If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date7 Oct 2021
Closing Date28 Oct 2021
Tender Amount₹ 48,00,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Routine Maintenance Of Lt Net Work And Electrical

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for providing old size sub class 'B' bricks laid perpendicular to the cable abutting each other complete all as specified and directed by the Engineer-in-charge.

25

-

-

... More
Supply and spreading clean and dry river sand (unwashed) in trenches around the cable for cushioning complete all as specified & directed. Note : Punned thickness will only be measured and paid.

253

-

-

... More
Supply, laying, testing and commissioning in replacement of cable of size 4 core 16 Sqmm , XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor complete all as specified & directed. Make : Finolex/R R Kabel/Universal

1200

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 25 Sqmm.

500

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 35 Sqmm.

500

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 50 Sqmm.

500

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 70 Sqmm.

700

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 95 Sqmm.

400

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 120 Sqmm.

200

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 185 Sqmm.

200

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 300 Sqmm.

50

-

-

... More
All as per Item No. 6 above but size of cable 3.5 core 400 Sqmm.

50

-

-

... More
M&L for Painting to 9 m long steel pole with cross arms, clamps of any length and shape for LT overhead line with two coats of aluminium paint including preparation of the existing painted surfaces and marking pole numbers in a 15 cm dia white circle & marking three black & two white bends width 30 cm by fluorescent paint from bottom of the pole to 1.5 Mtr height complete all as specified and directed by the Engineer-in-Charge.

300

-

-

... More
M&L for Painting to 11 m long steel pole with cross arms, clamps of any length and shape for LT overhead line with two coats of aluminium paint including preparation of the existing painted surfaces and marking pole numbers in a 15 cm dia white circle & marking three black & two white bends width 30 cm by fluorescent paint from bottom of the pole to 1.5 Mtr height complete all as specified and directed by the Engineer-in-Charge.

20

-

-

... More
M&L for Repair and replacement of existing rusted panel board doors through welding and make good out of 2.6 mm thick CRCA sheet duly painted with two coats of approved synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by the Engineer-in-Charge.

5

-

-

... More
Repair and maintenance of of 400 KVA Capacity, 3 phase, oil cooled servo stabilizer (any make) after disconnecting all incoming/outgoing connections, taking out of dimmer stator, main transformer from the body, transformer oil etc cleaning the body, re-assembling and re-installed the same after carrying out repairs including connection and continues load testing for eight hours complete all as specified and directed: Note : (i) Supply and fixing spare parts shall be measured and paid separately under respective Items of Sch 'A'/BOQ (ii) All Work shall be carried out by OEM (Original Equipment manufacturer)

2

-

-

... More
All as per Item No. 19 above but 250/200 KVA capacity

2

-

-

... More
All as per Item No. 19 above but 160 KVA capacity

1

-

-

... More
All as per Item No. 19 above but 100 KVA capacity

2

-

-

... More
All as per Item No. 19 above but 50 KVA capacity

2

-

-

... More
All as per Item No. 19 above but 10 KVA to 30 KVA capacity

2

-

-

... More
M&L for cutting down/removing existing burnt winding from main transformer of servo stabilizer 400 KVA capacity of any make and rewinding with super enameled copper wire matching to existing gauge/size including all insulated material complete all as specified and directed.

30

-

-

... More
All as per Item No. 25 above but 160/200/250 KVA capacity

35

-

-

... More
All as per Item No. 25 above but 50/100 KVA capacity

20

-

-

... More
All as per Item No. 25 above but 30/10 KVA capacity

12

-

-

... More
S&F in replacement of RC network for 400 KVA capacity servo stabilizer of any make complete all as specified and directed.

2

-

-

... More
S&F in replacement of RC network for 160/200/250 KVA capacity servo stabilizer of any make complete all as specified and directed.

5

-

-

... More
S&F in replacement of RC network for 100 KVA capacity servo stabilizer of any make complete all as specified and directed.

2

-

-

... More
S&F in replacement of RC network for 50 KVA capacity servo stabilizer of any make complete all as specified and directed.

