Military Engineer Services Tender

View complete overview of Manipur MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date29 Oct 2024
Closing Soon26 Nov 2024
Tender Amount₹ 1,40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SCHEDULE "A" PART-III (ROADS/PATH ) Details of prepriced Schedule is given in tender documents

1

177341

-

... More
SCHEDULE "A" PART-IV (EXTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents

1

94881

-

... More
SCHEDULE "A" PART-V (EXTERNAL ELECTRIC SUPPLY ) Details of prepriced Schedule is given in tender documents

1

115231

-

... More
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents

1

175388

-

... More
SCHEDULE "A" PART-VII (AREA DRAINAGE ) Details of prepriced Schedule is given in tender documents

1

88359

-

... More
SCHEDULE "A" PART-VIII (RETAINING WALL) Details of prepriced Schedule is given in tender documents

1

164835

-

... More
SCHEDULE "A" PART-IX (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents

1

63287

-

... More
SCHEDULE "A" PART-X (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents

1

369964

-

... More
SCHEDULE "A" PART -XI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.

-

-

-

... More
M & L for drilling and tapping of CI/DI water mains (in positions) for branch connections of the internal dia 50mm GI pipes complete all specified and as directed. Note: Quoted rate shall deemed to be inclusive of excavation/ returning and filling complete all as specified.

1

-

-

... More
M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including HDPE Pipe, 150mm bore, 0.4 Mpa working pressure complete all specified and as directed. Note: The horizontal directional drilling machine boring shall be minimum shot length of 100m horizontal length in a single span and depth shall not be less than 1.20m. The unit rate quoted is deemed to be inclusive for earth work as required at site for boring at starting and termination ends complete all as directed.

10

-

-

... More
Supply, installed and commissioning cubical type CPRI approved LT feeder pillar of size1200mmx1200x300mm box type, outdoor type, dust, vermin, weather proof IP65, of suitable size, slopy canopy, factory made fully compartmentalised made out of 3.15 mm thick CRCA sheet steel duly painting with two coats of epoxy powder coated paint over a coat of primer after undergoing a rigerous metal treatment process involving alkaline, descaling in dilute sulphuric acid degreasing, phosphatising etc for load and non load bearing, back door openable with necessary locking arrangement made of 50 x 6mm MS angle iron frame work, legs grouted in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, totally enclosed with aluminium TPN bus bar of 300 Amp rated suitable for 4 wire ,415 v ,50Hz ,3 ph ,duly colour code by providing PVC sleeeves and carry out internal wiring of accesssories of suitable size pvc copper conductor and connecting the bus bar to MCCB /MCB through suitable copper conductor cable with thimble /lugs etc, and providing cable gland at cable entry into panel with following: (a) Aluminium Bus Bar 300 Amps mounted on porcelain insulator- 01 Set (Set of 04 Nos.) with PVC sleeve insulation INCOMING : (b) MCCB FP 200 Amp ,415v,50 HZ,35 KA -01 No OUTGOING: (c) MCCB FP 160 Amp ,415v,50 HZ,25 KA -02 Nos. (d) MCCB FP 125 Amp ,415v,50 HZ,25 KA -02 Nos. (e) RCB DP 40 Amp ,sensitivity 300mA, 240 Volts, 50Hz AC supply -02 Nos. (f) Digital voltmeter 0-500 volt with selector switch -01 No (g) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (h) Indicator lamp (RYB) LED type - 01 set

1

-

-

... More
Material & labour for construction of 230mm thick brick masonary valve chamber built in CM 1:6 of valve pit of size 900x900x 900mm (internal size) with 100mm thick foundation using PCC 1:4:8 type D2 with 100mm offset,15mm thick plastering internally and 15cm below GL externally in CM 1:6, 3mm thick MS sheet cover ,double door welded to 50mmx50mmx6mm MS angle iron fram fixed with hold fasts in PCC 1:2:4 type B1 coping 50mm thick, 20mmx6mm flat iron hinges with loocking arrangement including lock 65mm brass and keys, MS handles and applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces including excavation & earth work in any type of soil / rock and disposal of surplus soil to a distance not exceeding 50m complete all as specified and directed.

1

-

-

... More
Material and labour for point wiring complete with 1100 volts, FRLSH grade, 1.5 Sqmm PVC insulated, unsheathed multistranded copper conductor cable, ISI marked, drawn through and including heavy duty PVC conduit, 20mm dia including all accessories concealed in walls /Roofs/Floors/Ceiling etc. and modular type pressed metal flush box made out of 1.2mm thick GI of suitable size and including modular type Base/Grid frame & Cover frame for housing modular type switches, sockets and regulators etc. concealed in walls including 1100 volts, FRLSH grade, 1.5 Sqmm PVC insulated, unsheathed multistranded copper conductor cable for earth continuity conductor with colour coding and connecting to Earth dolly for One light/ Fan point / Bell point controlled by One switch complete all as specified ans as directed.

128

-

-

... More
All as per item No 11.05 above but for 3 pin,5 Amp switch Socket outlet on independent board complete all as specified and directed.

24

-

-

... More
All as per item No 11.05 above but for one light point controlled by two way switch complete all as specified and directed.

6

-

-

... More
All as per item No 11.05 above but with 1100 volts, FRLSH grade, 2.5 Sqmm PVC insulated, unsheathed multistranded copper conductor cable, ISI marked, for 3 pin,15 Amp switch Socket outlet on independent board complete all as specified and directed.

16

-

-

... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with 32X6mm GI strip by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.

4

-

-

... More
Supply and fixing submain wiring with two runs of 6 sq.mm Single Core, PVC Insulated, Unsheathed multistranded copper conductor cable,1100 Volts, ISI marked, drawning through and including heavy duty PVC conduit of 25mm dia with all accessories etc. concealed in walls /Roofs/Floors/Ceiling including one run of 6 sq.mm Single Core, PVC Insulated, Unsheathed multistranded copper conductor cable,1100 Volts FRLSH grade earth continuity conductor complete all as specified and directed. Note: (i) Three runs of 6 Sqmm cable and one run of heavy duty PVC conduit of 25mm dia shall be measured as one unit.

259.2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.