Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Are you looking for raw materials?
Get raw material quotes and credit facility
Description
Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Repair And Replacement Of Central Ac Plant Ducts Cooling Coils Tower Air Handling Units Compartments Filters Chillers Tanks Indoor Grills Lt Panels And Other Allied Works Under Ge I Gos
Looking for Financing Options ?
Get easy access to Business and Personal loans
Contact
Tender Id
2025_MES_693262_1Tender No
8000/107/2024-25/1006/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in/
Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Item | Quantity | Units | Rate | Amount |
---|---|---|---|---|
User do not have access to view details | Invalid | Invalid |
... More
Taking down old unsv/burnt LT panels/Feede pillar of any capacity and supply, install, testing and commissinoning of LT panel board indoor type of size 2250 mm long X1800 mm width X 400 mm thickness(depth) (length and width and thickness of LT panel sizes if required for heigher & lower size as required and decided by Engr-in-charge) with single door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle and shall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 2 mm thick at outer sheet and 1.60 mm thick at internal compartments CRCA sheet and necessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should be connected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6 mm GI angle iron base frame of height 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4) type B1 with studs,bolts,nuts & washers as per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured should be followed by CPRI norms/certified. (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering.(i) Incoming:- (a) MCCB,4 pole,415 Volts,50Hz Manual drawout type with microprocessor release of capacity 400 to 500 Amps,35/36 KA,extended rotary handle, suitable rating factory made spider links,steel nuts,bolts and washers & complete all as speficied and directed.-01 Nos Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) Control Instruments RYB indication lamps 240 V with control fuses with base -03 Nos© Digital Volt & Ammeter 3 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,15VA,tape wounded with control wiring and safety fuses complete all as speficied and directed-03 Nos(ii) Outgoing:- (a) MCCB 125 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory made spreader links & steel nuts,bolts and washers of suitable apms rating - 01Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) 20 HP Soft Starter feeder X 01 No with MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver 4,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nos(iii) (a) MCCB 32-40 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating - 04 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) 10 HP Soft Starter feeder X 04 No with MPCB,3 pole,TMA release for OL &SC 11A to 16 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,11-16A ,7.5KW,Pluging relay,240Volts,AC,2C/O with base -16 Nos,RYB indication lamps 240Volts,AC-04 Set with flush head push button (Red-04Nos,Green-04 Nos,Black-04 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-04 Nos,Single phase preventer protection & Safety-04 Nos,Mushroom Head Emergency stop push button-04 No,Exhaust fan with louver 4,230V,AC-04 No, Digital Volt & Ammeter 1 Ph,Cl-1 (04 No) with suitable current rating CTs,CL-1,5VA,30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-04 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nos(iv) (a) MCCB 32 to 40 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating - 02Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) 5 HP Soft Starter feeder X 02 No with MPCB,3 pole,TMA release for OL &SC 6.3A to 16A Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,9 to 10A ,4KW,Pluging relay,240Volts,AC,2C/O with base -8 Nos,RYB indication lamps 240Volts,AC-02 Set with flush head push button (Red-02Nos,Green-02 Nos,Black-02 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-02 Nos,Mushroom Head Emergency stop push button-02 No,Exhaust fan with louver 4,230V,AC-02 No, Digital Volt & Ammeter 1 Ph,Cl-1 (02 No) with suitable current rating CTs,CL-1,5VA,30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-02 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-02 Nos(v) MCCB 100 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable amps rating - 4 Nos and including RYB indicator lamps,Digital volt& Ammeter with necessary CTs and selector switches-04 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(vi) MCCB 160 Amps,3 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable amps rating - 1 Nos and including RYB indicator lamps,Digital volt& Ammeter with necessary CTs and selector switches-01 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved
... More
Taking down old unsv/burnt LT panels/Feede pillar of any capacity and supply, install, testing and commissinoning of LT panel board outdoor type of size 3000 mm long X1000 mm width X 500 mm thickness(depth) (length and width and thickness of LT panel sizes if required for heigher & lower size as required and decided by Engr-in-charge) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle and shall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3 mm thick at outer sheet and 1.6 mm thick at internal compartments CRCA sheet and necessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should be connected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6 mm GI angle iron base frame of height 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4) type B1 with studs,bolts,nuts & washers as per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured should be followed by CPRI norms/certified. (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering.(i) Incoming:- (a) MCCB,4 pole,415 Volts,35/36 KA,50Hz Manual drawout type with microprocessor release of capacity 400 Amps,extended rotary handle, suitable rating spider links,steel nuts,bolts and washers & complete all as speficied and directed.-01 Nos Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) On-Load Change Over switch 400 Amps,4 pole,415 Volts,50Hz of capacity ,extended rotary handle, suitable rating spider links,steel nuts,bolts and washers & complete all as speficied and directed.-01 Nos Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(c) Control Instruments RYB indication lamps 240 V with control fuses with base -03 Nos(d ) Digital Volt & Ammeter 3 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,15VA,tape wounded with control wiring and safety fuses,Necessary busbar(RYB&N) complete all as speficied and directed-03 Nos(e) Necessary copper wire,1100volts of size 1.5 to 10 sqmm, heavy duty type of suitable ratings as per load for each control switch for incoming and outgoing controles.(ii) Outgoing:- (a) MCCB 40-100 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating for existing eqpts - 3 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells/L&T or equivalent as approved .(b) 40 HP Soft Starter feeder X 03 No , MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nosg - 03Nos - Make:-ABB/ Siemens/Schneider/Havells/Legrand/CG/L&T(c) MCCB 40-100 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating for existing eqpts - 3 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells/L&T or equivalent as approved .( d) 20 Soft Starter feeder X 03 No , MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nosg - 03Nos - Make:-ABB/ Siemens/Schneider/Havells/Legrand/CG/L&T(e) MCCB 40-100 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating for existing eqpts - 3 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells/L&T or equivalent as approved .(f) 7.5 to 10 HP Soft Starter feeder X 03 No , MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nosg - 03Nos - Make:-ABB/ Siemens/Schneider/Havells/Legrand/CG/L&T(g) MCCB 40-100 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating for existing eqpts - 3 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells/L&T or equivalent as approved .(h) 3 to 5.0HP Soft Starter feeder X 03 No , MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nosg - 03Nos - Make:-ABB/ Siemens/Schneider/Havells/Legrand/CG/L&T(iii) (a) MCCB 125-160 Amps,4 pole, 25KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating - 01 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved
... More
Supply, install, testing and commissinoning LT panel board outdoor type of size 1600 mm long X1600 mm width X 400 mm thickness(depth) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle and shall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, made out of 3.15 mm thick at outer sheet and 2.0 mm thick at internal compartments CRCA sheet and necessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should be connected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame of height 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4) type B1 with studs,bolts,nuts & washers as per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified. (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering.(iii) Name of LT Panel Manufacturers :- M/S UTKAL Electrical Idustries /M/S Girija Electricals or as approved and followed by CPRI norms/certified or equivalent approved manufacturers.(i) Incoming:-MCCB 630 Amps,4 pole, 50KA, 415 Volts thermal magnetic based-01 Nos incl spreader links of suitable ratings & size with suitable rating lugs,glands,nuts,bolts,washers etc as per site reqt. Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(ii) Outgoing:-MCCB 400 Amps,4 pole, 36KA, 415 Volts thermal magnetic based-01 Nos incl spreader links of suitable ratings & size with suitable rating lugs,glands,nuts,bolts,washers etc as per site reqt. Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(iii) MCCB 250 Amps,4 pole, 36KA, 415 Volts thermal magnetic based-03 Nos incl spreader links of suitable ratings & size with suitable rating lugs,glands,nuts,bolts,washers etc as per site reqt. Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(iv) MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-01 Nos incl spreader links of suitable ratings & size with suitable rating lugs,glands,nuts,bolts,washers etc as per site reqt.Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(v) MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-01 Nos incl spreader links of suitable ratings & size with suitable rating lugs,glands,nuts,bolts,washers etc as per site reqt. Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(vi) MCB 63 Amps,4 pole, 10KA, 415 Volts thermal magnetic based-01 Nos incl spreader links of suitable ratings & size with suitable rating lugs,glands,nuts,bolts,washers etc as per site reqt. Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(vii) R,Y,B Phase indicating lamp -01 Set Make:- Jigo/L&T(viii) Digital Ammeter (0 amps to 500 Amps) selector switch -01 No.Make:-AE/Selec(ix) Ammeter Selector switch -01 No.Make:-AE/Kaycee(x) 800/10A/5A current transformer -03 No's Make:-Kappa(xi) Digital Voltmeter( 0Volts to 500Volts)-01 No with ASS, Make:-AE/Kaycee (xii) Volmeter selector switch -01 No with VSS Make:-AE /Kaycee(xiii) Protection fuses& controll wiring -03 Nos Make:-Nippon (xiv) Busbar aluminium TPN 800 amps rating suitable size -01 Set ( 04 Nos)
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
Unlock the Tender details for free
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%