Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date27 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2000 Ltr capacity

8

-

-

... More
1000 Ltr Capacity

5

-

-

... More
Disconnecting of existing water supply pipe line from PCC tanks, cutting and removing the existing 10000 ltrs PCC tank with concrete cutting machine carefully without any damage to existing stracture of the buildings and providing PCC foundation not less than 30 cm height,supply and fixing new PVC water storage tank (2X5000) Ltrs capacity, min 3 layers, ISI marked, for each wing hoisting and fixing in position on PCC platform and making all incoming and outgoing connections, GI nipples as required at site, testing all as specified and directed. Note : Removing of old PCC material from the station is also in the contractor's scope and rate included in the item rate

5

-

-

... More
Supply/Fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length.

-

-

-

... More
25 mm bore

200

-

-

... More
40 mm bore

200

-

-

... More
50 mm bore

350

-

-

... More
80 mm bore

250

-

-

... More
Dismantle the existing damaged glow sign board complete from the entrance gate of Pump House and remove from site. Supply & installation Glow Sign board made out of PGI sheet 1 mm thick fixed with transparent PVC acrvlic sheet cover of thickness 2.5 mm, of colour as directed with letters and digits of approx size 25 x 10 CM (Appx 42 Nos) of colour as directed, fixed with and including 18 watts, 240 Volt LED tube light fitting with rods as required at site( @ 2 sqm per one LED fitting) connecting with existing electrical point using 2 core PVC insulated, 1.5 Sqmm PVC insulated and PVC sheathed stranded copper conductor cable of suitable length with switch, fixing the sign board on GI pole/building using necessary fixing arrangements viz clamps, nuts, bolts and washers and welding , excavation and PCC work all as specified and directed. Note :1. Size of sign board and colour will be decided by the department as per the site requirement. 2. GI Pole shall be used for fixing of sign shall only be measured and paid separately under relevant item of Sch 'A'. Remaining items are deemed to be inclusive in the item rate.

25

-

-

... More
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone agregate) as in support of CI pipes foundation and haard standing finishing even and fair without using extra cement all as directed.

5

-

-

... More
Supply and fixing inrepair LED post top lantern 27 watts, IP-65 protection, Acrylate cover and semi-matt high-reflective optic, surge protection,2300 lumens complete with standing pole, light fitting including mounting arrangement with suitable concrete platform including making connections complete all as specified and directed.

8

-

-

... More
S&F in repair looping box of size 130mm x 130mm x 77mm weather proof IP 66/67 including connector blocks four way having suitable size bolt to connect upto 6 Sqmm x 2 core cable two Nos with the help of suitable gland, thimble nuts washers supports by flat aluminium clamps not less than 25mm x 3mm with suitable size nuts,bolts and washers inside and outside looping box including fixing with electric pole and taking out old one of any type complete as directed. Make : Hansel, Cat part ref . KF3535G. or equivalent make as approved by Engr-in charge.

8

-

-

... More
Supply and laying in repair LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- section area 10 Sq. mm, 2 core.

200

-

-

... More
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-

-

-

-

... More
25 mm bore

20

-

-

... More
40 mm bore

18

-

-

... More
50 mm bore

15

-

-

... More
80 mm bore

11

-

-

... More
100 mm bore

3

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil all as specified.

60

-

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified.

53.65

-

-

... More
Removing excavated soil materials exc 250 M but n.exc 500 M and depositing where directed all as specified.

6.35

-

-

... More
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge

15

-

-

... More
S&Laying sub class B bricks (old size) having minimum compressive strenth 75 Kg/sqm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.

1300

-

-

... More
Supply & Fixing in replacement LED building security light fitting 60 Watt AC 230 Volts complete .Make Phillips or Equivalent in crompton greaves/Havells, complete all as specified and as directed.

30

-

-

... More
Supply & Fixing in replacement LED building security fitting 30 Watt AC 230 Volts complete .Make Phillips or Equivalent in crompton greaves/Havells, complete all as specified and as directed.

25

-

-

... More
Supply ,Installation testing & Commissioning in repair of motor actuated butterfly valve (with manual operating wheel) consisting of Quarter turn single phase actuator and wafer type butterfly valve of size 50 mm dia with appropriate bracket/mounting arrangement including two nos limit switches for open and closed condition and splash proof enclosure. Specifications & Features :- Input voltage : 230 V, AC Designed line pressure : 10 kg/sq cm. , Operating angle : 90 degrees, Disc material : CI with nylon coating , Limit switches : 02 Nos. for open and close status Mounting : Direct on valve. Note : Rates are also including of cutting, welding and any modifications in existing line with suitable DI/CI fittings and its fixing are completely included in the item rate and no extra cost will be claimed bu the contractor. Make : Emtork/Hasel Hofener/Ritetork/Siemens/Honeywell

18

-

-

... More
Supply ,Installation testing & Commissioning in repair of motor actuated butterfly valve (with manual operating wheel) consisting of Quarter turn single phase actuator and wafer type butterfly valve of size 150 mm dia with appropriate bracket/mounting arrangement including two nos limit switches for open and closed condition and splash proof enclosure. Specifications & Features :- Input voltage : 230 V, AC Designed line pressure : 10 kg/sq cm. , Operating angle : 90 degrees, Disc material : CI with nylon coating , Limit switches : 02 Nos. for open and close status Mounting : Direct on valve. Note : Rates are also including of cutting, welding and any modifications in existing line with suitable DI/CI fittings and its fixing are completely included in the item rate and no extra cost will be claimed bu the contractor. Make : Emtork/Hasel Hofener/Ritetork/Siemens/Honeywell

5

-

-

... More
Supply ,install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 600A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :- (a) MCCB 4 pole, 415V,400Amps 50 KA - 02 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100% (b) MCCB 4 pole,415V,250 Amps, 36 KA - 04 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% ( c) Change over switch front open hand operated 400 Amp - 1 No. (d) Automatic star/Delta starters panel with all accessories mounting suitable for 75 HP-02 Nos.and 40 HP-02 Nos (e) Phase indicating lamps(RYB)-04 set (f) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set. (g) Suitable CTs for main and for 04 starter panels. Note: before fabrication of panel, the contractor has to take approval from accepting officer on drawing.

2

-

-

... More
Supply ,install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc with suitable Cable alley for provn of cable entries at bottom with cable glands including the following :- (a) MCCB 4 pole, 415V,630 Amps 50 KA - 01 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100% Make :L&T/ABB/Siemens/legrand (b) MCCB 3 pole,415V,250mps 50 KA - 03 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% Make L&T/ABB/Siemens/legrand (c) Soft starter with all accessories mounting suitable for 75 HP-03 Nos. Make :L&T/ABB (d) Phase indicating lamps(RYB)-04 set (e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set. Make: Dip/AE/IMP (f) Suitable CTs for main and for 03 starter panels. (g) Lt Panel and soft starter connect & configurate with existing SCADA system. Note: before fabrication of panel, the contractor has to take approval from accepting officer on drawing.

1

-

-

... More
Supply and Fixing in repair of 4C x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. on wall/ laying in trench complete all as specified and as directed.

785

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.