BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Northeast Frontier Railway - NFR Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Ireps
Opening Date12 Mar 2025
Closing Date7 Apr 2025
Tender Amount₹ 1,52,05,596.65 
Notes
Download

Costs

Summary

Augmentation Of Power Supply To Location Huts,shunting Neck, Street Lights At Pf And Approach Road Along With Upgrdataion Of Substaion At Different Service Building And Other Ancillary Works Under The Jurisdiction Of Sse/p/agtl.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & fixing of HDPE pipe of out side dia 50mm, 6kgf/cm2, 6.0 mtr each length 4 conforming to IS : 4984/1995, clamped with bracket by 50x5mm MS flat clamp with nuts & bolts MS of size 50x12mm as per direction at site.

500

59

29965

... More
Supply, fitting, fixing, connection & commissioning of 18/20 watt LED indoor fitting complete set with LED tube and other accessories. The fitting shall be connected by 1.5 sq mm flexible copper wire through pvc pipes/casing as required at site.

30

322

9685.2

... More
Supply and wiring of exhaust fan point through good quality hard PVC casing with associated accessories for surface type wiring by 1.5 mm sq single core PVC insulated flexible copper 6 wire with earth continuity by 16 SWG bare copper wire and flush type 5/6 amp controlling switch to be provided on hard plastic moulded board . Exhaust fan connection shall be done through ceiling rose. Casing shall be fixed on the wall / ceiling by MS (6x40 mm) screw at an interval not more than 300mm

10

246

2468.1

... More
Supply & fixing of heavy duty exhaust fan 305/300mm sweep including all fixing accessories with wall cutting & frame louver shutter. All consumables regarding fixing arrangement will be supplied by the contractor as per the direction of engineer in charge at site.

22

1442

31739.4

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 8 aluminum conductors of different sizes (4 core 50 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

3000

30

91350

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling 9 the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

3000

50

150150

... More
Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an 10 effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM).

60

1283

77013

... More
Supply & fixing of HDPE pipe of out side dia 50mm, 6kgf/cm2, 6.0 mtr each length conforming to IS : 4984/1995, clamped with bracket by 50x5mm MS flat clamp with nuts & bolts MS of size 50x12mm as per direction at site.

600

59

35958

... More
Supply, fitting, fixing, testing, installation & commissioning of 45 Watt outdoor type LED street light fitting made up of pressure die cast aluminum housing with high power LED as 12 lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. The street light must be conforms to the technical specification i.e. attached in the tender document. The whole work shall be executed as per direction of Engineer in charge at site.

500

3995

1997565

... More
Supply & fitting fixing of 6/8 SWG GI wire for connection as earth continuity wire from earth electrode to any electrical installation in different location as per instruction of site engineer incharge for earth continuity to street light poles 14

5000

20

104000

... More
supply, fitting fixing of junction box for 4 core x 25 sq mm cable for street lights

180

2600

468000

... More
Supply, fitting fixing of Outddor feeder piller box consisting 63 amp copper busbar and MCCB : 63 amp ,4pole,25 KA

20

8716

174327.6

... More
Supply, erection, testing and commissioning of 3 phase, 11/0.433KV, 3 star, 250 KVA (outdoor type), step down, Dyn11 copper wound transformer conforming to IS:1180(Part-1):2014 with first filling of insulating oil (As per IS 335) complete set i.e. Name & Diagram plate, lifting lugs, oil filling hole with plug,radiator,conservator tank, Drain valve, earthing terminal, Silicagel breather, Arcing horn, Air release plug etc. with all fittings and accessories including re-connection of all associated cables, ACSR conductor, etc & loading on foundation pad for successful commissioning of Transformer. The transformer neutral connections are to be connected with two nos. copper strip of 16 size (50x6) mm of adequate length and shall be connected by suitable Size/types of nut/bolts to the earth system. Body earthing of transformer shall also be done with two nos GI strip of size (40x6) mm & connected by suitable size/types of nut/bolts to the earth system. (All necessary materials required for successful commissioning of transformer on the pad shall be provided by the contractor).The entire work to be executed as per direction of Engineer in charge at site. OEM Test,warranty certificate shall be Technical particular as per IS:2026 and other relevant IS should be furnished. Transformers covered by this specification shall, unless otherwise specified be built to conform to the latest Indian Electricity Rules, wherever applicable and the requirements of latest issue of IS: 1180 and 2026, CBIP standards and other IS (all as per latest issues).

1

391813

391813.27

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 17 aluminum conductors of different sizes (4 core 150 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

200

30

6090

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling 18 the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

200

50

10010

... More
Supply and erection of 80 mm dia thickness not less than 4.0 mm, 4 mtr. long G.I.pipe 19 earthing including connection to transformer with G.I.Flats size 25x5mm including construction of earth pit, RCC earth cover slab 1/2" thick and earth continuity as per CEE/MLG's diagram CEE/STD/1.The whole work should be executed as per EIC at site

4

3153

12612.68

... More
Supply and fixing of HDPE pipe of out side dia 110mm, 6kgf/cm2, 6.0 mtr each length 20 and threaded to match with Tee, Elbow, Union and Socket etc conforming to IS 4984/1995 clamped with pole/truss/bracket made of galvanised flat of size 50x6mm with galvanised nuts & bolts of size 50x12mm as per direction of Engineer In Charge at site.

150

344

51637.5

... More
Supply, fabrication, erection of dust & vermin proof, rodent proof, chemically treated, 21 dry powder coated cubical 8 way double door panel board made of 16SWG CR/MS sheet with electrolytic grade 4 pole 300A copper bus on suitable size MS angle frame complete with cable alleys, metering module with allinternal connection to be done by suitable size copper wire/strip connection comprising the following :-

1

73940

73940

... More
a. Supply and installation of MCCB 160 Amps 4pole 36KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IS: 13947-II. 2nos

2

20870

41740

... More
b. Supply and installation of Onload Change Over Switch 200A, 4Pole (Manual- Transfer-Swicth ) without enclosure

2

14700

29400

... More
c. Supply and installation of MCCB 125 Amps 4pole 25KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IS: 13947-II. 2nos

2

15900

31800

... More
d. Supply & erection of MCCB 63 A, 4-pole, 25KA, Ics=100% Icu, conforming to IS:132947-II. 2nos

2

12600

25200

... More
Supply & erection of 11 KV Gang Operated Air break off load disconnecting switch -400Amp 3 pole rocking type with operating handle and fixing of the same with pole by 2200 mm long MS channel ( 75x40x40x5) mm with ( 50x5) clamp with necessary nut/bolts.etc. The whole work shall be executed as per direction of Engineer in charge at site. Each pole consist of galvanised steel base, HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arching horns of adequate sections to break magnetising current of the transformer horizontal Gi pipe of adequate length for phase separation and 25mm dia, 3.65mm thickness GI pipe of adequate length for operation from ground level and operating handle complete in both On & OFF positions as per direction of Engineer In charge at site.

6

8817

52905

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 27 aluminum conductors of different sizes (4 core 50 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

500

30

15225

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling 28 the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

400

50

20020

... More
Supply and erection of earthing by 80 mm GI pipe, 3 mtr long 4.05mm thickness 29 including construction of earth pit, RCC earth cover slab with filling/mixing of salt, charcoal etc of required quantity and earth continuity by 25x3mm GI strip with GI nuts bolts washer etc. including welding, earth resistance flag etc. as per Drg. No. NFR/CEE/CON/GS/10(earthing system)/04/2016 & as per Technical Specification No. NFR/ELECT/GS/10 (EARTHING SYSTEM).

15

3153

47297.55

... More
Supply, Installation, Testing and Commissioning of HDPE Pipe 160 mm. Nominal Dia., 6.2 mm thickness conforming to IS -4984- 1995.

400

392

157112

... More
Supply, fabrication, erection of dust & vermin proof, rodent proof, chemically treated, 31 dry powder coated cubical 8 way double door panel board made of 16SWG CR/MS sheet with electrolytic grade 4 pole 300A copper bus on suitable size MS angle frame complete with cable alleys, metering module with allinternal connection to be done by suitable size copper wire/strip connection comprising the following :-

3

73940

221820

... More
a. Supply and installation of MCCB 300 Amps 4pole 36KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IS: 13947-II. 2nos

6

35780

214680

... More
b. Supply and installation of Onload Change Over Switch 400A, 4Pole (Manual- Transfer-Swicth ) without enclosure

3

31800

95400

... More
c. Supply and installation of MCCB 200 Amps 4pole 25KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IS: 13947-II. 2nos

6

12990

77940

... More
d. Supply & erection of MCCB 125 A, 4-pole, 25KA, Ics=100% Icu, conforming to IS:132947-II. 2nos

6

11240

67440

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 36 aluminum conductors of different sizes (4 core 95 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

400

30

12180

... More
Supply and fixing of HDPE pipe of out side dia 110mm, 6kgf/cm2, 6.0 mtr each length and threaded to match with Tee, Elbow, Union and Socket etc conforming to IS 4984/1995 clamped with pole/truss/bracket made of galvanised flat of size 50x6mm with galvanised nuts & bolts of size 50x12mm as per direction of Engineer In Charge at site.

-

-

37

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling 38 the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

350

50

17517.5

... More
Supply of high mast tower 12 Mtr height with its accessories. Mast shall be in one section, hot dip galvanized, Ring size minimum 60mm OD, minimum galvanization = 85micron. suitable for wind Zone- 4 air velocity as per IS-875, and sheet thickness should be 6 mm including accessories like head frame, steel wire rope 6 mm dia(7/19 construction), trailing cable, double drum 39 winch, galvanized lantern carriage arrangement suitable for 6 luminaries symmetrically boxes and lightning finial. The mast shall have anintegral power tool installed inside the base compartment for its operation. (Bidder must submit wind tunnel test certificate as per IS-875 as well as Authorization letter from principal manufacturer after issue of LOA and before execution of work. Warranty certificate of tower, Type test certificate & quality assurance plan certificate, Design of foundation plan and drawing from OEM to be furnished before execution of work.)

2

83610

167220.98

... More
Supply, fitting & fixing of foundation bolts minimum 8 nos, minimum bolt dia 25 mm and minimum bolt length 750 mm manufactured from special steel along with its nuts, washers, anchor plates of minimum thickness 20 mm and templates complete set.

2

2530

5060.66

... More
Supply, fitting, fixing, testing & commissioning of single dome aviation obstruction lights.

2

2228

4456.48

... More
Design, supply ,erection and Construction of suitable RCC foundation (as per manufacturer specification) with cc ratio in proportion 1:2:4 (M15 Concrete grade)with stone chips of 42 maximum aggregate size 20 mm and less including cement, sand.etc for the high mast tower as per the soil bearing capacity at 10 ton per sq mtr at site with all materials and labour and for control panel including Erection and commissioning of high mast tower and also control panel with the help of suitable equipment and wiring of luminaires with all wiring materials and labour.

2

71612

143225.1

... More
Supply, testing & commissioning of Control panel(outdoor type) with drive switch 43 housing 32 Amps TPN MCB incoming, single dial timer contractor circuit for the automatic control of luminaires, outgoing terminals and control circuit for the power tool motor complete set .The control panel shall also consist of astronomical time switch with accessories for automatic switching of luminaries

2

11303

22607.16

... More
Supply, fitting, fixing, connection & commissioning of 160watt LED flood light,IP-65 fitting complete set with pressure die cast aluminium housing and other accessories.

34

7684

261289.66

... More
Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an 45 effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM).

2

1283

2567.1

... More
supply,fitting fixing of feeder piller box consisting 200 amp copper busbar and MCCB :100 amp ,4pole,25 KA

2

16593

33187

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

700

50

35035

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 48 aluminum conductors of different sizes (4 core 120 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

970

30

29536.5

... More
HDD machine for horizontal boring , across railway embankment at a minimum 49 distance of 6mtr. From the embackment GL and depth. Of 2.0mtr. Below the GL with preparation of the site for boring by placing of pipes for electric cable protection through contactor own arrangement for 150 mm dia hole as per direction of site Engineer

80

6122

489760

... More
Supply & laying of class LA type CI pipe of size 150 mm of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989, 2m. below ground level. As per direction of Engineer Incharge at site.

80

894

71575.2

... More
Supply, fitting, fixing and laying of 90 mm Dia HDPE pipe along with all the 51 accessories like socket, bend, couplers etc. of working pressure of 6 Kgf per sq cm Conforming to IS 4984/1995,clamped with bracket wall thickness 7.6mm and threaded to match with GI pipe of Tee, Elbow, Union & Socket etc for laying of Welding line cable protection.

700

204

142870

... More
Supply, fabrication, erection of dust & vermin proof, rodent proof, chemically treated, 52 dry powder coated cubical 8 way double door panel board made of 16SWG CR/MS sheet with electrolytic grade 4 pole 300A copper bus on suitable size MS angle frame complete with cable alleys, metering module with allinternal connection to be done by suitable size copper wire/strip connection comprising the following :-

1

73940

73940

... More
a. Supply and installation of MCCB 160 Amps 4pole 25KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IS: 13947-II. 2nos

2

12465

24930

... More
b. Supply and installation of Onload Change Over Switch 200A, 4Pole (Manual- Transfer-Swicth ) without enclosure

1

14700

14700

... More
c. Supply and installation of MCCB 125 Amps 4pole 25KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IS: 13947-II. 2nos

2

11240

22480

... More
d. Supply & erection of MCCB 63 A, 4-pole, 25KA, Ics=100% Icu, conforming to IS:132947-II. 2nos

2

8795

17590

... More
supply,fitting fixing of feeder piller box consisting 200 amp copper busbar and MCCB :100 amp ,4pole,25 KA

2

18964

37928

... More
Supply of high mast tower 12 Mtr height with its accessories. Mast shall be in one section, hot dip galvanized, Ring size minimum 60mm OD, minimum galvanization = 85micron. suitable for wind Zone- 4 air velocity as per IS-875, and sheet thickness should be 6 mm including accessories like head frame, steel wire rope 6 mm dia(7/19 construction), trailing cable, double drum 58 winch, galvanized lantern carriage arrangement suitable for 6 luminaries symmetrically boxes and lightning finial. The mast shall have anintegral power tool installed inside the base compartment for its operation. (Bidder must submit wind tunnel test certificate as per IS-875 as well as Authorization letter from principal manufacturer after issue of LOA and before execution of work. Warranty certificate of tower, Type test certificate & quality assurance plan certificate, Design of foundation plan and drawing from OEM to be furnished before execution of work.)

3

83610

250831.47

... More
Supply, fitting & fixing of foundation bolts minimum 8 nos, minimum bolt dia 25 mm and minimum bolt length 750 mm manufactured from special steel along with its nuts, washers, anchor plates of minimum thickness 20 mm and templates complete set.

3

2530

7590.99

... More
Supply, fitting, fixing, testing & commissioning of single dome aviation obstruction lights.

3

2228

6684.72

... More
Design, supply ,erection and Construction of suitable RCC foundation (as per manufacturer specification) with cc ratio in proportion 1:2:4 (M15 Concrete grade)with stone chips of 61 maximum aggregate size 20 mm and less including cement, sand.etc for the high mast tower as per the soil bearing capacity at 10 ton per sq mtr at site with all materials and labour and for control panel including Erection and commissioning of high mast tower and also control panel with the help of suitable equipment and wiring of luminaires with all wiring materials and labour.

3

71612

214837.65

... More
Supply, testing & commissioning of Control panel(outdoor type) with drive switch 62 housing 32 Amps TPN MCB incoming, single dial timer contractor circuit for the automatic control of luminaires, outgoing terminals and control circuit for the power tool motor complete set .The control panel shall also consist of astronomical time switch with accessories for automatic switching of luminaries

3

11303

33910.74

... More
Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an 63 effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM).

10

1283

12835.5

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 64 aluminum conductors of different sizes (4 core 120 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

900

30

27405

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling 65 the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

900

50

45045

... More
HDD machine for horizontal boring , across railway embankment at a minimum 66 distance of 6mtr. From the embackment GL and depth. Of 2.0mtr. Below the GL with preparation of the site for boring by placing of pipes for electric cable protection through contactor own arrangement for 150 mm dia hole as per direction of site Engineer

160

6122

979520

... More
Supply & laying of class LA type CI pipe of size 200 mm of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989, 2m. below ground level. As per direction of Engineer Incharge at site.

160

1739

278270.4

... More
supply,fitting fixing of outdoor type feeder piller box consisting 400 amp copper busbar and MCCB :300 amp ,4pole,50 KA

2

45395

90790

... More
Supply, erection, testing & commission of 100 KVA, 11/0.433 KV,star rated, 50Hz,3-ph, ONAN cooled, vector groupDyn11,off circuit tap changer having range +5%to -5% in steps of 2.5% each with firstfilling of oil, copper wound, outdoor type,Delta/Star, stepdown (Outdoor 69 typetransformer) distribution transformer with2.32 KW load loss at rated voltage andfrequency corrected for 750Cwindingtemperature fitted with a rating plate, twoearthing terminals, lifting lugs, drain valvewith plug or cover plate, dehydrating silicagel breather, arching horn, first filling of oilas per IS : 335, oil level indicator withminimum marking, rollers, explosion vent,oil filling hole with cover and allaccessories.

2

290280

580560

... More
Fabrication, design, supply, erection. testing & commissioning of floor mounted LT Main Control panel 8 way outdoor type MCCB consisting of I) 125 AMP 4 pole MCCB- 01 nos, 36KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IEC 60947-2 II) 100 amps 4 pole MCCB -2 nos. 25KA, Ics=100% Icu, conforming to IEC 60947-2 iiI) 63 amps 4 pole MCCB -2 nos. , 70 25KA, Ics=100% Icu, conforming to IEC 60947-2. IV) 200A ams 4 pole COS, 415V -01 nos., (Manual- Transfer-Swicth ) without enclosure. with copper bus bar 250 Amp., incicator lamp ammeter, voltmeter etc. - The panel shall fabricated from 2 mm thick sheet steel, powder coated, dust and vermin proof duly wired with PVC insulated copper wire confirming to IS: 694. The panel shall also comprise of suitable size & quantity of MCCB door interlocks, spreader link terminals, Aux contact, CT reverse current relay, led ndicating lamps, 6A control MCB. The busbar shall be of electrolytic grade copper of size (50 x6) mm for 3 phase neutral. The panel to be manufactured by any CPRI approved.

1

298140

298140

... More
Supply & erection of PCC/RCC works for foundation of transformer. excluding the cost of cement. 1:3:6 M-10 ( 1 cement : 3 sand : 6 graded stone aggregating 20mm normal size). Ordinary Portland cement grade : 53 Grade. (For two nos transformer)

1

60709

60709.81

... More
Fabrication, design, supply, erection & commissioning of fencing ( for transformer pad) with MS angle of size (75x75x 5) mm. The size of fencing shall be 5X4.5 mtr & height of fencing 2.5 mtr. above Ground Level. The MS angles shall be put to a depth of 0.5 mtr. Below GL. The MS angles will also be used for top & bottom runner of fencing on 3 sides.( Total quantity of MS angles to be used in the work shall not be less than 68 mtr.) There shall be CC foundation block for supporting the MS angle structure. The size of each CC 18 1 Job 29658.87 At Par 29658.87block shall be 0.250mtr.X 0.250mtr. and depth of each CC block shall be 0.5 mtr. Below GL and height of each CC block shall be 0.250mtr. above GL( There shall be a total of seven7 nos. of such CC blocks in the said work). CC 72 shall be in proportion 1:2:4 with stone, chips of maximum aggregate size 20mm and less including cement, sand etc. The fencing shall be covered on all sides by GI flat of size (25X3) mm in square mesh design.(total quantity of GI flat to be used in the work shall not be less than 483.25mtr.) The MS angle and GI flat are to be welded properly with each other to make the fencing strong. There shall also be a provision of two part/double leaf hinged door locking arrangement on one side of the fencing. The door shall also be fabricated from MS angles of size (75X75X5)mm and GI flat of size (25X3) mm in square mesh design and fitted with MS sliding door bolts bright satin finish or black stone enameled of size(300X16)mm with nuts/screws etc. The MS angles shall also be cleaned of any dust/oily/grease impurities and then painted by one coat of primer over which two coats of aluminum paint of any ISI marked quality. The entire work to be executed as per the direction of engineer in charge at site.

1

22534

22534.81

... More
Fabrication, design, supply, carrying and erection of 12 mtr height swaged type (410- SP-66) G.I. Tubular pole (including supply and fixing of base plate and pole cap) by earth digging to a depth of 1/6th of the pole height with CC foundation in ratio 1:2:4 by cement ,sand and stone of nominal size 20 mm & the size of the CC block will be 30 cm dia with height upto the pole depth below GL and 30 cm above GL for muffing. The pole shall be hot dip galvanized with an average 73 coating thickness of 70 microns conforming to IS:2629/IS:2633/IS:4759. The pole swaging, welding and base plate welding to be done as per IS:2713. The material construction(pipe) shall confirm to IS:1161/IS:1239 and shall be able to withstand maximum wind speed conforming to IS:875. Anti- climbing device by barbed wire upto 2.5 mtr height with necessary GI clamp/nut/bolts, etc has to be provided.Danger Board of size 8"X6" fixed with suitable GI clamp has to be provided showing the voltage grade,skull etc. The whole work shall be executed as per direction of Engineer in charge at site

26

23680

615683.12

... More
Supply, installation, testing and commissioning of lightning arrestor thyrite type 74 conforming to IS:3070 - Part III/1993 (Latest Version) suitable for protecting 11 KV installation including connection with earth pit by 25 mm x 6 mm GI strip and with overhead by ACSR conductor. The whole work shall be executed as per direction of Engineer in charge at site.

2

6022

12044.58

... More
Supply and fixing testing and commissioning of HT heat shrinkable type outdoor and joint kit suitable for single core 11KV grade X1.PE 150/120/185 sq.mm cable including.

6

4020

24120

... More
Supply and fixing testing and commissioning of LT heat shrinkable type outdoor and termination kit suitable for single core 1.1KV grade X1.PE 150/120/95 sq.mm cable including.

4

1082

4328

... More
Supply & erection of 2P composite polymer 11 KV ball & socket type Disc insulator with minimum creepage distance 320mm & sectional length 300mm made of one piece injection 77 molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting

26

707

18399.68

... More
Supply & erection of 2P composite polymer 11 KV Pin insulator with minimum 78 creepage distance 340mm & sectional length 235mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting

56

512

28702.8

... More
Supply & fixing of GI channel of size 75x40x40x6mm bracket of following size 79 clamped with above pole made by MS flat 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting(1200 mm long bracket X 5 =6000 mm).

70

685

48013.7

... More
Making of cable trench dimension 300 mm wide and 1000mm deep by excavation of 80 earth. The cable shall be protected by laying of brick in 3 sides with filling of sand as per the direction of Engineer in charge at site (Outside track crossing) and backfilling of earth/ ballast. The work to be executed as per enclosed specification

200

50

10010

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 81 aluminum conductors of different sizes (1 core 240 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site. 82

300

30

9135

... More
Supply, laying, fitting and fixing with clamping arrangement of HDPE pipe 125 mm

100

435

43520

... More
Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an 83 effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM).

12

1283

15402.6

... More
Supply, fitting, fixing, testing & commissioning of 11 KV 400 amps GO-DO set with 84 operating handle and fixing of the same with pole by 2200 mm long MS channel ( 75x40x40x5) mm with ( 50x5) clamp with necessary nut/bolts.etc. The whole work shall be executed as per direction of Engineer in charge at site.

3

7200

21600.18

... More
Supply, drawing and stringing of ACSR conductor of size 6/1/2.59 mm (Weasel) conforming to IS : 398-Pt.II-1976 including binding and jumpering. There should not be any joint between the span

2000

13

27740

... More
Supply & fixing of GI channel of size 75x40x40x6 mm bracket of following size clamped with above pole made by GI flat 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting .(2200 mm long )

18

856

15421.68

... More
Supply & erection of Galvanised stay set for HT OH line comprising of 20 mm dia with 87 1.8 mtr long stay rod, anchor plate of size 30x30cmx6mm/45x45x7.5mm, turn buckle ( 20mmx600 mm), 20mm thimble , stay clamp, 7/10 mm dia GI stay wire, Guy strain insulator of size 85 x 140 mm for 11KV as per ref. IS 5300/1969, and cc foundation with ratio 1:3:6 including excavation, refilling etc.

10

939

9396.8

... More
Supply and drawing of guard wire by 8 SWG GI wire and cross lacing by 10 SWG GI wire. Cross lacing shall be provided not more than 1 meter interval.

1500

8

12480

... More
Supply, fitting fixing and testing of 45 WATT LED BOGGIE LEVEL LIGHT with Luminaire efficacy of > 110 lm/W & 125lm/W and ip 68 rated, Surge protection : 4KV + 10KV SPD

200

3995

799026

... More
Supply, fitting fixing and testing of 45 WATT LED DOCK LEVEL LIGHT with Luminaire efficacy of > 110 lm/W & 125lm/W and ip 68 rated, Surge protection : 4KV + 10KV SPD

-

-

90

... More
Supply, fitting fixing and testing of 120 WATT LED PORTAL LIGHT, Surge protection : 4KV + 10KV SPD, with Luminaire efficacy of > 110 lm/W & 125lm/W and IP 68 rated & IK08 Luminaries

90

10045

904050

... More
Supply, fitting fixing and testing of LED 120 WATT BAY LIGHT, Surge protection : 4KV + 10KV SPD, with Luminaire efficacy of > 110 lm/W & 125lm/W and IP 68 rated & IK08 Luminaries

20

10045

200900

... More
Supply, fitting fixing and testing of 60 WATT LED CAT WALK LEVEL LIGHT Surge protection : 4KV + 10KV SPD, with Luminaire efficacy of > 110 lm/W & 125lm/W and IP 66 rated

150

4305

645750

... More
Supply, erection, testing andcommissioning of Precooling point with plug and socket point(including the foundation) for AC coaches in a modular/combinable insulated panel which should be shock proof,safe,IP65 according to IEC 60 259.(The panel shall hold type testcertificate in accordance with IEC60 439-1(IS 8623), IEC 60 439-3,the DB should have ASTAcertification by CPRI andmanufacturers routine testcertificate should be provided),weather proof, rust proof, UV resistant, halogen free, silica free,corrosion proof;protection class II,totallyinsulated, having internallyembedded gasket with provision forcable entry through glands and/orgrommets,flame retardant, selfextinguishing with glow wire test at960 degree C according to IEC 60695- 2-11; 94 chemical resistancetowards acid, lye, benzene andmineral oil; EMC compliant busbarsystem;Impact strength IK 08( 5joule) in accordance with DIN EN50 102. The plug & socket shall beIP 67 CEE type made of high qualitypolyamide P-6 body ( shock proof,rust free, corrosion free, acid andchemical resistant, fire retardant,having high impact, made ofhalogen and silica free recyclablematerial) & terminals contact solidhigh quality turned contacts madeof copper alloy brass. All steelcomponents ( screws,springs,etc)are zinc plated & blue chromed ornickel plated.For each contactdouble screws should be availableto give better cable strain relief.Theproducts shall hold type testcertificates as per IEC 60-309 &VDE specifications. Size -(390 x950 x 372) mm for complete set.Internal busbar for 3 phase &neutral shall be electrolytic gradecopper suitable for 150 Amps.MCCB shall be 125 amps 4 pole 36kA thermal magnetic release - Makeas per Schneider/Siemens/ABB - 1Nos. Plug & socket 125 amps 4 pole 35 kA, 5/8Pin ,IP 67 - 1 Nos.as per direction of engineer at site.

48

27910

1339705.92

... More
Supply & erection of BusBar Chamber with Copper Bars 200A, 4way, 415V for distribution PreCooling point.

6

4092

24557.16

... More
Supply & erection of industrial socket 32A, 4 pin (3ph+ E) splash proof conforming to IP : 44

20

557

11155.4



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.