Commencement Of First Article Unit.;;
;;nswcpd Is The Acceptance Activity For Cdrl Data Item A002. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;;
date Of First Submission=asreq
;;approval Of The Report By Nswc Philadelphia Division Is Required Prior To Commencement Of Production Lot Units.;;
;;nswcpd Is The Acceptance Activity For Cdrl Data Item A003. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;;
date Of First Submission=asreq
;;supplier Format Is Acceptable.;;
;;plt Report Shall Consist Of Oqed Records Listed In Contract Section E: Certified Mill Certification; Certified Industrial Lab Analysis; Certificate Of Compliance; Visual/dimensional Inspection Report And Mercury Exclusion Certification.;;
;;approval Of The Report By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units.;;
;;nswcpd Is The Acceptance Activity For Cdrl Data Item A004. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;;
Closing Soon17 Jan 2025
Tender AmountRefer Documents
Municipality Of Itogon, Benguet Tender
Food Products
Corrigendum : Closing Date Modified
Philippines
Details: Description Lot 1 - Groceries Item No. Quantity Unit Of Issue Item Description 1 643 Kg All Purpose Flour (1kg) 2 12 Kg Baking Powder (1kg) 3 240 Packs Burger Bun (6pcs/pack) 4 519 Packs Burger Patties (6pcs/container-228g) 5 87 Packs Cheese (22 Slices/pack) 6 46 Packs Chicken Nuggets Star Shape (200g/pack) 7 20 Kg Chicken Quarter Leg (/kg) 8 133 Packs Chicken Whole / Pack 9 8 Packs Cocoa Powder (500g) 10 185 Cans Condensed Creamer (390g) 11 51 Gallon Cooking Oil (4 L/gallon) 12 53 Packs Corn Starch (1kg/pack) 13 6 Packs Dry Yeast (800g) 14 99 Trays Egg (m-30pcs/tray) 15 149 Cans Evaporated Milk (370ml) 16 364 Packs Fishball (1kg/pack) 17 105 Packs French Fries (450g) 18 20 Packs Fresh Gata (200ml) 19 143 Kg Glutinous Rice (1kg) 20 366 Packs Hotdog - Cheese Flavor (250g/pack) 21 360 Packs Hotdog - Regular (250g/pack) 22 73 Packs Jumbo Siopao (10pcs/pack) 23 18 Gallon Ketchup (4 L/gallon 24 368 Packs Kikiam (500g/pack) 25 152 Packs Longganisa Skinless (450g/pack) 26 324 Packs Longganisa Smoked (225g/pack) 27 7 Kg Margarine Classic (1kg) 28 18 Gallon Mayonaise (3.5 L/gallon) 29 20 Kg Pork Meat (/kg) 30 10 Kg Pork Meat Grind (1kg) 31 25 Packs Pork Siomai Japanese (30pcs/pack) 32 371 Packs Pork Siomai Yellow (30pcs/pack) 33 212 Packs Pork Tocino (450g/pack) 34 100 Kg Raw Peanut /kg (for Peanut Butter Making) 35 180 Packs Shanghai (15pcs/pack) 36 519 Sacks Special Commercial Rice (25kg/sack) 37 35 Sack Sugar - Washed (25kg/sack) 38 35 Kg Sugar Brown (1kg) 39 11 Sacks Sugar White- Refined (25kg/sack) 40 238 Packs Sweet Ham (220g/pack) 41 7 Packs Whip Cream Powder (500g) 42 30 Sets (100 Pcs) 12 Oz Buko Cup Set, Printed White Plastic Cup With Lid And Sealer 43 1 Set 144 Pcs High Quality Puto Molder Multicolor Baking Tools For Puto Kutchinta Assorted Medium 44 1 Pcs 22cm Sifter For Baking Premium Quality Fine Mesh Stainless Steel Strainers With Wide Resting Ear Design - Strainer Wire Mesh - Fine Mesh Strainers 45 1 Set 236pcs Cake Kit With Decoration Icing Nozzle Set Pastry Bag Spatula Muffins Cupcake Molds Baking Supplies 46 4 Unit 32cm Non-stick Frying Pan 304 Stainless Steel Frying Pan Double Layer Full Mesh Pot Cooker 47 10 Sets 50pcs 8oz/ 232ml/ Small Plastic Peanut Butter Jar 48 2 Unit "makapal Palanggana Wash Basin Stainless Steel Supported Weight 8kg Dimension (l X W X H) 63cmx63cmx16cm" 49 2 Pcs 9 Inches Round Pan 50 10 Packs "aluminum Foil 5meters/8meters Wrap Food Grade Foil Wrapper Sheet Roll" 51 4 Unit Aluminum Frying Pan "kawa" 49cmx42cmx15cm Diameter 52 1 Set Bakeware Sets 10 Piece Non-stick Bakeware Set - Carbon Steel Baking Tray Set, Suitable For Oven, Refrigerator And Freezer 53 9 Pcs Baking Pan, Non Stick, Rectangular, 27.5x18x6cm 54 5 Pcs Stainless Basin 55cm 55 1 Pcs Big Pot, Double Handle Cast Iron Size #1, Big Kawali, Frying Pan Wok 56 1 Pcs "caldero/cauldron Pot Aluminum Double Handle (d1-d5) Size (diameter 34.5cm) Sizes (lxwxh) D1=37.5x34.5x23.5cm" 57 10 Dozen Drinkingware Coffee Mug Brown Coffee Cup 9oz/ 250ml 58 100 Pcs "peanut Butter Jar/ Orange Cup Cannister Condiments Container Large 624 Grams 650ml 22oz" 59 100 Pcs "peanut Butter Jar/ Orange Cup Cannister Condiments Container Medium 454 Grams 473ml 16oz" 60 100 Pcs "peanut Butter Jar/ Orange Cup Cannister Condiments Container Small 227 Grams 234ml 8oz" 61 12 Pcs Pie Pan 12"inch X 1 Inch Height 62 5 Set "plastic Puto Cups/ Baking Cups/ Kutsinta Cups Mold/ Sauce Dish/ Macaroons/ Pichi Pichi/ Soy Sauce Thick Plastic. Good Quality. Random Color Upon Order. 100pcs Per Order Medium #5-6cm" 63 1 Pcs S/s Soup Laddle With Wooden Handle 6oz 64 2 Pcs Special J.kawa 42"-44" 65 4 Pcs Stainless Bowl 55cm 66 1 Set Stainless Steel Measuring Cup Stackable Kitchen Measuring Tool 67 2 Unit Stainless Wok Pan And Non-stick (38cm, 1.6 Kg) 68 2 Set Steel Mixing Bowl Set Of 3 With Capacity Markings Indicator Lot 2: Equipment: Item No. Quantity Unit Of Issue Item Description 1 19 Unit 11kg Lpg Gas Tank With Content 2 1 Unit 2in1 Burger Griller With Deep Fryer (with Free Cooking Kits) 3 3 Unit "3 Layer Electric Steamer 9.0l Capacity 1.1l Water Tank Capacity Rapid Steam System Pp Body And Pc Tray See Through Water Window All Removable Parts Are Dishwasher Safe 60-minutes Times Heating And Power Lights Secure Non-slip Feet" 4 3 Unit "3.5 Cu.ft. Showcase Chiller 7-level Temperature Control, Double Glass Door Blower Fan, Led Light, Price Tag Shelves 3 Adjustable Coated Wire Shelves Clean Back Design, Fan-cooled System Recessed Handle, Internal & External Lamps Switch, Front Levelling Feet 100w Input Power " 5 15 Unit 3in1 Burger Griller With Deep Fryer And Steamer 6 1 Pcs 41cm Steamer - 3 Layer Aluminum 7 1 Unit "55l Electric Oven Tempered Glass Door Accessories: Bake Tray, Baking Rack, Tray/rack Handle, Rotisserie Stick And Rotisserie Fork Inner Dimension 420x340x290mm" 8 1 Unit "5l Electric Stand Mixer Net Weight (kg): 6.6 Kg Gross Weight (packed): 8.25 Kg Net Weight (wxhxd): 420x395x255 Mm (16.54x15.55x10.04in)" 9 1 Unit 6.8 Cu.ft. Solid Top Chest Freezer/chiller 10 3 Unit 6ft. Folding Table 11 1 Unit "7 Speed Electric High Grade Super Hand Mixer Pancake/cupcake Batter Dispenser Whisk Chrome Beater Balloon Whisk He-133 *model: He-133 *body Material: Plastic *blade Material: Stainless Steel *rated Wattage: 260 Watts *rated Voltage: 220-240 Volts *gear Position: 7 Speed *rated Frequency: 50/60hz *controls Type: Knob Control *item Dimension Lxwxh: 18 X 6.5 X 12.1 Centimeters" 12 1 Unit "90 Liters Capacity Oven 250c Temperature Control 60 Min. Timer With Bell Ring With Convection And Rotisserie Function Inner Light/indicator Lamp Heater Selector Switch Tempered Glass Door Stainless Steel Heating Elements 5 Stages Of Switch Heating And Function Selector Accessories: Bake Tray 52.6 X 36.2 Cm 685x454x426mm Inner Dimension: 515x415x330mm Baking Racks, Tray/rack Handle, Rotisserie Stick And Rotisserie Forks" 13 2 Unit "blender 1.5-liter Glass Jar 2 Speed Control With Pulse Function Stainless Steel Blade Overheat Projector On Motor With Safety Lock Powerful Motor For Superior Blender" 14 1 Unit "boiler Coffee Maker And Tea Maker Perculator 7.0 Liter Double-layer Stainless Steel Wall Boil Dry Protection Switch Stainless Steel Lid With Lock Internal Water Gauge 1100 Watts" 15 1 Unit Cast Iron C40 Single Burner 16 1 Unit "chest Freezer 7.0 Cu.ft. Hd Inverter Solid Top *hd Inverter Compressor *dual Function Technology (freezer Or Chiller) *electric Control *galvanized Interior *led Light *roller Feet *recessed Handle With Key Lock *dimension (hxwxd) 85x91x55 Cm" 17 1 Unit Commercial Pressure Cooker High Quality 304 Stainless Steel Large Capacity Pressure Cooker 32cm 15 Liters 18 2 Unit Digital Weighing Scale 30kg 19 1 Unit "donut Maker 16 Hole Machine Double Sided Heating Doughnut Makers Breakfast Machine Hot Cake Waffle Maker Power: 1400w Voltage: 220-240v Plug Type: Eu Plug Power Source: Electric Color: Stainless Steel + Black Heating: Heating On Both Sides Materials: Non-stick Coated" 20 2 Unit Electric Oven 23l Heo23r 4 Function 23 Liters 21 11 Unit Electric Oven, 90 Liters Capacity, 120 Min Timer W/ Bell Ring 100-250c Temp Control 22 29 Unit Fc-06 Adf Chest Freezer 6 Cu.ft., Dual Function-freezer Or Chiller 8-level Frontal Temperature 23 1 Unit "food Dehydrator Voltage: 220v Frequency: 10 Layers 50hz Power: 800w Net Weight: 11kg Size: 380 X 400 X 465 Mm Stainless Steel Trays Outer Body Temperature: 30-90 Degress" 24 1 Unit Food Steamer Hfs-55 / 3 Level Food Steamer Food Steamer 10.0l Hfs55 25 2 Unit "four Layer Glass Box Organizer Display Four Layers, Each With A Height Of 15.25 Cm, A Length Of 61 Cm And A Width Of 23 Cm " 26 5 Unit "heavy Duty Double Burner Stove G1000max 2 Twin Jet 120mm Black Cast Iron Burner Brass Burner Cap Automatic Piezo Ignition System Gas Power: 5.2 Kw #304 Stainless Steel Body Cast Iron Trivet Unit Dimension: 69.4(w) X 36(d) X 14.5(h) Cm Box Dimension: 75(w) X 46(d) X 17(h) Cm Net Weight: 6.1 Kg Gross Weight: 7.5 Kg" 27 10 Unit "heavy Duty Electric Stand Mixer 8-speed Multiple Function Stand Mixer 5-liter Stainless Bowl 600 Watts High-powered Motor Soft Start That Minimizes Splatter With Aluminum Dough Hooks And Beater Guard With Stainless Steel Wire Whisk" 28 1 Unit Heavy Duty Ice Crusher Machine 29 1 Unit "heavy Duty Rice Cooker 5.6l Irc-560n Teflex Non-stick Coating Pot Stainless Steel Body Cool Touch Handle Pilot Light Indicator 5.6 Liter Capacity Cooks Up To 30 Cups Of Rice Measurements: L48 X W39 X H30.5cm Model: Irc-560n 1950w" 30 1 Unit Heavy Duty Single Burner Cast Iron Autmatic Ignition Gas Stove 31 1 Unit "heavy Duty Steamer Makapal Matibay Aluminum 3 Layer Steamer Bottom Layer Is The Base 2nd And 3rd Layer Are The Steamer" 32 1 Unit "heavy Duty Wet And Dry Grinding Machine Pang Giling (corn, Rice, Coffee, Soyabeans, Peanut) 1.5hp, 220v" 33 1 Unit "ice Box Cooler Insulated W/ Free Ice Scoop 45l Material Plastic Volume Capacity 45l" 34 1 Unit "microwave Oven 20l Model: P70b20ap-st Voltage: 220v Capacity: 20l Power Source: 230-240v / 50hz/ 700-1200w" 35 1 Unit "peanut Butter Machine/ Sesame Sauce Grinder/ Pulping Machine/ Nuts Almond Milk Machine Model: Hr-160y Brand: Meatpro Power: 1.5kw Hz: 60hz Rotation Speed: 1450r/min Voltage: 220v Capacity: 35pkg/h Emery Wheel Diameter: 160mm" 36 1 Pcs "square Beach Umbrella 70” Classic Style Durable And Stylish Good Quality Perfect For Outdoor Use Light Weight. Easy To Carry Anywhere Perfect Protection From Sunlight And Rain Easy Set-up" 37 1 Unit "standard Double Gas Stove With Free Regulator Stainless Top And Front Double Detachable Top Burner 560mm X 380mm X 125mm" 38 2 Unit "steamer 3 Layers Aluminum Measurement: 36cm Diameter, 13cm Height Per Layer" 39 1 Unit "vacuum Sealer Machine With Seal Bags And Starter Kit Four Sealing Modes Longer Food Preservation Theory: Temperature Controller Usage: Household Power Type: None Display Size: 2.0-3.9 Inches Color: Silver Materials: Stainless Steel + Abs Shell Seal Length: Max. 30cm Vacuum Pressure:-85 Kpa" 40 25 Unit Weighing Scale (20kg) 41 3 Unit Weighing Scale 60kg Capacity Lot 3: Agricultural Item No. Quantity Unit Of Issue Item Description 1 7 Sack 14-14-14 Fertilizer (50kg/sack) 2 1 Unit "2 In 1 Electrical And Manual Knapsack Sprayer Net Weight (kg): 5.25 Capacity Of Tank: 16l Working Pressure (mpa): 0.15-0.4 Pump: Diaphragm Pump Stroke: 1.4mm Voltage: 12 Nozzle: 1.4mm Battery: 12v / 8ah" 3 215 Meters Black Nylon Net (per Meter) 4 3 Rolls Gi Wire Gauge #14 5 1 Unit Grab Hoe, Heavy Duty, 23cm, Metal Handle 6 3 Unit "grass Cutter Gx35; Aircooled; 4 Cycle; Verticle Piston Vlave; Gasoline Engine; 31ml Maximum Output: 1.0/6500; Fuel Used: Gasoline Engine Fuel Tank Capacity (l): 76" 7 140 Kg Greenhouse Plastic, .04mil Thickness, Standard Size, Per Kilo 8 345 Kg Greenhouse Plastic, .05mil Thickness, Standard Size, Per Kilo 9 1 Unit Hand Tiller / Cultivator 7.5 Hp, Gasoline Engine Industrial Rotary Tiller Machine Cultivator Power Weeder With Complete Accessories 10 2 Unit Hand Tiller / Cultivator 7hp, Diesel Engine Industrila Rotary Tiller Machine Cultivator Machine 11 2 Rolls Rainbow Garden Hose / Water Hose 1/2" X 90m 12 8 Rolls Rainbow Garden Hose / Water Hose 3/4" X 60m 13 4 Unit Rake With Handle 14 1 Unit "rubber Garden Hose 1"" Heavy Duty Garden Hose Braided High Pressure Pvc Water Hose 50 Meters / Roll" 15 2 Unit "rubber Garden Hose 1/2"" Heavy Duty Garden Hose Braided High Pressure Pvc Water Hose 90 Meters / Roll" 16 2 Sacks Urea 50kg/sack Lot 4: Tarpaulin Item No. Quantity Unit Of Issue Item Description 1 104 Pcs Tarpaulin (2ftx3ft)
Closing Date22 Jan 2025
Tender AmountPHP 3 Million (USD 52.9 K)
DEPT OF THE ARMY USA Tender
Others
United States
Details: The Corps Of Engineers Omaha District Is Soliciting Comments From The Construction Community Addressing The Potential Use Of Project Labor Agreements (pla) For Large Scale Construction Projects (exceeding $35 Million) Within The United States Air Force Academy (colorado Springs), Colorado Area
provide Your Responses Nlt 2pm, Central Time, 07 February 2025 To Scott.dwyer@usace.army.mil. Ensure Your Response Is Limited To 5 Pages And The Subject Line Of Your Response Includes “pla Survey – Renovate Sijan Hall Phase One” And The Pla Id Number: W9128f25sm010. Please Provide Your Contact Information In The Body Of The Email.
a Pla Is Defined As A Pre-hire Collective Bargaining Agreement Between A Prime Contractor And One Or More Labor Organizations That Establishes The Terms And Conditions Of Employment For A Specific Construction Project And Is An Agreement Described In 29 U.s. C. 158(f). Federal Acquisition Regulation (far 22.503) Policy Provides That:
(a) Project Labor Agreement (pla) Is A Tool That Agencies May Use To Promote Economy And Efficiency In Federal Procurement. Pursuant To Executive Order 13502, Agencies Are Encouraged To Consider Requiring The Use Of Project Labor Agreements In Connection With Large-scale Construction Projects.
(b) An Agency May, If Appropriate, Require That Every Contractor And Subcontractor, Or Certain Subcontractors, Engaged In Construction On The Project Agree, For That Project, To Negotiate Or Become A Party To A Project Labor Agreement With One Or More Labor Organizations If The Agency Decides That The Use Of Project Labor Agreements Will
(i) Advance The Federal Governments Interest In Achieving Economy And Efficiency In Federal Procurement, Producing Labor-management Stability, And Ensuring Compliance With Laws And Regulations Governing Safety And Health, Equal Employment Opportunity, Labor And Employment Standards And Other Matters; And
(ii) Be Consistent With Law. Reference: Far 52.222-33 Notice Of Requirement For Project Labor Agreement; Far 52.222-34 Project Labor Agreement.
request Responses To The Following Questions:
(1) Do You Have Knowledge That A Pla Has Been Used In The Local Area On Projects Of This Kind? If So, Please Provide Supporting Documentation.
(2) Are You Aware Of Skilled Labor Shortages In The Area For Those Crafts That Will Be Needed To Complete The Reference Project? If So, Please Elaborate And Provide Supporting Documentation Where Possible.
(3) Are You Aware Of Time Sensitive Issues/scheduling Requirements That Would Affect The Rate At Which The Referenced Project Should Be Completed? If So, Please Elaborate And Provide Supporting Documentation Where Possible.
(4) Identify Specific Reasons Why Or How You Believe A Pla Would Advance The Federal Government’s Interest In Achieving Economy And Efficiency In Federal Procurement.
(5) Identify Specific Reasons Why You Do Not Believe A Pla Would Advance The Federal Government’s Interest In Achieving Economy And Efficiency In Federal Procurement.
(6) Identify Any Additional Information You Believe Should Be Considered On The Use Of A Pla On The Referenced Project.
(7) Identify Any Additional Information You Believe Should Be Considered On The Non-use Of A Pla On The Referenced Project.
the Information Gathered In This Survey Should Include The Following Information On Projects Completed In The Last 2 – 5 Years:
project Name And Location
detailed Project Description
initial Cost Estimate Vs. Actual Final Cost
was The Project Completed On Time?
number Of Craft Trades Present On The Project
was A Pla Used?
were There Any Challenges Experienced During The Project?
project Description:
this Upcoming Solicitation Will Be Executed Using A Design-bid-build (dbb) Project Delivery Method, Which Will Require The Contractor To Provide The Government With A Complete Facility And Warranty Based On The Request For Proposal (rfp).
the Project Will Be Located At The United States Air Force Academy In Colorado Springs Colorado. The Project Will Include Various Types Of Horizontal And Vertical Scope, Including Architectural, Interior Design, Mechanical, Electrical, Exterior Envelope, Structure, Fire Protection, And Site Improvements. Sijan Hall (building 2348) Is The Second Of The Two Cadet Dormitory Buildings At The United States Air Force Academy, Located In Colorado Springs, Colorado, And Construction Was Completed In 1968. The Primary Function Of Sijan Hall Is A Dormitory For Cadets And Was Designed To House 2,520 Students In 1968; Currently There Are 1,926 Cadets That Occupy Sijan.
several Other Ancillary Functions Are Also Housed In Sijan Hall. This Six-story Building Is Located On The South Side Of The Cadet Area. The Facility With Approximately 625,300 Square Feet Is Listed As A Part Of The Air Force Academy’s National Historic District.
the Renovation Of Sijan Hall Will Be Broken Up Into Five (5) Stand-alone Phases, With Each Phase To Be Constructed Independently, To Accommodate The Relocation Of Displaced Cadets And Thus Allow The Remainder Of The Building To Be Open And Operational As Each Phase Is Being Renovated. No Disruptions To Functions Will Be Permitted To The Phases And Portions Of The Building That Are Not Being Renovated. The Focus Of This Pla Survey Is Limited To Phase 1 Which Includes The Renovation Of Approximately 135,000 Sf Of The Building Representing Phase 1. Phase 1 Will Be Solicited As A 100% Design And Will Include, But Not Be Limited To: Interior Renovations, Exterior Curtain Wall Replacement, Mechanical, Electrical, Plumbing, Fire Protection, Life Safety, Energy Management, Any Associated Exterior And Utility Work, And Communication Systems. Other Portions Of The Building Will Be Occupied During Performance Of Work Under Phase 1. Sijan Hall Currently Does Not Meet The Latest Usafa Design Standards, So The Design To Be Constructed Under Phase 1 Will Ensure That Items Replaced Or Upgraded Comply With The Current Usafa Design Standards. Most Of The Existing Building Systems Have Exceeded Their Useful Life And Will Be Removed And Replaced As Part Of This Project. Repairs To The Facility Are Required To Address Repetitive System Maintenance, Prevent Further Deterioration Of The Building’s Systems, Components, And Infrastructure, And Facilitate Future Maintenance Of All New Building Systems And Infrastructure. The Building’s Exterior Envelope And Systems Will Need To Be Modernized To Meet The Requirements Of Unified Facilities Criteria (ufc) 1-200-02, High Performance And Sustainable Building Requirements.
phase 1 Renovation Will Address Interior Renovations, New Architectural Finishes And Interior Upgrades, Interior Work Brought Down To The Structure And Rebuilt Per Usafa Standards, The Removal And Abatement Of Asbestos Containing Materials And Lead Based Paint. Phase 1 Will Also Include Removal And Replacement Of All Exterior Curtain Wall Systems Within The Boundary Of Phase 1, And Will Provide All Mechanical, Electrical, Plumbing, And Fire Protection Work Back To The Mechanical Room(s) That Serve The Areas Within Phase 1. Phase 1 Will Also Involve Installing Building Systems To Include Mechanical, Plumbing, Low Voltage, Electrical And Communication Systems; For Example, Isolation Valves And Bypass Capability On The High Temperature Hot Water (hthw) System So Each Mechanical And Plumbing Zone Will Be Independently Isolated. In Addition, Phase 1 Will Include The Replacement Of Three (3) Substations. A Ground Source Heat Pump System Will Be Used For All Phases Of The Sijan Hall Renovation, With Phase 1 Providing The Entire Well Field, Including 160 6” Wells Drilled To Approx. 400+’. This Well Field Will Be Located South Of Sijan Hall And Placed In The Sloped Hillside North Of The Cadet Parking Lot. The Roof Of Sijan Hall Has Been Completely Replaced And Therefore Is Excluded From The Scope Of Work; However, Isolated Repairs May Be Required For Roof Penetrations Associated With Phase 1 Work.
the Overall Intent Of This Project Is To Bring The Facility Up To Code. Where Non-code Compliant Building Construction, Components, And Features Are Identified By The Life Safety And Building Code Analysis, They Will Be Corrected As Part Of The Project Construction. As Part Of The Life Safety And Building Code Analysis, The Construction Type Of The Facility Shall Be Identified. The Current Construction Type Will Comply With The International Building Code (ibc) 2018 And Applicable Ufc, Nfpa And Ada. Sijan Hall Will Be Used Primarily As A Dormitory And Will Be Classified As A Residential Group R-2. The Building Will Also Consist Of Small Accessory Assembly And Office Spaces (i.e., Individual Offices And Barber Shop). These Assembly And Office Spaces Will Be Individually Classified Per Sections 302.1 And 508.2 Of The Ibc. All Current Codes, Ufc’s And Usafa Standards Will Be Incorporated Into The Final Product. The Existing Facility Does Not Comply With Ufc 3-600-01, Fire Protection Engineering For Facilities, But Shall Be Brought To Compliance With This Ufc As Part Of This Project. This Ufc Requires Complete Sprinkler Protection Regardless Of Floor Area Or Construction Type. Also, Temporary Fire Rated Barriers Will Be Necessary To Protect Occupied Spaces From Construction Areas.
dfars 236.204, Disclosure Of The Magnitude Of Construction Projects: The Estimated Construction Cost Of This Project Is Between $100,000,000 And $250,000,000.
the Estimated Period Of Performance Is 730 Calendar Days. Construction Award Is Anticipated In The First Quarter Of Fiscal Year 2026.
contractors Responding To This Market Survey Must Submit Their Responses Via E-mail To Scott Dwyer At Scott.dwyer@usace.army.mil No Later Than 2:00 Pm (cst), Friday, 07 February 2025.
Closing Date7 Feb 2025
Tender AmountRefer Documents
U S COAST GUARD USA Tender
Others...+2Civil And Construction, Pipe Line Project
United States
Details: Statement Of Work (sow)
uscgc Haddock
fire Main Piping Repairs
background:
damaged Piping On Discharge Side Of Fire Main System. Damage Is Due To Corrosion And Has Created A Small Leak On Piping. Due To Level Of Corrosion A New Section Of Piping Will Need To Be Fabricated And Welded In Place.
reference:
coast Guard Drawings
coast Guard Drawing 87 Wpb 521-001, Rev H, Firemain Piping.
coast Guard Publications
surface Forces Logistics Center Standard Specification 0740 (sflc Std Spec 0740), 2022, Welding And Allied Processes
scope Of Work:
task Description:
crop And Renew Approximately Three (3) Linear Feet Of 2-1/2” Fire Main Piping And Associated Fittings/flanges From The Discharge Side Of The Fire/bilge Pump To The Flange Of The 2-1/2” Wafer Check Valve. See Elevation 42-e And Firemain Piping Diagram On Sheet 2 Of Coast Guard Drawing 87 Wpb 521-001 For Guidance.
requirements:
piping Renewals. Using Coast Guard Drawings 87 Wpb 521-001 As Reference, The Contractor Must Perform All Repair Tasks Designated In Task Description.
renew Any Valve Label Plate That Is Unreadable, Damaged, Broken, Lost, Etc., As Applicable With The Appropriate Valve Designation As Shown On The Applicable Compartment Check-off List As Designated By The Coast Guard Inspector.
hydrostatic Test. After All Authorized Repairs, The Contractor Must Hydrostatically Test All New And Disturbed Welded Piping And Components Of The Seawater Cooling And Firemain System In Accordance With Sflc Std Spec 0740, Appendix C, Hydrostatic Test. Ensure Zero Leakage From Or Permanent Deformation Of Pressure-containing Parts By Repairing All Leaks, Deformations, And Discrepancies. Submit A Cfr.
leak Test. After Completing All Authorized Mechanical (i.e. Threaded, Bolted, Etc.) Joint Repairs, The Contractor Must Test The Seawater Cooling And Firemain System's Operation Using The System Fluid At Normal Operating Pressure. Ensure Zero Visible Leakage From Or Deformation Of Mechanical Parts By Repairing All Leaks And Discrepancies. Submit A Cfr.
operational Test, Post Repairs. After Completion Of Work, The Contractor Must Thoroughly Test, In The Presence Of The Coast Guard Inspector And Demonstrate All Items Or Shipboard Devices That Have Been Disturbed, Used, Repaired, Altered, Or Installed To Be In Satisfactory Operating Condition. Submit A Cfr.
touch-up Preservation. The Contractor Must Prepare And Coat All New And Disturbed Surfaces To Match Existing Adjacent Surfaces In Accordance With Sflc Std Spec 6310, Paragraph 3.1.13 (touch-ups And Minor Coating Repairs.)
all Work Shall Be Accomplished With The Best Standard Practices, And By Workmen Thoroughly Experienced In The Required Trades. The Work Shall Be Supervised By Experienced Personnel And Shall Be Satisfactory To The Engineer Petty Officer.
period Of Performance:
contractor Shall Complete Repairs And Provide Deliverable Product Within 3 Weeks Of Contract Being Awarded. Approximate Dates To Begin Repair 01jul2024.
place Of Performance:
piping Has Been Removed By Ship’s Crew. Vendor Will Need To Have Adequate Facilities Or Equipment To Conduct Repairs With Piping Off Cutter.
point Of Contact And Cutter Location:
cpo Connor Green, 406-399-0209
uscgc Haddock (wpb-87347)
2710 N Harbor Dr
san Diego, Ca 92101
phone: 406-399-0209
note: The Uscg/government Reserves The Right To Award On An All Or None Basis That Is The Government May Issue A Purchase Order (po) To The Offeror That Submits The Lowest Aggregate Price Rather Than Issue A Purchase Order To Each Offeror Based On The Lowest Quotation On Each Item.
as Stated Below, The Provision At Far 52,212-2, Evaluation-commercial Items-applies With The Following Addenda:
award Of A Contract Will Be Based On The Following Criteria: The Purchase Order Will Be Awarded As A Firm Fixed Price Contract Using Simplified Acquisition Procedures In Accordance With Far Part 13.5.
1. Please Provide Any Warranty Information.
2. Vendors Must Be Registered In Www.sam.gov
the Uscg/government Intends To Award A Purchase Order Resulting From This Synopsis/solicitation To The Responsible Contractor Whose Quote Conformed To The Solicitation Which Will Be Most Advantageous And The Best Value To The Government, Price And Other Factors Considered.
please Note: Interested Offerors Having The Expertise As Required Are Invited To Submit A Firm Fixed Price Quotation That Will Be Considered By The Agency. Quotations Must Be Submitted On Company Letterhead Stationery And Must Include The Following Information ( 1) Cost Breakdown, (2) Unit Cost, (3) Extended Price, (4) Total Price, (5) Payment Terms, (6) Discount Offered For Prompt Payment, (7) Company Unique Entity Id (uei) And Cage Code..
