Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Ministry Of Defence

  • Opening Date

    07 Oct 2019

  • Closing Date

    17 Oct 2019

  • Tender Amount

    Refer document

  • EMD

    -

Are you Looking for Joint Venture Partners, Contractor Consortium, Project Financiers for this tender?
We will help YOU to find the right match for FREE!
Summary

Potable Water Purification System Reverse Osmosis Or Uv Based

Are you looking for Materials and Services for this tender?
We will help YOU to find the right partner for your needs for FREE!
BOQ Items

No BOQs Available

Bid Number: GEM/2019/B/380053 Dated: 07-10-2019 Bid Document Bid Details Bid End Date/Time 17-10-2019 14:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 60 (Days) Ministry/State Name Ministry Of Defence Department Name Department Of Defence Organisation Name Indian Army Office Name 224 Total Quantity 1 Item Category Potable water purification system Reverse Osmosis or UV based MSE Exemption For Years Of Experience And Turnover Yes Startup Exemption For Years Of Experience And Turnover Yes Bid to RA enabled No Potable Water Purification System Reverse Osmosis Or UV Based ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Certification for the product NA NA Certification number and date - * Manufacturers Quality System Certifications ISO 9001:2015 ISO 9001:2015 Manufacturers Environment Management System ISO 14001:2004 ISO 14001:2004 1 / 6 Certifications Manufacturers Health and Safety Management System Certifications NA NA Performance Parameters Maximum Input Water TDS allowed to the system 3000 3000 Type of water purification technology RO RO Aavailability of sediment and activated carbon filter Yes * Operation Fully automatic with auto cut off Fully automatic with auto cut off Ultraviolet (UV) LAMP Yes Yes Conformity to Standard for Ultraviolet system IS 14724 (latest) for water purification system with Ultraviolet disinfection IS 14724 (latest) for water purification system with Ultraviolet disinfection "Ultra Voilet (UV) Lamp power in watts (Hint put zero in case UV is not available)" 40 * Recovery at 27 degree Centigrade 30-40 30-40 Output Water Conforming standard IS 10500 (latest) * Filtration Capacity in liter/ hour 500 500 Provision of Arsenic removal Yes Yes Provision of Floride removal Yes Yes Provision of Chloride removal Yes Yes Alkaline filter Yes Yes Storage tank Not available Not available Type of out put water Storage Tank NA NA Storage Tank Capacity (storage tank external for higher capacity if required to be arranged by buyer) NA NA 2 / 6 Minimum inlet pressure 0.6 KG/CM2 0.6 KG/CM2 Maximum inlet pressure 3.5 KG/CM2 * Maximum inlet temperature 35 DEGREE 35 DEGREE Digital display Yes Yes Real time TDS display Yes Yes Real time pH Display No No High pressure pump Yes Yes Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes Micron Filter Yes Yes Total Dissolved Solids Removal Percentage from RO Membrane 90% 90% Particulate Filter Porosity 5 micron 5 micron Pressure vessel Sand Filter Yes Yes Pressure vessel carbon Filter Yes Yes Pressure Vessel Dual Media Filter Yes Yes Membrane Housing Yes Yes Body of filter Stainless Steel Stainless Steel Auto cut Yes Yes Number of candles 5 5 Power supply 230 Volt single phase 230 Volt single phase Installation Type Floor Mounted and Enclosed Floor Mounted and Enclosed Miscellaneous Parameters Warranty in years including replacement of filters Sediment & carbon twice a year) 1 1 Warranty in years free replacement of machine 1 1 Antiscalant- where silica is up to 10 ppm/where Mica is Yes Yes 3 / 6 up to 100 ppm Availabilty of type test Test REPORT for Filtering Size of micron Particles Yes Yes TYPE Test certificate No and date for Filtering Size of micron Particles - * Name and Address of laboratory which conducted Test for Filtering Size of micron Particles: - * Availability of type Test Report on Microbial Efficacy from Govt/NABL/ilac Lab - * Type Test certificate No and date for Microbial Efficacy - * Name of the lab - * Availability of test report from Govt/NABL/ilac Lab (Design Evalution Report as per IS:14724 Yes Yes Test certificate No and date - * Name and Address of laboratory which conducted Test - * Availability of test report from Govt/NABL/ilac Lab regarding water quality as per IS:10500 Yes * Type Test

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.