Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Eprocure
Opening Date8 Nov 2024
Closing Date29 Nov 2024
Tender Amount₹ 34,78,000
Costs
EMD
₹ 69,560Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682940_1Tender No
8101/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, fix, install test and commissioning CI sluice valve flanged type 80 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed
2
-
-
Supply, fix, install test and commissioning CI sluice valve flanged type 100 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed
1
-
-
Supply, fix, install test and commissioning CI sluice valve flanged type 150 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed
1
-
-
Supply, fix, install test and commissioning CI sluice valve flanged type 200 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed
1
-
-
Comprehensive maintenance for diesel engine driven generating pumpset by carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed for upto 85 bhp installed at FWPH EOC jetty including attending to under mentioned jobs to ensure its satisfactory performance:-
Note 1: Quoted Rates are deemed to be for carrying out A checks as under.
(a) Checking the fan belt and adjusting tension
(b) Checking the fuel and oil filter
(c) Checking the air filter including cleaning and refixing
(d) Checking of FIP oil level
(e) Tightening the base bolts and nuts
(f) Checking the coupling bolts and adjustment checking the self starter and Dynamo
11
-
-
(g) Checking the battery distilled water levels and topping upto the required level.
(h) Checking the panels (Manual as well as AMF) attached to the DG set for loose connections, defects if any in the panel Board and replacement of spares all as directed.
(i) Checking the anti vibration mounting and adjusting the bolt.
(j) Checking the radiator and radiator hose and arresting leak if any
(k) Checking the engine oil level and topping upto the required level
(l) Checking the cleanliness of DG set and cleaning properly in and out of dg set around an area covering 50 mtrs
(m) Checking for any leakages after proper inspection and arresting immediately
Note 2 :- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work.
-
-
-
(ii) Servicing of DG set alongwith connected Alternator and AMF Panel Board including 'A' check of the Engine shall be carried out once in every month (Except during the month when 'B' check is carried out) as directed by the Engineer-in-Charge and the Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenence / breakdown repairs as and when required in that period except in case of major repairs. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted .
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item.
-
-
-
Maintenance and servicing of following Diesel Generator sets by carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functiuning all as per manufacturer's instructions and as directed for upto 85 bhp installed at at FWPH EOC jetty.
Note 1: Quoted Rates are deemed to be for carrying out B checks as under.
(a) Change oil
(b) Change oil filter,fuel filter,bypass filter,air filter
(c) Change water seperator
(d) Radiator cleaning with chemical
(e) Check all electrical terminals (f) check for turbo charger and service
(g) Check for injector pin and service
(h) Check for cylinder head and service
(i) Check for pit pump and service
1
-
-
NOTE 2:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work.
ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alonwith connected Alternator and AMF Panel Board including items covered in 'A' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of Major repairs.
-
-
-
(iii) Spare parts , engine oil and radiator coolant oil required during the maintenance period shall be measured and paid seperatly at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (iv) Cost of all consumables, diesel / oil filters etc., required during the maintenance period shall be deemed to be included in the rate quoted for this item.
-
-
-
Checking the tappet clearance and adjustment of valve for DG PumpSet of capacity upto 85bhp complete all as specified and directed.
1
-
-
Supply only fuel filter pre and secondary including rubber gasket for DG PumpSet of capacity upto 85bhp (Cost of replacement deemed to be included in the maintenance part of the DG set) all as specified and directed.
1
-
-
Supply only lube oil filter including rubber gasket for DG PumpSet of capacity upto 85bhp (Cost of replacement deemed to be included in the maintenance part of the DG set) all as specified and directed.
1
-
-
Supply only air filter element including rubber gasket for DG PumpSet of capacity upto 85bhp (Cost of replacement deemed to be included in the maintenance part of the DG set ) all as specified and directed.
1
-
-
Supply only fan belt of existing size forDG PumpSet of capacity upto 85bhp (Cost of replacement deemed to be included in the maintenance part of the DG set) all as specified and directed.
1
-
-
Supply only Radiator hose with clip of existing size for DG PumpSet of capacity upto 85bhp (Cost of replacement deemed to be included in the maintenance part of the DG set) all as specified and directed.
1
-
-
Supply only rubber coupling of existing size for DG PumpSet of capacity upto 85bhp (Cost of replacement deemed to be included in the maintenance part of the DG set) all as specified and directed.
1
-
-
Supply and toping up the following items DG PumpSet of capacity upto 85bhp (Cost of replacement deemed to be included in the maintenance part of the DG set) all as specified and directed.
-
-
-
Engine oil 20 W 40
10
-
-
Distilled water
15
-
-
Battery acid
2
-
-
Coolant
20
-
-
Draining the engine oil from sump removing the sump cover cleaning the sludge and refixing the same including replacement sump gasket and filling oil for DG PumpSet of capacity upto 85bhp as per manufactures instructions all as specified and directed.
1
-
-
Dismantling the fuel pump from the Engine, transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve, plunger, copper washer etc all as required including re-calibration, refixing and testing complete all as specified and directed.
2
-
-
Dismantling the water pump from the Engine and supply and fixing new water pump of existing size and testing complete all as specified and directed.
1
-
-
Dismantling the fuel AC pump from the Engine and supply and fixing new fuel AC pump of existing size and testing complete all ass specified and directed.
1
-
-
Draining out the diesel tank, cleaning / washing out the sludge and re-filling with diesel for DG Pumpset of capacity upto 85bhp all as specified and directed.
18
-
-
Taking down radiator, servicing, cleaning of with suitable reagent, washing thoroughly,arresting leakage if any by welding / brazing and refixing the same of capacity upto 85bhp (Necessary coolant and distilled water required will be measured and paid seperately under Sch item Nos ) all as specified and directed.
1
-
-
Removing and replacing of Fuel injector pipe for DG Pumpset of capacity upto 85bhp all as specified and directed.
1
-
-
Heating and varnishing of alternatorfor DG Pumpset of capacity upto 85bhp all as specified and directed.
1
-
-
Supply and replacement of the following items for DG set any capacity
-
-
-
Oil pressure gauge.
1
-
-
Battery terminal socket GM including soldering.
1
-
-
Battery terminal leads complete with brass connector
1
-
-
Radiator Cap
1
-
-
Fuel Tank Cap with Lock
1
-
-
Carbon brushes for charging alternator
1
-
-
PT Pump repair Kit
1
-
-
Replacement of AVR Suitable for for DG Pumpset of capacity upto 85bhp
1
-
-
Supply and replacement of the following items for DG set control panel of any capacity all as specified and directed.
-
-
-
AC Ammeter digital type
1
-
-
AC Volt meter digital type 0 to 500 volt.
1
-
-
lgnition switch with key for on, off and run.
1
-
-
AMF Relay 12 Volt DC
1
-
-
Battery charging alternator 12 Volt
1
-
-
Temperature Gauge with sensor
1
-
-
Removing dismantling and overhauling of 12 /24 volt starter motor, replacement of armature coil, field coil, bush bearing etc to make the starter motor serviceable complete all as specified and as directed.
1
-
-
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 100 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed.
Make : Amaron/ Exide)
1
-
-
Material and Labour for attending break down of pipe line 150 mm bore, bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes MS/CI collar etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed.
Note:- The quoted rate is deemed to be include (i) Arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending emmergency break down . (iii) Labour element required for fixing CI/DI/MS pipes, specials fittings (iv) All earth work to carry out mannually / mechanical excavator and keep mechanical excavator stand by till completion of work
15
-
-
M&L for fixing of suction and delivery MS pipe of size upto 150/200 mm dia with required modification for increased/decresed length, cutting at position, making necessary welding work complete all as specified and directed.
3
-
-
M&L for servicing, maintenance, repair, overhauling of pump from 50bhp -75bhp after dismantling , opening of complete pump, checking/replacement of all parts for any defects such as bearings, shaft ,impeller,sleeve, lantern ring, gland with bolts at both end, main shaft complete, re-assemble pump with gusket, nuts, bolts and washers, greasing all bearings, reinstall at pump base, connection with motor coupling, making proper alignment with required nuts,bolts,washers complete all as specified and directed
3
-
-
M&L for servicing, maintenance, repair, overhauling of pump from upto 20hp after dismantling , opening of complete pump, checking/replacement of all parts for any defects such as bearings, shaft ,impeller,sleeve, lantern ring, gland with bolts at both end, main shaft complete, re-assemble pump with gusket, nuts, bolts and washers, greasing all bearings, reinstall at pump base, connection with motor coupling, making proper alignment with required nuts,bolts,washers complete all as specified and directed
5
-
-
M&L for rewinding of Motor 50hp -75 hp after dismatling taking out from pump set base, transportation to civil workshop outside ND(V), opening of complete motor, dismatling stator/rotor, rewinding the complete stator of motor with existing size of super enameled copper wire as per existing turn, heating, vernishing, replacement of both end bearing, Connecton plate, Connection terminals with new copper lugs for all 06 terminal, re-assemble, transport back to ND (V), reinstall at pump base, connection with pump coupling, making proper alignment , testing for satisfactory run complete all as specified and directed . Motor Make- Kirloskar
1
-
-
M&L for rewinding of Motor upto 20hp after dismatling taking out from pump set base, transportation to civil workshop outside ND(V), opening of complete motor, dismatling stator/rotor, rewinding the complete stator of motor with existing size of super enameled copper wire as per existing turn, heating, vernishing, replacement of both end bearing, Connecton plate, Connection terminals with new copper lugs for all 06 terminal, re-assemble, transport back to ND (V), reinstall at pump base, connection with pump coupling, making proper alignment , testing for satisfactory run complete all as specified and directed . Motor Make- Kirloskar
2
-
-
M&L for servicing, maintenance, repair, overhauling of Motor 50hp -75 hp after dismatling taking out from pump set base, opening of complete motor, checking for defective bearings, Connecton plate, Connection terminals, cable lugs, re-assemble, reinstall, at pump base, connection with pump coupling, making proper alignment complete all as specified and directed . Motor Make- Kirloskar
3
-
-
M&L for servicing, maintenance, repair, overhauling of Motor upto 20hp after dismatling taking out from pump set base, opening of complete motor, checking for defective bearings, Connecton plate, Connection terminals, cable lugs, re-assemble, reinstall, at pump base, connection with pump coupling, making proper alignment complete all as specified and directed . Motor Make- Kirloskar
5
-
-
Supply only bearings of suitable size for 50hp-75hp pumpsets all as specified and directed.
3
-
-
Supply only bearings of suitable size for 20hp pumpsets all as specified and directed.
5
-
-
Supply only pump coupling alongwith new bushes for 50hp-75hp pumpsets all as specified and directed.
2
-
-
Supply only pump coupling alongwith new bushes for 20hp pumpsets all as specified and directed.
2
-
-
M&L for dismantling of electric connection cables from starter to motor, dismantling complete pump set of 50hp-75hp with foundation chanel, removing from base, keeping aside for repair of foundation PCC, pump, motor and foundation MS base frame all as specified and directed..
2
-
-
M&L for dismantling of electric connection cables from starter to motor, dismantling complete pump set of 20hp with foundation chanel, removing from base, keeping aside for repair of foundation PCC, pump, motor and foundation MS base frame all as specified and directed.
2
-
-
M&L for dismatling taking out MS support structure of any type from foundation, keeping aside for reuse or sch of credit all as specified and directed.
0.5
-
-
M&L for dismatling of foundation PCC, taking out from pump house, carrying to dumping yard inside ND (V) and necessary cleaning of work site all as specified and directed..
2
-
-
M&L for cement concrete type B1, (1:2:4) with 20mm graded agreegate in foundation, filling in and mass concrete all as specified and directed.
1
-
-
M&L for replacement of MS founation base frame of 50hp-75hp pump set made with structural steel section, as per existing size, painting with one coat of red oxide and two coat of black bituminous paint, fixing to original foundation location all as specified and directed.
