Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Eprocure
Opening Date23 Sep 2024
Closing Date12 Oct 2024
Tender Amount₹ 46,45,000
Costs
EMD
₹ 93,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676143_1Bid Award Id
ViewTender No
8874/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed.
1330.39
-
-
Returning and filling in, including spreading and well ramming in layers n exc 25 cm all as specified and directed
1056.97
-
-
Removing excavated surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed
273.42
-
-
Supply and laying in 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approval colour complete with fitting i.e.coupler,Tee,elbow clamp for cable protection of size 16 sqmm 4 core complete all as specified and directed
4592
-
-
Disconnecting/taking down the steel tubular Pole which is titling/leaning by engaging suitable crane or manullay complete all as specified and directed
20
-
-
Supply, transport, errecting and fixing steel tubular swaged welded pole of over all height 9 m long complete type 410-SP-22 conforming to IS-2713 (Part I to III 1980 reaffm 2008 with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed Note: (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer.
(iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer and retro reflective tape of Red, Yellow and White color each of 2 inch wide fixed to the poles as directed (iv) Pole below ground shall be tarred by one coat
(v) Poles shall be numbered and the rate for items under Note srl (ii) to (v) above shall be deemed to be inclusive in the quoted rate.
20
-
-
M&L PCC 1:3:6 type C-2 (40 mm size graded stone aggregates) Cement concrete in foundations, filling and mass concrete complete all as specifed and directed..
13.05
-
-
M&L PCC 1:2:4 type B-1 (using 20 mm size graded stone aggregate) as in coping of pole/ fixing of lights including formed work and demolition of existing coping complete all as specifed and directed
6.61
-
-
M&L for PCC 1:4:8 type D-2 (40 mm graded aggregate) Cement concrete in foundations, filling and mass concrete complete all as specifed and directed.
1
-
-
M&L for breaking and romoving old Cement concrete in street light pole coping , using breaker or hevy eqpt exct complete all as specifed.
38
-
-
Labour for trimming / pruning tree branches overhanging or interfering or obstructing electrical pole or street lights complete all as directed in such a way that the clearance between Street light pole and tree branches should not be less than 1.5 mtrs around the Pole/Fitting all as directed by Engr-in-Charge.
50
-
-
S&F in replacement of LED street light fiitting 90 Watt, 230 volt AC outdoor type with pressure die cast Aluminium housing and heat resistant complete with toughned glass, driver,lamp bracket with impect and corroson resistant including thermal management in multiple optics, with IP66 protection complete fixing to pole/wall with necessary nut, bolts and washers complete all as specified and directed.
46
-
-
S & F in replacement of Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, 300mmX40mmX5mm (thickness) electrolytic grade of adequate rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted on wall (at Sudan Dome)and suitable fixing arranement as per site requirement. The overall size of the Busbar panel shall be 350mmx200mmx400mm (LxBxH).including PCC 1:3:6 all as directed and specified by Engr in Chrage.Make: Bajar/Havells/C&S/Legrandl
3
-
-
Supply and fix junction box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed .
Make: Sintex Cat pat No GSJB-3020 or equivalent make as mentioned in makes list in PS
119
-
-
M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT (07 to 08 Mtr) height above ground level , preparing surface for painting , applying two coats of aluminium paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site including making balck and white strips of 30 cms each upto 1.5 m above PCC muffs with black and white paint and marking of pole No 2 m above PCC muff, letter should not be longer than 6 cm height with 16 cm dia circle around the marked NO complete all as such specified and directed
99
-
-
Removing existing damaged reflected strips from pole supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with red colour all as directed by Engr-in- Charge
99
-
-
Removing existing damaged reflected strips from pole supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with yellow colour all as directed by Engr-in- Charge
99
-
-
Removing existing damaged reflected strips from pole supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with whitecolour all as directed by Engr-in- Charge
99
-
-
S&F in repair of GI pipe bracket of 40 mm dia 1.2mtr long bend to shape for street light fitting made out of 40 mm dia GI light grade pipe fixed on pole using new FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
46
-
-
S&F MCB DP 230 volts C curve 6 amps.complete all as specified and directed.
