Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687226_1Tender No
8832/UMR/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F Pre- painted galvalume aluminum zinc coating PPGL based corrugated/Trapezoidal steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
650
-
-
... More
S&F Pre- painted galvalume aluminum zinc coating PPGL based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall eave board , fixed with self tapping screws, complete all as specified and directed.
210
-
-
... More
Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof.
b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course).
d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs.
e) Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm.
f) The whole system shall be left for air cure for min Seven days (without any movement).
Make : - Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof or as equivalent approved by GE.
Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution.
(ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
1468
-
-
... More
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removal of debries to a distance not exc 50m as directed by Engineer in charge and making site clean complete all as specified and directed, complete all as specified and directed.
30
-
-
... More
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
40
-
-
... More
M & L PCC 1:4:8 type D - 2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate).
30
-
-
... More
Material and labour for Pre-cast cement concrete block masonry with solid blocks of type C1 (1:3:6), exc. 10 cm in width and setting in mortar, complete complete all as specified and directed by Engr-in-charge.
32
-
-
... More
M & L PCC 1:2:4 type B - 1 ( using 20 mm graded crushed stone aggregate) as in coping , benching incl necessary formwork, weathering, slightly rounded or chamfered angles as directed.
6.5
-
-
... More
M&L for 10mm thick plaster in cm (1:4) on fair faces/other than fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed
275
-
-
... More
E&M PORTION (INTERNAL ELATRIFICATION)
S&F Recess/surface mounting light 2'x2' luminaire,cool day light of 36w suitable for armstrong/Grid ceiling includingTaking down of old unserviceable fitting all as specified and as directed.
Make- Crompton/Havells/HPL/Bajaj or equivalent make specified in CA.
25
-
-
... More
Supply and fixing LED fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with flexible cable from ceiling rose to light fitting, complete all as specified and directed.
Make: Crompton/Helonix/Bajaj/Havells/HPL or equivalent make specified in CA.
165
-
-
... More
S&F for 32 mm dia GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old unsv / fully rusted existing unsv one complete all as specified and directed.
Make:Nezone/Surya/Jindal poles
15
-
-
... More
Supply and fix in repair of LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection of capacity 20W/25W. Make- Crompton/Havells/HPL/Bajaj or equivalent make specified in CA.
15
-
-
... More
S&F in Replacement of existing sub main wiring with three run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 1.5 Sqmm drawing into and including PVC casing and caping of adequate size with proper colour coding and making electric connections , including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through casing caping (ii) Three run of 1.5 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of PVC casing caping of suitable size will be measured as a one unit.
150
-
-
... More
S&F in Replacement of existing sub main wiring with three run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.0 Sqmm drawing into and including PVC casing and caping of adequate size with proper colour coding and making electric connections , including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through casing caping (ii) Three run of 4.00 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of PVC casing caping of suitable size will be measured as a one unit.
90
-
-
... More
E&M PORTION (EXTERNAL ELATRIFICATION)
Supply and fixing all in one comprising of high efficiency LEDs (120 lm/W), solar street Light with luminaire wattage 24/25W, High Efficiency Mono Crystalline Solar PV Module 12V 50W, lithium Ferro phosphate battery 12.8V 24Ah with inbuilt BMS technology, high efficiency LED 93%, MPPT solar charge controller and aluminium extruded body, specially designed intelligent microwave sensor to control the dimming nad brightness of light leads to extend working time and 5 mtr long octagonal pole (type CPT-5030) top dia 70 mm bottom dia 130 mm sheet thickness 3 mm including base plate of size (L x B x T) 200 x 200 x 12 mm, bolt size 4 x 16 mm dia and bolt length 450 mm, including taking down old unserviceable solar light of any capacity. Make: Crompton Cat No CSADSMP25CDL-NC, Havells enviro SSSSLX0141 or its equivalent in Philips/Bajaj
12
-
-
... More
M&L Steel Tubular swaged pole complete with cast iron base plate , final taper , bolts , nuts and screws etc as specified for type 410-SP-31 (9.00 mtr long) including painting with two coats of aluminium paint over one coat of red oxide primer including earth work,PCC and Coping of the pole all as specified and as directed
2
-
-
... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth strip 32x6mm size by means of bolls, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI light grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) reinforced and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150mm thick all around each plate wire mesh and earth work in any type of soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate -3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
8
-
-
... More
S&L in repair of UG cable XLPE insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area incl taking down of size 06 Sqmm 2 core complete all as directed.
176
-
-
... More
E&M PORTION (MISCELLANEOUS)
Supply and fixing LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 10 kV of capacity 45W incliding taking down old light all as specified and as directed. Make:Crompton, Havells,Phillips
50
-
-
... More
E&M PORTION (EXTERNAL WATER SUPPLY)
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of CI/GI/DI/PPR pipe and getting out in any type of soil, complete all as specified and directed by Engr-in-charge.
55
-
-
... More
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
5
-
-
... More
Returning filling in and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engr-in-charge.
50
-
-
... More
Taking up old U/S CI water mains (including all fittings) of size 250mm bore. with spigot socket and socket ends,tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead, complete all as specified and directed by Engr-in-charge.
22
-
-
... More
Taking up old U/S CI water mains (including all fittings) of size 150mm bore. with spigot socket and socket ends,tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead, complete all as specified and directed by Engr-in-charge.
33
-
-
... More
Taking up old U/S CI water mains (including all fittings) of size 100mm bore. with spigot socket and socket ends,tail pieces, sluice valves and lead joints etc. including burning out joints and recovering lead, complete all as specified and directed by Engr-in-charge.
33
-
-
... More
Supplying, Laying, Jointing and testing ductile iron pipe, K- 7 type with spigot and socket ends of size 250 mm dia laid in treanches including Rubber gasket (tyton ring) jointing materials etc complete all as specified and directed. Note : DI fittings, excavation and PCC to measued and paid seprately, complete all as specified and directed by Engr-in-charge.
22
-
-
... More
Supplying, Laying, Jointing and testing ductile iron pipe , K- 7 type with spigot and socket ends of size 150 mm dia laid in treanches including Rubber gasket (tyton ring) jointing materials etc complete all as specified and directed. Note : DI fittings, excavation and PCC to measued and paid seprately, complete all as specified and directed by Engr-in-charge.
33
-
-
... More
Supplying, Laying, Jointing and testing ductile iron pipe , K- 7 type with spigot and socket ends of size 100 mm dia laid in treanches including Rubber gasket (tyton ring) jointing materials etc complete all as specified and directed. Note : DI fittings, excavation and PCC to measued and paid seprately, complete all as specified and directed by Engr-in-charge.
33
-
-
... More
Supply and fixing in repair ductile iron fittings for socketed spigot, Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs any shape, of size up to 150mm bore, complete all as directed. Note: (Run Lead Joints shall be measured and paid separately, complete all as specified and directed by Engr-in-charge.
60
-
-
... More
Supply and fixing in repair ductile iron fittings for socketed spigot, Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs any shape, of size 200mm to 300mm bore, complete all as directed. Note: (Run Lead Joints shall be measured and paid separately, complete all as specified and directed by Engr-in-charge.
60
-
-
... More
Supply and fix in repair ductile iron sluice valve flange type of 200 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gaseket (neouprene), complete all as specified and directed by Engr-in-charge.
3
-
-
... More
Supply and fix in repair ductile iron sluice valve flange type of 150 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gaseket (neouprene), complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Supply and fix in repair ductile iron sluice valve flange type of 100 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gaseket (neouprene), complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Supply and fix in repair ductile iron sluice valve flange type of 80 mm dia PN 1.6 grade with stainless steel spindle & brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gaseket (neouprene), complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Supply and fix in repair DI Non return valve of size 200 mm and Taking out old unserviceable NRV ISI marked including complete fitting item with jointing materials such as nuts, bolts, washers and rubber gasket etc of suitable size, complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Material and labour for run lead joints for CI/DI pipe (water main) and fittings for 250mm bore spigot and socket pipes, complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Material and labour for run lead joints for CI/DI pipe (water main) and fittings for 200mm bore spigot and socket pipes, complete all as specified and directed by Engr-in-charge.
2
-
-
... More
Material and labour for run lead joints for CI/DI pipe (water main) and fittings for 150mm bore spigot and socket pipes, complete all as specified and directed by Engr-in-charge.