2
-
-
M&L for replacement of MS founation base frameupto20hp pump set made with structural steel section, as per existing size, painting with one coat of red oxide and two coat of black bituminous paint, fixing to original foundation location all as specified and directed.
2
-
-
M&L for installation of 50hp-75hp pump and motor to original foundation position, coupling fixing, alignment of pump and motor, electric cable connection complete all as specified and directed.
2
-
-
M&L for installation upto 20hp pump and motor to original foundation position, coupling fixing, alignment of pump and motor, electric cable connection complete all as specified and directed.
2
-
-
M&L mild steel framed work with ends of bars souldered, welded or reveted or forced into spikes, framed guard bars, ladders,chequred plates framed balusters, walk ways, railings, gates, frame work of tank, valvepit and similar work incl painting with one coat of red oxide primer and one coats of anticorrosive black bituminous paint incl dismantling mild steel work of any description not otherwise specially provided for all as specified and directed.
100
-
-
Material and labour for repair, servicing, overahauling of indoor Pump control panel board comprising busbar, MCCB, metering equipment, pump starter after dismantling taking out all doors, covers from front and rear. Servicing comprising of thorough cleaning of complete inside cabinet with forced air and suitable cleaning agent, removing all dust/dirt, cleaning of all insulators, busbars, switchgears, all cable terminals with CTC and clean dry cloth, cleaning of outside surface with CTC and dry cloth, tightening of all nuts, bolts & washers. Repair comprising of replacement of burnt aluminium cable lugs, burnt switchgear, non-functional panel meters, non-functional indicator lamps, damaged panel metering wirings, nonfunctional selector switches, unsv CTs, unsv bakelite fuse with fuse
1
-
-
base, damaged panel door/cover knobs & door locks, damaged door hinges, damaged cable insulation with coloured heat shrink insulating sleeves and required nuts, bolts & washers. Overhauling comprising of dismantling cable ends from switch gear/busbar taking out from panel board and cable duct, cutting at damaged portion, providing proper aluminium cable lugs and refixing to original position with required nuts, bolts & washers complete all as specified and directed.
-
-
-
Note:- (i)Items require for replacement such as Panel Meters, indicator lamps, CT will be measured and paid seperately as supply only. Pump starters measured as S&F(ii) required cleaning items,Panel Meters, indicator lamps aluminium cable lugs, nuts-bolts-washers, door hinges, door locks, door/cover knobs, bakelite fuse base with HRC fuse, panel wiring circuits shall be inclusive of quoted rate. (iii) ACB/busbar will be measured and paid as supply and fix. (iv) Servicing/maintenance of ACBs measured seperatelly where ever applicable.
-
-
-
S&F MCCB 4 Pole, 415 V, Adjustable type, upto 160 Amps with breaking capacity 36 KA all as specified and directed.
2
-
-
S&F MCCB 4 Pole, 415 V, Adjustable type, upto 100 Amps with breaking capacity 36 KA all as specified and directed.
2
-
-
S & F CI foot valve 50/80mm flanged /screwed suitable for pumps upto 80 hp complete all as specified and directed.
2
-
-
S & F chequred plate of not less than 8mm complete all as specified and directed.
200
-
-
M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
2
-
-
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and directed.
40
-
-
Supply only Dry powder type fire extingisher ball type including mounting at various locations complete all as specified and directed
2
-
-
Supply fix install testing and commissioning fire hydrant valve CI single headed conforming to IS with iron wheel head and brass spindle flanged type 80mm including male coupling 63 mm complete all as specified and directed
2
-
-
Supply fix install testing and commissioning fire hydrant valve CI double headed conforming to IS with iron wheel head and brass spindle flanged type 80mm including male coupling 63 mm complete all as specified and directed
1
-
-
Supply and fixing rubberized fabric reinforced rubber fire hose pipe of 63mm dia conforming to is-636,15 mtr ong for bust pressure of 35.7 kg/sqcmwith brass male and female coupling bound and reveted to hose pipe with suitable clamp with ISI mark complete all as specified and directed
5
-
-
Supply and fixing internal hose box made of 2mm thick MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glass and door frame of 2mm thick MS sheet painted red outside and white inside surface incl/taking out unsv complete all specified and directed
1
-
-
S&F water level indicator dial/analog type 600mm dia of measuring capacity not less than 13 feet in depth complete with rope,float and fixing above sump including taking out old unsv one complete all as specified and directed.
