Military Engineer Services Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date31 Aug 2024
Closing Date23 Sep 2024
Tender Amount₹ 23,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .

12

-

-

... More
Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete for poles, transformers base etc complete all as specified and as directed.

5

-

-

... More
Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.

4

-

-

... More
Materials and labour for providing cement concrete Type B1 1:2:4 ( 20 mm graded aggregate) as in coping of poles including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed.

2

-

-

... More
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3.0 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-I) laid laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed.

100

-

-

... More
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 95 Sqmm 3.5 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed.

100

-

-

... More
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 120 Sqmm 3.5 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed.

100

-

-

... More
Dismantling old unservicable steel tubular poles/struts, any size including breaking up PCC foundation and removal of rubbish complete all as specified and as directed.

18

-

-

... More
Supply and fixing steel tubular swaged pole, type 410 SP 44 (Overall length 10.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer including painting from bottom to 1.2m height alternative with 30cm red and white strip and writing pole no with black paint on yellow background complete all as specified and as directed. Note: (a) Earth work and PCC shall be measured and paid separately under relavent items of schedule 'A'/BoQ. (b) Design / drawing of HT pole and dimension is to be obtained from OEM/auth dealer/supplier and same is to be got approved from AGE(I) before placing order to the manufacturer.

10

-

-

... More
Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer including painting from bottom to 1.2m height alternative with 30cm red and white strip and writing pole no with black paint on yellow background complete all as specified and as directed. Note: (a) Earth work and PCC shall be measured and paid separately under relavent items of schedule 'A'/BoQ. (b) Design / drawing of HT pole and dimension is to be obtained from OEM/auth dealer/supplier and same is to be got approved from AGE(I) before placing order to the manufacturer.

8

-

-

... More
Material and labour for preparation of old painted surface of 11mtr long steel tubular electric HT pole by using emery paper, painting exposed surface with one coat of silver aluminium paint including painting from bottom to 1.2m height alternative with 30cm red and white strip and writing pole no with black paint on yellow background completed all as specified and as directed.

14

-

-

... More
Dismantling of insulator of any type any size from existing poles, after opening nuts,bolts and removing from site complete all as specified and as directed.

28

-

-

... More
Material and labour for insulator, 33 KV porcelain solid core with dry and wet withstand voltage 70KV (Rms), 50HZ suitable for outdoor electrically exposed installation , mounting face installation with face diameter 113mm approx, height 508mm,minimum creepage distance of porcelain 1065mm conforming to IS 2544, IS-5350 and IEC 60273 and complete all as specified and as directed.

4

-

-

... More
Material and labour for Disc insulator 33 KV,porcelain solid core with dry arc distance 380mm, dia of weather shed 110mm,length of FRP rod 425mm, dia of FRP road 16mm creepage distance 900mm complete all as specified and as directed.

12

-

-

... More
Material and labour for Pin tpye insulator, 33 KV, overall hight 240mm, and dia 240mm, with top 125 mm and neck 100 mm dia ,creepage distance 720 mm, conforming to IS-731/1971, complete all as specified and as directed.

12

-

-

... More
Dismantling of existing unserviceable/undersize ACSR conductor (of any size) , jumper from overhead line and removing from site complete all as specified and as directed.

450

-

-

... More
Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed.

350

-

-

... More
Fixing only Aluminum conductor steel reinforced (ACSR) conductor (obtained from dismantling vide serial Item No. 19) as in overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed.

100

-

-

... More
Dismantling of old rusted Cross Arms bracing support, clamps and back plate of any sections from poles setting aside complete all as specified and as directed.

150

-

-

... More
Material and labour for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed.

150

-

-

... More
Material and labour as in replacement for HT lightening arrestor with mountings accessories complete fixed on cross arms of two pole structure/GI flat strip and connect with same size of ACSR conductor with all fittings connected to earth strip with nut, bolt, washer transmission class having discharge capacity of 65 kilo Amps and suitable for 33000 Volts expulsion type complete all as specified and directed.

4

-

-

... More
Supply and fixing as in replacement for Danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole complete all as specified and as directed.

6

-

-

... More
Material and labour for complete servicing of HT 33 KV VCB 800 Amps alongwith CTS/PTS of any make and type by drawing out breaker assembly from panel and carry out the following maintenence/repair work :- (i) Cleaning/decarbonizing of all fixed and moving contacts, levers, charging springs by using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, (ii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, necessary brazing, turnig, polishing of main and auxiliary contact etc. (iii) Testing of HT VCB by using primary & secondary high current injection method, test including measuring of CT ratio and polarity all as directed. (iv) Resetting of tripping relay and interlocking system. (v) Checking of operating mechanism and its adjustments, measurements of the mechanical clearances of operating mechanism. (vi) Checking of internal wiring circuit, tightening of all electrical connections, replacement of HRC fuse, fuse carrier base (if any found u/s) including removing moisture content complete all as directed.

1

-

-

... More
(vii) Checking of all indicators as per required operation and end terminals, including replacement of damaged/rusted nut, bolt & washers etc and put the breaker in position to engage the VCB with the supply system and testing for smooth functioning. NOTE : (i) The cost of minor items like nut, bolt with double washers, HRC fuse up to the capacity of 32 Amp, fuse carrier base replacement of complete HT packing/gasket shall deemed to be included in the quoted rate. (ii) The major spare parts if required for repair to VCB shall be measured and paid separately (iii) The repair work shall be carried out by authorised representative of OEM. Necessary test report shall be submitted by the contractor to the Department.

-

-

-

... More
Material and labour for complete servicing of HT 33 KV VCB 630 Amps alongwith CTs/PTs of any make and type by drawing out breaker assembly from panel and carry out the following maintenence/repair work :- (i) Cleaning/decarbonizing of all fixed and moving contacts, levers, charging springs by using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, (ii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, necessary brazing, turnig, polishing of main and auxiliary contact etc. (iii) Testing of HT VCB by using primary & secondary high current injection method, test including measuring of CT ratio and polarity all as directed. (iv) Resetting of tripping relay and interlocking system. (v) Checking of operating mechanism and its adjustments, measurements of the mechanical clearances of operating mechanism. (vi) Checking of internal wiring circuit, tightening of all electrical connections, replacement of HRC fuse, fuse carrier base (if any found u/s) including removing moisture content complete all as directed.

3

-

-

... More
(vii) Checking of all indicators as per required operation and end terminals, including replacement of damaged/rusted nut, bolt & washers etc and put the breaker in position to engage the VCB with the supply system and testing for smooth functioning. NOTE : (i) The cost of minor items like nut, bolt with double washers, HRC fuse up to the capacity of 32 Amp, fuse carrier base replacement of complete HT packing/gasket shall deemed to be included in the quoted rate. (ii) The major spare parts if required for repair to VCB shall be measured and paid separately (iii) The repair work shall be carried out by authorised representative of OEM. Necessary test report shall be submitted by the contractor to the Department.

-

-

-

... More
Supply and fix in repair of Spring charging electric motor single phase 220 -250 Volts 50-60 Hz AC -DC of capacity 200Watt (0.27HP) 140 RPM , suitable for 33KV VCB outdoor type of capacity 2000 Amp and connecting with existing electric system complete commissioning and testing all as directed.

3

-

-

... More
Material and labour as in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.

2

-

-

... More
Material and labour as in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and as directed.

3

-

-

... More
Filtaration/dehyderation of trnasformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil upto 60 KV complete all as specified and directed for various capacity of transformers /OCB's/Servo Voltage stabilizer installed at various locations at chakabama . Note: (a) The contractor shall obtain shut down orders in writing before commencement of the work (b) The contractor shall avoid wastage of existing transformer oil. (c) The contractor shall be solely responsible for any damages to the transformer during process of oil filtration. He shall be responsible for making good any damage to the transformer at his own cost without any extra cost tothe department. (d) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehyderation process. (e) Additional qty of transformer oil if any required for making the oil level upto the requirement in each transformer shall be measured and paid separately as supply and filling but its cost of heating and dehyderation shall be deemed to be included in the quoted rate.

800

-

-

... More
Supply and filling transformer oil for topping up insulating oil EHV grade having dielectric strength not less than 60 KV high viscosity in transformer conforming to IS-335 to 1983 all as specified and directed for various capacity of transformers/OCB's/Servo Voltage Stabiliser installed at various locations at chakabama .

700

-

-

... More
Supply and fixing transformer breather assembly oil seal type made of transparant PVC body heavy duty filled with good quality silica gel blue colour of capacity 800 grams complete all as specified and as directed.

3

-

-

... More
Supply and fixing transformer breather assembly oil seal type made of transparant PVC body heavy duty filled with good quality silica gel blue colour of capacity 1200 grams complete all as specified and as directed.

2

-

-

... More
Material and labour as in replacement for HV bushing with gasket and arcing horn suitable for 11KV/433V distribution transformers of 100 to 150KVA capacity complete all as specified and as directed.

12

-

-

... More
Material and labour as in replacement for LV bushing with gasket and arcing horn suitable for 11KV/433V distribution transformers of 100 to 150KVA capacity complete all as specified and as directed.

12

-

-

... More
Material and labour as in replacement for HV brass stud full threaded with required nuts and washer suitable for 11KV/433V distribution transformer of 100 to 150KVA capacity complete all as specified and as directed.

12

-

-

... More
Material and labour as in replacement for LV brass stud full threaded with required nuts & washer suitable for 11KV/433V distribution transformer of 100 to 150 KVA capacity complete all as specified and as directed.

12

-

-

... More
Material and labour for replacement of VCB 110 volts Hooter all as specified and directed complete all as specified and as directed.

4

-

-

... More
Material and labour for replacement of Buchholz relay of transformer capacity 1200 KVA complete all as specified and as directed.

1

-

-

... More
Material and labour for replacement of indicating LED lamp RYB with lamp holder 220 volts complete all as specified and as directed.

18

-

-

... More
Supply and fixing gang operated air brake switch mechanically operated on insulator and steel frame, with operating mechanism worked from ground level, with 9 Nos insulator tilting type for current rating 400 Amps,11000Volt, including taking down old unserviceable one complete all as specified and directed.

3

-

-

... More
Material and labour for coarse agreegates, grading 25 to 40mm size at main receiving 33 KV station, including spreading equally 150mm thick complete all as specified and as directed.

25

-

-

... More
Materials and labour for earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of 20 x 3mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. (Note: Earth strip upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)

8

-

-

... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.