Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Eprocure
Opening Date27 Apr 2020
Closing Date13 Jun 2020
Tender Amount₹ 36,50,174 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,33,360Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_318265_2Bid Award Id
ViewTender No
CWE/JHA/BAB/66 OF 2019-20Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for repair/replacement of new generation energy saving and environmental friendly long life LED post top light with alumuinium housing, clear arylic diffuser, cast aluminium pole cap complete with accesories suitable for OD of 75 mm pipe with IP - 66 power consumption 25 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable light any type/any capacity including replacement of twisted 3 core aluminium cable of size 1.5 Sqmm dia for connecting phase, neutral and earth all as specified and directed.
Make : Havell's. Model No : RUBYPT25WLED757PSYMTOPC or equivalent make of Bajaj / Wipro / Philips / Crompton.
15
-
-
M&L for replacement of GI brackets for LED street light fitting fabricated with GI tubing of size 40 mm dia medium grade 1.2 mtr long bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 6 mm suitable length 02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed.
250
-
-
S & F looping box outdoor type enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box (sintex make) front openable including locking arrangements of size 200 x 140 x 95 conforming IP 66 including 04 Nos connector of suitable size including MCB of capacity 06 Amp complete fix to pole with necessary clamps of size 30 x 4 mm and nuts, bolts & washers complete all as specified and directed.
Make :Sintex / Hensel or equivalent as approved by GE.
200
-
-
Supply, laying, conntecting and testing underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 25 Sqmm 4 core 1100 volts grade cross-sectional area incl taking down complete all as specified and directed.
Make : Havell's / Polycab / Paragon / Gloster / Finolex / KEI / RPG.
300
-
-
Supply, laying, conntecting and testing underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 16 Sqmm 4 core 1100 volts grade cross-sectional area incl taking down complete all as specified and directed.
Make : Havell's / Polycab / Paragon / Gloster / Finolex / KEI / RPG.
250
-
-
Supply, laying, conntecting and testing underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 10 Sqmm 4 core 1100 volts grade cross-sectional area incl taking down complete all as specified and directed.
Make : Havell's / Polycab / Paragon / Gloster / Finolex / KEI / RPG.
400
-
-
Supply, laying, conntecting and testing underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 10 Sqmm 2 core 1100 volts grade cross-sectional area incl taking down complete all as specified and directed.
Make : Havell's / Polycab / Paragon / Gloster / Finolex / KEI / RPG.
350
-
-
Supply, laying, conntecting and testing underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 6 Sqmm 2 core 1100 volts grade cross-sectional area incl taking down complete all as specified and directed.
Make : Havell's / Polycab / Paragon / Gloster / Finolex / KEI / RPG.
300
-
-
M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 50 mm dia bore complete all as specified and as directed.
50
-
-
M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 40 mm dia bore complete all as specified and as directed.
50
-
-
Supply & fixing of 3 phase automatic street light switch using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹30 Lux and for switching OFF ›10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress three phase 12 KW lightning load capacity including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a) Incomming MCB SP - 40 Amp = 03 Nos (b) Outgoing MCB SP - 40 Amp = 03 Nos (c) Contactor Single pole 40 Amp = 03 Nos. (d) Three phase circuit wiring minimum 10 Sqmm multistranded copper wire. (e) The rate also includes one spare contactor 40 Amp and one MCB 40 Amps (f) Model No : SWADEEP-66 12 KW3P. Make : Kakatiya Energy Systems Ltd or equivalent make approved by GE.
4
-
-
M&L for repair/replacement of 8 KW, single phase automatic street light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor, overload protection fuse gear, power contactor & MCB, terminal blocks for cable entry & control unit enclosed in pole/wall mountable enclosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66, with universal olck and key arrangement complete all as specified and as directed.(The rate includes 01 contactor of same capacity of above issue as spare). (a) Power Contactor 63 Amp Single Phase - 01 No
(b) Incoming MCB 63 Amp Single Pole - 01 No (c) Outgoing MCB 63 Amp Single Pole - 01 No Make : Kakatiya Energy System pvt Ltd or equivalent make approved by GE. Cat No : swadeep-66 8kw1P
4
-
-
M&L for cutting of road up to 0.75 m deep suitable for laying underground cables/MS tubes of any size/dia & making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50 mtr complete all as specified and directed.
30
-
-
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead 4.0 mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick PCC slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbows etc shall be deemed to included in the quoted rate.
25
-
-
S&F in replacement of danger notice plate of 1.6 mm thick mild steel sheet vitreous enamaled white, with letters, figures and conventional skull and bones in post office red colour duly painted and written with enamelled paint fixed with and including MS clamps, bolts and nuts of approved size for LT, 20x15 cm size complete all as specified and directed.