quotes Must Be Received No Later Than Thursday, June 27, 2024 At 09:00 A.m. Eastern Standard Time. Email Quotes Are Acceptable And Should Be Sent To Timothy Ford At Email Address – Timothy.s.ford@uscg.mil And Carbon Copy Stacy Spalding At Email Address Stacy.j.spalding@uscg.mil .
any Questions Or Concerns Regarding Any Aspect Of The Rfq Must Be Forwarded To The Contracting Officer, Cwo3 Stacy Spalding At Email Address Stacy.j.spalding@uscg.mil And Carbon Copy Timothy Ford At Email Address Timothy.s.ford@uscg.mil .
the Following Far Clauses And Provisions Apply To This Acquisition:
far 52.212-1 - Instructions To Offerors - Commercial Items (oct 2018)
far 52.212-2 - Evaluation - Commercial Items (oct 2014) Award Will Be Made To The Offeror Proposing The Best Value To The Government Considering Specification, Price, Past Performance And Quality.
far 52.212-3 - Offeror Representations And Certifications - Commercial Items (oct 2018) To Include Alt I (oct 2014). Offeror Is To Complete The Annual Representations And Certification Electronically Via The System For Award Management (sam) Web Site Accessed Through Http://www.sam.gov .
far 52.212-4 - Contract Terms And Conditions -commercial Items (oct 2018) With The Following Addenda's.
far 52.212-5 - Contract Terms And Conditions Required To Implement Statutes Or Executive Orders - Commercial Items (jan 2019)
the Following Clauses And Others As Indicated By The Contracting Officer As Applicable Shall Apply To This Awarded Contract.
far 52.252-2 - Clauses Incorporated By Reference (feb 1998), The Full Text Of The Clause May Be Accessed Electronically At Internet Address Http://farsite.hill.af.mil/vffara.htm; A Data Universal Numbering System (duns) Number Is The Primary Identifier In Far 52.204-7 - System For Award Management (oct 2018).
contractors Are Located And Identified In Sam By Their Uei Number. To Facilitate Payment Via Electronic Funds Transfer - Sam, Contractors Should Be Registered In Sam. A Uei Number Can Be Obtained Via Www.dnb.com And Sam Registration Can Be Obtained Via Www.sam.gov.
the Following Clauses And Others As Indicated By The Contracting Officer As Applicable Shall Apply To This Awarded Contract.
far 52.222-3 - Convict Labor (jun 2003)
far 52.222-19 - Child Labor Cooperation With Authorities And Remedies ((jan2020) (e.o.13126).
far 52.222-21 - Prohibition Of Segregated Facilities (apr 2015)
far 52.222-26 - Equal Opportunity (sep 2016)
far 52.222-35 - Equal Opportunity For Veterans (jun 2020) (38u.s.c.4212).
far 52.222-36 - Equal Opportunity For Workers With Disabilities (jun 2020) (29u.s.c.793).
far 52.222-37 - Employment Reports On Veterans (jun 2020) (38u.s.c.4212).
far 52.222-50 - Combating Trafficking In Persons (oct 2020) (22u.s.c.chapter78 And E.o. 13627).
far 52.223-18 - Encouraging Contractor Policies To Ban Text Messaging While Driving (aug 2011)
far 52.225-1 - Buy American Supplies (jan2021) (41u.s.c.chapter83).
(51) 52.225-13, Restrictions On Certain Foreign Purchases (jun 2008) (e.o.’s, Proclamations, And Statutes Administered By The Office Of Foreign Assets Control Of The Department Of The Treasury).far 52.232-33 - Payment By Electronic Funds Transfer - Systems For Award Management (oct 2018)
far 52.233-3 - Protest After Award (aug 1996)
far 52.233-4 - Applicable Law For Breach Of Contract Claim (oct 2004)
*the Above/following Clauses Are Incorporated By Reference, Entire Clause(s) Available At Http://www.arnet.gov/far.
notice To Offerors Concerning Representations And Certifications:
this Solicitation Contains Far Clause 52.204-7, Central Contractor Registration And Far Provision 52.204-8, Annual Representations And Certifications. In Accordance With Far 4.1201 (a) Prospective Contractors Shall Complete Electronic Annual Representations And Certifications Sam Accessed Via Https://www.acquisition.gov. Please Ensure Completion Prior To Submission Of Your Quote. Also Note That Paragraph (b) Of Far 52,204-8 Applies.
Closing Date27 Jun 2025
Tender AmountRefer Documents
7451-7460 of 7489 active Tenders