Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date24 Sep 2021
Closing Date25 Nov 2021
Tender Amount₹ 20,12,960 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINT OF LT NETWORK (UG CABLES/OH LINES) AND CONNECTED WORK AT OTM OF ZONE B UNDER GE UTILITY BATHINDA.
REPAIR/MAINT OF LT NETWORK (UG CABLES/OH LINES) AND CONNECTED WORK AT OTM OF ZONE B UNDER GE UTILITY BATHINDA.
REPAIR/MAINT OF LT NETWORK (UG CABLES/OH LINES) AND CONNECTED WORK AT OTM OF ZONE B UNDER GE UTILITY BATHINDA.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as Srl iem No 2 here-in-before but for three Nos conductor.

240

-

-

... More
All as Srl iem No 2 here-in-before but for four Nos conductor . Notes for serial item No.02,03,04 & 05 of BOQ : (i) Cost for attending fault, cutting and removal of broken piece of tree / branches, disconnection and jointing of binding wire with insulator, restretching required conductor, making connection with existing cable deemed to be included in quoted rates and nothing shall be paid extra on this account. (ii) If New ACSR conductor,Earth wire requires for this item shall be measured and Paid seperately under appropriate items of Schedule'A' BOQ. (iii) Cost of binding wire and insulators is included in this item and nothing shall be paid extra on this account.

240

-

-

... More
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.

1001

-

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.

609

-

-

... More
Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.

392

-

-

... More
Material & labour sand cushioning using clean Fine River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. ( Note:- Punned thickness shall be considered for payment purpose)

303

-

-

... More
Supply and laying Best quality, locally available, sub class ‘B’ clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.

12.5

-

-

... More
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified and directed.

10000

-

-

... More
Re-laying old serviceable bricks for cable protection , laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.

7

-

-

... More
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as directed.

5300

-

-

... More
Relaying of old serviceable under ground PVC/XLPE LT cable of any grade , any size laid in trenches / fixed to wall / pole / roof / laid in floor including necessary connections and thimbling complete all as specified and as directed.

2000

-

-

... More
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / hard standing /along poles and testing Poly vinyl Chloride (PVC) LT Cable, with PVC outer sheath Type-I as per IS - 5831, insulated stranded aluminium conductor as Per Class-2 of IS - 8130 served with and inner sheathining of PVC tape- ST-I as per IS-5831 color Red, Yellow, Blue & Black ,armoured with Galvanised steel strip or wire and over all PVC sheathed stranded conductor conforming to IS-1554 (Part-I & II) with latest amendments of Size cross sectional area 240 Sqmm 3.5 core ,1100 volts grade heavy duty complete all as specified and as directed.

200

-

-

... More
All as per serial item No. 15 above but for cross sectional area 185 Sqmm 3.5 core ,1100 volts grade.

200

-

-

... More
All as per serial item No. 15 above but for cross sectional area 150 Sqmm 3.5 core ,1100 volts grade.

200

-

-

... More
All as per serial item No. 15 above but for cross sectional area 120 Sqmm 3.5 core ,1100 volts grade.

200

-

-

... More
All as per serial item No. 15 above but for cross sectional area 95 Sqmm 3.5 core ,1100 volts grade.

500

-

-

... More
All as per serial item No. 15 above but for cross sectional area 70 Sqmm 3.5 core ,1100 volts grade.

500

-

-

... More
All as per serial item No. 15 above but for cross sectional area 50 Sqmm 3.5 core ,1100 volts grade.

500

-

-

... More
All as per serial item No. 15 above but for cross sectional area 25 Sqmm 3.5 core ,1100 volts grade.

500

-

-

... More
All as per serial item No. 15 above but for cross sectional area 16 Sqmm 4 core ,1100 volts grade. Note foe serial item No. 13 to 23: Excavation and earth work shall be measured and paid separately under respective item.

500

-

-

... More
Un binding from old insulators and taking down old unservicable insulators and re–stretching only existing ACSR of any size on LT poles including binding the ACSR with new insulators with and including aluminium binding wire 2mm dia complete all as specified and as directed. Note :- (i) The rate of aluminium binding wire 2mm dia is included in this item and nothing shall be paid extra on this account. (ii) New insulators shall be measured and paid seperately under respective item of this scheule of works of BOQ.

200

-

-

... More
All as per srl item No. 24 here-in-before but re–stretching only existing GI earth wire 4 mm dia on LT / HT Poles including binding with 1.63 mm dia GI binding wire all as specified and as directed. Note :- The rate of 1.63 mm dia GI binding wire is included in this item and nothing shall be paid extra on this account.

20

-

-

... More
Cutting / trimming of tree branches upto 1.50 metre distance on each side and 3.00mtr distance on both sides of LT over head lines including collection and removal from road complete all as directed. Note : For measurement and payment purpose each span shall be considered as 40.00 mtr. Span.If the length of span is less than 40.00 mtr measurment and payment shall be considered proportionally.

800

-

-

... More
Supply and fixing in repair shackle type porcelain, vitreous, white, brown or green insulator of size 75mm height, 90mm dia for working pressure 1100 volts including galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm complete all as specified and directed. Note:- The rate of galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm is included in this item and nothing shall be paid extra.

50

-

-

... More
Supply and fixing in repair loop type insulator, vitreous porcelain white, brown or green with over all dimension 65mm x 90 mm , clearance dia of bolt 16 mm complete all as specified and directed.

10

-

-

... More
Taking out old broken PCC Pole of any size , embeded with PCC foundation complete all as specified and directed.

20

-

-

... More
Supply and errecting Pre Stressed concrete Pole 9.00 Mtr long ,102mm x 172 mm at top ,102mm x 279 mm at bottom , class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of radiant paint over a coat of primer with black and white strips 30 cm wide each up to 1.5 mtr height from top of PCC foundation block and numbering of poles including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and directed. Note :- (i) The T & P / vehicles will be arranged by the contractor for transporting the pole if required and the cost deemed to be included in the quoted rates. (ii) The cost of excavation , returning filling and removal of earth work is included in this item and nothing shall be paid extra on this account.

20

-

-

... More
Material and Labour for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of poles etc, filling and mass concrete including necessary form work complete all as specified and directed.

10

-

-

... More
Material and Labour for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping, of poles/struts etc including necessary form work complete all as specified and directed.

0.62

-

-

... More
Supply and fix in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. Note : The rate of one primer coat, one under coat and one finishing coat of paint is included in this item.The payment shall be made as per actual weight of material. During weighting the weight of paint and primer shall not be considered for payment purpose.nothing shall be extra paid on this account.

2

-

-

... More
Supply and fix in repair stay assembly comprising of GI stay bow 14 mm dia, 40 cm long complete with accessories as shown in Electrical plate No 1 of SSR Part - I using galvanised stay rod 20 mm dia, 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick ,2 Nosf thimbles, MS clamps made out of 50mm x 6 mm flat iron, loop stay insulator, stay wire 7/8 SWG complete including painting all exposed surfaces of MS work including two coats of aluminium paint over a coat of red oxide zinc chromate primer complete all as specified and directed. Note : Loop type insulators, Earth work and concrete work shall be measured and paid for separately under the respective item of BOQ.

6

-

-

... More
Supply , fixing and stretching in repair ACSR of any size as per site requirement on existing HT/LT poles including binding on existing insulator with aluminium binding wire 2mm dia complete all as specified and directed by Engineer-in-charge. Note :- 1. For measurement and payment purpose only the weight of ACSR shall be considered .The weight of aluminium binding wire 2.00mm shall not be considered.2. The rate of aluminium binding wire 2.00mm is included in this item and nothing shall be paid extra on this account.(ii)(ii) New insulators if required shall be measured and paid seperately under respective item of this scheule of works of BOQ.

8

-

-

... More
Supply , fixing and Stretching in repair 4mm dia GI earth wire / guard cradles on existing HT / LT poles binding with and including GI binding wire 1.63 mm complete all as specified and directed. Note :- (i) For measurement and payment purpose only the weight of 4mm dia GI earth wire / guard cradles shall be considered .The weight of GI binding wire 1.63 mm shall not be considered. (ii) The rate of GI binding wire 1.63 mm is included in this item and nothing shall be paid extra on this account.

0.5

-

-

... More
Cleaning and preparation of old painted surface of LT PCC Street light Pole up to 1.50 mtr height from top of PCC foundation block, making alternative black and white strips on pole with Radiant paint ( each strip 30cm hight ) and writing pole nos. including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and directed.

20

-

-

... More
Supply and fixing PVC separator suitable for 3/4 way conductor complete all directed.

200

-

-

... More
Supply and fixing PVC separator suitable for 5/6 way conductor complete all directed.

200

-

-

... More
Supply and laying or fixing in repair GI tubing light grade 40 mm dia for cable protection including fitting complete with flat iron clamps size of flat iron 25mm x 4mm, nuts, bolts & washers fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench complete all as specified and directed.

50

-

-

... More
All as per serial item No. 40 above but for 50 mm bore GI tubing light grade.

50

-

-

... More
All as per serial item No. 40 above but for 80 mm bore GI tubing light grade.

20

-

-

... More
Demolitiong of old earth pit and Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32mm X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.

10

-

-

... More
Supply and fixing in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by using 25mm x 3mm aluminium strip complete all as specified and directed.

50

-

-

... More
Supply and fixing in repair MCCB, 3 phase, 4 pole, 415 volt of capacity 630 Amp, short circuit, shunt trip coil with contactor, breaking capacity not less than 35/36 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and directed.

5

-

-

... More
All as per serial item No. 45 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 400 Amp, breaking capacity not less than 35/36 KA.

10

-

-

... More
All as per serial item No. 45 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 250 Amp, breaking capacity not less than 25 KA.

15

-

-

... More
All as per serial item No. 45 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 200 Amp, breaking capacity not less than 25 KA.

15

-

-

... More
All as per serial item No. 45 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 100 Amp, breaking capacity not less than 25 KA.

15

-

-

... More
All as per serial item No. 45 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 63 Amp, breaking capacity not less than 25 KA.

15

-

-

... More
Supply and fixing in repair MCB suitable for 415 volts AC supply, 63 Amps, Four Pole 'C' series with over load and short circuit protection and rupturing capacity not less than 9/10 KA. complete all as specified and directed.

20

-

-

... More
Material and labour for making the hole under road and hard standing for laying and incluidng inserting Galvanised steel light grade pipe of 100 mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed. Note : The rate of Galvanised steel light grade pipe of 100 mm dia is included in this item and nothing shall be paid extra on this account.

36

-

-

... More
Cutting of road, demolition of cement concrete (un-reinforced) in ground floor and paving thickness not exc. 15 cm (below or above ground level) , taking out old LT under ground cable of any size any description and old pipe, relaying the taking out old servicable cable and pipe from this job or new cable and pipe in lieu of old unservicable cable and pipe,material and labour PCC (1:2:4) Type -B1 using 20mm graded crushed stone aggregates for making good and matching the existing surfaces complete all as specified and directed. Note : (i) New GI pipe if required for this item shall be measued and paid separately under appropriate items of schedule of works of BOQ. (ii) New cable if required for this item shall be measured and paid seprately in supply and fixing items under appropriate items of schedule of works of BOQ. (iii) The labour element rate of relaying of old servicable cable and pipe which is taking out from this job is included in this item and nothing shall be paid extra on lthis account. (iv) Cost of Taking out old unservicable cable and pipe is included in this item and nothing shall be paid extra on this account. (v) The cost of material and labour for providing PCC (1:2:4) Type -B1 using 20mm graded crushed stone aggregates for matching the existing surface is included in this item and nothing shall be paid extra on this account.

5

-

-

... More
Cutting /Cleaning away all grass,bushes,under growth small tree roots,hedges,vegetation, branches of trees etc at installation of electric supply up to entire satisfaction of Engineer -in-charge and disposing the same at a distance upto 50 mtr away from the prepherial area under clearence complete all as directed.

1800

-

-

... More
Taking down old unserviceable LT feeder pillar box of any discription and size including demolished PCC foundation and all accessories such as MCCB/Cubical type complete all as directed.

20

-

-

... More
Supply, fabricating, installation, testing, commissioning and electrically connecting LT feeder pillar box cubical type of size 60 cm x 40 cm x 30 cm, 415 Volts, factory made, machine pressed, dust and vernim proof, out door type, made with CRCA sheet 3.15 mm thick. Feeder pillar box shall be powder coated with seven tank process for treatment of degrasing, pickling and two coats primer before giving the stove epoxy finish, Front opening with single door with provision of rubber beading and locking system including 200 amp aluminium bus bar set of four and 01 No MCCB 63 Amp, 16 KA alongwith provision of hole on bus bar for fixing of cable mounted on PVC / epoxy insulators and mounted on angle iron legs frame made with angle iron of size 50 mm x 50 mm x 6 mm and legs duly spray painted both internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate including necessary earth work , including all provision of opening for incoming / outgoing cables and testing complete all as directed.

20

-

-

... More
Supply and fix in repair straight through joint (Epoxy) for LT under ground cable including jointing kits suitable for 3.5 core, 25 to 90 Sqmm aluminium conductor cable complete all as directed.

20

-

-

... More
All as per serial item No. 57 above but suitable for 3.5 core, 120 to 400 Sqmm aluminium conductor cable

20

-

-

... More
Supply and fix in repair cable route indicator fabricated from 40 x40 x6 mm angle iron 450 mm long riveted or welded with 100 mm dia MS round disc duly engraved 'LT CABLE' in letters in brown clour including PCC block of size 200 x 200 x 300 mm of (1:4:8) type D2 using 40 mm graded crushed stone aggregate complete all as directed.

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.