50
-
-
M&L for repair of LED street light/flood light of capacity 45 watt to 110 watts including replacement of unserviceble/burnt drivers,AC/DC converters of suitable capacity, power protector, rectifier, mosfet, condenser, transformers, diods, capacitors, LED bulbs ,resistors,relays, connectors, soldering of connections as per requirement, replacement of connecting cables,replacement of control chips complete including testing and commissioning including dismantling from existing pole and refixing the same place . The rate includes the rate of spares/tools required for repair of lights, replacement of twisted cables of 3 core for connection of lights with supply etc.
150
-
-
Supply, erection and connection new Pre- streessed concrete poles 102 mm x 172 mm at top and 102 mm x 279 mm at bottom 9.0 mtrs long including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2" height letters complete all as specified and directed.
50
-
-
Excavation in trenches n. exc 1.5 mtr wide and not exceeding 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
216
-
-
Excavation in trenches in any type of soil not exceeding 1.5 mtrs wide and exceeding 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed.
5.4
-
-
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick after cable are laid and tested complete all as specified and directed.
131.68
-
-
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
89.72
-
-
M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
8700
-
-
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed.
70.2
-
-
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge.
5.4
-
-
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge.
19.35
-
-
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge.
2.4
-
-
M&L for painting of steel tubuler 11/9 mtr poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint andalso including numbering of poles with white paint are located on different locations in HT over head lines complete all as specified and directed by Engr-in-Charge.
2000
-
-
M & L for painting of steel cross arm, bracing supports of 11/9 mtr PCC poles any type incl flat iron clamps, D clamps, stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint incl prepration old painted surface marking with alternator white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint, numbering of poles on HT overhead line complete all as specified and directed.
1000
-
-
S&f outdoor type bus bar box of size 60cm x 45 cm x60cm having 04 Nos aluminum bus bar of capacity 125 Amp fixed on porcelein insulators separately ,MS cubical LT panel, fabricated with 3.0 mm thick MS sheet for outer and 1.6 mm thick for inner shell & zinc metal powder coated paint over a coat of primer red oxide and reqd capacity of aluminium bus bar channel insulated with heat shrinkable sleaves and mounted on epoxy insulator of reqd size in conical type, double door be provided with proper hinged incl locking arrangements, provn of suitable cable ducts at bottom with adequate size of copper lugs be properly bunched. The cubical panel be fixed with angle iron frame with PCC (1:2:4) type B1 foundation of reqd size.
4
-
-
M&L for replacement of aluminum bas bar as per sample at LT panel at various locations including taking down of the exisiting u/s bus bar after diamantling of connections and replacing new bus bar,testing and commissioning of the panel. The capacity of the bus bar must be 1.5 times capacity of incoming MCCB/capacity as per installed at site, aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator .The rate includes rate for necessary frame work in bus bar, rate of insulators, nut bolts,connecting copper lugs etc complete all as specified and directed.
20
-
-
Reinforced cement concrete (normal mix) type B0 1:2:4 (12.5 mm graded aggregate) for duct slab for cover of ducting including demolition of old damaged duct cover all as directed by Engr-in-Charge.
2
-
-
M&L reinforcement 6 mm and over using TMT bars cut to length bent to shape as required including cranking bending spirally for hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia or securig with clips etc complete all as specified and directed.
75
-
-
S & F in replacement of MCCB, AC 415 Volt 3 phase, 4 pole 100 Amps capacity with breaking capacity 25 KA with magnetic tripping system against over load and short circuit conditions in the existing panel with suitable connecting terminals at site complete all specified and directed. Make : Havells/ Legrand/ ABB/L&T.
10
-
-
S & F in replacement of MCCB, AC 415 Volt 3 phase, 4 pole 160 Amps capacity with breaking capacity 25 KA with magnetic tripping system against over load and short circuit conditions in the existing panel with suitable connecting terminals at site complete all specified and directed. Make : Havells/Legrand/ ABB/L&T.
8
-
-
S & F in replacement of MCCB, AC 415 Volt 3 phase, 4 pole 200 Amps capacity with breaking capacity 36 KA with magnetic tripping system against over load and short circuit conditions in the existing panel with suitable connecting terminals at site complete all specified and directed. Make : Havells/Legrand/ ABB/L&T.
8
-
-
S & F in replacement of MCCB, AC 415 Volt 3 phase, 4 pole 400 Amps capacity with breaking capacity 36 KA with magnetic tripping system against over load and short circuit conditions in the existing panel with suitable connecting terminals at site complete all specified and directed. Make : Havells/Legrand/ ABB/L&T.
6
-
-
S & F in replacement of MCCB, AC 415 Volt 3 phase, 4 pole 630 Amps capacity with breaking capacity 50 KA with magnetic tripping system against over load and short circuit conditions in the existing panel with suitable connecting terminals at site complete all specified and directed. Make : Havells/Legrand/ ABB/L&T.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements