Urban Development Department ADB Tender Tender

View complete overview of Sikkim Urban Development Department ADB Tender Tender

Urban Development Department ADB Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date6 Mar 2025
Closing Date10 Apr 2025
Tender AmountRefer Documents 
Notes
Download

AI Insights

Work Experience Requirements
... View More
The required prior work experience for the bidder includes participation in at least one contract that has been satisfactorily and substantially completed within the last 7 years and that is similar to the proposed contract. The similarity of the Bidder’s participation shall be based on specific criteria, including design and construction or construction of sewage treatment plants, water treatment plants, gravity sewers, or water supply networks. The value of the Bidder’s participation must exceed INR 376.00 million (INR 37.60 Cr). Additionally, the bidder must have construction experience in key activities, including design, providing, laying, jointing, testing, and commissioning of at least one Water Supply system and one Sewerage Network, both with minimum lengths and having PLC based centralized SCADA systems. A contract is considered substantially complete if it is 80% physically complete, and the value of the completed part of the contract (80%) shall be equal to or exceed the minimum value defined in the criteria, which is INR 376.00 million (INR 37.60 Cr). However, detailed monetary values for similar works completed are not mentioned for each type of work, except for the minimum value of the bidder's participation.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing detailed geological reports of proposed site by maintaining geotechnical investigation of structure stratification collecting soil, rock and ground water samples for laboratory tests to arrive the foundation design parameters. Rock properties such as type of rock, jointing fractures, etc. complete with suggestion about the site foundation and remedies.

20

-

-

... More
Taking the trial pit for water and sewer pipelines, C.D. Works in Hard murum, and Boulders including stacking the excavated material including all lifts and necessary back filling upto depth 3.0 meters

40

-

-

... More
Preparation and submission of hydraulic design, Civil/structural design, Electrical, mechanical, and instrumentation design and drawings as per technical specifications and instructions from the Employer's Representative.

1

-

-

... More
Creation of as-built drawings for Civil/structural, Electrical, mechanical, and instrumentation work as per technical specifications and instructions from the Employer's Representative.

1

-

-

... More
Vetting of major RCC structures for STP/WTP and their ancillary works by a reputable government institution (such as IIT/NIT or as approved by the Employer's Representative), as per technical specifications and instructions from the Employer's Representative.

1

-

-

... More
Development of training programs and manuals. All activities will be carried out in accordance with the scope of work and as directed by the Employer's Representative.

1

-

-

... More
Schedule-2 Civil Works

-

-

-

... More
Approach Road to WTP Work

-

-

-

... More
Stripping, storing and preservation of top soil by keeping it damp in stock piles and keep wet till it is used by road side at 15 m internal and re-application on embankment slopes, cut slopes and other areas in localities where the available embankment material is not conducive to plant growth as per Technical Specification Clause 302.3.2

2250

-

-

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

6000

-

-

... More
By Mix in Place Method (Construction of granular subbase by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401)

1125

-

-

... More
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.)

1125

-

-

... More
Tack coat (Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at required rate on the prepared bituminous/granular surface cleaned with mechanical broom.) Normal Bituminous Surface

7500

-

-

... More
(Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction)

375

-

-

... More
Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate shown in 500-1 using mechanical means.)

7500

-

-

... More
Semi - Dense Bituminous Concrete (Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects) Using Bitumen 60/70 grade;for Grading I ( 13 mm nominal size )

187.5

-

-

... More
River Crossing Bridge for Pipe Line

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. Upto 1.5 Mtr Depth, For Column Foundation

507.2

-

-

... More
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

202.88

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level.Cement concrete grade M-10 (Nominal Mix) with 20 mm maximum size of stone aggregate For Column Foundation

33.81

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 410 kg. of cement per cum of concrete. All work up to floor 2 level.

312.45

-

-

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire upto floor two level including all wastage etc. complete.@ 1.5% of concrete volume

44149.19

-

-

... More
Centering and shuttering including strutting, propping etc.and removal of form for : For Sides of Foundation

210.6

-

-

... More
For Column

702

-

-

... More
For Column Beam

140.4

-

-

... More
For Column Beam (Tripozidal Section)

131.63

-

-

945

-

-

... More
Construction of dowel jointed, plain cement concrete pavement in M-40 grade concrete over a prepared sub base with 43 or higher grade cement, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar and tie rod, admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC-15 2002 and as per relevant clauses of section-602 of of MORTH specifications complete but excluding cost of steel in dowel bar & tie rod etc..

105

-

-

... More
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification

700

-

-

... More
Intake Headwork

-

-

-

... More
Gabian Structure for Retaining Earth (Providing and construction of a gabain structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments by cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding 100 x 100 mm, filled with boulders with least dimension of 200 mm, all loose ends to be tied with 4 mm galvanised steel wire.

150

-

-

... More
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

336.14

-

-

... More
Providing and Laying Plum concrete in 1:2:4 c.c. (1cement, 2coarse sand, 4clean hard graded stone chips of 20 mm down nominal gauge) with 70% clean hard stone of sizes not exceeding 15cm including shuttering, compacting and curing complete, as per the direction of Engineer in Charge.

242.44

-

-

... More
Providing and laying hand packed stone soling in buildings works with clean hard selected stones, all complete. (Manual)

15.31

-

-

... More
Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete. 1:2:4 mix. (1 cement, 2 coarse sand, 4 graded stone aggregate of 20mm & down size)

15.31

-

-

... More
Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of form work, finishing and reinforcements. 1:1.5:3 Mix (1cement, 1.5 coarse sand 3 graded stone aggregate 20mm and down nominal gauge)

45.5

-

-

... More
Providing, fixing & removing form work for casting R.C.C items as indicated below: with imported timber from outside the state) Beam, lintels, girders, brersumers and cantilevers.

94.08

-

-

... More
Supplying, bending and placing in position tor steel reinforcement in all R.C.C works including cost of binding wires, all complete.

5915

-

-

... More
Providing and Laying 12mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete. 1:3 Mix

52.2

-

-

... More
Providing, fitting and fixing steel windows and ventilators of standard rolled steel section joints mitered and welded with iron lugs embedded in cement concreten 1:3:6 including providing fitting and fixing 3 mm thick glass pens with glazing clips and special metal putty complete with MS grills @ 150mm c/c as per the direction of Engineer - in- Charge all complete: (Trash Rack with 75 X 75X 6 mm Angle).

1578.72

-

-

... More
Gabian Structure for Retaining Earth (Providing and construction of a gabain structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments by cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding 100 x 100 mm, filled with boulders with least dimension of 200 mm, all loose ends to be tied with 4 mm galvanised steel wire.

29.71

-

-

... More
Pipe Assembly (DI k9); 200 mm Dia For Outlet Pipe

12

-

-

... More
For Washout Pipe

12

-

-

... More
Installation of Washout and main valves; 200 mm Dia For Outlet

1

-

-

... More
For Washout

1

-

-

... More
RCC Channel

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil with all lead and lift as per the direction of Engineer in Charge.

255.6

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) Bottom

20.4

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 410 kg. of cement per cum of concrete. All work up to floor 2 level. Bottom and Walls

63.6

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

5724

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns

36

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc

480

-

-

... More
Sedimentation tank at Intake

-

-

-

... More
Earth work in hard murum and boulders, excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

296.89

-

-

... More
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

32

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size).

6.83

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 410 kg. of cement per cum of concrete. All work up to floor 2 level.

57.06

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above.

5706

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work.

8.5

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc For wall

248

-

-

... More
For Suspended floors, roofs, landings, balconies and access platform

60

-

-

... More
Foot Rest

13

-

-

... More
Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer-in-charge (20 tonnes capacity). 90 x 60 cm size

6

-

-

... More
Pipe Line Work

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

16685.49

-

-

... More
Sand Filling in Foundation Trenches as per Drawing & Technical Specification

606.96

-

-

... More
Supply & Laying - Jointing of following dia. D.I. K-7 S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment, making the joints with approved EPDM quailty of rubber gaskets including cost of all jointing materials and testing etc. complete but excluding excavation and backfilling of trenches upto ground level.D.I. Pipe S&S K-7 (CONFORMING TO IS : 8329/2000).with internal cement mortar lining using sulphate resisting cement (SRC) 200 mm dia DI K7

20232

-

-

... More
10% of cost of pipes shall be considered for cost of specials for estimate purpose only

1

-

-

... More
Supplying and fixing of following sizes of valves including carting the same upto site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect but excluding the cost of earth work and construction of chamber. C.S. D/F Sluice Valves (200 mm)

10

-

-

... More
C.S. Air Valve Double Acting.80mm dia

10

-

-

... More
C.S. D/F Non Return Valves.( 200 mm dia)

4

-

-

... More
Scour Valve (200mm)

10

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

37

-

-

... More
Construction of brick masonry Sluice valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid

14

-

-

... More
Construction of brick masonry Air valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.

10

-

-

... More
Construction of brick masonry Scour valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.

10

-

-

... More
Construction of RCC Bulk Flow meter chamber including earthwork excavation, 100mm PCC M15 (1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) as leveling course, RCC M25 grade for base slab, side wall & cover slab including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer.

3

-

-

... More
Providing, installation, testing and commissioning of Bulk Flow Meter with removable mechanism class "B" confirming to ISO: 4064/1 including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipe line etc complete in all respect as per technical specification and as per direction of Engineer. 150 mm dia pipe DI K7

2194

-

-

... More
200 mm dia pipe DI K7

422

-

-

... More
10% of cost of pipes shall be considered for cost of specials for estimate purpose only

1

-

-

... More
Supplying and fixing of following sizes of valves including carting the same upto site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect but excluding the cost of earth work and construction of chamber. C.I. D/F Sluice Valves Confirming to IS: 14846-2000 ( Kirloskar or equivalent) 150 mm

2

-

-

... More
200 mm

2

-

-

... More
C.I. D/F Sluice Valves Confirming to IS: 14846-2000 ( Kirloskar or equivalent).Pressure PN 1.6 80mm dia for Scouring purpose

4

-

-

... More
Air Valve (50mm)

6

-

-

... More
Construction of brick masonry Sluice valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid

4

-

-

... More
Construction of brick masonry Air valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.

6

-

-

... More
Construction of brick masonry Scour valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.

4

-

-

... More
Construction of RCC Bulk Flow meter chamber including earthwork excavation, 100mm PCC M15 (1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) as leveling course, RCC M25 grade for base slab, side wall & cover slab including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer.

6

-

-

... More
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete. Heavy Duty (Class 'C') 65 mm dia pipe

2642

-

-

... More
Providing, Lowering into trenches with true to alignment, Laying & Jointing of full lenghts of HDPE Pipes of specified grade as per IS:4984-1995 and specifications, with testing of pipe line including supply of jointing materials. PE-100 grade & PN-10 63 mm Dia pipe

3964

-

-

... More
Supply & Laying - Jointing of following dia. D.I. K-7 S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment, making the joints with approved EPDM quailty of rubber gaskets including cost of all jointing materials and testing etc. complete but excluding excavation and backfilling of trenches upto ground level.D.I. Pipe S&S K-7 (CONFORMING TO IS : 8329/2000).with internal cement mortar lining using sulphate resisting cement (SRC) 80 mm dia pipe DI K7

4218

-

-

... More
100 mm dia pipe DI K7

6546

-

-

... More
150 mm dia pipe DI K7

1944

-

-

... More
10% of cost of pipes shall be considered for cost of specials for estimate purpose only

1

-

-

... More
Supplying and fixing of following sizes of valves including carting the same upto site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect but excluding the cost of earth work and construction of chamber. C.I. D/F Sluice Valves Confirming to IS: 14846-2000 ( Kirloskar or equivalent) Pressure PN 1.0 65 mm dia

2

-

-

... More
80 mm dia

3

-

-

... More
100 mm dia

2

-

-

... More
150 mm dia

1

-

-

... More
C.I. Air Valve Double Acting.50mm dia

10

-

-

... More
C.I. D/F Sluice Valves Confirming to IS: 14846-2000 ( Kirloskar or equivalent).Pressure PN 1.0 50 mm dia for Scouring purpose

10

-

-

... More
Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Engineer-in-Charge. 65 mm

2

-

-

7

-

-

... More
100 mm

5

-

-

... More
150 mm

4

-

-

... More
Construction of brick masonry Sluice valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid

8

-

-

... More
Construction of brick masonry Air valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.

10

-

-

... More
Construction of brick masonry Scour valve chamber with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100mm thick leveling course of PCC M15 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.

10

-

-

... More
Construction of RCC Bulk Flow meter chamber including earthwork excavation, 100mm PCC M15 (1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) as leveling course, RCC M25 grade for base slab, side wall & cover slab including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer.

8

-

-

... More
Anchore Block & Thrust Block

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

82.83

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

517.99

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

36259.3

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete

4304.28

-

-

... More
Bridle Path

-

-

-

... More
Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m.

1624.39

-

-

... More
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6.for Bridal Path

928.22

-

-

... More
Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 )

928.22

-

-

... More
Road Cutting and Restoration

-

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately)

3976.5

-

-

... More
Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately)

880.32

-

-

... More
By Mix in Place Method (Construction of granular subbase by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401)

1001.67

-

-

... More
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.)

3976.5

-

-

... More
Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades.)

39764.98

-

-

... More
Tack coat (Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at required rate on the prepared bituminous/granular surface cleaned with mechanical broom.)

34550.2

-

-

... More
Tack coat (Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at required rate on the prepared bituminous/granular surface cleaned with mechanical broom.)

5214.78

-

-

... More
Seal Coat (Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats)

39764.98

-

-

... More
Cement Concrete Pavement (Construction of un reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted, and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )

782.6

-

-

... More
Distribution Tanks

-

-

-

... More
Earth work in hard murum and boulders, excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

12.95

-

-

... More
Providing and laying hand packed stone soling in buildings works with clean hard selected stones, all complete. (Manual

5.18

-

-

... More
Providing and laying cement concrete M-15 grade (1:2:4 mix) i/c centering, shuttering, curing, etc, all complete.

3.89

-

-

... More
1:1.5:3 Mix (1cement, 1.5 coarse sand 3 graded stone aggregate 20mm and down nominal gauge)

44.6

-

-

... More
Providing, fixing and removing form work for casting RCC items as below Raft

9.63

-

-

... More
Column

9.6

-

-

... More
L beam and C beam

26.28

-

-

... More
L wall and C wall

149.64

-

-

29.11

-

-

... More
Supplying, bending and placing in position tor steel reinforcement in all R.C.C works including cost of binding wires, all complete.

5798

-

-

... More
Providing and Laying 12mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete.

174.64

-

-

... More
Provision for construction of outlet chamber of 200 Dia

2

-

-

... More
Providing box drain of 30 cm (ht) x 45 cm (width) internal dimension with 1:2:4 Plum concrete (20mm & down) in side walls thickness of 23 cm (hill side) and 30 cm (road side) and 1:3:6 (20 mm & down) base concrete of thickness of 15 cm with standard specification over 15 cm stone soling including providing & laying guard stones complete, as per the direction of the Engineer in Charge

50

-

-

... More
Pipe Assembly (DI K7), 200 mm dia For inlet Pipe

12

-

-

... More
For Outlet Pipe

12

-

-

... More
For Washout Pipe

12

-

-

... More
Installation of Washout and main valves of 200 mm dia For Inlet

1

-

-

... More
For Outlet

1

-

-

... More
For Washout

1

-

-

... More
Spacials For pipe Assembly 10% of Pipe Providing

1

-

-

... More
Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer-in-charge (20 tonnes capacity). 90 x 60 cm size

4

-

-

... More
Boundary Fencing

23

-

-

... More
Break Pressure Tank/Hydropneumatic Tank 2KL

30

-

-

... More
Staff Quarter

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.

41.17

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size).

2.29

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level

7.73

-

-

... More
All works above plinth level upto floor II level

12.79

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns sides of foundation

11.6

-

-

... More
Columns, piers, abutments, pillars, posts and struts

44.85

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

83.03

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

48.97

-

-

... More
Weather shade, Chajjas, corbels etc., including edges

4.72

-

-

... More
Stairs, (excluding landings) except spiral-staircases

10

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above. Thermo-Mechanically Treated bars of grade Fe-500D or more.

2416.23

-

-

... More
Providing and Laying first class brick masonry in one and half brick thick wall in superstructure with 1:6 cement mortar (1 cement, 6 clean coarse sand) as per the direction of Eng.-incharge including curing etc. all complete.

10

-

-

... More
Providing and Laying first class brick masonry in one and half brick thick wall in superstructure with 1:6 cement mortar (1 cement, 6 clean coarse sand) as per the direction of Eng.-incharge including curing etc. all complete.

21.84

-

-

... More
20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) on External Surface

62.57

-

-

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) internal surface

138.75

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

138.75

-

-

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer

138.75

-

-

... More
Providing and Providing and painting with acrylic exterior paints of quality and make equivalent to EXCEL, WEATHER SHIELD to give an even shade including brushing the surface clean of dirt, dust etc and sand papering and filling the scratches complete on New surface.

62.57

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size). As levelling coarse

37.66

-

-

... More
Providing and Laying white or colored glazed vitrified tiles Pearl (white, marvel Atlanta, jet black etc or equivalent) in flooring, treads of steps landing etc laid on a bed of 15mm, cm 1:3 (1cement, 3coarse sand) finished with flush pointing with white cement slurry.

37.66

-

-

... More
Providing & Laying white or colored glazed vitrified tiles of Orient / Somani or equivalent colour in flooring, treads of steps landing etc laid on a bed of 15mm, cm 1:3 (1cement, 3coarse sand) finished with flush pointing with white cement slurry.

21.8

-

-

... More
Providing and Laying white or colored glazed vitrified tiles Pearl (white, marvel Atlanta, jet black etc or equivalent) in flooring, treads of steps landing etc laid on a bed of 15mm, cm 1:3 (1cement, 3coarse sand) finished with flush pointing with white cement slurry.for Toilet

10

-

-

... More
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Staircase

10

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)

205.49

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)

164.39

-

-

... More
Providing fitting and fixing water proof flush doors shutters, solid block hard core construction with frame of 1st class hard timber, with well matched 3mm commercial ply (both faces) including hinges with screws complete. Pre-laminated particle board with decorative lamination on both sides

9.14

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

9.14

-

-

... More
Provision for Water Supply & Sanitation Work etc.

1

-

-

... More
Provision for Electrification work etc.

1

-

-

... More
Provision for Furniture and Furnishing

1

-

-

... More
RCC Retaining Wall

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

1065

-

-

... More
Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete. 1:3:6 mix. (1 cement, 3 coarse sand, 6 stone aggregate of 20mm & down size)

71

-

-

... More
Filling with available excavated earth in trenches, plinth and side of foundation in building works with layers not exceeding 20cm in depth including consolidation of each layer by ramming, watering etc, all complete.

593

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level

581

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above.Thermo-Mechanically Treated bars of grade Fe-500D or more.

52290

-

-

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications

33

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :Side of Foundation

200

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for: Wall

800

-

-

... More
Boundary Wall

-

-

-

... More
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil.

428.51

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering,

193.88

-

-

... More
Disposal of excavated excess earth away from the site including conveyance of material up to an average lead of 2 Km away from the site and corresponding required lift, loading, unloading etc complete as directed by the engineer-in-charge ( The quantity is net quantity of capacity of tractor after deduction of 20% for looseness ) a) By Mechanical Transport including loading , unloading and stacking (Lead upto 2 Km away from the site)

234.63

-

-

... More
Providing and Laying first class brick masonry in one and half brick thick wall in superstructure with 1:6 cement mortar (1 cement, 6 clean coarse sand) as per the direction of Eng.-incharge including curing etc. all complete. Cement mortar 1:6 (1 cement : 6 coarse sand).

290.83

-

-

... More
Superstructure Cement mortar 1:6 (1 cement : 6 coarse sand).

484.71

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

95.54

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).

26.69

-

-

... More
Centering and shuttering including strutting , propping etc. and removal of form work. Foundations, footings, bases of columns etc. for mass concrete

300.66

-

-

... More
Columns,Pillars, Piers, Abutments, Posts and Struts

134.88

-

-

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement : 6 coarse sand).

2631.49

-

-

... More
Struck or weathered Pointing on Brickwork with cement and local sand mortar in proportion of 1:3 including supply of all material, labour, etc. required for proper completion of the work.

2358.93

-

-

... More
Providing and Laying damp proof coarse 40 mm thick with cement concrete 1:2:4 ( 1 cement, 2 Clean coarse sand, 4 graded stone aggregate 12.5 mm & nominal size) as per the direction of Engineer in Charge.

195.29

-

-

... More
Penetration Coat Over Top Layer of Crushed Cement Concrete Base (Spraying of bitumen over cleaned dry surface of crushed cement concrete base at the rate of 25 kg per 10 sqm by a bitumen pressure distributor, spreading of key aggregates at the rate of 0.13 cum per 10 sqm by a mechanical gritter and rolling the surface as per clause 506.3.8)

195.29

-

-

... More
Distempering with dry distemper on New surface two or more coats of required shade to give an even and uniform shade including priming coat of whiting to give an even shade after thorough cleaning of dirt, dust, loose pieces of scabs, grease etc including surface preparation by sand papering etc complete. New surface. a) Two or more coats on new work

4990.41

-

-

... More
Providing and fixing concertina coil fencing with required dia 610 mm(having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 apart and with 9 horizontal R.B.T. stud tied with G.I. staple

850

-

-

... More
Corner angle 40x40x5mm "Y" Shape

1898.1

-

-

... More
M.S. Gate and Wicket Gate

-

-

-

... More
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil.

1.09

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering,

0.44

-

-

... More
Disposal of excavated excess earth away from the site including conveyance of material up to an average lead of 2 Km away from the site and corresponding required lift, loading, unloading etc complete as directed by the engineer-in-charge ( The quantity is net quantity of capacity of tractor after deduction of 20% for looseness ) a) By Mechanical Transport including loading , unloading and stacking (Lead upto 2 Km away from the site)

0.65

-

-

... More
Providing and Laying first class brick masonry in one and half brick thick wall in superstructure with 1:6 cement mortar (1 cement, 6 clean coarse sand) as per the direction of Eng.-incharge including curing etc. all complete. Superstructure Cement mortar 1:6 (1 cement : 6 coarse sand).

5.47

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

0.38

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).

0.07

-

-

... More
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).

0.88

-

-

... More
Centering and shuttering including strutting , propping etc. and removal of form work. Foundations, footings, bases of columns etc. for mass concrete

1.92

-

-

... More
Columns,Pillars, Piers, Abutments, Posts and Struts

9.8

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

0.13

-

-

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement : 6 coarse sand).

11.38

-

-

... More
Providing and Laying damp proof coarse 40 mm thick with cement concrete 1:2:4 ( 1 cement, 2 Clean coarse sand, 4 graded stone aggregate 12.5 mm & nominal size) as per the direction of Engineer in Charge.

0.72

-

-

... More
Penetration Coat Over Top Layer of Crushed Cement Concrete Base (Spraying of bitumen over cleaned dry surface of crushed cement concrete base at the rate of 25 kg per 10 sqm by a bitumen pressure distributor, spreading of key aggregates at the rate of 0.13 cum per 10 sqm by a mechanical gritter and rolling the surface as per clause 506.3.8)

0.72

-

-

... More
Distempering with dry distemper on New surface two or more coats of required shade to give an even and uniform shade including priming coat of whiting to give an even shade after thorough cleaning of dirt, dust, loose pieces of scabs, grease etc including surface preparation by sand papering etc complete. New surface. a) Two or more coats on new work

11.38

-

-

... More
Vertical Member - MS Flat (6 X 50 mm)

117.88

-

-

... More
MS Sheet (6 mm)

500.47

-

-

... More
Angle (50 X 50 X 5)

7.68

-

-

... More
Providing and fixing ISI marked oxidised MS door latches conforming to IS : 5930 with screws etc. complete a) 300 X 20 X 6 mm

1

-

-

... More
Bright Finished or black enameled mild steel butt hinges (125 X 65 X 2.12 mm)

4

-

-

... More
Carriage of structural steel and Labour for fixing of door Hinges & Bolt, etc. and applying paint on steel work

1

-

-

... More
MS Sheet (6 mm)

228.42

-

-

... More
Bright Finished or black enameled mild steel butt hinges (125 X 65 X 2.12 mm)

2

-

-

... More
Providing and fixing ISI marked oxidised MS door latches conforming to IS : 5930 with screws etc. complete a) 300 X 20 X 6 mm

1

-

-

... More
Carriage of structural steel and Labour for fixing of door Hinges & Bolt, etc. and applying paint on steel work

1

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc. complete. a) On Steel work

0.72

-

-

... More
House Service Connection

-

-

-

... More
Providing House service connection including saddle, ferrule, GI pipe and fittings, water meter box, ball valve, icluding all ancillary items for the following sizes- 15 mm

1152

-

-

... More
20 mm

576

-

-

... More
25 mm

576

-

-

... More
Providing of all materials, Carting from site store to site of work, Laying & Jointing of GI pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete. 15 mm dia

4608

-

-

... More
20 mm dia

2304

-

-

... More
25 mm dia

2304

-

-

... More
32 mm dia

4606

-

-

... More
Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed) 20 mm dia

10368

-

-

... More
25 mm dia

3456

-

-

... More
32 mm dia

6909

-

-

... More
P/F Multijet domestic mechanical Water Meter Class-B, dry dial, magnetically coupled, temper proof confinning to IS: 779- I 994 or ISO: 4064 IP68 in position including all material, labour, T &P etc complete. 15 mm

1152

-

-

576

-

-

576

-

-

... More
Chamber for HSC

-

-

-

... More
Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately)

193.62

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.

1272.36

-

-

... More
Disposal of excavated earth

954.27

-

-

... More
Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete.

193.62

-

-

... More
Providing and Laying first class brick work in one brick thick in superstructure of standard size bricks with 1:5 cement mortar (1cement and 5 clean coarse sand) as per the direction of Engineer in Charge including curing etc all complete.

359.58

-

-

... More
Providing and Laying 12mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete(1:3 Mix)

1327.68

-

-

... More
Providing and Laying 20mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing etc all complete.(1:4 Mix)

1585.84

-

-

... More
Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete.(In Coping)M-20

147.52

-

-

... More
Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)

1373.78

-

-

... More
Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer-in-charge (20 tonnes capacity). 90 x 60 cm size

461

-

-

... More
Instrumentation/Automation (SCADA) Centralised SCADA Control Room

-

-

-

... More
Control room for remote communication with all RTU Panel, Field Instruments of all DMA areas of entire package with Centralised SCADA Control Room for controlling all proposed/exsiting Water Supply system Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size 1200 mm x 800 mm x 2100mm (lbh) , fabricated out of approx.min. 2 mm thick CRCA sheet Steel complete with latest configuration PC, necessary programming and Scada software and comprising of all accessories Not limited to the following CENTRALISED REDUNDANT PROCESSOR For all RTU Station GIS based Communication, all field Instrument & Radio frequency based AMR Meter communication

1

-

-

... More
FOR DI CHANNEL-Card with 16 channel & with base channels

2

-

-

... More
FOR DO CHANNEL-Card with 16 channel & with base channel

2

-

-

... More
RELAY CARD - with 8 channels

4

-

-

... More
AI CHANNEL - card with 8 channels & with base channels

2

-

-

... More
AO CHANNEL- card with 4 channels & with base channels

2

-

-

... More
SCADA Software & Centralised Cloud Based System, Data Acquisition & Remote Monitoring etc.

1

-

-

... More
Programming Software

1

-

-

... More
Communication Card With Cable

1

-

-

... More
System Cabinet/ Panel

1

-

-

... More
24V Dc Power Supply Redundant

1

-

-

... More
Remote I/O Panel

1

-

-

... More
Server

1

-

-

... More
Marshalling Panel

1

-

-

... More
Hardware Switchgear Lot

1

-

-

... More
Computer-32"LED –Engg. Stn.1No .& Operating Stn-1 Nos.. Total -2 Nos.

2

-

-

... More
Common Desktop for Centralised SCADA Centre

2

-

-

... More
Lazer Printer-A4- Colour

1

-

-

... More
Printer

1

-

-

... More
Aux. Contactor-Lot

1

-

-

... More
Furniture

1

-

-

... More
Air Conditioner-1.5 T

2

-

-

... More
UPS-Redundant 2Kva, 150 AH*2 Battery Unit, Backup For 3 Hours Backup

1

-

-

... More
Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End

1

-

-

... More
iRTU PANEL WITHOUT HMI AT FIELD LOCATION Design, manufacture, supply, installation, testing & commissioning of indoor type PLC panel with 10” HMI , with size 800 mm x 800 mm x 2100mm (lbh) , fabricated out of approx. min. 2 mm thick CRCA sheet complete with , necessary programming and HMI software and comprising of all accessories not limited to the following REDUNDANT PROCESSOR with 48nos. I/O capacity with 10” HMI

8

-

-

... More
FOR DI CHANNEL-Card with 16 channel & with base channels

16

-

-

... More
FOR DO CHANNEL-Card with 16 channel & with base channel

16

-

-

... More
RELAY CARD - with 8 channels

16

-

-

... More
AI CHANNEL - card with 8 channels & with base channels

8

-

-

... More
AO CHANNEL- card with 4 channels & with base channels

8

-

-

... More
Communication Card With Cable

8

-

-

... More
System Cabinet/ Panel

8

-

-

... More
Power Supply Redundant

8

-

-

... More
Hardware & Software Development –Lot

8

-

-

... More
Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End With Dual Sim

8

-

-

... More
UPS- 2 Kva with 150 AH*2 Battery Unit, Backup For 3 Hours for all RTU Panel Location

8

-

-

... More
ELECTROMEGNATIC FLOW METER & TRANSMITTER: DATA LOGER & COMMUNICABLE WITH RTU/SCADA INTEGRATED FLOW METER & TRANSMITTER: Supply, Installation, testing and commissioning of Battery powered Electromagnetic flow meters with GSM/GPRS based with an accuracy of ± 1% of measured value, ingress protection Electronics IP 66 and flow tube IP 68, MOC: lining Neoprene rubber/Hard rubber/PTFE, Flange - SS316/SS304/MS/CS, Electrode - SS 316/Hastalloy, Coil Housing - SS, battery life of min. 5 years, LCD display 5 digit for instantaneous flow and 9 digit for Totalized flow as per technical specifications of following sizes: DN65 mm

2

-

-

... More
DN80 mm

2

-

-

... More
DN100 mm

2

-

-

... More
DN150 mm

6

-

-

... More
DN200 mm

5

-

-

... More
ELECTRICALLY OPERATED SLUICE/FLOW CONTROL VALVE WITH MANUAL OPERATING HANDEL, REMOTELY COMMUNICABLE WITH iRTU / PLC / SCADA FOR ON/OFF COMMAND with 4-20mA Signal DN150 mm

4

-

-

... More
DN200 mm

3

-

-

... More
PRESURE TRANSMITTER: PRESURE TRANSMITTER AT CRITICAL LOCATION WITH LOCAL DISPLAY- FOR ONLINE PRESSURE MEASUREMENT AND DATA LOGGER & RTU/SCADA INTEGRATED Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP68

6

-

-

... More
LEVEL TRANSMITTER: LEVEL TRANSMITTERS- ULTRASONIC TYPE WITH DATA LOGER & RTU/SCADA INTEGRATED Providing, Installation Testing And Commissioning Of Ultrasonic Level Transmitter: Principle : Time Of Flight /Sensor Moc: PP/ Process Connection:1 1/2 Inch / 2 Inch, NPT Threaded Type Power Supply: 24 V DC / Output: 4- 20 mA / Display:Integral Display For Programming And Display Reading / IP 68

6

-

-

... More
ONLINE pH ANALYSER WITH LOCAL DISPLAY: WITH DATA LOGER WITH iRTU/PLC/SCADA INTEGRATED pH Analyser: Transmitter: Range: 0-14 pH, Power Supply 230 VAC, Input: One Digital Sensor, Output: 4-20mA HART, IP68 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ flow through tee MOC SS.

1

-

-

... More
ONLINE TSS ANALYSER WITH LOCAL DISPLAY: WITH DATA LOGER WITH iRTU/PLC/SCADA INTEGRATED TSS Analyser with Transmitter and Sensor Measuring Range: 0-10 mg/L, Accuracy: ≤ 3%, Resolution: ≤ 0.15 mg/L, Operating Temperature: 0- 40°C, Cleaning: Automatic Self-Cleaning using compressed Air. With inbuilt transmitter with 4-20 mA output , Relay contacts & Modbus communication.

1

-

-

... More
ONLINE Turbidity ANALYSER WITH LOCAL DISPLAY: WITH DATA LOGER WITH iRTU/PLC/SCADA INTEGRATED Providing, installation, testing and commissioning of Turbidity Analyser : Range - Selective 0 to 4000 NTU, Accuracy:+/-2% of reading or +/-0.02NTU; Compliance to US EPA180.1, With inbuilt transmitter with 4-20 mA output , Relay contacts & Modbus communication.

1

-

-

... More
ONLINE CLORINE ANALYSER WITH LOCAL DISPLAY:WITH iRTU/PLC/SCADA INTEGRATED Chlorine Analyser : Transmitter : Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for chlorine and second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range: 0.05 to 20 mg/l.

1

-

-

... More
EARTHING SYSTEM : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

8

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

300

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

100

-

-

... More
INSTRUMENT POWER CABLE & INSTRUMENT COMMUNICATION CABLE AND ACCESSORIES Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-.2009. 1.5.0 Sq.mm 2 core Cu Armoured 1.1/0.750 Kv LV cable for instrument power up of voltage rating 230VAC/ 415VAC

300

-

-

... More
0.75/1.0 Sq.mm Cu Armoured communication cable 2 Core Cable

100

-

-

... More
0.75/1.0 Sq.mm Cu Armoured 6 Core Communication Cable

100

-

-

... More
0.75/1.0 Sq.mm Cu Armoured 12 Core Communication Cable

100

-

-

... More
Perforated Cable Tray Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness

300

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
Instrumentation & SCADA Fittings, accessories and other Consumable item Estimate

1

-

-

... More
Cartage

-

-

-

... More
Cartage of Pipe

1

-

-

... More
Carriage for Civil, Electrical & Mechanical Items (Cement, Sand, Aggregate, Steel etc)

1

-

-

... More
DG Set

-

-

-

... More
Provision for Backup DG at WTP

1

-

-

... More
SEWERAGE WORKS

-

-

-

... More
Earthwork Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Soil mixed with boulder,shingle & kankar etc. 0 to 1.5 m below G.L

9891

-

-

... More
1.5 to 3.0 m below G.L

2447

-

-

... More
3 to 4.5 m below G.L

160

-

-

... More
4.5 to 6.0 m below G.L

7

-

-

... More
Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Weatherd, Decomposed or Soft Rock 0 to 1.5 m below G.L

2473

-

-

... More
1.5 to 3.0 m below G.L

612

-

-

... More
3 to 4.5 m below G.L

40

-

-

... More
4.5 to 6.0 m below G.L

2

-

-

... More
Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Hard Rock 0 to 1.5 m below G.L

50

-

-

... More
1.5 to 3.0 m below G.L

50

-

-

... More
3 to 4.5 m below G.L

20

-

-

... More
Excavation for roadway in marshy soil with hydraulic excavator 0.9 cum bucket capacity including cutting and loading in tippers and disposal with in all lifts and lead upto 1000 metres, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections. Marshy Soil Soil mixed with morum, shingle & kankar etc 3 m to 4.5 m depth

39.91

-

-

... More
Sand filling inbuilding works in layer not exceeding 20 cum including watering, ramming etc, all complete. as per Drawing & Technical Specification

515

-

-

... More
Excavating, supplying, transporting of local earth (including royalty) by mechanical transport including all lead & lift , loading & unloading at site etc. complete as per the direction of Employer's Representative

1547

-

-

... More
Disposal Of Surplus Excavated Earth (Rock) Carriage of Dump manure by mechanical transport of Excavated Rock upto 5 km lead

6877.19

-

-

... More
Provide & fixing of Open Timbering (covering1/3rd of surface area by planks), in trenches for the following depths below ground level consisting of 40mm thick approved country wood planks for poling board, 125mm × 75mm Indian Salwood walers and 100 mm dia Sal wood ballies for struts at 1.50m interval including removal after laying of sewer(both sides of trenches will be taken as one side for the purpose of payments & measurements i.e. area equals to length x depth of trenches. Dismantled timbering materials will be the property of the contractor. Depth upto 3.0m below G.L

1674

-

-

... More
3 m to 6 m below G.L

9

-

-

... More
Provide & fixing of Close Timbering in trenches for the following depths below ground level consisting of 40mm thick approved country wood planks for poling board, 125mm × 75mm Indian Salwood walers and 100 mm dia Sal wood ballies for struts at 1.50m interval including removal after laying of sewer(both sides of trenches will be taken as one side for the purpose of payments & measurements i.e. area equals to length x depth of trenches. Dismantled timbering materials will be the property of the contractor. Depth upto 3 m below G.L

2511

-

-

... More
3 m to 6 m below G.L

13

-

-

... More
Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). Depth upto 1.5 m

3316

-

-

... More
Depth exceeding 1.5m but not exceeding 3.0m

2056

-

-

... More
Depth exceeding 3 m but not exceeding 4.5 m

105

-

-

... More
Steel shoring in trenches including strutting , shoring and packing cavities where required complete including all material, labour, tools etc. with all lead and lift complete in all working conditions like subsoil, water etc. and as directed by the Engineer -in-charge. (Measurement to be taken of the face area provided with shoring) Depth upto 1.5 m

20

-

-

... More
Depth exceeding 1.5m but not exceeding 3.0m

20

-

-

... More
Dewatering of water caused due to seepage of ground water and surface water due to rain etc. excluding excavation of foundation but during execution of civil works including supply of all machine operator, khalashi, POL, T&P, accessories required for proper completion of the work. 5 % Of Excavation Cost- For Rangpo

1

-

-

... More
Providing and fixing Barricading at site of work for restricting the general public using 80-100 mm dia Wooden Ballies as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing two rows of 80-100 mm Wooden Ballies as horizontal members with jute russies. Both vertical and horizontal members shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading holes shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis)

1049

-

-

... More
Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe ("B" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing two rows of 40 mm dia M.S. pipe ("B" class) as horizontal members with nuts & bolts. Both vertical and horizontal members shall be painted in red and white colour strips as per approved pattern as when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading holes shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis)

4196

-

-

... More
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge.(Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).

150

-

-

... More
Installlation of HDPE product pipe by HDD method for on gravity sewer including preparing and setting up the plant & equipment, preparing new pipe work, making of entry & exit pit upto 1.5 meter depth, installing new pipe work and commissioning system or making the system ready for commissioning by HDD operation including all related civil and mechanical work like excavation , shoring/strutting etc, drilling, stringing, reaming and pulling back the new pipe work on the designed bore path alignment, proper disposal drilling fluid, and backfill of site after completion all inclusive as per IndSTT latest revision Pipe dia between 110 mm & 225mm dia in mixed Strata

30

-

-

... More
HDPE pipe between 250 mm & 315 mm outer dia in mixed Strata

30

-

-

... More
HDPE pipe between 355 mm & 450mm outer dia in mixed Strata

30

-

-

... More
Installlation of product pipe by Auger Boring method including making of entry and exit pits, all related cilvil works like excavation, shoring/strutting, etc., manual shielded excavation, lowering of pipe segments in the jacking pit, laying and jointing of product pipeline through jacking process from the jacking pit after project completion as per the intructions of the Engineer-in-Charge all complete except the cost of the pipe. Above 300 and upto 450 mm dia in all type of Soil

30

-

-

... More
Installlation of product pipe by Micro Tunneling method including making of entry and exit pits, all related cilvil works like excavation, shoring/strutting, etc. And Ground Penetrating Radar survey, to protect any existing utilities at pipe installation location and restoration of site after complition. (Upto 100 meter installation length ) Above 300 mm dia upto 450 mm dia in mixed strata

30

-

-

... More
Providing & laying Granular bedding with graded hard crusher broken stone of 100% passing through 20mm sheive, 20 to 50 % passing through 10mm sheive and 100 % retain on 6.3mm sheive, laying in layers of thickness 10/15cm including ramming, consolidation etc complete for all type of pipes of following sizes as per drawing and or as directed by Engineer.

1080.39

-

-

... More
Rectification of Exisiting Water supply House service connection damaged during execution including all civil work, pipe work , specilas & fittings , T&P etc all complete require to proper functioning of exisitng connection. For Rangpo

175

-

-

... More
Pipe line work

-

-

-

... More
Supply & Laying - Jointing of following dia. D.I. K-7 S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment, making the joints with approved EPDM quailty of rubber gaskets including cost of all jointing materials and testing etc. complete but excluding excavation and backfilling of trenches upto ground level.D.I. Pipe S&S K-7 (CONFORMING TO IS : 8329/2000) with internal cement mortar lining using High Alumina Cement (HAC) 200 mm dia

6665

-

-

... More
250mm dia

351

-

-

... More
300mm dia

190

-

-

... More
400mm dia

412

-

-

... More
200 mm dia K-9 For pumping main

50

-

-

... More
Add 10 % Extra for Pipe Fitting Total Cost of pipe providing

1

-

-

... More
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete.G.I. PIPE CONFORMING TO IS : 1239(PART-1) 15 mm dia

150

-

-

... More
20 mm dia

150

-

-

... More
25 mm dia

150

-

-

... More
Providing, lowering, laying & jointing MDPE/ HDPE pipes (Class-PE 80) PN 12.5 composite pipes for extra length for house service connections as per drawing and specifications complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer 20 mm dia

100

-

-

... More
25 mm dia

100

-

-

... More
32 mm dia

100

-

-

... More
Providing, Lowering into trenches with true to alignment, Laying & Jointing of full lenghts of HDPE Pipes of specified grade as per IS:4984-1995 and specifications, with testing of pipe line including supply of jointing materials. 200 mm dia pipe

30

-

-

... More
250 mm dia pipe

30

-

-

... More
315 mm dia pipe

30

-

-

... More
355 mm dia pipe

30

-

-

... More
Sewer Appurtenances Work

-

-

-

... More
Construction of brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement: 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. Manhole Cover with Frame 560 mm dia (HD 20) as per IS 12592. including centering, shuttering all complete. (Excavation, foot rests and 20mm thick cement plaster in CM (1:4) at the external surface shall be paid for separately) :With Sewer bricks conforming to IS : 4885

169

-

-

... More
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m.With Sewer bricks conforming IS : 4885

20

-

-

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :1.68 m deep 560 mm Dia CO Ductile iron Manhole cover with frame having load capacity of D400, hinged type (Anti theft ), including centering, shuttering all complete. (Excavation, foot rests and 20mm thick cement plaster in CM (1:4) at the external surface shall be paid for separately) :With Sewer bricks conforming to IS : 4885 including providing & fixing of stainless steel safety chain SS-316 in manholes to keep workers from being swept away while they are inside.

84

-

-

... More
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :With Sewer bricks conforming IS : 4885

26

-

-

... More
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep 560 mm Dia CO Ductile iron Manhole cover with frame having load capacity of D400, hinged type (Anti theft ), including centering, shuttering all complete. (Excavation, foot rests and 20mm thick cement plaster in CM (1:4) at the external surface shall be paid for separately) :With Sewer bricks conforming to IS : 4885 including providing & fixing of stainless steel safety chain SS-316 in manholes to keep workers from being swept away while they are inside.

85

-

-

... More
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :With Sewer bricks conforming IS : 4885

37

-

-

... More
Providing and constructing RCC circular manhole of various diameters and depths with RCC M 30 and as per drawing. RCC base over PCC M15 (1:2:4) bed and RCC wall, preparation of channel and PCC M15 (1:2:4) benching, fixing of manhole frame & its cover, RCC-M20 cover slab of suitable thickness ,centering and shuttering, providing and fixing PVC encapsulated footsteps of approved make and quality, 560 mm Dia CO Ductile iron Manhole cover with frame having load capacity of EHD 35 , hinged type (Anti theft ), suitable connection of inlet and outlet pipes, curing ,testing of manholes (including the cost of manhole cover , frame & reinforcement steel ) complete as per specification and drawing and as directed by the Engineer. Note:- Excavation of earth work and road cutting for manhole will be measured and paid separately. Item including providing & fixing of stainless steel safety chain SS-316 in manholes to keep workers from being swept away while they are inside. 900 mm internal diameter Concrete Manhole Type-A of Depth start from 910 mm

77

-

-

... More
Extra depth for concret manhole Type A depth beyond 910 mm upto 1610 mm

5

-

-

... More
1200 mm internal diameter Concrete Manhole Type-B of Depth start below 1610 mm

21

-

-

... More
Extra depth for concret manhole Type B depth beyond 1610 mm upto 2110 mm

7

-

-

... More
1500 mm internal diameter Concrete Manhole Type-C of Depth start below 2210 mm

21

-

-

... More
Extra depth for concret manhole Type C depth beyond 2210 mm upto 5000 mm

9

-

-

... More
Providing HDPE/DI pipes as per IS 14333 drop connection externally for drop depth 0.60 m drop from branch sewer line to main sewer manhole or vise versa including inspection and cleaning eye, HDPE/DI drop pipe and bend encased around with cement concrete M15 with all form work, cutting holes in walls and making good with brick/ stone masonry work in cement sand mortar 1:4 plastered with cement sand mortar 1:3 with stiff cement mortar 1:1 around HDPE pipe in masonry wall, making required channels complete as per standard design and specifications and/ or as the directed of the Engineer. 200 mm dia

226

-

-

... More
250 mm dia

10

-

-

... More
300 mm dia

5

-

-

... More
400 mm dia

11

-

-

... More
Extra for additional drop depth of HDPE/DI pipes as per IS 14333 drop connection beyond 0.6 m complete as per standard specification and the direction of the Engineer. 200 mm dia

196.62

-

-

... More
250 mm dia

8.7

-

-

... More
300 mm dia

4.35

-

-

... More
400 mm dia

9.57

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). Used for pipe bedding at River & Nallah crossing

12

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(RCC arch bedding for encasing the pipe for river & Nallah crossing)

57

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

5700

-

-

... More
Providing, fixing and erecting precast RCC (M20) Vent shaft with cowl, 125mm and 225mm internal and external dia respectively at top, 300mm and 450mm internal and external dia at bottom and 9.0m over all length, bottom 1.175m below ground level fixed in the pit 900mmx900mmx1500mm with PCC M15, 250mm in bed and minimum 200mm all around with top 150mm in PCC M15 with 20mm nominal size graded stone aggregate , junction of vent shaft and concrete grouted with cement mortar 1: including making connection with sewer manhole with 150mm dia NP4 RCC pipe (IS 458-ammended upto date) as required including Type-A bedding complete as per standard design and finished with water proof cement of approved brand as per drawings and/or as directed by Engineer.

9

-

-

... More
Providing and Laying 20mm thick cement plaster of specified mix with Recorn 3S having a fiber length of 4.8 mm ( 100 gm / bag of cement) in single coat including finishing even and smooth and curing etc all complete . mix :1:4 (1 cement: 4 coarse sand)

1970

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

3578

-

-

... More
Supply & Fixing 0.56 m Internal dia Anti-theft D.I. air-tight manhole cover with frame (Heavy duty minimum weight 80 kg.) with locking arrangement of material grade SG-500/7 as per IS 1865-1991 with grade designation c-250 as per EN-124 Ductile Iron, including testing and inspection as per guidelines of IS specifications , painting with sulphate resisting paint/ Bituminous paint.(Payment shall be made to the contractor on actual executed quantity basis and proportionately amount of SFRC manhole cover (with frame) shall be deducted from respective manhole). All as per technical specification, drawing and as directed by Engineer-in-charge.

23

-

-

... More
Supply & Fixing 0.56 m Internal dia Anti-Theft D.I. air-tight manhole cover with frame (Extra heavy duty minimum weight 95 kg.) with locking arrangement of material grade SG-500/7 as per IS 1865-1991 with grade designation d-400 as per EN-124 Ductile Iron, including testing and inspection as per guidelines of IS specifications , painting with sulphate resisting paint/ Bituminous paint.( Payment shall be made to the contractor on actual executed quantity basis and proportionately amount of SFRC manhole cover (with frame) shall be deducted from respective manhole). All as per technical specification, drawing and as directed by Engineer-in-charge.

23

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.EHD - 35.Circular shape 560 mm internal diameter.

50

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.H D - 20.Circular shape 560 mm internal diameter.

50

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.H D - 10.Circular shape 560 mm internal diameter.

50

-

-

... More
Providing & Laying 230 mm thick Rubble/Stone Soling below PCC of Manhole in case of weak Soil Strata 910 mm dia ( Brick Manhole)

41.55

-

-

... More
1220 mm dia ( Brick Manhole)

27.1

-

-

... More
1520 mm dia ( Brick Manhole)

34.58

-

-

... More
900 mm dia (RCC Manhole)

18.4

-

-

... More
1200 mm dia (RCC Manhole)

6.56

-

-

... More
1500 mm dia (RCC Manhole)

9.57

-

-

... More
Sewer House Sewer connection

-

-

-

... More
Providing ,laying & jointing of sewer house service connection to individual housess from chamber inside the property to either road side chamber or street manhole .Works includes supply and delivery of plain ended with integral sockets plasticised polyvinylchloride (uPVC) Pipes with ISI mark intended for underground (buried)_ non pressure gravity sewer applications conforming to IS:15328:2003 with latest amendments for different sizes and stiffness classes as per specifications including identification of location of existing chamber / sleeve.The pipes may be joined using elastomeric sealing rings.The elastomeric sealing rings required for jointing of ring tight uPVC Pipes and shall in aacordance with one of the types (Type 1 to Type 6) of IS 5382. Including excavation (in water mud or under foul condition, dismantling of all type of roads like BT, CC, Stone, Paver blocks (all thickness and sizes), and floors likes kota stone, tile, manhole etc. Or any other type of floooring as per site condition, dewatering, refilling, compaction and disposal of surplus earth / unserviceable materials with all lead and lift at suitable disposal site as directed by Engineer. Making conncetion of drain or sewer line with existing manhole including breaking into and making good the walls, floors, with cement concrete. The uPVC specials like bends, tees, couplers,etc.) shall be provided as per site condition .All transportation,loading and unloading ,conveying to site,lowering ,laying and jointing of pipes, 75 mm thick sand/concrete bedding all around the pipe as per drawing and specifications shall be inclusive complete the work in all respect and as per specification and as directed by the Engineer -in-charge .The PVC resin shall be of grade 67 ER 092 for S16.5 series ,SDR 34,SN-8.(CC Floor restoration shall be paid saparately ) 110 mm dia (Outer diameter)

4580

-

-

... More
160 mm dia (Outer diameter)

2748

-

-

... More
Construction of chamber in side the premises of individual houses with clear inside opening of 300*300 mm having depth as per site condition with 230 mm thick Brick (FPS bricks of class designation 7.5) Masonary in CM 1:4 (1 cement : 4 coarse sand ), including inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls, 20 mm thick plaster on external surface with cement mortar 1:4 (1 cement : 4 coarse sand ) and bed concrete ,PCC M-15(1:2:4) (1 cement :2 fine aggregate : 4 course aggregate ) for bed of 150 mm thick & benching of as per drawing with precast (LD-2.5) cover slab .The work includes Coping in M-20 for fixing of frame,excavation ,refilling of excavated material with compaction ,fixing of uPVC Pipe of 110 mm dia as required .Work should be completed in all repect as per specifications ,drawing and as per directions of Engineer-in-charge. (for HSC

733

-

-

... More
Construction of chamber out side the premises of individual houses with clear inside opening of 400*400 mm having depth upto 750 mm 230 mm thick Brick (FPS bricks of class designation 7.5) Masonary in CM 1:4 (1 cement : 4 coarse sand ), including inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete , 20 mm thick plaster on external surface with cement mortar 1:4 (1 cement : 4 coarse sand ) and PCC M-15(1:2:4) (1 cement :2 fine aggregate : 4 course aggregate ) for bed of 150 mm thick & benching of as per drawing with precast (LD-2.5) cover slab .The work includes Coping in M-20 for fixing of frame,excavation ,refilling of excavated material with compaction ,fixing of uPVC Pipe of 110 mm dia as required .Work should be completed in all repect as per specifications ,drawing and as per directions of Engineer-in-charge.

344

-

-

... More
Construction of chamber out side the premises of individual houses with clear inside opening of 450*450 mm having inside depth upto 750 mm with 230 mm thick Brick (FPS bricks of class designation 7.5) Masonary in CM 1:4 (1 cement : 4 coarse sand ), including inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete, 20 mm thick plaster on external surface with cement mortar 1:4 (1 cement : 4 coarse sand ) ,PCC M-15(1:2:4) (1 cement :2 fine aggregate : 4 course aggregate ) for bed of 150 mm thick & benching of as per drawing with precast (MD-10) cover slab .The work includes Coping in M-20 for fixing of frame,excavation ,refilling of excavated material with compaction ,fixing of uPVC Pipe of 110 mm dia as required .Work should be completed in all repect as per specifications ,drawing and as per directions of Engineer-in-charge.

10

-

-

... More
Extra for over depth beyond 750 mm upto 1000 mm for property chamber

1

-

-

... More
Supply & Fixing 450 mm square shape chamber cover with frame (Medium duty minimum weight 10 kg.) with locking arrangement of material grade SG-500/7 as per IS 1865-1991 with grade designation c-250 as per EN-124 Ductile Iron, including testing and inspection as per guidelines of IS specifications , painting with sulphate resisting paint/ Bituminous paint. (Payment shall be made to the contractor on actual executed quantity basis and proportionately amount of pre-cast rcc cover (with frame) shall be deducted from respective chamber ). All as per technical specification, drawing and as directed by Engineer-in-charge.

2

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.M D - 10.Square shape 450 mm internal dimension

10

-

-

... More
Supply,Installation,Testing, commissioning of PolyPropylene (PP) inspection chamber with heavy duty frame & cover with risers as per the site condition as per relevant Standard acceptable to the Employer including earth work, cement concrete in 1:3:6 in foundation & sides etc complete as per the direction of Employer's Representative.- 450 mm Internal Diameter and depth upto 450 mm

40

-

-

... More
extra for over depth beyound 450 mm

10

-

-

... More
Miscellaneous Works

-

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

100

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

10

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

10

-

-

... More
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin- charge.

10

-

-

... More
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.

10

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar

10

-

-

... More
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar

100

-

-

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

100

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

100

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

10

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)

50

-

-

... More
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

50

-

-

... More
Construction of 3.75 meter (Carriage width) wide approach road for STP site as per Technical Specification and Direction of Engineer-In-Charge

40

-

-

... More
Providing and Laying Random Rubble Stone Masonry in 1:3:6 c.c. (1 cement, 3 sand, 6 clean hard graded stone chips, size 40mm gauge) including bond stone, through stone of size 150mm x 150mm x 450mm manufactured in 1:4:8 (1cement, 4 clean coarse sand, 8 clean hard stone aggregate of size 40 mm and down) and curing etc, complete as per the direction of Engineer in Charge, excluding the cost of carriage of materials.

50

-

-

... More
100 m Length of RCC Retaning wall around STP

1

-

-

... More
Construction of Boundary Wall around STP Premises along with Gate - 100 Mtr

1

-

-

... More
G.I. Chain Link Fabric Fencing (PVC Coated) around green belt outsite STP Premises along with gate - 200 Mtr

1

-

-

... More
Cartage

-

-

-

... More
Cartage of Pipe

1

-

-

... More
Carriage for Civil, Electrical & Mechanical Items (cement, sand, aggregate, steel etc)

1

-

-

... More
DG Set

-

-

-

... More
Provision for Backup DG at STP of Singtam

1

-

-

... More
Environmental monitoring cost

-

-

-

... More
Air quality monitoring

50

-

-

... More
Noise quality monitoring

50

-

-

... More
Ground water quality monitoring

50

-

-

... More
Surface water quality monitoring

50

-

-

... More
Soil quality monitoring

50

-

-

... More
Schedule 4:STP, SPS, Package STP & Septage and Its ancillary works For Singtam

-

-

-

... More
STP Design, proof-checking, construction, testing, and commissioning of 2.5 MLD Sewage Treatment Plants (STPs) based on Sequencing Batch Reactor (SBR) technology, integrated with SCADA for automation. The STPs will consist of key components, including the Inlet Chamber, Screen Chamber, Detritus Tank, Distribution Chamber, CASP Basins, Sludge Sump, Chlorine Contact Tank, Chlorinator Room, Sludge Centrifuge, Decanting System, Diffusers, Treated Effluent Tank, and Effluent Discharge System up to disposal point. The project scope includes the provision of all necessary piping, valves, gates, drains, pathways, and an Administration Block with a laboratory. Comprehensive civil, electrical, and mechanical works will be undertaken, including HT Substation, transformers, metering cubicle, and instrumentation systems. The STP design shall adhere to relevant standards and regulations, including the CPHEEO Manual, relevant BIS standards, ensuring compliance with NGT guidelines, the Environment (Protection) Rules, 1986, and CPCB norms, as outlined in the project specifications. Including testing, trial run for 3 (three) month of the Plant to the satisfaction of the Engineer

-

-

-

... More
"SCADA for STP should include: 1. Flow Measurement: plant Inlet, outlet, bypass 2. Water Quality: pH, BOD, COD, TSS at plant inlet and outlet 3. ⁠DO Analyzer: at each Sbr basin 4. Pump & Motor Controls: through level transmitter 5. Aeration & Blower Controls: through DO Analyzer 6. Sludge Management: through auto knife gate valve and timer base logic 7. Chemical Dosing: Chlorine, Coagulant/Flocculant, pH Adjustment 8. Level Sensors: at each Tanks & Sumps 9. Temperature Control: at each blower 10. Alarms: Fault, Overflow, Safety 11. Data Logging & Reporting 12. Energy Monitoring 13. Major Valve & Actuator Automation"

-

-

-

... More
For Singtam 2.5 MLD

1

-

-

... More
For climate resilance structure elevated for STP upto 6 m From GL for Singtam

1

-

-

... More
SPS/MPS

-

-

-

... More
Mechanical works at SPS

1

-

-

... More
Electrical works at SPS

1

-

-

... More
SCADA for SPS

1

-

-

... More
Intermediate Sewage Pumping Station (SPS)

1

-

-

... More
Encasing of Pipe

1

-

-

... More
SEPTAGE FSTP Survey, design, drawing, construction, testing and commissioning of Faecal Sludge Treatment Plant (FSTP) of installed capacity with all necessary appurtenant structures (civil and electromechanical) and allied works etc. including all necessary approvals from various government departments etc. including testing, trial run for 3 (three) month of the Plant to the satisfaction of the Engineer – in - Charge For Singtam 1 KLD

1

-

-

... More
PROCUREMENT OF VEHICLE FOR SEPTAGE MANAGEMENT Supply of Suction cum Jetting Machine Cesspool vehicle with Capacity of 3 KL (2 KL- Sludge water tank & 1 KL- Fresh water tank)

1

-

-

... More
Schedule 5: O&M Operation, Maintenance and Management Services for Water Supply System

-

-

-

... More
Operation and maintenance Fee for 5 year Operation Service Period for producing and distribution (24x7) potable water conforming to the relevant Service Levels including all necessary tasks, activities and obligations as necessary for operation, maintenance and management of water production and distribution system and all related infrastructure, Source/Intake, treatment of water at WTP, chlorination for disinfection, water quality testing and monitoring, flow and pressure measurement, management of water distribution to all connected customers, including planning, demand management, DMA and sub-DMA management, network operations, network management, leak detection, leak repair, connections management, all commercial services including meter reading, bill generation, distribution of bills, customer services including recording and redressing customer complaints, all administrative and management tasks and all services to be provided as a prudent water supply service provider as well as cost of incentives, operations, spares, equipment, transport, tankered water supply, including all necessary preventive and reactive maintenance of all civil, mechanical, electrical and instrumentation units, transport, communications, reporting, including cost of all wages, chemicals, Fuel, consumables, spares, insurance, complete. Electricity Charges will be paid by GoS. The bidder shall separately provide the break-up of salaries and wages, consumables, electricity, preventive maintenance for civil, mechanical, electrical and instrumentation, insurance and all other costs in a separate sheet for analysis by EmployerFunctional HSC During Execution and O&M period

20580

-

-

... More
Operation, Maintenance and Management Services for Sewerage System O&M Fee for 5 year Operation Service Period for sewage collection system, conveyance and treating sewage at STP and safe disposal of treated sewage into water body conforming to the relevant Service Levels and Pollution control board norms, including all necessary tasks, activities and obligations as necessary for operations, maintenance and management of sewerage system and all related infrastructure comprising of sewers, house service connection chambers, sewage pumping station(s), sewage treatment plant(s) comprising of screening, grit removal, primary sedimentation (if required), aeration basins, coagulation, secondary sedimentation, filtration (if required), chlorination for disinfection, disposal of sludge, treated sewage, sewage quality testing and monitoring at STP(s), management of sewage collection, conveyance, network management, connections management, all administrative tasks, management tasks and all services to be provided as a sewage management provider etc., as well as cost of management, wages, incentives, operations, maintenance, spares, administration, equipment, transport, operation of sewer cleaning equipment for cleaning of sewers, flushing of sewers using tankers including all necessary preventive and reactive maintenance of all civil, mechanical, electrical and instrumentation units, administration, transport, communications, reporting, including cost of all wages, chemicals, Fuel, consumables, administration, transport, spares, insurance etc., complete. Functional HSC During Execution and O&M period

4200

-

-

... More
Variable O&M Fee for Septage management: For 5 Years Collection of septage from house hold and conveyance to Co-treatment facility at STP and safe disposal into STP for further treatment conforming to the relevelent service levels including all necessary activities and obligation as necessary for suction of septage from septic tanks, house service connection chambers, management of septage collection, conveyance, disposal management, all administrative tasks and all services etc., as well as cost of management, wages, incentives, operations, maintenance, spares, administration, equipment, transport, operation of septage cleaning equipment for cleaning of septic tank by using Suction Machine including all necessary preventive and reactive maintenance of all civil, mechanical, electrical and instrumentation units, administration, transport, communications, management information systems, reporting, including cost of all wages, chemicals, Fuel, consumables, administration, transport, spares, insurance etc., complete.

836

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.