Indian Oil Corporation Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Indian Oil Corporation Limited - IOCL Tender
Eprocure
Opening Date14 Jun 2021
Closing Date16 Jul 2021
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Supply And Augmentation Of Control And Safety System
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_REFHQ_136720_1Bid Award Id
ViewTender No
TP/080557C001/205/1511-001/51Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://iocl.com
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special_Instructions_to_the_Bidders_20200717
Terms and Conditions for Erection and Commissioning
BOQ Items
DCS, ESD, GDS & FDAS System (ICSS) (MCR) SRR - 819 – Additional tank Alkylate, MS and PCK: As per supply requisition which includes as a minimum:
- Supply of all hardware and Software, required for the ICSS modification Job in (MCR) SRR-819 including corrosion monitor for new extension of (MCR) SRR-819.
- FAT (Factory Acceptance Test)
- Installation, Integration of hardware/software with DCS and to establish data communication system ESD/GDS/FDAS system
- Required Software for new installation (if any).
- Complete engineering which includes submission of datasheet/drawing / documentation and O&M Manuals.
- Upgradation of Software license if any, additional SCADA points if any, augmentation of work stations / servers storage capacity, if any
- Power on pre-SAT and SAT
- Mandatory spares as per annexure 1
- Pre-commissioning /Commissioning /Start-up activities (Spares as per System vendor recommendation)
- Warranty of the supplied items
-Third party inspection
-Communication system between control system and other system & 3rd party interfaces
-Set of special Tools for installation, testing and Commissioning
-Set of spare parts for pre-commissioning / start-up as per Vendor Recommendation
-Documentation including certification purpose & 1 Lot customs clearance
-Packing and Marking
-Freight Charges
1
-
-
DCS, ESD interface with SS-312N – Additional Tank: As per supply requisition which includes as a minimum:
- Supply of all hardware and Software, required for the E&I interface for ICSS modification Job pertaining to additional tanks in north of creek
- FAT (Factory Acceptance Test)
- Integration of hardware/software with DCS system and to establish communication system between IRP and DCS/ESD in SRR801 & SRR-819.- Required Software for new installation (if any).
- Complete engineering which includes submission of datasheet/drawing / documentation and O&M Manuals.
- Upgradation of Software license if any, additional SCADA points if any, augmentation of work stations / servers storage capacity, if any
- Power on pre-SAT and SAT
- Mandatory spares as per annexure 1
- Pre-commissioning /Commissioning /Start-up activities (Spares as per System vendor recommendation)
- Warranty of the supplied items
-Third party inspection
-Communication system between control system and other system & 3rd party interfaces
-Set of special Tools for installation, testing and Commissioning
-Set of spare parts for pre-commissioning / start-up as per Vendor Recommendation
-Documentation including certification purpose & 1 Lot customs clearance
-Packing and Marking
-Freight Charges
1
-
-
FDAS System (ICSS) modification in Fire station FS- 407 & -408: As per supply requisition which includes as a minimum :
- Supply and installation of all hardware and Software, required for the modification Job in FS-407.
- Interface and integration of Fire and gas signals, New BFAP(if any) including augmentation in new or existing Hard wired console, graphics console, mimic panel etc., at fire station FS-407
- Interface and integration of Fire and gas signals including augmentation of existing graphics console etc., at fire station FS-408
- FAT (Factory Acceptance Test)
- Installation, Integration of hardware/software, establish data communication system DCS, FDAS and GDS
- Required Software for new installation (if any).
- Complete engineering which includes submission of datasheet/drawing / documentation and O&M Manuals.
- Upgradation of Software license if any, additional SCADA points if any, augmentation of work stations / servers storage capacity, if any
- Power on pre-SAT and SAT
- Mandatory spares as per annexure 1
- Pre-commissioning /Commissioning /Start-up activities (Spares as per System vendor recommendation)
- Warranty of the supplied items
-Third party inspection
-Communication system between control system and other system & 3rd party interfaces
-Set of special Tools for installation, testing and Commissioning
-Set of spare parts for pre-commissioning / start-up as per Vendor Recommendation
-Documentation including certification purpose & 1 Lot customs clearance
-Packing and Marking
-Freight Charges
1
-
-
Supervision of Post Commissioning (Refer Note: 5 above) Per diem charges for upto 8 hours work on normal working days
1
-
-
Supervision of Post Commissioning (Refer Note: 6 above)
Overtime rate/hour beyond normal 8 Hours work on normal working days
1
-
-
Supervision of Post Commissioning (Refer Note: 6 above)
Overtime rate/hour for work on weekly off days / Holidays (as applicable to project site)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements