Military Engineer Services Tender
View complete overview of Mizoram MES Tender
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666181_1Tender No
8877/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
7
-
-
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed
5
-
-
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
2
-
-
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces complete all as specified and as directed
2
-
-
Dismantling asbestos cement (corrugated/semi corrugated) in roof coverings, etc including ridges, claddings, etc. and disposing off including all necessary staging / scaffolding, etc. as required complete all as specified and as directed
40
-
-
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and as directed
3.2
-
-
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
2.5
-
-
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
85
-
-
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed
44
-
-
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
30
-
-
M&L for mild steel TMT bars grade Fe-500D, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
400
-
-
M&L for mild steel TMT bars grade Fe-500D, 8mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
230
-
-
M&L for mild steel TMT bars grade Fe-500D, 5mm dia and over upto 10mm dia, as in stirrups, spacers, etc. cut to length, bent to shape required including cranking, bending spirally for hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
200
-
-
S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-240 complete all as specified and as directed
1800
-
-
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 11 to 15mm complete all as specified and as directed
128
-
-
Supply only mild steel conforming to Fe-410W grade E-250 quality-A, round bars 10mm dia, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in tie rods to chain link fencing complete all as specified and as directed
752
-
-
S&F rolled mild steel angle iron posts & struts in fencing including cutting top to shape, drilling holes, notching for wire, flat iron fillets (for securing wire mesh) including all necessary drilling bolts or rivetting & similar works of Fe-410-0 or Fe-310-0 grade E-165for securing chain link fencing, etc. complete all as specified and as directed
3000
-
-
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed
90
-
-
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed
27
-
-
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 200mm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 50mm but n exceeding 100mm wide complete all as specified and as directed
135
-
-
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles, mass concrete, etc. complete all as specified and as directed
3
-
-
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in columns, posts, piers, pillars, struts, etc. complete all as specified and as directed
1.3
-
-
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in beams, cantilevers, lintels, etc. over 1.5m long complete all as specified and as directed
1
-
-
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling, sub-bases, mass concrete, etc. complete all as specified and as directed
7
-
-
M&L for plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in benching, railings, etc. incuding weathering, slightly rounded or chamfered angle, throating and all necessary formwork complete all as specified and as directed
0.12
-
-
M&L for pre-cast plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in plain faced covers, etc. including all mouldings, formwork, etc. set in CM 1:6 complete all as specified and as directed
0.4
-
-
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping, benching, rounded or chamfered at edges including all necessary formwork complete all as specified and as directed
0.2
-
-
M&L for plain cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregates) as in foundation filling, sub-bases, mass concrete, etc. complete all as specified and as directed
5
-
-
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in bed blocks, back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed
16
-
-
M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in floors, sub-bases, pavings, etc. surface finished rough complete all as specified and as directed
40
-
-
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate for bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm dia drain pipes complete all as specified and as directed
40
-
-
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed
Note: Inner girth shall only be measured
3
-
-
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
460
-
-
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
26
-
-
S&F 2 way sliding anodized aluminium glazed ventilator shutter with frame consists of following specification complete all as specified and as directed
(a) Ventilator frame 2 track of size 60x25x1.5mm thick
(b) Stiles and rails of size 35x25x1.5mm
(c) 35x35x1.5mm T section mullion
(d) PVC gasket with 4mm thick tinted glass, including aluminium handles with necessary locking arrangement
Notes: (a) Area of opening shall only be considered for meaurement purposes (b) All necessary accessories including tinted glass, PLPB, fittings, fixtures for assembling / fixing as per drawing complete shall be included in the quoted rate
1.5
-
-
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
160
-
-
Supply only chain link MS galvanised fencing, any size or type complete all as specified and as directed
Note: Weight of chain link shall be ascertained by a BOO ordered by the GE
1800
-
-
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provisioning of binding wire complete all as specified and as directed
840
-
-
S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and including provision of galvanised mild steel wire, staples or steel pins, etc. including all necessary T&P, safety measures, staging, scaffolding, etc. to work at heights over security walls, etc. complete all as specified and as directed
Note: Weight of barbed wire shall be ascertained by a BOO ordered by the GE
15
-
-
Supply, laying in position, installation in true alignment, factory fabricated LLDPE readymade septic tank designed and suitable for 30 users, with up-flow filter effluent treatment including media with vent shaft and sludge chambers, all necessary excavation and earthwork in any type of soil, istallation and connecting up as per manufacturer's istructions complete all as specified and as directed
2
-
-
M&L for construction of soakage wells of size 3x4.5m suitable for 30 users, interception and screen chambers with PCC 1:3:6 type C2 (using 40mm graded stone aggregates) base foundation, brick honeycomb masonry walls in CM, RCC cover slab, including all necessary excavation and earthwork in any type of soil complete all as shown on drawings, all as specified and as directed
2
-
-
Supply and laying reinforced concrete pipes, 200mm bore, class NP2, laid in trenches, jointed in cement mortar 1:1 with collars and rubber ring joints and making necessary connection and testing complete all as specified and as directed
50
-
-
S&F 75mm dia PVC (SWR) 'P' floor trap with chromium plated grating jointed with solvent cement complete all as specified and as directed
4
-
-
Evaluation Notes How It Works ?