Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date16 Oct 2024
Closing Date28 Nov 2024
Tender Amount₹ 13,46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.

1

12729

-

... More
Sch A Part III (INTERNAL ELECTRIFICATIONS)

-

-

-

... More
Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part III .

1

1656672

-

... More
Sch A Part IV (EXTERNAL WATER SUPPLY)

-

-

-

... More
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV .

1

339723

-

... More
Sch A Part V (EXTERNAL ELECTRIFICATIONS)

-

-

-

... More
Lump sum price worked out by the contractor for External Electrifications as listed in Sch ‘A’ Part V.

1

1804319

-

... More
Sch A Part VI (SEWAGE DISPOSAL)

-

-

-

... More
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.

1

269863

-

... More
Sch A Part VII (AREA DRAINAGE)

-

-

-

... More
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII

1

964276

-

... More
Sch A Part VIII (ROAD/PATH AND CULVERT)

-

-

-

... More
Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ Part VIII

1

8321065

-

... More
Sch A Part IX (DEMOLITION AND DISMANTLING)

-

-

-

... More
Lump sum price worked out by the contractor for Demolition and Dismantling as listed in Sch ‘A’ Part IX

1

1918425

-

... More
Sch A Part X (SITE CLEARANCE & DEVELOPMENT)

-

-

-

... More
Lump sum price worked out by the contractor for Site Clearance & Development as listed in Sch ‘A’ Part X

1

421470

-

... More
Sch A Part XI (Lift and Miscellaneous Items of B/R and E/M)

-

-

-

... More
Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.

15

-

-

... More
Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS: 8329/2000 in standard length of 5.50-6.00 meter of classification K-7 including rubber tyton jointing material suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 150 mm bore, including aligning the pipes inside trench as per IS: 12288/1987 and testing the joints with required water pressure complete all as specified & directed. Notes:- (i) Excavation earth works shall be measured and paid separately. (ii) Joints CI/DI specials shall be measured and paid separately. (iii) Joints Material rubber tyton joint and Lead joint etc included in the quoted rate.

180

-

-

... More
Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS: 8329/2000 in standard length of 5.50-6.00 meter of classification K-7 including rubber tyton jointing material suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 100 mm bore, including aligning the pipes inside trench as per IS: 12288/1987 and testing the joints with required water pressure complete all as specified & directed. Notes:- (i) Excavation earth works shall be measured and paid separately. (ii) Joints CI/DI specials shall be measured and paid separately. (iii) Joints Material rubber tyton joint and Lead joint etc included in the quoted rate.

80

-

-

... More
M&L for upto 150 mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, flanged spigot,caps and plugs complete all as specified and directed.

65

-

-

... More
Dismantling old broken / damaged valve pit chamber and construct valve pit chamber of size 1050mm x 1050 mm x 1050 mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.

6

-

-

... More
M&L for disconnecting the electrical supply of LT panel ,dismantling and shifting of LT panel of any size by taking out from PCC foundation complete and shifting to other location as per direction fixing the panel in true vertical position including excavation and earth work, PCC 1:3:6 type C1(using 20mm graded stone aggregate) complete all as directed by Engineer-in-Charge.Note: 1. Necessary electric shutdown to the panel will be given before the work.

1

-

-

... More
Supply , installations , testing & commissioning in replacement of 11 KV of rating 630 Amp RMU unit outdoor type (IP-54) protection duly painted(Paint shade in painted Alu Zn/RAL 7032 on sheet steel for door and covers), VCB type I RMU( RING Main unit) Four way comprising of Three numbers insulated load break switch as outgoing and one number Vacuum Circuit Breaker as incoming inside . RMU should be provided with Copper Bus bar , one number fault passage indicator with each incoming and outgoing mechanism for interlocking arrangements for powered relay complete with all accessories as under.(a) RMU type installation Outdoor Extensible type, arc proof as per IEC : 62271-200 for design Manufacturing and testing . The RMU must have the following features/specification:- INCOMER :- VCB should have following specification :- (i) Rated Voltage upto -12KV (ii) Rated power frequency withstand voltage -28KV(iii) Rated lighting impulse withstand voltage –should be minimum 125KVP (iv) Rate d current for ring main feeder -630A (v) Rated current for VCB feeder -630A (vi) Rated short-time current-21 KA/3 Sec(vii) Rate Short making current -50KA (viii) Ambient temperature (-1 degree Celsius to +45degree Celsius), (ix) Degree of protection against accidental contact and ingress of foreign objects must be assured as under:- (aa) Main electric circuits : IP-67(ab) Fuse compartment IP3X (ac) Operating mechanism –IPXC ,(ad) Cable connection compartment-IPXC with site replaceable cable bushing . (xi) Each vacuum circuit Breaker includes :

