Military Engineer Services Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date22 Mar 2021
Closing Date19 Apr 2021
Tender Amount₹ 15,63,252 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DG set 250 KVA installed at near ATC for FIS building

-

-

-

... More
DG set 250 KVA installed at CR & SS Hanger

-

-

-

... More
DG set 160 KVA installed at Stn Logistic section

-

-

-

... More
DG set 125 KVA installed at ATC

-

-

-

... More
DG set 125 KVA installed at SRE

-

-

-

... More
DG set 100 KVA installed at 8ASC

-

-

-

... More
DG set 100 KVA installed at 35 MCU

-

-

-

... More
DG set 100 KVA installed at Gyan Jothi Building

-

-

-

... More
DG set 100 KVA installed at MES Main pump House

-

-

-

... More
DG set 100 KVA installed at FMS building

-

-

-

... More
DG set 100 KVA installed at Telephone Exchange

-

-

-

... More
DG set 100 KVA installed at 'C' Tank pump House

-

-

-

... More
DG set 100 KVA installed at old Booster pump house at Madambakkam

-

-

-

... More
DG set 100 KVA installed at Moolgaonkar Block

-

-

-

... More
DG set 100 KVA trolly mounted for Main camp sewage pump house

-

-

-

... More
DG set 82.5 KVA installed at BCR

-

-

-

... More
DG set 62.5 KVA installed at shiva temple well

-

-

-

... More
DG set 62.5 KVA installed at Mehra Hall

-

-

-

... More
DG set 62.5 KVA installed at Telephone Exchange

-

-

-

... More
DG set 62.5 KVA installed at Transmitter

-

-

-

... More
DG set 50 KVA installed at Narendra Place Pump House

-

-

-

... More
DG set 45 KVA installed at One lakh Pump House

-

-

-

... More
DG set 20 KVA installed at CDAF Hut

-

-

-

... More
DG set 20 KVA installed at 143 sewage pump House

-

-

-

... More
DG set 20 KVA installed at 28 officers sewage pump house

-

-

-

... More
DG set 20 KVA installed at station Armoury

-

-

-

... More
DG set 20 KVA installed at 9 P&S Pallavaram

-

-

-

... More
DG set 20 KVA installed at Golden jubilee pump House

-

-

-

... More
DG set 20 KVA installed at M & CWC Madambakkam

-

-

-

... More
DG set 15 KVA installed at vishnu temple well

-

-

-

... More
DG set 7.5 KVA installed at Kiran DSS hangar (Front)

-

-

-

... More
DG set 7.5 KVA installed at Kiran DSS hangar (Rear)

-

-

-

... More
DG set 7.5 KVA installed at Kiran R& SS hangar (Front)

-

-

-

... More
DG set 7.5 KVA installed at Kiran R& SS hangar (Rear)

-

-

-

... More
DG set 7.5 KVA installed at LOGISTIC section.

-

-

-

... More
DG set 16 KVA installed at Roopvani

-

-

-

... More
M&L for inspection, maintenance and servicing of DG sets including Alternator, Non AMF/ AMF panels of connected DG sets for routine check up (B-check once in six month or 250 hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete services as per the manufacturers instructions including items covered in 'A'-Check (Ref item No.1) all as specified for following DG sets:- Note for item No.2:- Engine oil shall be issued by department free for filling & Coolant shall be measured paid seperetaly under relevant item.

-

-

-

... More
DG set 250 KVA installed at FMS building

2

-

28

... More
DG set 250 KVA installed at near ATC for FIS building

2

-

29

... More
DG set 250 KVA installed at CR & SS Hanger

2

-

30

... More
DG set 160 KVA installed at Stn Logistic section

2

-

31

... More
DG set 125 KVA installed at ATC

2

-

32

... More
DG set 125 KVA installed at SRE

2

-

33

... More
DG set 100 KVA installed at 8ASC

2

-

34

... More
DG set 100 KVA installed at 35 MCU

2

-

35

... More
DG set 100 KVA installed at Gyan Jyothi bldg

2

-

36

... More
DG set 100 KVA installed at MES Main pump House

2

-

37

... More
DG set 100 KVA installed at FMS building

2

-

38

... More
DG set 100 KVA installed at Telephone Exchange

2

-

39

... More
DG set 100 KVA installed at C Tank pump House

2

-

40

... More
DG set 100 KVA installed at old Booster pump house at Madambakkam

2

-

41

... More
DG set 100 KVA installed at Moolgaonkar Block

2

-

42

... More
DG set 100 KVA trolly mounted for Main camp sewage pump house

2

-

43

... More
DG set 82.5 KVA installed at BCR

2

-

44

... More
DG set 62.5 KVA installed at Shiva temple well

2

-

45

... More
DG set 62.5 KVA installed at Mehra Hall

2

-

46

... More
DG set 62.5 KVA installed at Telephone Exchange

2

-

47

... More
DG set 62.5 KVA installed at Transmitter

2

-

48

... More
DG set 50 KVA installed at Narendra Place Pump House

2

-

49

... More
DG set 45 KVA installed at One lakh Pump House

2

-

50

... More
DG set 20 KVA installed at CDAF Hut

2

-

51

... More
DG set 20 KVA installed at 143 sewage pump House

2

-

52

... More
DG set 20 KVA installed at 28 officers sewage pump house

2

-

53

... More
DG set 20 KVA installed at station Armoury

2

-

54

... More
DG set 20 KVA installed at 9 P&S Pallavaram

2

-

55

... More
DG set 20 KVA installed at Golden jubilee pump House

2

-

56

... More
DG set 20 KVA installed at M & CWC Madambakkam

2

-

57

... More
DG set 15 KVA installed at Vishnu temple well

2

-

58

... More
DG set 7.5 KVA installed at Kiran DSS hanger(Front)

2

-

59

... More
DG set 7.5 KVA installed at Kiran DSS hanger(Rear)

2

-

60

... More
DG set 7.5 KVA installed at Kiran R & SS hanger(Front)

2

-

61

... More
DG set 7.5 KVA installed at Kiran R & SS hanger (Rear)

2

-

62

... More
DG set 7.5 KVA installed at LOGISTIC section.

2

-

63

... More
DG set 16 KVA installed at Roopvani

2

-

64

... More
M&L for replacement of fan belt of any size for DG set of capacity upto 250 KVA all as specified and as directed.

6

-

47

... More
M&L for replacement of diesel hose of size 5/16mm dia all as specified and as directed.

10

-

47

... More
M&L for replacement of radiator set hose of any sizes with clips (full set) all as specified and as directed.

3

-

47

... More
M&L for replacement of voltmeter 0-500V of size 96mm with all connection (Analogue type) all as specified and as directed.

2

-

47

... More
M&L for replacement of ammeter 0-100 Amps of size 96mm with all connection (Analogue type) all as specified and as directed.

2

-

47

... More
Supply only Engine oil 15 W 40 type make Servo or equivalent

1050

-

47

... More
Note for Sl item No 8 : (a) The payment shall only be allowed after production of original GST purchase vouchers from Authorised dealers.(b) Necessary RV for supply of engine oil shall be attached in final bill duly signed by Engineer-in-Charge.

-

-

-

... More
Disconnecting, removing and dismantling water radiator assembly of 7.5/ 20/ 45/ 50/ 60/ 62.5 KVA DG Set and descaling the radiator thoroughly completely with CTC solution/ any other chemical solvent agent as approved, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., reinstalling and commissioning etc., complete all as specified and as directed by Engineer-in-charge.

1

-

47

... More
All as per item No.09 above but for DG set of capacity above 100 KVA and upto 250 KVA

1

-

47

... More
Disconnecting the existing battery of capacity 12 volts upto 180 AH from the DG Set, taking it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG Set, start the engine for satisfactory function etc., complete all as specified and as directed by Engineer-in-Charge.

4

-

47

... More
M&L for removing/ replacing radiator cap all as specified

2

-

47

... More
M&L for replacing start switch/ ignition switch suitable for DG Set of capacity ranging from 20 KVA to 250 KVA

2

-

47

... More
M&L for replacing phase indication lamp for panel all as specified

3

-

47

... More
M&L for oil pressure gauge range 0-10 kg/sqcm all as specified

2

-

47

... More
M&L for DC ammeter/ voltmeter of any range all as specified

2

-

48

... More
Repairs to 12 volts battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stater assembly, assembly refixing to the engine and testing for satisfactory charging of battery etc., complete all as specified and as directed.

1

-

48

... More
All as per item No.17 above but of 24 volts battery charging alternator

1

-

48

... More
Repairs to 12/ 24 volts self starter by removing, dismantling and replacing unserviceable Armature and field coil including field coil tapping refixing to the engine including necessary testing for satisfactory function etc., complete all as specified and as directed.

3

-

48

... More
M&L for supplying and fixing the CI coupling along with tyre or without tyre suitable for DG set capacity upto 62.5 KVA including necessary matching work milling work for cutting key way in the flange heating to fix with the existing flange, including replacement of bolts, nuts, washers etc., carry out alignment, testing for satisfactory performance including removing old unserviceable coupling etc., complete all as specified and as directed.

1

-

48

... More
All as per item No.20 above but of 250 KVA capacity

1

-

48

... More
M&L for replacement the worn out carbon brushes slip ring type in alternator of capacity 7.5 KVA to 20 KVA DG set Kirloskar make including all necessary connected works etc., complete all as specified and as directed.

3

-

48

... More
M&L for replacement the worn out carbon brushes slip ring type in alternator of capacity 45 KVA to 250 KVA DG set Kirioskar make including all necessary connected works etc., complete all as specified and as directed.

2

-

48

... More
M&L for replacing the old unserviceable battery lead with copper terminals approximately 1 metre length including applying jelly over the battery pole and terminals etc., complete all as specified and as directed.

10

-

48

... More
M&L for replacement the old unserviceable battery terminals including brazing work and applying jelly over the battery pole and terminals etc., complete all as specified and as directed.

2

-

48

... More
M&L for Scraping down the existing oily painted surface of the DG set of capacity up to 250KVA, making the surface smooth by filling up the uneven surfaces with putty and scraping with emery sheet, applying two coats of synthetic enamel paint over one coat of red oxide primer, painting Sl No & MES No over the DG set and alternator all as specified and directed by Engineer-in-Charge.

1

-

48

... More
M&L for Draining out the existing diesel from the tank, kept as side for repouring, taking down the complete fuel tank of any capacity from its position after disconnecting all the fuel lines, carryout cleaning work with solutions, removing the dust and foreign materials from the tank, drying the tank, blow with air painting and carry out recalibration of diesel tank to the specified level including replacement of PVC level pipe, refix the tank in its original position, connecting all the removed fuel connections, refilling the kept diesel back to the tank carefully, remove air from the fuel connections, start the engine and testing for satisfactory function all as specified and directed.

2

-

48

... More
Removing and replacing the old unserviceable AVR (Automatic voltage regulator) suitable for DG set up to 250 KVA having input voltage 2 phase + neutral, sensing voltage 415 V output voltage 95 volts DC, output current 4 A DC, voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4 A, fast acting and frequency 50 Hz etc., complete all as specified and as directed by Engineer-in-Charge.

2

-

48

... More
M&L for replacing unserviceable combined digital meter for showing voltmeter, ammeter, frequency including necessary wiring and wiring material for connecting the meter etc., complete all as specified and as directed.

2

-

48

... More
M&L for removing and replacing the old unserviceable 12 volts auto cut-off battery charger in control panel as per existing type/ model including necessary wiring etc., complete all as specified and as directed.

4

-

48

... More
Supply and fix lead acid battery of size 12 volts 100 AH of reputed make including initial charging all as specified and as directed.

8

-

49

... More
Supply and fix lead acid battery of size 12 volts 130 AH of reputed make including initial charging all as specified and as directed.

2

-

50

... More
Supply and fix lead acid battery of size 12 volts 180 AH of reputed make including initial charging all as specified and as directed.

4

-

51

... More
Note for Sl item No 31 to 33 : (a) The payment shall only be allowed after production of original GST purchase vouchers from Authorised dealers.

-

-

-

... More
Taking down FIP and disconnecting injectors from fuel lines upto 250 KVA, replacement and worn out spares like delivery valve, Nozzles, bearings, fly weight, packing kit, O ring kit and copper washer Kit and recalibration of FIP and Refixing in same position and testing of full Load checking of pressure all as specified and directed

1

-

48

... More
M&L for disconnecting the radiator from 7.5 KVA to 50 KVA DG Set and replacing unserviceable copper core ,testing and commissioning complete all as specified and directed.

1

-

48

... More
M&L for disconnecting the radiator from 62.5 to 110 KVA DG Set and replacing unserviceable copper core ,testing and commissioning complete all as specified and directed.

1

-

48

... More
M&L for disconnecting electrical and mechanical connections of alternator 415 volts, 50 HZ, 7.5 KVA to 62.5 KVA capacity removing from foundations/ diesel engine coupling and dismantling the alternator in parts and carrying out servicing/ overhauling to starter/ Rotor/ excitation windings by replacing the new insulations paper sheet of existing size/ shape replacing the glass sleeves of connecting leads, binding/ tightening loose coils with binding cloths, varnishing and applying the bactol on the exciter coils/ winding with super varnish, heating the windings at appropriate temperature to achieve required insulation resistance without damaging the other parts, replacement of driving and non driving end bearings, cleaning, greasing, reassembling/ installing/ connecting and testing with megger for insulation resistance etc., complete all as specified and directed by Engineer-in-Charge.

1

-

48

... More
M&L for disconnecting electrical and mechanical connections of alternator 415 volts, 50 HZ, 82.5 KVA to 250 KVA capacity removing from foundations/ diesel engine coupling and dismantling the alternator in parts and carrying out servicing/ overhauling to starter/ Rotor/ excitation windings by replacing the new insulations paper sheet of existing size/ shape replacing the glass sleeves of connecting leads, binding/ tightening loose coils with binding cloths, varnishing and applying the bactol on the exciter coils/ winding with super varnish, heating the windings at appropriate temperature to achieve required insulation resistance without damaging the other parts, replacement of driving and non driving end bearings, cleaning, greasing, reassembling/ installing/ connecting and testing with megger for insulation resistance etc., complete all as specified and directed by Engineer-in-Charge.

1

-

48

... More
M&L for disconnecting electrical and mechanical connections of alternator 415 volts 50 HZ, 7.5 KVA to 62.5 KVA capacity removing from foundations/diesel engine coupling and dismantling the alternator in parts and carrying out re winding of alternator without damaging the other parts, replacement of driving and non driving end bearings, cleaning, greasing, reassembling/installing/connecting and testing with megger for insulation resistance etc., complete all as specified and directed by Engineer-in-Charge.

1

-

49

... More
M&L for disconnecting electrical and mechanical connections of alternator 415 volts 50 HZ, 82.5 KVA upto 250 KVA capacity removing from foundations/diesel engine coupling and dismantling the alternator in parts and carrying out re winding of alternator without damaging the other parts, replacement of driving and non driving end bearings, cleaning, greasing, reassembling/installing/connecting and testing with megger for insulation resistance etc., complete all as specified and directed by Engineer-in-Charge.

1

-

48

... More
M&L for replacing water pump half assembly for DG set of any capacity of DG set complete all as specified

2

-

48

... More
Supply only coolant for DG Set radiator (mixing ratio of 1:9)

60

-

48

... More
Note for Sl item No 42 : (a) The payment shall only be allowed after production of original GST purchase vouchers from Authorised dealers.(b) Necessary RV for supply of coolant shall be attached in final bill duly signed by Engineer-in-Charge.

-

-

-

... More
Dismantling of unserviceable AMFR logic controller of Control panel and replacing with new AMFR logic controller including replacement of existing unserviceable wiring with 1.5 sqmm PVC multistranded copper conductor single core 1100 V cable of voltmeter,indicator lamp,frequency meter etc complete all as directed.

2

-

48

... More
M&L for replacement of manual contactor ON/OFF-switch 16A-2P-2Way Make: C&S SAZER

2

-

48

... More
M&L for replacement of 4pole power contactor for DG set capacity 250 KVA in control panel all as specified and directed.Make:L&T MCX 42

2

-

48

... More
M&L for replacement 4pole power contactor for DG set capacity 100/110 KVA in control panel all as specified and directed.Make:L&T MCX 32

2

-

48

... More
M&L for replacement of 4 pole power contactor for DG set capacity 62.5 KVA in control panel all as specified and directed.Make:L&T MCX 22

2

-

49

... More
M&L for replacement of spare coil for 4 pole power contactor, 240/415 volts suitable for MCX 42. Make : L & T

2

-

50

... More
M&L for replacement of spare coil for 4 pole power contactor, 240/415 volts suitable for MCX 32. Make : L & T

5

-

51

... More
M&L for replacement of spare coil for 4 pole power contactor, 240/415 volts suitable for MCX 22. Make : L & T

3

-

52

... More
Supply and fix 'Onload' change over switch with sheet metal enclosure, 4 pole, 415 Volts, 400 Amps capacity

1

-

53

... More
Supply and fix 'Onload' change over switch 4 pole, 415 Volts, 200 Amps capacity

1

-

54

... More
Supply and fix 'Onload' Change over switch 4 pole, 415 Volts, 100 Amps capacity

4

-

55

... More
Material and labour for earthing complete with GI plate electrode 600mmx600mmx6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 32mm x 6 mm GI strip by means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1cover slab 50mm thick with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion all as specified and directed

4

-

48

... More
Comprehensive maintenance of 680 Kg capacity passenger lift of Make : Johnson Serving for ground plus five floors examining, adjusting, lubricating and repairs as required complete all as directed by Engineer-in-Charge. Machine No of lift : L-C7190 Location : SRE ATC Building at Airforce station Tambaram. Comprehensive maintenance shall include the following works mentioned below:- Note 1 : Quoted rate shall be deemed to be included for minor spares (for satisfactory functioning of lift). Other spare sparts listed in this schedule shall be measured and paid separately under relevant item . Note 2 : Annual maintenance contract of the lift shall be carried out through the manufacture i.e. Johnson only and maintenance to be carried out as per Johnson manufacture schedule . Note 3 : The rate deemed to inclusive of insurance reneval of lift and reneval of lift inspection from Tamilnadu government Lift Inspector.

11

-

48

... More
Systematically examine and adjust the following components :-

-

-

-

... More
Machine , Worm Gear, Thrust Bearings, Drive Sheave, Drive Sheave Bearings, Brake contact, Lining and Components.

-

-

-

... More
Motor, Motor Generator, Motor Windings, Rotating Elements, Commutator, Brushes, Brush Holders, Bearings, Coils, Resistance for Operating and Motor Circuits, Magnet Frames and other Mechanical Parts.

-

-

-

... More
Controller, Selector, Levelling Devices, Cams, Relays, Solid State Components e.g. PCBs, Transducers, Resistors, Condensors, Power Amplifiers, Transformers, Contacts, Leads, Dashpots, Timing Devices, Steel Selector Tapes and Mechanical and Electrical Driving Equipment.

-

-

-

... More
Governor, Governor Sheave, Shaft Assembly, Bearings, Contacts and Governor Jaws.

-

-

-

... More
Car and Hall Mechanical Buttons, Car and Hall Position Indicators, Hall Lanterns, Car Direction Indicators and all other Car and Landing Signal Fixtures.

-

-

-

... More
Deflector or Secondary Sheave, Bearings, Car and Counterweight Guide Rails and Buffers, Top and Bottom Limit Switches, Governor Tension Sheave Assembly, Compensating Sheave Assembly, Car, Counterweight and Counterweight Guide Shoes including Roller or Gibs.

-

-

-

... More
Interlocks on Hoistway Door, Hoistway Door Hangers, Guides, Automatic Power Operated Door Operator, Car Door Hanger, Car Door Contact, Safety Shoe, Load Weighing Equipment, Car Frame, Car Safety Mechanism and Platform.

-

-

-

... More
Furnish lubricants compounded to manufacturers stringent specifications.

-

-

-

... More
Examine periodically all safety devices and governors and make all customary safety tests.

-

-

-

... More
Supply only the following spres/ items for Lift

-

-

-

... More
Cross flow fan

1

-

48

... More
Charger Unit

1

-

48

... More
ARD Battery ( 12 V - 18 AH )

2

-

48

... More
LED Round light fitting suitable for lift

5

-

48

... More
Note for Sl item No 56.01 to 56.04 : (a) The payment shall only be allowed after production of original GST purchase vouchers from Authorised dealers.(b) Necessary RV for supply of spare shall be attached in final bill duly signed by Engineer-in-Charge.

-

-

48



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.