2
-
-
... More
Material and labour for run lead joints for CI/DI pipe (water main) and fittings for 100mm bore spigot and socket pipes, complete all as specified and directed by Engr-in-charge.
2
-
-
... More
Material and labour for Cutting cast iron pipes of size 200/150mm bore and reducing to required length before laying in position for insertion of new tees, branches, etc for taking branches connection, complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Material and labour for Cutting cast iron pipes of size 100/80 mm bore and reducing to required length before laying in position for insertion of new tees, branches, etcor taking branches connection, complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Demolition of cement concrete (Unreinforceed) of any description in ground floor n exc 15cm thickness (Below or above ground level), complete all as specified and directed.
2
-
-
... More
Material and labour for 100 mm PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate as in path , concrete surface even and smooth without using extra cement
30
-
-
... More
Material and labour for Cement concrete 1:3:6 Type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-charge.
2
-
-
... More
E&M PORTION (REFRIGERATION & AIR CONDITIONING)
Repair and maintenece of refrigerator capacities 230 ltr to 310 ltrs of existing make, carrying out the inspection carefully of the all units of refrigerator thouroghly, trace out the faults, and the repair the same in original position or MES yard/ work whop etc. by diconnecting and dismantling the defective units, gas filling, remove the gas leakage replacement of unserviceable spare parts, existing serviceable parts by cleaning etc. and reconnecting, reassembling the same after repair complete all as directed by Engr-in-Charge. Note : (i) The Spares parts and jointing material required for the repair after opening the refrigerator shall be done in the presence of JE/ Engr-incharge and the same will measured and paid seperately. as supply only under relevent item of BOQ. (ii) The fixing of existing serviceable parts shall be included in quoted rates. without claiming any extra cost. (iii) All the T&P items, transportation, welding stick, capilllary tubes NRV etc. shall be arrange by the contractor without claiming any extra cost.
3
-
-
... More
Material and labour for Gas filling R134a /600a charging with nytrogen testing by charging hose matching with existing size and make of refrigerator complete all as directed.
3
-
-
... More
Material and labour for filling of R134 compressor oil charging suitable hose matching with existing size and make of refrigerator complete all as directed.
2
-
-
... More
Supply & Fix in repair Freezer chamber matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Cool condenser matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Fan motor, with Fan blade matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Heater for defrosting purposes, matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair FF timer 3+1 matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Biometal, fuse matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Inverter PCB/ PCB timer matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Relay set, PCTR, matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Capacitor 3.5, 5 or 6 MFD matching with existing size and make of refrigerator complete all as directed
1
-
-
... More
Supply & Fix in repair Door switch matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Freeze compressor inverter model matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Fridge light and light holder matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair for Drier strainer suitable for matching with existing refrigerators complete including taking out all as directed.
1
-
-
... More
Supply & Fix in repair Thermostat matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Vegetable trayes with cover plate with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair partition iron meshes matching with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Drain water sink tray with tube as existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair Freezer Evaporator door with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Supply & Fix in repair heat condenser with existing size and make of refrigerator complete all as directed.
1
-
-
... More
Repair and maintenece of Deep Freezers of capacity 280/310/320 lts existing make, carrying out the inspection carefully of the all units of deep freezers thouroghly, trace out the faults, and the repair the same in original position or MES yard/ work whop etc. by diconnecting and dismantling the defective units, gas filling, replacement of new spare parts, existing serviceable parts etc. and reconnecting, reassembling the same after repair complete all as directed by Engr-in-Charge. Note : Note: (i) The Spares parts required for the repair after opening the deep freezer shall be carried out in the presence of JE /Engr-incharge and the same will measured and paid seperately as supply only under relevent item of BOQ. (ii) The fixing of existing serviceable parts shall be included in quoted rates. without claiming any extra cost. (iii) All the T&P items, transportation, capillary tube, welding stick, antichoking NRV jointing material etc. shall be arrange by the contractor without claiming any extra cost.
1
-
-
... More
Material and labour for Gas filling R134a charging with nytrogen testing by charging hose suitable for matching with existing size and make of refrigerator complete all as directed.
2
-
-
... More
Supply & Fix in repair Fan motor, with Fan blade 220-240 volt, 0.10 amp suitable for matching with existing size and make of deep freezer complete all as directed.
2
-
-
... More
Supply & Fix in repair Heater for defrosting purposes, suitable for matching with existing size and make of deep freezers complete all as directed.
1
-
-
... More
Supply & Fix in repair FF timer, suitable for matching with existing size and make of deep freezers complete all as directed.
1
-
-
... More
Supply & Fix in repair Inverter PCB/PCB timer suitable for matching with existing size and make of deep freezers complete all as directed.
2
-
-
... More
Supply & Fix in repair Compressor hermetically sealed suitable for matching with existing size and make of deep freezers complete all as directed.
2
-
-
... More
Supply & Fix in repair Capacitor 3.5, 5 or 6 MFD suitable, matching with existing size and make of deep freezers complete all as directed.
2
-
-
... More
Supply & Fix in repair Relay set, PCTR, matching with existing size and make of deep freezers complete all as directed.
2
-
-
... More
Supply & Fix in repair for Drier strainer suitable for matching with existing deep freezers complete including taking out all as directed.
2
-
-
... More
Supply & Fix in repair Thermostat suitable for matching with existing size and make of deep freezers complete all as directed.
2
-
-
... More
Repair and servicing of Split/Window/Cassette air conditioners of capacities 1.5TR to 2.0TR existing make, carefully carrying out the inspection of the all units of Air conditioners check thouroghly, trace out the faults, and the repair the same in original position or MES yard/civil work whop etc. by diconnecting and dismantling the defective units, gas filling, Replace of filters, replacement of unserviceable spare parts, existing serviceable parts etc. including reconnecting, reassembling the same after repair including testing complete all as directed by Engr-in-Charge. Note: (i) The Spares parts required for the repair after opening the air conditioners shall be carried out in the presence of JE/Engr-incharge and the same will measured and paid seperately as supply only under relevent item of BOQ.(ii) The fixing of existing serviceable parts deemed to be included in quoted rates without claiming any extra cost. (iii) All the T&P items , fly nuts,flux welding stick, transportation, jointing materials etc.shall be arrange by the contractor without claiming any extra cost.
15
-
-
... More
Material and labour for Gas filling for refrigerant (Gas R410A/R22/R32) Gas charging with nytrogen testing by charging hose matching with existing size and make of existing airconditioners complete all as directed.
5
-
-
... More
Supply & Fix in repair cooling condenser suitable for matching with existing 1.5/2.0TR capacity of airconditioners complete all as directed.
3
-
-
... More
Supply & Fix in repair Main board suitable for matching with existing airconditioners complete all as directed.
3
-
-
... More
Supply & Fix in repair Display unit suitable for matching with existing airconditioners complete all as directed.
3
-
-
... More
Supply & Fix in repair Drain water pipe suitable slush out condesate water for matching with existing airconditioners complete all as directed.
12
-
-
... More
Supply & Fix in repair Air Filters suitable for matching with existing airconditioners complete all as directed.
8
-
-
... More
Supply & Fix in repair Copper tube suitable for matching with existing airconditioners complete all as directed.
15
-
-
... More
Supply & Fix in repair Copper capillary suitable for matching with existing airconditioners complete all as directed.
15
-
-
... More
Supply & Fix in repair insulation suitable for Copper tube /capillary matching with existing airconditioners complete all as directed.
15
-
-
... More
Supply & Fix in repair Single phase asynchronous PSC Fan motor suitable matching with existing airconditioners complete all as directed.
2
-
-
... More
Supply & Fix in repair capacitor suitable matching with existing motor of airconditioners complete all as directed.
4
-
-
... More
Supply & Fix in repair Heat condenser coil suitable matching with existing of airconditioners complete all as directed.
3
-
-
... More
Supply & Fix in repair Gas valves suitable matching with existing of airconditioners complete all as directed.
5
-
-
... More
Supply & Fix in repair Compressor hermetically sealed suitable matching with existing of airconditioners complete all as directed.
2
-
-
... More
Supply & Fix in repair Power relay Single Phase Contactors suitable matching with existing of airconditioners complete all as directed.
2
-
-
... More
Supply & Fix in repair for Drier strainer suitable for matching with existing airconditioners complete including taking out all as directed.
2
-
-
... More
Supply & Fix in repair Capacitor 36+2.5 MFD,45+4MFD, 50+2.5MFD,55+2.5MFD aluminium casing/aluminium terminals (quadraple fast on) 440volts suitable matching with existing compressor of airconditioners complete all as directed.
6
-
-
... More
Supply & Fix in repair for AC Swing blades with motor suitable for matching with existing airconditioners complete including taking out all as directed.
3
-
-
... More
Supply & Fix in repair PCB for outdoor/indoor unit matching with existing size and make of Inverter type Air conditioner complete all as directed.
3
-
-
... More
Repair and servicing of Solar water heaters of capacities 200 LPD to 300LPD any make, carrying out the inspection of the all units of solar water heaters thouroghly, trace out the faults, and the repair the same in original position or work whop etc. by diconnecting and dismantling the defective units, cleaning of all glass, checking solar insolation, direction of rays, cleaning the makeup water tank inlet and outlet connections, membrane etc. replacement of new spare parts,/old serviceable parts etc. as required at site and reconnecting, reassembling the same after repair including testing complete all as directed by Engr-in-Charge. Note : Note: (i) The Spares parts and jointing material, PCC work etc. required for the repair after opening the solar water heaters shalll be carried out in the presence of JE/Engr-incharge and the same will measured and paid seperately as supply only under relevent item of BOQ. (ii) The fixing of existing serviceable parts shall be included in quoted rates. without claiming any extra cost. (iii) All the T&P items, transportation shall be arrange by the contractor without claiming any extra cost. (iv) The cost of all new fittings PPR/GI Flange Nipple, dead Flange, EPDM Rubber flange Gasket, Flexiable hose pipe, collector nut Bolt Required clamp/Washer shall be arrange by the contractor be included in quoted rates without any claiming any extra charges.
4
-
-
... More
Welding in repairs exceeding 2.5cm and not exceeding 5 cm in length and Thickness of Metal to be welded n exc. 6mm thickness complete all as specified and directed Note : (i) All T&P and welding machines, jointing materials shall be included in quoted rates. (ii) The necessary electricity shall be paid by the contractor on reading of energy meter and tapping shall be provided from Main LT panel only and the cable shall be arrange by contractor without claiming any extra charge.
2
-
-
... More
Supply and fixing in repair Solar water Heating element 3.0 KW matching with existing ISI marked all as directed.
4
-
-
... More
Material and labour for Preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint over steel surface, ht upto 6 meter, complete all as specified and directed.
5
-
-
... More
S&F in Repairs geyser element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round/Squre shape/make of the geyser under repair incl. matching with existing complete all as specified. For Product Code Adonia R of Havells and Usha Misty of Usha
4
-
-
... More
FURNITURE
Almirah Medium/Small Steel with Shelves includes following items (refer Drg NoFD-243/1032), Work will be carried out at various places in station, if required or as directed by Engineer in charge;-
-
-
-
... More
M&L for removing existing UNSV handles and S&F new CP handles as per existing shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
25
-
-
... More
M&L for removing existing UNSV locks and S&F new locks 6 lever harrison/Godrej make of existing shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
90
-
-
... More
M&L for removing existing UNSV 3 way locking device and S&F new 3 way locking device including MS rod of existing shape and size all as specified and shown on drawing or as directed by Engr-in-charge.
12
-
-
... More
M&L for removing existing UNSV clamps and S&F new clamps of existing shape and size including adjustment of shelves where reqd all as specified and shown on drawing or as directed by Engr-in-charge.
250
-
-
... More
M&L for removing existing UNSV hinges and S&F new hinges of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
20
-
-
... More
M&L for removing existing UNSV base/legs and S&F new base/legs of MS sheet 1mm thick of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
20
-
-
... More
M&L for welding to be done where required & grinding till smooth finish, removing of existing dent upto reshaped, removing of old paints by scrubbing with sand/emery paper and repaint the Almirah Med steel outer & inner portion by applying two coats of synthetic enamel paints through spray gun till glossy shine over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. Note :- Shade of paints applied on furniture as approved by the GE.
120
-
-
... More
Locker Steel includes following items (refer Drg NoFD-257/1029), Work will be carried out at verious places in station, if required or as directed by Engineer in charge;-
-
-
-
... More
M&L for removing existing UNSV hinges and S&F new hinges of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
50
-
-
... More
M&L for removing existing UNSV base/legs and S&F new base/legs of MS sheet 1mm thick of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge.
25
-
-
... More
M&L for removing existing UNSV conduit pipe S&F new conduit pipe of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
150
-
-
... More
M&L for welding to be done where required & grinding till smooth finish, removing of existing dent upto reshaped, removing of old paints by scrubbing with sand/emery paper and repaint the Locker steel outer & inner portion by applying two coats of synthetic enamel paints through spray gun till glossy shine over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. Note :- Shade of paints applied on furniture as approved by the GE.
100
-
-
... More
Chair Verandah including following items refer Drg No (FD-19M, 256, FD/MAP-II/06), Work will be carried out at verious places in station, if required or as directed by Engineer in charge :-
-
-
-
... More
Material & Labour for removing paints by cutting/scrubbing from chair verandah and contineous gas welding to the broken parts where reqd after preparing the entire frame repaint the chair with two coats of synthetic enamel paint white all as specified and shown on drawing or as directed by Engr-in-charge .
50
-
-
... More
Material & Labour for removing existing unserviceable cane from chair verandah and recane the chair (both seat & back) with 4 mm wide half round cane plastic of shah/premier make all as specified and shown on drawing No FD-19M or as directed by Engr-in-charge .
20
-
-
... More
Material & Labour for removing existing unserviceable nylone newar from chair verandah and rewieving the chair (both seat & back) with 50mm wide 1st quality of nylone newar all as specified and shown on drawing No FD-256 or as directed by Engr-in-charge .
25
-
-
... More
Material & Labour for removing existing unserviceable Seat & Back from chair verandah and refix the same with new PVC seat & back as shown in Drg. No. FD/MAP-II/06 complete all as specified & shown on drg or as directed by Engr-in-Charge.
20
-
-
... More
M&L for removing existing UNSV rubber shoe and S & F new hard rubber shoes all as specified and shown on drawing or as directed by Engr-in-charge .
150
-
-
... More
Chair Verandah including following items refer Drg No (FD-19M, 256, FD/MAP-II/06), Work will be carried out at verious places in station, if required or as directed by Engineer in charge :-
-
-
-
... More
Material & Labour for removing paints by cutting/scrubbing from chair verandah and contineous gas welding to the broken parts where reqd after preparing the entire frame repaint the chair with two coats of synthetic enamel paint white all as specified and shown on drawing or as directed by Engr-in-charge .
50
-
-
... More
Material & Labour for removing existing unserviceable cane from chair verandah and recane the chair (both seat & back) with 4 mm wide half round cane plastic of shah/premier make all as specified and shown on drawing No FD-19M or as directed by Engr-in-charge .
20
-
-
... More
Material & Labour for removing existing unserviceable nylone newar from chair verandah and rewieving the chair (both seat & back) with 50mm wide 1st quality of nylone newar all as specified and shown on drawing No FD-256 or as directed by Engr-in-charge .
25
-
-
... More
Material & Labour for removing existing unserviceable Seat & Back from chair verandah and refix the same with new PVC seat & back as shown in Drg. No. FD/MAP-II/06 complete all as specified & shown on drg or as directed by Engr-in-Charge.
20
-
-
... More
M&L for removing existing UNSV rubber shoe and S & F new hard rubber shoes all as specified and shown on drawing or as directed by Engr-in-charge .
150
-
-
... More
Chair CB steel with Arms including following items refer Drg No (FD-75(M), Work will be carried out at verious places in station, if required or as directed by Engineer in charge :-
-
-
-
... More
M&L for removing existing UNSV seat S&F new seat made of second class hardwood well seasoned duly caned with 2mm half round cane plastic and providing 4 nos flat iron strips of size 40mm x 25mm x 5mm thick to be welded with the frame all as specified and shown on drawing or as directed by Engr-in-charge.
80
-
-
... More
M&L for removing existing UNSV Back S&F new Back made of second class hardwood well seasoned duly caned with 2mm half round cane plastic all as specified and shown on drawing or as directed by Engr-in-charge.
20
-
-
... More
M&L for removing existing UNSV Arm rest and S&F new Arm rest made of second class hardwood well seasoned as per exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge.
50
-
-
... More
M&L for removing existing UNSV PVC Caps S&F new PVC Caps of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
80
-
-
... More
Chair CB steel without Arms including following items refer Drg No (FD-75(M), Work will be carried out at verious places in station, if required or as directed by Engineer in charge :-
-
-
-
... More
M&L for removing existing UNSV seat S&F new seat made of second class hardwood well seasoned duly caned with 2mm half round cane plastic and providing 4 nos flat iron strips of size 40mm x 25mm x 5mm thick to be welded with the frame all as specified and shown on drawing or as directed by Engr-in-charge ..
30
-
-
... More
M&L for removing existing UNSV Back S&F new Back made of second class hardwood well seasoned duly caned with 2mm half round cane plastic all as specified and shown on drawing or as directed by Engr-in-charge.
30
-
-
... More
M&L for removing existing UNSV Arm rest and S&F new Arm rest made of second class hardwood well seasoned as per exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge.
50
-
-
... More
M&L for removing existing UNSV PVC Caps S&F new PVC Caps of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
100
-
-
... More
Chair School PVC with hand board including following items refer Drg No (FD/E6/MAP/05), Work will be carried out at various places in station, if required or as directed by Engineer in charge :-
-
-
-
... More
M&L for removing existing UNSV writing pad top and providing new writing pad top made of 18mm thick prelaminated particle board exterior grade openable with pvc edging (hinged on RHS) screw to 25mm dia hollow steel pipe inserted in 20mm dia ms rod welded to frame (welding to be done where required ) all as specified and shown on drawing or as directed by Engr-in-charge .
47
-
-
... More
M&L for removing existing UNSV PVC Seat & Back and S&F new seat & back (Blow plast or equivalent) to be fixed with the chair all as specified and shown on drawing or as directed by Engr-in-charge .
20
-
-
... More
M&L for removing existing UNSV book rack and S&F the new book rack of chair school with hand board all as specified and shown on drawing or as directed by Engr-in-charge ..
20
-
-
... More
M&L for removing existing UNSV PVC Caps S&F new PVC Caps of exising shape and size all as specified and shown on drawing or as directed by Engr-in-charge ..
10
-
-
... More
M&L for removing existing UNSV paints by scrubbing with sand/emery paper and repaint the Chair School with hand board outer & inner portion by applying two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and shown on drawing or as directed by Engr-in-charge .
100
-
-
... More
Repair of Tip up Cinema Chair Pad cushion includes following items (Refer Drg No.TP) : work will be carried out at verious places in station, if required or as directed by Engineer in charge:
-
-
-
... More
Supply & Fix seat and back incl tapestry cloth of Tip up Cinema Chair Pad cushion including removal of existing all as specified and shown on drawing or as directed by Engr-in-charge.
100
-
-
... More
Supply & Fix new set of arm rest of Tip up Cinema Chair Pad cushion including removing existing unserviceable set of arm rest arm rest and all as specified and shown on drawing or as directed by Engr-in-charge.
100
-
-
... More
Charpoy GI with ply top includes following items (refer Drg No. FD-220), Work will be carried out at verious places in station, if required or as directed by Engineer in charge:
-
-
-
... More
Removing of existing unserviceable ply wood from GI Charpoy, including threading, tihghtening of all components of GI Charpoy and supply & fixing 12mm thick plywood size 1980x900mm, BWR grade, conforming to the requirement of IS : 303-1989, commercial face both side including replacing 25 x 5mm mild steel flat iron stiffener where required duly bolted with long rails at equal spacing. MS flat shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer. 10 Nos flush headed bolts and nuts with washer shall be provided for fixing of plywood in the short rail /long rail with flat iron of suitable size as directed by Engineer-in-Charge. Edges of Plywood shall be smoothened all around and corners shall be rounded and smoothened as per direction of Engineer-in-Charge. One coat of water resistant adhesive/marine grade fevicol shall be given to edges all around after smoothened the edges.
179
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%