119
-
-
S&F in replacement of digital timer panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, 300mmX40mmX5mm (thickness) electrolytic grade of adequate rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers., comprising of 63 Amps 4 Pole MCCB,TPN 63 Amps, power contactor and 230V digital time switch for controlling LED etc street lights , including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement all as specified and directed
3
-
-
M & L for making hole on a street light pole top and bottom for entry of service wire of 1.5 sqmm disconnecting the existing service connection from junction box and fitting and same has been reconnecting to junction box and fitting complete all as specified and directed.
119
-
-
Material and labour for Tarmac bituminised road cutting by using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm for laying of 80 MM medium grade GI pipe incl refilling and making good with Tarmac/ PCC duly matching with the existing surface complete all as specified and directed.
Note: (a) Quoted rate shall be inclusive of 80 mm GIi pipe medium grade
(b). Quoted rate shall deemed to be inclusive of cost of making good the disturbed surface to match the existing.
50
-
-
All as per item No.26 above but laying of 40mm size medium grade GI pipe
16
-
-
Taking down the existing overhead ACSR conductor and cross arms from the existing position and keep it in safe custody complete all as directed..
6.17
-
-
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanised iron earth wire 4.00 mm dia connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 15 mm dia (medium grade) including concrete pit in PCC (1:3:6) type C-1, RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as shown in electrical plate no 3 all as specified and as directed and testing on completion complete all as specified and directed.
5
-
-
Taking down the existing street light fitting of any type/ make/ wattage from its position checking, Repairing and refixing in position including replacement of connecting cable etc, fixed on pole/building structure, testing all the compenents / parts, wiring all as directed by Engr-in-charge.
73
-
-
Supply and Fixing Integral LED 18 watt outdoor light made in diecast aluminium housing with decorative clear opal acrylic diffuser and IP 65 on PCC foundation with suitable nut and bolts as per site requirement complete all as specified and directed Make- Luker Cat No LOBRD60 or equivalent make as mentioned in makes list in PS
40
-
-
M&L XLPE insulated, armoured heavy duty electric cable with aluminium multistrand conductor, 1100 volts grade, cross sectinal area 4 sqmm 4 core complete all as specified and directed
350
-
-
S & F PVC insulated copper conductor 3 core 1.5 sqmm for from busbar to fitting ,multistranded complete all as specified and directed.
155
-
-
S&F distribution box 2 Module 230V, 5 HZ, IP-65 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, coppper fork type 100 A busbars as short link including end caps, qty-1 nos complete all as specified and directed Make: Legrand Catpart No 601932 or equivalent make as mentioned in makes list in PS
70
-
-
S& F GI tubing medium grade 50 mm dia ISI marked for fixing of light fittings with all fixtures, fixed vertically to ground including necessary earthwork and fixed pole by flat iron clamps, nut,bolt,washers suitable size complete all as specified and directed.
120
-
-
S& F GI tubing medium grade 40 mm dia ISI marked for fixing of light fittings/laid in trenches etc including all fixtures, fixed vertically/horizontally to ground including necessary earthwork and fixed pole by flat iron clamps, nut,bolt,washers suitable size complete all as specified and directed.
40
-
-
Supply and fix in junction box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 325mm x 220 mm x 150 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed Make Sintex Cat pat No GSJB-3726 or equivalent make as mentioned in makes list in PS
4
-
-
S&F in Hanging LED Downlight lights 12 W with WW LED Bulb E 27 with Base with polycarbonate diffuser all as specified and directed. Make: Luker cat part no. LHL402E or or equivalent make as mentioned in makes list in PS
30
-
-
S&F suitable, MCB SPN C Curve 6-10 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
64
-
-
S&F in C Curve MCB TPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
4
-
-
Supply and Fixing outdoor PTL light with 1x12w FOCO Bulb suitable for bulb holder E 27 type with Base with polycarbonate diffuser and IP 54 protection, suitable PCC for light as per site requirement and fixing arrangements complete all as specified and directed Make Luker Catpart No: LGLA7E27 BK or equivalent make as mentioned in makes list in PS
20
-
-
Supply and Fixing Integral LED 18 watt outdoor light made in diecast aluminium housing with decorative clear opal acrylic diffuser and IP 54 protection fixed on PCC foundation with suitable nut and bolts as per site requirement complete all as specified and directed Make- Luker Cat NoLGLRBGE-27 TORNO G3 or equivalent make as mentioned in makes list in PS
4
-
-
S&F in MCB DB 4 way SPN DB (Double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site and as directed
4
-
-
S&F in digital timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB, power contactor and 230V digital time switch for controlling LED/SV etc street lights, including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement all as specified and directed
4
-
-
Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection complete all as specified and directed
334
-
-
S&F Vertical Stationary type electric water heater closed/vented type, inner body made out of copper of capacity 100 Litres suitable for 230 volts, single phase AC 50 HZ Supply ISI marked to IS:2082 (Part /1993) (reffirmed 2004) with latest amendments and having BEE Star (5 Star Rating) complete including grouting with nut bolts/fastners of suitable size complete all as specified and directed
4
-
-
S&F GI mesh flexi connection pipes 15 mm dia suitable for hot & cold water of length not less than 600 mm long with metallic nuts on both ends of pipe complete all as specified and directed.
4
-
-
M&L for Cutting chases for concealed conduit Piping/ wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface all as specified and directed.
120
-
-
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm, 1100 Volts grade in and including PVC conduit medium grade not less than 25 mm complete with conduit accessories such as bends, tees etc. and copper cable 4 sqmm continuous earth wire complete all as specified and directed Note: Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with PVC conduit shall be measured as one RM
120
-
-
S&F MCB single pole 32 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed.
6
-
-
S&F Modular AC Box with 20 A DP MCB, with surface mounted Unbreakable Heavy Duty Plastic Enclosure including 1 nos ISI marked Plug Top and 1 nos 20 A DP modular MCB complete all as specified and directed.
Make: Roma Cat part no 98492 or equivalent make as mentioned in makes list in PS
6
-
-
S&F 15 mm bore GI tubing medium grade with all fittings such as tee, bend, joint etc. and fixed to wall or laid in floor complete all as specified and directed.
16
-
-
S&F 15 mm bore stop valves, fancy type, cast chromium plated, high pressure, screwed both ends for iron pipe or for union and fixed comple all as specified and directed.
4
-
-
S&F 15mm bore bib taps, fancy type, cast chromium plated, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
4
-
-
M&L for cutting existing steel tubing for alteration or additions of 15 mm dia with all fittings complete all as specified and directed.
6
-
-
M&L for concealed point wiring in and including new PVC conduit medium grade with the help of multi-stranded unsheathed FRLSH copper cable 1.5 sqmm 650/1100V conforming IS:3419 -1988 adhereing to colour code including earth wire of the size 1.5 Sqmm green colored with modular steel or cast iron terminal boxes and modular cover plates as required at site including making good the distrubed surfaces and matching it with existing surface for the following :- One light / fan point controlled by one switch one way
20
-
-
S&F modular switch 1 way 10 A 1 module complete all as specified and directed.
20
-
-
S&F ceiling rose, 3 terminals / PVC / Polycarbonate, isolated body complete all as specified and directed
20
-
-
S&F 10W, 230V, LED batten suitable for indoor application of color temperature 6000K surface/wall mounted LED batten including connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and directed.
12
-
-
S&F 20 watt, 3 in1, 230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed.
Make- Luker LT20PR 3-in-1 or equivalent make as mentioned in makes list in PS
8
-
-
M&L preperation of old/new steel surfaces over 10 cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint over a coat of red oxide primer.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements