Military Engineer Services Tender
... More
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Eprocure
Opening Date15 Jul 2024
Closing Date12 Sep 2024
Tender Amount₹ 24,56,000
Costs
EMD
₹ 49,120Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665944_1Bid Award Id
ViewTender No
GE(I)CG/VIZ/TOKEN 26 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
83.81
-
-
... More
Supply and lay cable cover for LT Cable Class LV,type 1 , flat size 250mmx150mm x 40 mm.
644
-
-
... More
Supplying and laying un-reinforced precast concrete class LV Type 1 cable cover size 250 mmx150mmx40 mm for cable protection in trenches complete as specified and directed by Engineer-in-Charge.
5700
-
-
... More
M&L for XLPE insulated, LT armoured electric cable with aluminium standared conductor 1100 volts grade, cross-sectional area 10 sqmm, 4.00 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc.including taking out/down old cables and testing complete all as specified and directed.
Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
200
-
-
... More
All as per Srl Item No. 7 here-in-before but cross-sectional area 16 Sqmm x 4 core
200
-
-
... More
All as per Srl Item No. 7 here-in-before but cross-sectional area 25 Sqmm x 3.5 core
200
-
-
... More
All as per Srl Item No. 7 here-in-before but cross-sectional area 35 Sqmm x 3.5 core
200
-
-
... More
All as per Srl Item No. 7 here-in-before but cross-sectional area 50 Sqmm x 3.5 core
100
-
-
... More
All as per Srl Item No. 7 here-in-before but cross-sectional area 95 Sqmm x 3.5 core
100
-
-
... More
All as per Srl Item No. 7 here-in-before but cross-sectional area 120 Sqmm x 3.5 core
100
-
-
... More
Taking down in trench/duct/wall/in floors etc. old unserviceable HT 11KV XLPE cable and Supply & laying of HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 95 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed.
Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
60
-
-
... More
Taking down in trench /duct/ wall/in floors etc. old unserviceable HT 11 KV XLPE cable and Supply & laying of HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 120 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and as directed. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
50
-
-
... More
Taking down in trench / duct / wall / in floors etc. old unserviceable HT 11 KV XLPE cable and Supply & laying of HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 240 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed.
Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
35
-
-
... More
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV HT cable by giving high voltage surge and to find out exact location of fault all as directed by the Engineer-in-Charge at site. (Note : The Item includes transportation, charging machine upto detecting fault at a time).
10
-
-
... More
M&L in repairs lightening arrestor expulsion type 11 KV with all fittings, transmission class, discharge capacity 65 Kilo amp including fixing arrangement as required and as directed (Make : Jaipuria or equivalent in make specified in Particular specification.
1
-
-
... More
S&F in repair switches air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 volts all as per clause no 19.69 of SSR part-I (2009) with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, insulator type mounted on MS channel operating rod with pad lock arrangement including dropout fuse assembly and lightning arrester complete all as specified and directed. Make :- Pactil / BHEL / Jaipuria Brothers
1
-
-
... More
M&L for repairs of 11 KV DO Fuse unit Channel type with all types of fixing arrangement complete including dismantling all as specified and directed by Engr-in-Charge Make : Jaipuria Brothers or equivalent as aprroved by AGE (I).
2
-
-
... More
M & L in repairs of Disc type, porcelain, vitreous, white, brown or green insulator single disc assembly including galvanized mild steel spindle,Two galvanized iron washer and one galvanazed nut,100 mm height,65 mm dia 11000 Volts grade.
(Make :Jaipuria & Equivalent approved by AGE(I).
8
-
-
... More
Disconnecting / dismantling in position minor servicing / overhaul of 11 KV distribution transformers 1000 KVA capacity for any type of leakage/defect at LT/HT bushing, gasket, drain plug etc., after disconnecting of electric supply and earth connections, drain out transformer oil and keeping in close containers for re-use, lifting / removing of top cover of transformer if it requires, re-assembling of transformer with S&F of new gasket set assembly, repairs of nuts, bolts and washers, as required at site, re-filling of Transformer oil, complete after electric connections and testing all as specified and directed by Engr-in-Charge.
Note :- (i) If retrieved transformer oil's di-electric strength is very less than it will be replaced with new one in relevent items.
(ii) If any minor items is required for smooth functioning of transformer including general cleaning of surrounding area and equipment also, the cost of the same will be deemed to be included in the unit rates.
1
-
-
... More
Disconnecting / dismantling in position minor servicing / overhaul of 11 KV distribution transformers 100KVA to 400 KVA capacity for any type of leakage / defect at LT / HT bushing, gasket, drain plug etc., after disconnecting of electric supply and earth connections, drain out transformer oil and keeping in close containers for re-use, lifting / removing of top cover of transformer if it requires, re-assembling of transformer with S&F of new gasket set assembly, repairs of nuts, bolts and washers, as required at site, re filling of Transformer oil, complete after electric connections and testing all as specified and directed by Engr-in-Charge.
Note :- (i) If retrieved transformer oil's di-electric strength is very less than it will be replaced with new one in relevent items.
(ii) If any minor items is required for smooth functioning of transformer including general cleaning of surrounding area and equipment also, the cost of the same will be deemed to be included in the unit rates.
1
-
-
... More
Filtration & Dehydration of transformers oil at Substation to achieve di-electric strength not less than 60 KV at 4mm gap as per relevant IS with portable filteration plant, testing of the oil for the di-electric strength before and after filteration complete all as specified and directed by Engr-in-Charge.
400
-
-
... More
Disconnecting LT/HT connection and earthing strip connection of the transformer and transportation up to workshop for repair and disconnecting , dismantling & complete overhauling of 11 KV distribution Transformer any capacity after drain out of transformer oil and kept in close containers for re use, lifting/removing of top cover of transformer & cores with chain pully blocks/crane, cleaning of sludge and washed down with the help of spray of clean oil and re-assembling of transformer with S&F of new gasket set assembly, repairs of nuts, bolts and washers, as required at site, re filling of Transformer oil after centrifuging at satifactory dielectric strength complete after electric connections and testing all as specified and directed by Engr-in-Charge.
Note :- (i) If retrieved transformer oil's di-electric strength is very less than it will be replaced with new one in relevent items.
(ii) If any minor items is required for smooth functioning of transformer including general cleaning of surrounding area and equipment also, the cost of the same will be deemed to be included in the unit rates.
(iii) Cost of transportation up to workshop & back and insttalation after repair including electric/earth connection is deemed to be included under quoted rate by the contractor.
1
-
-
... More
Overhauling of step down outdoor/indoor transformer up to 1000 KVA, 11/0.433 KV by disconnecting HT/LT terminals, descalinnning transformer oil, removing sludge, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air and reassembling complete including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet suitable for transformer top cover, terminal boxes, refilling the transformer oil after filteration and dehydration and toping up with new transformer oil, painting with two coats of synthetic enamel paint and testing and recommissioning on load etc, complete for the transformers of following rating:- (Filterationand dehydration of transformer oil and supply only transformer oil for topping up supply only of HT & LT bushings shall be measured and paid separately under respective items):-
1
-
-
... More
M&L for providing re-insulation like cotton tape/paper insulation on LT side of strip winding and resetting the same in existing position and fixing the transformer core assembly in transformer housing/tank, making complete internal electric/mechanical connections, repairs of old sleeves, bolts, nuts, washers/wires, hooks etc. including tightening of all loose connections complete all as specified and as directed by Engineer in Charge
2
-
-
... More
S & F HT bushing out door/In door type 11/12 KV HV brass metal part as per IS 3347/1967 complete with porcelain bushing, brass stem, nut,bolt,washers, brass studs and gasket etc complete.all as specified and as directed.
2
-
-
... More
M & L for LT bushing out door/In door type 1.1 KV L.V 250 brass metal part as per IS 3347/1967 complete with bushing brass stem nut,bplt,washers, brass studs and gasket etc complete.all as specified and as directed.
2
-
-
... More
M & L for LT bushing out door/In door type 1.1 KV L.V 400 Amps brass matel part as per IS 3347/1967 complete with bushing brass stem nut,bplt,washers, brass studs and gasket etc complete.all as specified and as directed.
2
-
-
... More
M & L for LT bushing out door/In door type 1.1 KV L.V 630 Amps brass matel part as per IS 3347/1967 complete with bushing brass stem nut,bplt,washers, brass studs and gasket etc complete.all as specified and as directed.
2
-
-
... More
S & F Oil level indicator of suitable capacity.
2
-
-
... More
S & F temprature Gauge of suitable sizes.
2
-
-
... More
M & L for Silica gel of good quality
8
-
-
... More
S & F Drain out Brass stop valve 25 mm dia heavy duty all as per sample and as directed all as per sample.
2
-
-
... More
M & L for painting of 11 KV distribution transformer of capacity 100 KVA to 300 KVA with synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including sign writing i.e MES No, Make , Capacity etc. complete all as specified and as directed.
2
-
-
... More
M & L for painting of 11 KV distribution transformer of capacity 1000 KVA with synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including sign writing i.e MES No, Make, Capacity etc. complete all as directed by Engineer-in-Charge.
1
-
-
... More
M & L for maintenance and overhauling of ACB up to 1600 Amps capacity including de-assembly all operating mechanism parts, well cleaning with petrol CRC 226, replacing unserviceable parts and accessories, oiling/ greasing of moving parts, cleaning of all pole partition hylem sheet, isolating contacts, re-assembly, fine setting of mechanism and pole assembly and making ACB perfect operational including well cleaning the complete panel bus bars chamber, insulator, partition etc. and checking of insulation resistance of ACB and main bus bar complete all as specified and as directed by the Engineer-in-Charge.
Note:- Spare parts for ACB to be measured and paid separately.
4
-
-
... More
Supply only Male contacts of existing size & Capacity
4
-
-
... More
Supply only Female contacts of existing size & Capacity
4
-
-
... More
Supply only Locakable Trip Push Button (LTPB)
2
-
-
... More
Supply only Lock in Isolation Position (LIP) assembly
2
-
-
... More
Supply only Lock in any position (LAP) assembly)
1
-
-
... More
Supply only Door interlock assembly
1
-
-
... More
Supply only Shunt Release (SR) of existing capacity
2
-
-
... More
Supply only Under Voltage release (UVR)
2
-
-
... More
Supply only Earth Fault Release (for DN1)
2
-
-
... More
Supply only Vertical terminal adaptor
2
-
-
... More
Repair/Maintenance of LT Panel board by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete by means of CRC-226/Petrol tightening of all joints in bus bar, checking of earth and neutral voltage and make a record, repairs of u/s nuts/bolts/washers including repairs of corroded glands, lugs/ thimbles and tightening them properly including Painting of external surface after rubbing scrapping waste diposited material, appliying primer , with two coat of enamel paint of approved shade all as directed by Engineer-in-charge.(Spares required will be measured and paid separately)
2
-
-
... More
S&F in repairs MCCB 400 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
2
-
-
... More
S&F in repairs MCCB 400 Amp capacity, 3 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
2
-
-
... More
S&F in repairs MCCB 250 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
3
-
-
... More
S&F in repairs MCCB 250 Amp capacity, 3Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
2
-
-
... More
S&F in repairs contactor 325 Amps, 2 NO + 2 NC, MCX 41, 4 Pole, 415 Volt grade, including making incoming and outgoing connections using thimbles / lugs / cables of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
2
-
-
... More
S&F in repairs contactor 160 Amps, 2 NO + 2 NC, MCX 32, 4 Pole, 415 Volt grade, including making incoming and outgoing connections using thimbles / lugs / cables of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
2
-
-
... More
S&F in repairs MCCB 160 Amp capacity, 3 Pole, 415Volt grade, rupturing capacity 25kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
3
-
-
... More
S&F in repairs MCCB 100 Amp capacity, 3 Pole, 415 Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
2
-
-
... More
S&F in repairs MCCB 63 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
4
-
-
... More
S&F in repair digital type voltmeter of size 96 x 96 mm complete
5
-
-
... More
S&F in repair digital type Ammeter of size 96 x 96 mm complete
5
-
-
... More
S&F in repair panel Multi Funtion Meter with Suitable CTs complete all as specified
3
-
-
... More
S & F Termination Cold Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for straight through joint Kit Outdoor type with Jointing Materials and accessories suitable for aluminium conductor cable of size 3 Core 180 to 240 sqmm fixed in repair, including testing after jointing complete all as specified.
1
-
-
... More
S & F Termination Cold Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for straight through joint Kit Outdoor type with Jointing Materials and accessories suitable for aluminium conductor cable of size 3 Core 95 sqmm fixed in repair, including testing after jointing complete all as specified.
2
-
-
... More
S & F Termination Cold Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination Outdoor type with Jointing Materials and accessories suitable for aluminium conductor cable up to size 3 Core 95 sqmm fixed in repair, including testing after jointing complete all as specified.
1
-
-
... More
S & F Termination Cold Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination Indoor type with Jointing Materials and accessories suitable for aluminium conductor cable up to size 3 Core 95 sqmm fixed in repair, including testing after jointing complete all as specified.
1
-
-
... More
S&F Termination Cold Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination outdoor type with Jointing Materials and accessories suitable for alumenium conductor cable oupo to size 3 Core 240 sqmm fixed in repair, including testing after jointing complete all as specified.
1
-
-
... More
M&L in repair of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
6
-
-
... More
Suppling and laying in repair Synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 Kv for electrical purpose as per IS 15652-2006, (Superseding IS 5424) suitable for electrical shock safety of sizes 2 m x 1m complete all as specified and directed.
5
-
-
... More
M&L for supply, fabrication, installation, connection, commissioning and testing of outdoor type LT panel box made out of 3.15 mm thick sheet metal cubical feeder pillar box canopy type Fondation mounted 3 ph 4 wire, 415V properly insulated aluminium bus bar 04 Nos dust and vermin proof front open with locking arrangement comprising of Digital voltmeter, ammeter suitable ratio CT’s phase indicator selector switch danger board plate completely painted with two coats of synthetic enameled paint over a coat of red oxide primer, fixing in position by provision of plate form suitable size with brick work including fixing of glazed tiles over exposed surface and addition / alternation required for fixing and connections of coming/outgoing cables & including glands, lugs & thimbles suitable for fixing incoming and outgoing all as specified and directed by Engineer-in-Charge. Incomming:- (a) MCCB Cap 65 Amps, FP 415 Volts breaking capacity 25KA - 01Nos. Out Going:-
(a) MCCB Cap 32 Amps, FP 415 Volts - 02Nos. (b) FASD Starter(10 HP) inbuilt with phase protector complete- 02 No.
(c) Start and off push button- 02 sets
(d) Digital Volt and Ameter -03 Sets
(e) Phase indicator- 03 sets
Note: The general drawing and size of panel shall be approved by GE(I)(CG) before incorporation in the work
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements