Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date4 Jan 2025
Closing Soon8 Feb 2025
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F VCB Closing coil, Suitable Coil Voltage of 110V DC, 24V DC, 30VDC of Suitable Make

5

-

-

... More
S&F VCB Tripping coil, Suitable Coil Voltage of 110V DC, 30V DC, 30VDC of Suitable Make

5

-

-

... More
S&F 11Kv Insulators With Minimium Creepage diffrence of 230 mm for L1,L2,L3 for 11KV VCB/OCB of Suitable Make.

15

-

-

... More
S&F Spouts Links of Incomming & outgoing Line of suitable make of VCB Make- Siemens, ABB & Any Make.

4

-

-

... More
S&F Three phase 11 kv /110/r3 50VA resin cast type PT with 3.15 amps fuse of Suitable Make

2

-

-

... More
S&F11 KV resin cast CT ratio - 100/50/5A for Metering Cl1.0 & Protection Class 5P10 of Suitable Make

3

-

-

... More
S&F 11 KV resin cast CT ratio - 200/100/5A for Metering Cl1.0 & Protection Class 5P10 of Suitable Make

3

-

-

... More
S&F 11 KV resin cast CT ratio - 400/200/5A for Metering Cl1.0 & Protection Class 5P10 of Suitable Make

3

-

-

... More
S&F Master trip relay (Coil voltage= 24, 30, 110 VDC) contact configuration 3 NO + 3 - NC (H/R) of Suitable Make

5

-

-

... More
S&F Three element voltage operated auxiliary relay (coil voltage = 24, 30, 110 VDC) Contacts : 2 NO / 2NC (H/R) for each elements of Suitable Make

5

-

-

... More
S&F Three phase digital ammeter (96 sqmm) - flush mounted (C1 : 0.5) Aux supply = 24,110, 230 VAC of suitable Make

14

-

-

... More
S&F Three phase digital voltmeter (96 sqmm) - flush mounted PT ratio : 11 KV /3 /110 V/R3 (C1 : 0.5) Aux supply = 24, 110, 230 VAC to measure line L-L voltage of Suitable Make

10

-

-

... More
S&F Digital MFM meter (Aux supply = 24, 110, 230 VAC, Size 96 mm x 96 mm ,C1 : 0.5 RS -485 port on modbus of Suitable Make

8

-

-

... More
S&F Breaker control switch TNC 25 AMP, 660 VAC having 1 TRIP & 1 CLOSE contact indicating plate size 75 x75 mm with marking TRIP-NEUTRAL CLOSE.

4

-

-

... More
S&F selector switch for local & remote 2 pole 2 way amp 10 amps colour gray volts-220V

4

-

-

... More
S&F Ammeter selector switch 3 way and off

8

-

-

... More
S&F Voltmeter selector switch (3 way and off) R-Y,Y-B,B-R off

8

-

-

... More
S&F Indication lamps 63.5, 110VAC and 24 VDC of different colours as per Site requirement of Reputed Make.

110

-

-

... More
S&F Base with fuse link -25 amps

8

-

-

... More
S&F MX0 22E type auxiliary contactor (2No+2NC) supply voltage = 24, 30, 110 VDC of Suitable Make.

6

-

-

... More
S&F Anti condentation space heater 100w With Protection Mesh 230vac Operated of Suitable complete with wiring as required at site Make.

6

-

-

... More
S&F 6" to 8" thermostate of 25-45 Deg C. Setting of Suitable Make.

8

-

-

... More
S&F spring charging of motor of 24, 110, 230 Vac/dc aux supply of Suitable Make for ABB/Siemens VCB.

2

-

-

... More
S&F Main Jaw contact Rated 800/1250A of VCB as per Make / Model at site.

3

-

-

... More
S&F 800A/1250A Rated Vaccuum interrupter for 11 KV VCB as per Make / Model at site.

6

-

-

... More
S&F VCB Charging Handle as per Make / Model at site.

2

-

-

... More
S&F limit switch for VCB.

6

-

-

... More
M&L in replacement of wiring of IDMT relay/CT/trip relay complete with 2.5 sqmm copper flexible conductor cable including their numbering and make system serviceable complete testing of IDMT relay complete all as specified and directed.

6

-

-

... More
Supplying ,fixing danger notice board of 1.6 mm thick mild steel sheet , viterous enamelled white , with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts for HT 25X20 cm size complete all as specified and directed.

6

-

-

... More
M & L for painting of OCB/VCB's from inside and outside by applying two coats of synthetic enamel paint (Smoke grey) after Disconnecting and removing then Scraping old paint and the Repainting, writing SM/MES No., Incoming and outgoing details complete all as specified and directed by Engr in charge

18

-

-

... More
M & L for calibration of earth fault relay and over load relay of the distribution panel with accuracy of OCB/VCB setting and testing the tripping system as directed by Engr-in-charge.