1
-
-
M&l for preparation to existing surfaces and applying one coat of synthetic enamel paint fire red colour to fire hydrant and blue colour to head and writing serial no as identification code complete all as specified and directed
40
-
-
M&l for preparation to existing surfaces and applying one coat of synthetic enamel paint black colour tosluice valve complete all as specified and directed
20
-
-
Dismantling taking out GI pipe from PCC support/Trenches for repair/ replacement/ relaying for bore of pipe 25 mm complete all as specified and directed.
180
-
-
Supply, fixing and testing of GI pipe 25 mm dia Medium grade including complete GI specials on PCC support or on trenches complete all as specified and directed.
60
-
-
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 25 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
120
-
-
Dismantling taking out GI pipe from PCC support/Trenches for repair/ replacement/relaying for bore of pipe 40 mm complete all as specified and directed by engineer-in-charge
96
-
-
Supply, fixing and testing of GI pipe 40 mm dia Medium grade including complete GI specials on PCC support or on trenches complete all as specified and directed.
36
-
-
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 40 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
60
-
-
Dismantling taking out GI pipe from PCC support/Trenches for repair/ replacement/relaying for bore of pipe 50 mm complete all as specified and directed.
84
-
-
Supply, fixing and testing of GI pipe 50 mm dia Medium grade including complete GI specials on PCC support or on trenches complete all as specified and directed.
36
-
-
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 50 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
48
-
-
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed by engineer-in-charge for the bore of GI pipe upto 25/40mm. Note 1:- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending break down . (iii) Labour element required for fixing CI/DI/MS pipes, specials fittings Note 2:-CI/DI/MS Pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional
15
-
-
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed by engineer-in-charge for the bore of GI pipe upto 50/80mm. Note 1:- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending break down . (iii) Labour element required for fixing CI/DI/MS pipes, specials fittings Note 2:-CI/DI/MS Pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional
10
-
-
Supply only Gun metal gate valve of size 50mm including taking out old unserviceable one complete all as specified and directed.
3
-
-
Supply only Gun metal gate valve of size 40mm including taking out old unserviceable one complete all as specified and directed.
1
-
-
Supply only Ball valve of size 25mm including taking out old unserviceable one complete all as specified and directed.
3
-
-
Daily checking of pipe line at EOC jetty, SSP jetty, VLM jetty IN-CG jetty and 150M Gap jetty inside gallery daily and reporting of any leackage, breakage of pipe lines inside Jetty gallery all as specified and directed.
270
-
-
Supply and fix in repair 50 mm bore buterfly stainless steel valve flanged both ends for iron pipe all as specified and directed.
Make : L & T (Adco) & equivalent
3
-
-
Supply and fix in repair stainless steel male coupling type `A' of size 63 mm bore as approved suitable for fresh water cope points all as specified and directed.
3
-
-
M& L for painting to old steel surfaces of MS/GI pipe lines inside jetty gallery with one coats of synthetic enamel paint including preparation of surfaces complete all as specified and directed.
200
-
-
M& L for painting to cope points at top of jetty with one coat of synthetic enamel paint once in every month all as specified and directed.
63
-
-
M& L for white wash to all around of cope point supporting PCC once in every month all as specified and directed.
63
-
-
Material and labour for cleaning semi underground sump of 4.0 lakhs Litres capacity (Main pump house) after every six month including removing all scales, dirt and sediments etc., by using wire brush or other means from the floor and side walls of semi under-ground sump including washing the entire sump with bleaching powder and apply one coat of white wash to the inner side walls complete all as specified and as directed
Note : Each time cleaning of each semi underground sump shall be considered as one Job.
1
-
-
Chemical and biological testing of raw water from NABL accredited laboratory and submit the test report to the Engineet-in-charge complete all as specified and as directed (sample to be collected from inlet source at FWPH)
11
-
-
Attending electrical complaints of electrical pump set/ starters/LT panels provided inside Dockyard , decarbonizing the , replacing lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required and restore the power supply complete all as specified and as directed.
Note :
(i) Replacement of spares viz meters /CTs, MCCB, contracts, breakers, ACBs, starters will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted.
(ii) If the No of complaints to be attended in a starter panel / LT panel is more than 01 No in a day, altogether the complaints is considered only 1 (one).
(iii) The contractor has to engage qualified electricians and helpers in sufficient Nos to attend and rectify the defects.
80
-
-
M&L for painting after preparation of old painted external wall surface of valve pits with one coat of white wash every alternate 30 days all as specified and directed.
20
-
-
M&L for painting of old painted steel surface incl necessary preparation of 20 HP to 75 HP pump set with one coat of synthetic enamel paint complete all as specified and as directed
4
-
-
M&L painting of old painted steel surface incl necessary preparation of 1 HP to 10 HP pump set with one coat of synthetic enamel paint complete all as specified and as directed
4
-
-
Supply installation testing and commissioning of chlorination chemical dosing system comprised of pressure pump & thermoplastic cylinder shape receptacle with cover of 100 ltrs capacity for power free automatic water sanitiser /conditioning treatment station with proportional dosing arrangement with following attachments:-
Make:-Declibac(model ADS-PRO)/Eqvt a)water inlet regulator b) overflow vent c) water outlet regulator(for standalone gravity flow and offline automated gravity flow) d)drain valve e)fluid level controller f)sludge level gauge g)station base assembly with station base buffer & multi cavity arrangement h) station holding assembly j) refill cavity lids k) inbuilt level switch and processor l)flexible connecting duct Note:- Any addition/alteration required in the existing pipe line or any fittings/fixtures required for connectionof the above item are deemed to be included in this rate.
2
-
-
Supply of plastic cylinder of suitable size sealed disposable floating sanitiser station for disinfection of drinking water with arrangement for controlled releaseof disinfactant in water with basal dose control mechanism complete all as specified and directed
2
-
-
Supply of chlorine tablets contained in plastic cylinder disposable sanitiser refill(dia 2.5 inches + 0.5inches height 10 inches+ 0.5 inches) for disinfection of drinking water with arrangement for controlled release of disinfectant in water suitable for operation through dosing system.
Make:-Declibac(Type stequa 411 AE/Eqvt)
Note:-The product media should have heavy metal contaminants below declibac limits and must pass the acutetoxicity test(confirm to non toxicityfor mammalian cells) and safe for human health safety point complete all as specified and directed
2
-
-
Supply and fix centrifugal pump of capacity 230 volts single phase 1 Hp eith starter unit total head upto 06 bars discharge upto 3700 LPH complete all as specified and directed.
2
-
-
Material & labour for PCC (1:2:4), type B1 (using 20 mm graded stone aggregate) as form work and finishing the exposed surfaces of concrete fair complete all as specified and directed and dispose the waste at dumpyard inside nd(v)
5
-
-
M&L Mild Steel framed work with ends of soldered, welded or reveted or forced, framed guard bars,frame work of tank,frame work for lead joint the DI pipe with existing pipe without any leak and making the surface good with proper cementing etc, filling valvepit and similar work incl painting with one coat of red oxide primer and one coats of anticorrosive black bituminous paint incl dismantling mild steel work of any description not otherwise specially provided for all as specified and directed.
20
-
-
M&L for sub main Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed 2x10.0 sq. mm + 1x10.0 sq. mm earth wire in PVC conduit of suitable size earth wire as required complete all as specified and directed.
60
-
-
S&F SPN DB 8 WAY double door with 200 amps rated bus bar complete all as specified and directed.
2
-
-
S&F SPN MCB 40amps including removing old unsv complete all as specified and directed.
2
-
-
S&F SP MCB 40amps including removing old unsv complete all as specified and directed.
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%