3

-

-

... More
S&F in replacement of RC network for 30/10 KVA capacity servo stabilizer of any make complete all as specified and directed.

2

-

-

... More
S&F in replacement of rotary switch for 400 KVA capacity servo stabilizer of any make complete all as specified and directed.

2

-

-

... More
All as per Item No. 34 above but 160/200/250 KVA capacity

3

-

-

... More
All as per Item No. 34 above but 100 KVA capacity

2

-

-

... More
All as per Item No. 34 above but 10 to 50 KVA capacity

3

-

-

... More
S&F in replacement Printed circuit board (PCB) for 400 KVA capacity servo stabilizer of any make complete all as specified and directed.

2

-

-

... More
All as per Item No. 38 above but 100/160/200/250 KVA capacity

3

-

-

... More
All as per Item No. 38 above but 10 to 50 KVA capacity

5

-

-

... More
S&F in replacement of push button of servo stabilizer of 400 KVA capacity of any make complete all as specified and directed.

2

-

-

... More
All as per Item No. 41 above but 100/160/200/250 KVA capacity

6

-

-

... More
All as per Item No. 41 above but 10 to 50 KVA capacity

5

-

-

... More
S&F in replacement of servo motor of 400 KVA capacity servo stabilizer after disconnecting all connections complete all as specified and directed.

2

-

-

... More
All as per Item No. 44 above but 100/160/200/250 KVA capacity

4

-

-

... More
All as per Item No. 44 above but 10 to 50 KVA capacity

4

-

-

... More
S&F in replacement of voltmeter 0-500 volt digital type, accuracy class 1 matching to existing one complete all as specified and directed.

5

-

-

... More
S&F in replacement of ammeter 0-500 Amps, digital type, accuracy class 1 matching to existing with CT of suitable ratio complete all as specified and directed.

3

-

-

... More
All as per Item No. 48 above but 0-150 Amps

5

-

-

... More
All as per Item No. 48 above but 0-100 Amps

5

-

-

... More
M&L for filtration of transformer oil for transformers fitted on pole/platform using movable dehydration machine by bringing the machine at site. The job included measurement of dielectric strength of transformer oil before and after filtration. The di electric strength of the transformer oil after filtration must be not less than 40 KV complete all as specified and directed. Note : The filtration will be done by a machine having suitable capacity.

1600

-

-

... More
Supply and topping up of transformer oil in transformer where oil level of transformer is below minimum level complete all as specified and directed. Note : (i) The dielectric strength of transformer oil must be not less than 40 KV (ii) The transformer oil to be brought to the site in sealed drum.

840

-

-

... More
Attending and rectifying any type of external electrical complaints by electrician and helper, disconnection of jumpers, blowing off fuse, breaking of conductor or any other type of fault (HT and LT) in North camp, Tech area , south camp , Happy Home ,71 RMU ,820 SU, Enclave, Begum Bazar , 14 P&SU and other area as directed by Engineer-in-Charge. Note : (i) The contractor will be responsible for safety, security and upkeep of installation and manpower deployed as per MES standard of installation (ii) All tools and plants like plier, screw driver, tester, test lamps, multi meter, bamboo Ladder etc for rectifying the fault occurring in 11 KV/430V/230 V VCBs, 11 KV GODs/DO fuses at Two/four Pole structure and LT Connection from Pole to main DB shall be provided by the contractor. (iii) All type of minor spare parts ie re-wirable fuse / DO fuse etc shall deemed to be included in the unit rate quoted (iv) Each job contains minimum Five complaints. (v) Each Job (minimum Five complaints) done by one Electrician (vi) Complaints shall be attended round the clock (day and night) basis as and when received (vii) Any damage occurred due to negligence of the contractor shall be made good by the contractor at his own expanses and the decision of the GE shall be final and binding in this regard.

1050

-

-

... More
S&F in replacement of MCCB, 630 Amps, 4 Pole breaking capacity 50KA thermal & magnetic adjustable type, 415 volts , 50 Hz complete all as specified and directed. Make : Legrand /Siemens/Hanger / Schneider.

1

-

-

... More
S&F in replacement of MCCB 400 Amps, 4 pole, breaking capacity 50 KA at 415 volts , 50 HZ, thermal & magnetic adjustable type complete all as specified and directed. Make : Legrand /Siemens/Hanger / Schneider.

2

-

-

... More
S&F in replacement of MCCB 320 Amps, 4 pole, breaking capacity 36 KA at 415 volts , 50 HZ, thermal & magnetic, adjustable type complete all as specified and directed. Make : Legrand /Siemens/Hanger / Schneider.

4

-

-

... More
S&F in replacement of MCCB 250 Amps, 4 pole, breaking capacity 36 KA thermal & magnetic adjustable type, 415 volts , 50 Hz . complete all as specified and directed. Make : Legrand /Siemens/Hanger / Schneider.

5

-

-

... More
S&F in replacement of MCCB 200 Amps, 4 pole, breaking capacity 36 KA at 415 volts , 50 HZ, thermal & magnetic adjustable type complete all as specified and directed. Make : Legrand /Siemens/Hanger / Schneider.

6

-

-

... More
S&F in replacement of MCCB 160 Amps, 4 pole, breaking capacity 25 KA at 415 volts , 50 HZ, thermal & magnetic adjustable type complete all as specified and directed.Make : Legrand /Siemens/Hanger / Schneider.

9

-

-

... More
S&F in replacement of MCCB 125 Amps, 4 pole, breaking capacity 25 KA at 415 volts , 50 HZ, thermal & magnetic adjustable type complete all as specified and directed. Make : Legrand /Siemens/Hanger / Schneider.

6

-

-

... More
S&F in replacement of MCCB 100 Amps, 4 pole, breaking capacity 25 KA at 415 volts , 50 HZ, thermal & magnetic adjustable type complete all as specified and directed. Make : Legrand /Siemens/Hanger / Schneider.

8

-

-

... More
M& L for cleaning the shrubs and vegetation around LT panels including levelling of surface around LT panel complete all as specified and directed by the Engineer in charge.

1000

-

-

... More
S&F in replacement of ON Load change over switch 125 Amps, 4 pole,415 volts , 50 Hz, with enclosure type complete all as specified and directed. Make : Legrand /Havells/HPL

2

-

-

... More
S&F in replacement of ON Load change over switch 250 Amps, 4 pole,415 volts , 50 Hz, with enclosure type complete all as specified and directed. Make : Legrand /Havells/HPL

2

-

-

... More
S&F in replacement of ON Load change over switch 320 Amps, 4 pole,415 volts , 50 Hz, with enclosure type complete all as specified and directed. Make : Legrand /Havells/HPL

2

-

-

... More
S&F in replacement of ON Load change over switch 400 Amps, 4 pole,415 volts , 50 Hz, with enclosure type complete all as specified and directed. Make : Legrand /Havells/HPL

2

-

-

... More
M&L for disconnecting all incoming and outgoing cables from APFC Panels and refreshing all connections by replacement of carbonised lugs including taking out burnt parts from APFC panels working of contactors MCCBs, indicators, wiring kit, cpacitor banks all as directed and ressembling and testing for smooth functioning of relays timers, and electronic parts complete all as specified and directed. Note : Cost of lugs, glands, PVC tape and GI nut bolts deemed to be included in the qoted rates.

7

-

-

... More
S&F in replacement of contactor of following size :-

-

-

-

... More
MNX-12

2

-

-

... More
MNX-25

2

-

-

... More
MNX-45

2

-

-

... More
S&F in replacement of capacitor bank any type of following size :-

-

-

-

... More
30 to 50 KVR

2

-

-

... More
20 to 25 KVR

2

-

-

... More
5 to 15 KVR

2

-

-

... More
S&F in replacement of DIN type HN fuse link of following size :-

-

-

-

... More
100 to 125 Amp

2

-

-

... More
160 to 200 Amp

2

-

-

... More
250 to 200 Amp

2

-

-

... More
400 to 630 Amp

2

-

-

... More
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.