15

-

-

... More
S&F Temperature gauge circular dial type of standard size and dia suitable for transformer upto 6.3 MVA. Make - AE / ITE / Kirloskar

8

-

-

... More
Top gasket made of 3mm thick cork sheet with suitable holes for transformer including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity upto 6.3 MVA complete all as specified & directed.

4

-

-

... More
Top gasket made of 3mm thick cork sheet with suitable holes for transformer including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity above 200 KVA and upto 750 KVA complete all as specified & directed..

2

-

-

... More
S&F lightning arrestor expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, complete all as specified & directed.

2

-

-

... More
S&F cable jointing kit for 11 KV (earth) grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm, complete all as specified & directed.

8

-

-

... More
S&F cable jointing kit for 11 KV (earth) grade cable for outdoor termination heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm, complete all as specified & directed.

5

-

-

... More
S&F cable End jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 400 Sq mm, complete all as specified & directed.

6

-

-

... More
S&F cable end jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120-185 Sq mm , complete all as specified & directed.

5

-

-

... More
S&F cable straight through jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120-185 Sqmm , complete all as specified & directed.

5

-

-

... More
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge.

534.6

-

-

... More
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed by Engineer -in-charge.

446

-

-

... More
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed.

89

-

-

... More
Sand cushioning to the under ground electric cable complete all as specified considering 19.75 of SSR part -I

80.19

-

-

... More
Supply and laying un-reinforced pre cast concrete cable cover conforming to IS:5820 with minimum average breaking load capacity 300 kgs for unreinforced covers, class HV Type 1, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-Charge.

4590

-

-

... More
Repair to HT panel having vaccum circuit breaker 11 KV rating of capacity 250/350 MVA and current reting up to 800/1250 Amprs by replacing defective / wornout parts, with the same make & capacity adjusmenet of gaps for smooth operation all as detailed below :-lSwitch off complete HT/LT electric supply of sub station and Isolating the HT Vacuum Circuit Breaker 11 KV , 3 Phase , any capacity by disconnecting all incoming/outgoing HT cable carefully and checking the serviceability of UNSV VCB step wise such as primary insulation,scecondary insulation,complete wiring system,auxilary switches triping system,triping machanism,vaccum interupter , safety shutter, motor charging system/machanically charging spring,earthing system busbar,insulators current transformer , and other related spares such as over current and earth fault relays,meters and other control in the presence of AGE E/M complete includng cleaning of all spares properly, removing all dust and dirt particles UNSV spares parts shall be measured and paid for separately under relevent items and refixing the same after repair and testing on full load complete all as specified and directed by EIC.

20

-

-

... More
(a) Cleaning of VCB with air blower and removing dust particals. (b) Cleaning of insulating paces of VCb by using CTC/CRC/Thinner as required and recommended. (c) Checking the acring contract gap of vaccum intrupter if gap exceeds the permissible limis, reaad just as recommeded. (d) replacing the fixed and moving contract if the thickness of contacts is not proper. (e) cleaning the main contacts to remove carbon or some unwanted particls if sisbile. (f) dismentling and cleaning the insulated surfaces and arcbarrier with CTC and CRC. (g) checking/repair replacement of all electrical wiring for electrical/mannual operation including measuring IR values.

-

-

-

... More
(h) checking of all parts of cradles for proper alignment and grasing etc. (j) checking of all nuts/bolts, springs, levers \, latches connection etc and adjustment as required and recommended. (k) recording IR value of CT's, PTs. (l) cleaning of bus bar spout. (m) replacement of defective indicator lamps etc. (n) checking of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Make of VCB CG/ABB/Alstom, Ariva, Kirloskar. Note: service will be carried out through service engineer of manufacture employee. No employee of authorised dealer shall be hired for servicing of VCB. Grommets, dust cover ring of isolator contracts clips, pin for releases prop "Y" Phase shround, over ride stop pin etc. Note: Major spare parts shall be paid separately under repective item.

-

-

-

... More
Supply in replacement of resin encapsulated Vacuum bottles suitable for 11 KV VCB panel of cap 400 Amp 18 KA complete all as specified and directed by EIC.

4

-

-

... More
Repair of motorized gear charging system including repair of electric motor geared type .

6

-

-

... More
Supplying, installing, testing and commissioning constant voltage (CV ) battery bank ( Location at Main power house and old power house) for VCB panel with maintenance free batteries of 2 volts 70 Amps-12 Nos with battery stand and battery charger incl initial charging and complete wiring in conduits with HT panels.The charger have to alarm on fuse blowing and short circuit. all protection to charger and its meters shall be provided with rating MCB only.

2

-

-

... More
S&F tubing light grade' 80 mm bore galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/GI / bolts/nuts/washers or laid in floors/under roads complete including sealing material all as specified and directed of the following bores complete all as specified and directed .

60

-

-

... More
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 11000 Volts grade of size 3 core 95 Sqmm , complete all as specified and directed .

500

-

-

... More
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 11000 Volts grade of size 3 core 120 Sqmm , complete all as specified and directed .

350

-

-

... More
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 11000 Volts grade of size 3 core 185 Sqmm, complete all as specified and directed .

250

-

-

... More
M&L for Earthing complete with copper earth plate electrode 600x600x 3.15 mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.25 Mtr below normal ground level connected to the copper strip 20x3 mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 20x3 mm copper strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 191 Part-I all as specified and directed .

8

-

-

... More
(i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance below 10 ohms is not obtained the contrator shall redo the earthing without any extra cost to the department .

-

-

-

... More
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mm x 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted duly welded at joints to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead duly protected in and including 50 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 testing on completion all as specified and directed. Note: (i) If the desired earth resistance is not found within limit shall be redone by contractor at no extra cost. (ii) Cost of GI strip 32/6 mm and 40mm dia pipe medium grade upto 7.5 mtr shall be included in the rate quoted for this item

10

-

-

... More
M & L for switch air break gang operated triple pole out door type with drop out switch fuse unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (12 insulators) and frame with operating mechanism from ground level with earth switch and including locking arrangement complete all as directed.

8

-

-

... More
M&L for Trimming/ pruning of tree branches upto 3 meters below & both sides to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 meter from furthest conductor on pole including removing of cut branches and cleaning of site complete all as directed. Note - Gap between One Pole to another pole is considerd as one single span.

50

-

-

... More
M&L in replacement of earth pit indicator board made out of MS sheet 6mm thick of size 25cm x 15cm fixed on MS flat of size 40 x 6mm x 1.2mtr(long) by means of nut, bolt/ welding duly painted with two coats of synthetic enamel paint over a coat of red oxide paint of approved colour including writing the letters of size not exceeding 60mm all as directed by Engineer - in - charge. The indicator should indicate the following :- (i) Earth Pit No. (ii) Earth result in Ohms (iii) Date of testing Note :- (i) Cost of excavation of earth in any type of soil/ rock for erection of earth pit indicator board removal (upto the 50 Mtrs from starting point) and returning filling in of soil/ rock is deemed to be included in the quoted rates.

60

-

-

... More
M&L for earth testing, identifying the earthings in system and recording the results on indicator board and producing three copies of test sheet duly signed by Contractor/ JE/ AGE E/M all as directed by Eng-in-charge. Note :- (i) Cost of labour and tools required for testing is deemed to be included in quoted rates.

40

-

-

... More
M&L in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 ( metres long) all as specified and directed by Engr-in-charge.

16

-

-

... More
M&L PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) for foundation of poles / stays etc complete all as specified

6

-

-

... More
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping including necessary form work finishing the cement concrete surfaces even & smooth using extra cement complete all as specified.

3.5

-

-

... More
Supply errection and febrication of cross arms,bracings supports, clamp, and back plates febricated from structural steel section including nuts,bolts,washers welding,bending cold or hotdrilling holes for bolts in any shape or size as indicated or as directed by EIC

6

-

-

... More
M&L for Galvanised stay strand of size 7/4 mm staywire al as specified and directed by Engr-in charge.

2.5

-

-

... More
S&F in replacement for single pointed air termination aluminium rod 12mm dia 300 mm long including nuts & bolts for fixing air termination rod to pole/ pipe duly insulated by providing appropriate insulator all as required at site ,complete all as specified and directed by EIC.

80

-

-

... More
M&L test point terminal block made of steel plate of size 75x75x6 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex. head screw complete all as specified and directed by EIC.

77

-

-

... More
S&F in replacement for aluminum strip 25x3.15mm as roof conductor or down conductor or along the pole/pipe complete with saddles/ insulators made out of porcelain or fibere and fixing screws all as required at site or directed. Note :- Insulators should be approved quality & backlite fixing tightly so that it does not fall of during winds / rains.

2400

-

-

... More
S&F in replacement forGI strip 32x6mm, buried in ground or fixed to wall etc for loop earthing.

1500

-

-

... More
Supply and lay pipe galvanized, “Medium class”, including fittings 40 mm (1½”) dia for mounting air termination rod complete all as specified and directed.

100

-

-

... More
Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front and back door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.5 mtr long , 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 600 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators and one No. MCCB 400 AMP,50 KA, 4 Pole 415 V make Legrand, all as specified and direc ted by Engr-in-Charge.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.