Closing Date7 Nov 2024
Tender Amount₹ 2,75,00,000
Costs
EMD
₹ 3,50,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667789_2Bid Award Id
ViewTender No
88968/A/SHL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents.
1
-
788951.12
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY)
Details of pre-priced Schedule is given in tender documents.
1
-
162770.54
SCHEDULE "A" PART-V (ROAD/ PATH/CULVERT)
Details of pre-priced Schedule is given in tender documents.
1
-
979487.7
SCHEDULE "A" PART-VI (AREA DRAINAGE)
Details of pre-priced Schedule is given in tender documents.
1
-
538790.24
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL)
Details of pre-priced Schedule is given in tender documents.
1
-
175709.27
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY)
Details of pre-priced Schedule is given in tender documents
1
-
106187.51
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION)
Details of pre-priced Schedule is given in tender documents
1
-
290379.73
SCHEDULE "A" PART-X (RETAINING WALL)
Details of pre-priced Schedule is given in tender documents
1
-
259826.91
SCHEDULE "A" PART-XI (FENCING AND GATE)
Details of pre-priced Schedule is given in tender documents
1
-
529739.5
SCHEDULE "A" PART -XII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
-
-
-
S&F 150mm size chromium plated shower roses with arm of minimum length 300mm , with or without swivel joints, including fixing to steel pipe or union, complete, all as specified and as directed.
8
-
-
S&F 15mm bore fancy type chromium plated angle cock , screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
16
-
-
S & F modular metal flush box with modular white cover plate with frame, 8 module complete all as specified and directed .
16
-
-
S & F modular metal flush box with modular white cover plate with frame, 6 module complete all as specified and directed .
12
-
-
S & F modular metal flush box with modular white cover plate with frame, 3 module complete all as specified and directed .
98
-
-
S & F modular metal flush box with modular white cover plate with frame, 1 module complete all as specified and directed .
8
-
-
S & F LED lamp 10 watt fixed to holder complete all as specified and directed.
10
-
-
S & F LED lights fitting, 4 feet, 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
92
-
-
S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
14
-
-
S & F LED security /street light fitting of capacity 35 watt with integral reflector made of aluminium alloy LM6 with LED driver, lamp, surge protector and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5 meter long bend to shape of dia 40mm GI medium grade pipe with MS clamp /nut & bolts/washers etc complete all as specified and directed.
16
-
-
S & F LED lights fitting, 1x 9W/10W, bulkhead luminaires, 220V, AC LED light with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
4
-
-
S & F LED wall bracket decorative light fittings,1x 9W/10W, polycarbonate body including LED light with driver, holder and LED Bulb of B22 base and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
16
-
-
S&F modular type MCB protected 20 Amp socket combination including metal flush box and cover plate having 3 Pin 20 Amps socket and plug combination complete with one single pole MCB SP 20 Amp 'C' curve fixed flush to wall complete all as specified and directed
24
-
-
S&F exhaust fan metallic steel body, single phase, 230 volts, 50 Hzs of size 300mm sweep, 900/950 RPM, heavy duty type with suitable metallic louver, blades, frame and flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete including making of hole in wall and making good to the disturbed surface complete all as specified and as directed.
2
-
-
S&F exhaust fan sturdy plastic body, single phase, 230 volts, 50 Hzs of size 300mm sweep, 1200 RPM, heavy duty type with suitable plastic louver, blades, frame and flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete including making of hole in wall and making good to the disturbed surface complete all as specified and as directed.
12
-
-
S&F concealed MCCB distribution box, double door, vertical type, TPN, 415V, 6 way, IP 43 suitable for MCCB of 100 Amps, 4P, 16 kA as incomer and MCB SP/TP as out going complete with suitable bus bar, neutral link, earth link complete all as specified and directed.
Note : (i) MCCB/MCBs shall be measured and paid separately
(ii) Blank space shall be covered with blank plates and cost for the same shall be deemed to be included in the quoted rate.
2
-
-
S & F Coaxial cable TV socket modular type 1/2 module complete all as specified and directed.
20
-
-
S & F Telephone socket (RJ11) shuttered modular type 1/2 module complete all as directed and as specified
8
-
-
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
200
-
-
Supplying and drawing Two pair 0.4 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
80
-
-
S&F electric water heater storage type steel body with stainless steel inner tank and heating element upto 1.5/2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, including PVC connection pipe for hot/ cold water to existing water lines,necessary fixing arrangement by using 50 X 5 mm MS plate and writing MES No and paste the instruction sheet of Do’s and DO NOT complete all as specified and as directed.
12
-
-
Supply, testing, installation, commissioning of Kitchen Exhaust system (Chimney), filter less and dry heat clean technology, thermostatic touch control panel with 3 spped gesture motion, including matt black finish, black metal oil collector, motor with copper winding, black glass clad hood with LED insignia, front panel with black glass, energy saving LED light, metal blower + metal Housing, designed air flow (Max)- 1250 Nm3/h, Noice level- 58 dBA (max), 5 years warranty, size -90 CM complete including fixing to wall, including fixing of duct and complete electrical wiring upto socket point as required for the chimney running complete all as specified and as directed.
2
-
-
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (light grade), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately.
(b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c) Excavation/earthwork is deemed to be included in the quoted rate.]
7
-
-
S & F Smart RF/Cellelur/Hybrid (RF + Celluler) Three phase AC Meter Temper Proof, static meter of class 1.00, 415 V, 50 Hz, 10A-60A as per IS -16444 and relevant IEC standards with inbuilt Radio Frequency communication facility with self healing mesh network with default and no demand display, billing data generation facility, anti-temper features, Microprocessor and LED/LCD based circuitary including SMC meter box of minimum size 250 x 250 x 155mm or as suitable for 3 phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and as directed. Meter shall support sending the following data :- (i) 15/30 min instantaneous data for volgtage, current, power, cumulative energy and frequency, monthly billing survey for cumulative energy and max demand to software meter shall have connected/disconnected functionally operateable from mdm/billing software and prepaid features shall be MDM/Billing end as per previous IS.
2
-
-
Construction of brick masonry valve pit with sub class ‘B’ brick in CM (1:4) of internal dimension 45cm x 45cm x 45cm depth with one brick wall thick over 10cm thick PCC in foundation with PCC (1:4:8) type D2 using 40mm graded aggregate, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bedding and coping including 15mm thick rendering with CM (1:4) complete, 3.15 mm thick MS sheet cover with angle iron framing of size 40mm x 40mm x 6 mm with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on external and internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil complete all as specified and as directed.
1
-
-
Supply, Installation, Testing and Commissioning of Fedder Piller box outdoor type of size 1000x900x600mm, totally enclosed, cubical type, front openable, single door, made out of 3.15 mm thick CRCA sheet on MS angle 50x50x6mm frame welded to the bottom, powder coated finished over a coat of red oxide primer,including provision of 04 Nos aluminium bus bar strip of rating 400 Amps (covered with insulated PVC sheets ) fixed on PVC insulators and internal connections with reuired rating of copper cable and terminals grouting on PCC foundations as per site required, and to accommodate following components. The Busbar Chamber shall be dust and vermin proof, IP 65 class protection with aprons for cable entry, with locking arrangement including provision of 65mm Godrej (Freedom) lock with 2 keys. The scope of work includes the following:-
(a) Incoming: MCCB 125 Amps 36 kA - 03 Nos. (b.) Outgoing: MCCB 63 Amps 16 kA-03 Nos (c) Timer switch with 3 Pole contactur and 40 Amp 4P MCB -01 Set (d) phase indication lamps ( R, Y , B ) - 1 set (e) Ammeter (incl CT) with selector switch -01 Set (f) Voltmeter (incl CT) with selector switch -01 Nos
NOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.
(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
1
-
-
Supply and Laying sub class "B" bricks laid in trenches for protection of UG cable with width equal to length of bricks, laid dry & flat complete all as specified and as directed.
3.96
-
-
S & F bracket for street light fittings, mounting bracket fabricated out of GI tubing 50 mm bore light grade not less than 1.2m long made to shape including 2 Nos flat iron clamp 50x6mm tightened with nuts, bolts & washers of suitable size mounted on pole/wall including two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
16
-
-
M & L Halogen free weather proof IP 65/66 cable junction box of size 200x 160 x 98mm for outdoor installations with terminal set of 10 sqmm 4 pole 01 mounting bracket and polyamide cable gland with lock nut (Type KF-5255) and making provision of an MCB SPN including terminal connection by proper sizes copper/aluminium lugs/thimble complete all as directed and as specified
15
-
-
S & F Post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with driver, lamp bracket with impact and corrosion resistant complete all as directed and as specified
10
-
-
M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 2.5 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 2.5 Sqmm connected to common earth dolly and drawing into rigid PVC conduit of required size medium grade size, making good the disturbed surfaces complete all as specified and as directed.
Note : Two run of submain wiring cable alongwith one run of earth wire including PVC conduit shall be measured as one length.
120
-
-
M & L Earthing complete with Galvanized steel earth plate electrode 600 mm x 600mm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
[Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately.
(b) Excavation/earthwork is deemed to be included in the quoted rate.]