1

-

-

... More
(aa) Manual VCB with position ON-OFF manual spring charging mechanism with in built spring charging handle mechanically latched ON/OFF push buttons (ab) Manual line disconnector with three position switches ON-OFF–EARTH, (ac) Auxiliary switches 6 NO + 6NC with wiring , (ad) IDMT Numerical relay for Over current and earth fault protection , (ae) Three phase definite time over current and short-circuit protection with variable tripping times (ANSI 50/51) 3 Phase over Current protection with selectable inverse time characteristics and definite time short-circuit current element (ANSI20/51) definite (af) Capacitive Voltage indicator (ag) Padlocking facility (ah) Dedicated CTs for protection,((xii) Operating handle -1 number (xii) Right angled Cable boots -3x sets (xiv) Capacitor (xv) Any other standard accessories required for efficient operation of RMU as per OEM recommendations.

-

-

-

... More
OUTGOING :-(i) Each load break Switches includes:- (a) three position switches with position ON-OFF -EARTH (b) Manual operated spring mechanism ON-OFF-EARTH (c) Mechanical indicators for position ON-OFF-EARTH , (d) Mimic diagram at the front facia of RMU , (e) Capacitive Voltage indicator , (f) Padlocking facility , (g) Fault passage indicator for Earth Fault .(ii) Right angled Cable boots -3x sets (iii)The quoted rate shall be demmed to include cost of PCC foundation and PCC plateform of suitable size as per OEM recommendation 100 mm thick PCC 1:2:4 type B1 (20 mm graded stone aggregate) over 100 mm thick hard core of 63 mm complete. Make of RMU: ABB/SCHNEIDER/SIEMENS or as specified in particular specification.

-

-

-

... More
Supply, installation, commissioning and testing LT panel board, conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral, outdoor (Kiosk) type with apron, of suitable size, factory made, fabricated with 3.15mm thick mild steel sheet (Outer Body), ISMC-75 base channels, duly powder caoted internally and externally painted with seven tank process with approved shade, rubber gasketted, hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof, internal wiring with suitable size of PVC FRLS copper conductor cable complete including suitable size lugs, glands etc. incl one no. brass pad lock, 50mm size, 4 levers and making connections, incl earth work and PCC foundation complete comprising of the followings and specified: - (i) Aluminium bus bar 1.4 time of current rating incoming capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick and epoxy insulators 1100 volts rating 8 nos. (ii) Cable alley for I/C 400 Amps and all outgoing feeders Incoming: - (a) MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA -01 Nos (b) Meter module digital volt and amp meter incl CTs of appropriate size with accessories -01 Nos (c) 3 phase bulk meter incl ct and pt and current range(10-60A) in 1phase Outgoing: - (a) MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA -01 Nos (b) MCCB 4 Pole, 415 V,Adjustable type ,100 Amps with breaking capacity 16 KA -02 Nos (c) MCB 63 Amp 230V with breaking capacity of 16 KA - 02 Nos

1

-

-

... More
Supply, installation, commissioning and testing LT panel board, conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral, outdoor (Kiosk) type with apron, of suitable size, factory made, fabricated with 3.15mm thick mild steel sheet (Outer Body), ISMC-75 base channels, duly powder caoted internally and externally painted with seven tank process with approved shade, rubber gasketted, hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof, internal wiring with suitable size of PVC FRLS copper conductor cable complete including suitable size lugs, glands etc. incl one no. brass pad lock, 50mm size, 4 levers and making connections, incl earth work and PCC foundation complete comprising of the followings and specified: - (i) Aluminium bus bar 1.4 type of incomming Amps current rating capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick and epoxy insulators 1100 volts rating 8 nos. (ii) Cable alley for I/C 400 Amps and all outgoing feeders Incoming: - (a) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA -01 Nos (b) Meter module digital volt and amp meter incl CTs of appropriate size with accessories -01 Nos Outgoing: - (a) MCCB 4 Pole, 415 V, 40 Amps with breaking capacity 16 KA -02 Nos (b) change over switch 63A -01 Nos

1

-

-

... More
S&F for CP jet sprey with 1 Mtr long CP flexible tube complete all as specified and directed.

3

-

-

... More
Supply & Fixing angle cock of 15 mm bore dia chromium plated fancy type screwed both ends for iron pipes or for brass ferrule complete all as specified & directed

3

-

-

... More
Supply & Fixing Pillar tap 15 mm bore chromium plated fancy type cast copper alloy with capstan heads half or full turn, screwed down high pressure with or without letter ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts screwed for iron pipes or for brass ferrule complete all as specified & directed.

3

-

-

... More
Design supply, install testing & commissioning passengers lift for 13 passenger (884 Kg). speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+ 03 upper floors with AC Variable Voltage & Variable Frequency drive (V V V F drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door). complete all as specified and directed by Engineer-in-Charge. Note:- Overall quoted rates including of all consumables and minor parts Annual maintenance contract (AMC) during the defect liability period of two year. Necessary MoU shall be submitted by the contractor duly signed by the OEM of AMC and further maintenance.

2

-

-

... More
Supply, installation, testing and commissioning of Smart meter ( RF / Cellular / Hybrid (RF+Cellular)) Three Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A having valid BIS licence of IS-16444-2015 (Reaffirmed 2020) and relevant IEC standards with default and on demand display, billing data generation facility, with prepaid and postpaid facility, anti-tamper features, Microprocessor and LED/LCD based circuitry, including integration and maintaining the Advance Metering infrastructure (AMI) of smart meters of different makes having valid BIS certification mark with specific CM/L number (not more than 33% of particular one make) to ensure interchangeability at later date using communication technology including GPRS/RF/Hybrid (RF + cellular) or any other advanced technology as per CEA/TRAI regulation in order to achieve overall economy in operation and maintenance.

6

-

-

... More
Supply, installation, testing and commissioning of Smart meter ( RF / Cellular / Hybrid (RF+Cellular)) Single Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A having valid BIS licence of IS-16444-2015 (Reaffirmed 2020) and relevant IEC standards with default and on demand display, billing data generation facility, with prepaid and postpaid facility, anti-tamper features, Microprocessor and LED/LCD based circuitry, including integration and maintaining the Advance Metering infrastructure (AMI) of smart meters of different makes having valid BIS certification mark with specific CM/L number (not more than 33% of particular one make) to ensure interchangeability at later date using communication technology including GPRS/RF/Hybrid (RF + cellular) or any other advanced technology as per CEA/TRAI regulation in order to achieve overall economy in operation and maintenance.

3

-

-

... More
Supply and fixing factory made epoxy powder coated distribution board MCCB VTPN 8 way double door 430 volt, IP-43, suitable for 125 Amps MCCB including 200 Amps copper bus bar ,neutral bar complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB's of cables/wires complete all as specified and directed.

1

-

-

... More
Supply and fixing factory made epoxy powder coated distribution board MCB DB VTPN 8 way double door 430 volt, IP-43, suitable for 63 Amps TPN including 200 Amps copper bus bar ,neutral bar complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB's of cables/wires complete all as specified and directed.

6

-

-

... More
Sch A Part XII (Manning and operation of lifts during Defect Liability period of two years and three years after defect liability period)

-

-

-

... More
Manning and operation of both the lifts installed here in before for two years during defect liability period and three years after defect liability period by employing one semiskilled category industrial person in each lift wearing uniform in one shift per day of 08 hrs including Sunday and holiday complete all as specified and directed for following time period:-

-

-

-

... More
For first 11 months

11

-

-

... More
For second 11 Months

11

-

-

... More
For Third 11 Months

11

-

-

... More
For fourth 11 Months

11

-

-

... More
For Fifth 11 Months

11

-

-

... More
For Last 05 Months

5

-

-

... More
Sch A Part XIII (Annual Maintenance of lifts after defect liability period)

-

-

-

... More
M&L for annual maintenance of both the Lifts by performing all fortnightly, monthly, bi-monthly, half yearly and yearly checks and tests and service as per specified intervals including all repair and replacement of unserviceable spare parts for making the Lifts serviceable after the completion of defects liability period (DLP) through OEM complete all as specified and directed for the followings time period:-

-

-

-

... More
For first year after Defect liability period.

12

-

-

... More
For second year after Defect liability period.

12

-

-

... More
For third year after Defect liability period.

12

-

-

... More
Note for item No. 13.01 to 13.04:- (a) The contractor shall enter into MoU with the OEMs for the provision of the lift and further maintenance. The MoU for the post warranty/post defect liability period between the contractor and OEM shall be submitted by the contractor. (b) The rates quoted is inclusive of all consumable and minor parts but excluding of spare parts as listed in PC Sum (Schedule A Part-XIV). If there is any requirement of major spare parts, same will be measured and paid seperately under PC Sum Schedule.

-

-

-

... More
Sch A Part XIV (PRIME COST SUM)

-

-

-

... More
Lump sum price worked out by the contractor for Prime Cost Sum as listed in as listed in Sch ‘A’ Part XIV. Note :- The amount to be quoted by the Tenderer in BOQ against the inserted price by the department shall be restricted to Maximum 15% over and above the prime cost sum, accordingly the tenderer shall quote the amount.

1

20800

-

... More
Deduct Schedule of Credit of Rs. 5,63,117.40 as brought out from Credit Schedule Sr Page No. ___ of tender

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.