Tripura State Electricity Corporation Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Tripura State Electricity Corporation Limited - TSECL Tender
Eprocure
Opening Date3 Jul 2019
Closing Date18 Jul 2019
Tender Amount₹ 32,10,987
Costs
EMD
₹ 64,220Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_POWER_4819_1Bid Award Id
ViewTender No
31/AGM (DPaC)/AGMC(UG)/TSECL/2019-20 dt 04-06-2019Tender Authority
Tripura State Electricity Corporation Limited ViewPurchaser Address
-Website
http://https://www.tsecl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply of 100mm dia heavy duty G.I pipe (C-Class) as per ISS 1239 of different length as per engineering requirement including laying of 3-phase, 3-core, 6.35/11 KV, 185 sqmm XLPE insulated & insulation screened Aluminium Power Cable below the road surface through GI pipe by all terrain by drilling horizontalling & mannually digging along & accross the road without effecting the exixting road surface upto a depth of 1200mm or as per site requirement.
24
-
-
Supply of PE 80, PN 6, 110 mm O.D, minimum wall thickness 7.7 HDPE pipe of above mentioned specification of HDPE Pipe different length as per engineering requirement including laying of XLPE cable through G.I pipe above ground level for riser to Pole and other places where required etc as required and fitting fixing of pipe to pole with the help of Crossarm, Clamp, Nuts & Bolts for 3-phase 3-core 6.35/11 KV 185sqmm. XLPE insulated conductor & insulation screened Aluminium Power Cable.
9
-
-
Supply & making of Cable end joints for XLPE power cable:- Outdoor type end joint suitable for 3 core, 6.35/11 KV, 185 mm² XLPE Cable.
12
-
-
Stright through joint suitable for 3 core, 6.35/11 KV, 185 mm² XLPE Cable.
1
-
-
Supply of T-shaped Pillar for cable line ID marking engraved with caption '11 KV UG CABLE LINE' made of pre-cast RCC of size, [Pillar- 3.0 x.0.33 x 0.33 ft & T-section- 1.0 x.0.33 x 0.33 ft] by excavating earth in/c painting of engraded caption in black colour on yellow background as per technical requirement.
20
-
-
Supply & erection of Earthing set as per ISS: 3043 of 1966 alongwith upto date ammadement, having 2.5 mtr long perporated heavy duty G.I. pipe (ISI marked), 40 mm dia with holes i/c a pair of 50X6mm GI flat and 12mm, 65mm long nuts & bolts and excavation, refilling with alternate layer of salt & charcoal etc as reqd. as per direction of Engg -in charge as per REC specefication.
15
-
-
PART "A":- ERECTION OF ELECTRICAL WORK
-
-
-
Erection of 4 way (1 incoming and 3 outgoing feeder) H.T KIOSK / 11KV outdoor type feeder piller made of 10SWG MS Sheet complete with aluminium busbar , HT insulator etc as required provided with locking system and painting to be fitted on structure of M S Angle (50X50X6mm) and M S Flat (40X6mm) including supply of M S Angle and Flat as required and concreting of ratio 1:2:4 with excavation of earth centering shuttering & disposal of excess soil.
3
-
-
Laying and Commissioning of 3-phase 3-core, 6.35/11 KV 185 sqmm XLPE insulated Aluminium power cable in trenches (Dimention: 500mm width & 1200mm depth excluding specific locations where this is likely to vary on higher side) including : (a) Formation of trench by excavation of soil (b) Supply and spreading of sand in 2 (two) layers each of 150mm thick one on trench bed and the other over cable laid (c) Supply and laying double layer of consolidate plain flat brick soling over the 2nd layer of spreaded sand (d) Refilling of excavated earth over the flat brick soling work upto the ground level and coiling of excess cable below the earth surface at a depth of minimum 1200mm with protecting by double layer bricks soiling as per design, specefication & engineering requirement of TSECL.
1300
-
-
Erection of PE 80, PN 6, 110 mm O.D, minimum wall thickness 7.7 HDPE pipe of above mentioned specification of HDPE Pipe different length as per engineering requirement including laying of XLPE cable through G.I pipe above ground level for riser to Pole and other places where required etc as required and fitting fixing of pipe to pole with the help of Crossarm, Clamp, Nuts & Bolts for 3-phase 3-core 6.35/11 KV 185sqmm. XLPE insulated conductor & insulation screened Aluminium Power Cable.
9
-
-
laying of 100mm dia heavy duty G.I pipe (C-Class) as per ISS 1239 of different length as per engineering requirement including laying of 3-phase, 3-core, 6.35/11 KV, 185 sqmm XLPE insulated & insulation screened Aluminium Power Cable below the road surface through GI pipe by all terrain by drilling horizontalling & mannually digging along & accross the road without effecting the exixting road surface upto a depth of 1200mm or as per site requirement.
24
-
-
Making of Cable end joints for XLPE power cable:- Outdoor type end joint suitable for 3 core, 6.35/11 KV, 185 mm² XLPE Cable.
12
-
-
Outdoor type end joint suitable for 3 core, 6.35/11 KV, 185 mm² XLPE Cable.
12
-
-
Stright through joint suitable for 3 core, 6.35/11 KV, 185 mm² XLPE Cable.
1
-
-
Erection of 9.0 mtr long PCC pole direct in earth in/c excavation, refilling & ramming etc. as required [1/6th of the pole to be embeded in earth] [ PCC pole Will be Supplied by TSECL].
4
-
-
Erection of triple pole, 3 phase, 12 KV, 200 Amps manually Gang opereted Air break switch, 3 post verticle type Single break, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS with supply of clamps, nuts & bolts, bimetalic lugs etc as reqd. as per direction of Engg -in charge.(Gang opereted Air break switch will be supplied by TSECL)
2
-
-
Erection of 9 KV, 5 KN, metal oxide gapless surge trype Lightening Arrester suitable nominal system voltage of 11 KV, 3 phase, 50 Hz, AC system, creepage distance 600 mm, confirming to ISS : 3070/1985.( LA will be supplied by TSECL)
6
-
-
Erection of T-shaped Pillar for cable line ID marking engraved with caption '11 KV UG CABLE LINE' made of pre-cast RCC of size, [Pillar- 3.0 x.0.33 x 0.33 ft & T-section- 1.0 x.0.33 x 0.33 ft] by excavating earth in/c painting of engraded caption in black colour on yellow background as per technical requirement.
20
-
-
Laying & stringing of ACSR 6/1/2.59mm or AASC equivalent conforming to ISS 398(Part-II) 1996 with latest amendments if any in/c hoisting, binding, jumpering etc as per direction of Engineer-in-charge. (ACSR will be supplied by TSECL)
0.2
-
-
Laying & stringing of 8/4 Swg G. I. wire as per ISS : 280/1978 amended latest with heavy coating as per ISS : 4826 / 1968 of tensile strength 55 to 95 Kgf / mm i/c fastening with cross arm & metallic parts for earth contunity wire & metal parts to earth electrode as per direction of Engineer In-charge. (GI will be supplied by TSECL)
20
-
-
Erection of polymer Pin insulator for 11 KV system with mechanical strength 10 KN confirming to ISS: 731/1971 on hot dip galvanised M.S. forged 11 KV G.I. pin complete with galvanised hexagonal nuts, G.I. flat washer & G.I. pin washer confirming to ISS: 2486 (P-II) / 1974 in/c supply of G.I. pin etc as reqd.
12
-
-
Erection of Polymeric Disc insulator Ball & Socket type for 11KV System (EMS-45KN) confirming to ISS:731/1971 in angle and dead end locations inluding tension fittings of EMS-45KN to accommodate the revelent ACSR conductor size along with nuts and bolts, washer etc as required in complete as per dirction of Engineer -in charge. (Pin will be supplied by TSECL)
21
-
-
Erection of painted Stay set conplete direct in earth complete with 16 mm dia, 1800 mm long stay rod, anchor plate of size 300 X 300X 8mm, turn buckle of length 356 mm, with 300 mm threaded adjustable 16 mm dia M.S. rod & thimble in/c supply of 11 KV guy insulator as per IS specification, hot dip (heavy duty) galvanisrd stay stranded wire, 7/2.5 mm2, grade-IV as per ISS:2141 / 1979 having minimum tensile strength 700N with zinc coating (heavy type coating confirming to IS:4826/1979, weight 260 kg / km, fastened with stay clamps in/c supply of M.S clamp, nuts & bolts etc as required. (Stay set will be supplied by TSECL)
4
-
-
Erection of 2.80mtr long M.S Bracket made of 75x40x40x6 mm M.S. channel in/c fabrication alongwith drilling holes (5/8"), Supply of required nos of Clamps by MS Flat (Size: 50X6mm), required length of Nuts & Bolts (5/8") etc as reqd for fitting & fixing on pole i/c applying priming coat with ready mixed primer of approved quality on Bracket i/c painting (two or more coats) with Aluminium paint of approved quality to give an even shape as per direction of Engg -in charge. (MS channel will be supplied by TSECL)
10
-
-
Erection of 2.80mtr long M.S Bracket made of 65X65X6mm mm M.S. Angle in/c fabrication alongwith drilling holes, Supply of required nos of Clamps by MS Flat (Size: 50X6mm), required length of Nuts & Bolts (Size: 5/8") etc as reqd for fitting & fixing on pole i/c applying priming coat with ready mixed primer of approved quality on Bracket i/c painting (two or more coats) with Aluminium paint of approved quality to give an even shape as per direction of Engg -in charge. (MS Angle will be supplied by TSECL)
6
-
-
Supply & erection of Earthing set as per ISS: 3043 of 1966 alongwith upto date ammadement, having 2.5 mtr long perporated heavy duty G.I. pipe (ISI marked), 40 mm dia with holes i/c a pair of 50X6mm GI flat and 12mm, 65mm long nuts & bolts and excavation, refilling with alternate layer of salt & charcoal etc as reqd. as per direction of Engg -in charge as per REC specefication.
15
-
-
PART "B":- DISMENTALLING WORK
-
-
-
Uprooting of 3-phase, 3-core, 6.35/11 KV, 120sqmm/185sqmm XLPE insulated & insulation screened Aluminium Power Cable Conductor in/c proper stacking at sub-divisional store.
500
-
-
Dismentalling of PCC Pole 8.omtr long in/c proper stacking at sub-divisional store
6
-
-
Dismentalling of Steel tubular polr 8.0mtr long in/c proper stacking at sub-divisional store
1
-
-
Dismentalling of Steel tubular polr 9.0 mtr long in/c proper stacking at sub-divisional store
4
-
-
Dismentalling of ACSR 6/1/3.35sqmm in/c proper stacking at sub-divisional store
1.3
-
-
Dismentalling of LT Shackle Insulator in/c proper stacking at sub-divisional store
30
-
-
Dismentalling of GO and stacking at sub-divisional store
2
-
-
Disconnection and reconnection of 1-Phase street light
6
-
-
Disconnection and reconnection of 3-Phase service connection
2
-
-
PART "C":- CIVIL WORK
-
-
-
Earth work in excavation by mechanical means ( Hydraulic excavator / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
45
-
-
Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
45
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -
All work up to plinth level:- 1:3 :6 (1cement :3 fine sand : 6 Graded stone aggregate 40mm nominal size)
2.25
-
-
First class brick work in foundation and plinth including cost of all materials as required complete:- In cement mortar 1 :6 ( 1 cement :6 fine sand )
6
-
-
12 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete:- In cement mortar 1 : 5 ( 1 cement : 5 fine sand )
30
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
45
-
-
Providing and laying dry flat brick flooring in cement mortor including cement slurry.
150
-
-