Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Most viewed tenders

Recently Added tenders

Ministry Of Defence

Sri Ganganagar, Rajasthan

  • Opening Date

    03 Sep 2019

  • Closing Date

    13 Sep 2019

  • Tender Amount

    Refer document

  • EMD

    -

Reminder

Follow

Download
Are you Looking for Joint Venture Partners, Contractor Consortium, Back-to-Back Contractor, Project Financier?
We will help you to find the right match for FREE.
Summary

Multipara Monitor - Low End

Don't have sufficient eligibility, BG funds or resources?
We will help you to find the right match for FREE.
BOQ Items

No BOQs Available

Bid Number: GEM/2019/B/340581 Dated: 03-09-2019 Bid Document Bid Details Bid End Date/Time 13-09-2019 14:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 80 (Days) Ministry/State Name Ministry Of Defence Department Name Department Of Defence Organisation Name Indian Army Office Name 316 Fd Hosp Total Quantity 2 Item Category Multipara Monitor - Low End MSE Exemption For Years Of Experience And Turnover No Startup Exemption For Years Of Experience And Turnover No Bid to RA enabled Yes Multipara Monitor - Low End ( 2 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Conformity to Certifications US FDA US FDA, CE European and US FDA Confirmity to Manufacturing Standards ISO 9001 & ISO 13485 ISO 9001 & ISO 13485 Conformity to Safety Standards ISO 80601-2-49 and IEC 60601-1 or BIS equivalent * Performance Parameters Purpose Low-end monitors are designed to perform basic vital-signs monitoring. These monitors may also be * 1 / 7 appropriate for IPD as well as OPD patients Type of Monitor Preconfigured / Non Modular Preconfigured / Non Modular Monitoring Parameters ECG,HR, NIBP, PR, respiratory rate, SpO2, and body temperature * ECG parameters Number of leads of ECG 5 5 12-lead interpretation for ECG No Yes, No Arrhythmia detection and analysis Yes * Number of leads analyzed for ECG in single time 5 5 Heart rate measurement range At-least 30 -250 BPM * Accuracy ± 5 BPM * Minimum gradation 1 bpm * Respiration Parameters Respiration Method Impedance pneumography * Display waveform of respiration Yes * Threshold control for respiration Yes * Respiration rate measurement range At-least 0-100 bpm * Minimum gradation of respiratory measurement 1 BPM * Pulse Oximetry Parameters Measurement technique Others Nellcor, Masimo, Draeger OxiSure, TruSignal, Others Other Measuring Techniques (In case measurement technique is nelcor, masimo , draeger, oxisure, trusignal put NA otherwise indicate the measurement technique) - * Probe type supplied Adult Adult Type of adult probe Reusable Disposable, Reusable, NA 2 / 7 Type of pediatric probe NA Disposable, Reusable, NA Type of neonatal probe NA Disposable, Reusable, NA SPO2 measurement range Atleast 40-70 % & 70 to 99% * Accuracy of SPO2 measurement Better than ±1 % for 40-70 range & better than ± 3 % for 70-99 range * Minimum Gradation 1% * NIBP Parameters Measurement technique for NIBP Step-deflation oscillometric * Cuff supplied Adult,Pediatric Adult, Pediatric, Neonatal Cuff size for Adult Large Small, Medium, Large, Extra Large, Not supplied Cuff size for pediatric Standard Standard, Not supplied Cuff size for neonate Not supplied Standard, Not supplied Blood pressure monitoring range 30-300mm/Hg * Gradation 1 mm/Hg or better * Temperature Parameters Number of channels for temperature 1 1, 2 Probe type skin skin, rectal, esophageal, All ( esophageal, rectal , skin) Temperature probe type Reusable * Temperature probe range Atleast 30 - 40 degree * Minimum gradation of temp probe 1/10 degreeC * Accuracy in % ±1% * Length of time of full disclosure of patient data in hr ≥48 * Operating conditions Capable of operating continuously in ambient temperature of 0 to 50 de c and relative humidity of 15 to 90% in ideal circumstances * 3 / 7 Length of time of trending in hr ≥24 * Alarms Opeartor can set audio visual alarm levels for low or high levels of each parameter independently Yes * Systolic BP - low and high Yes * Diastolic BP - low and high Yes * Mean BP - low and high Yes * Heart rate - low and high Yes * SPO2 - low and high Yes * Respiratory rate - low and high Yes * Temperature -low and high Yes * Alarm Volume should be adjustable Yes * Type of alarm Audio and Visual * Activating silence of alarm Yes * Duration of alarm silence in sec 120 120, 300

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.