Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date28 Jan 2025
Closing Date17 Feb 2025
Tender Amount₹ 31,95,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for RCC 1:2:4 (nominal mix) type B1 using 20mm graded stone aggregate as in Beams, cantilevers, bressummers,lintels over 1.5m span etc complete, including demolition of old reinforced cement concrete any description and in any position and removing demolished material from site to out side MoD land complete all as specified and directed.

1.33

-

-

... More
Use and waste of formwork to soffits of suspended slabs, landings, shelves and similar work exc 200mmm thick horizontal or sloping complete all as specified and directed.

8.88

-

-

... More
M&L Mild steel TMT bars 10mm dia and over cut to length bend to shape as required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe 410-O or Fe 310-O complete all as specified and directed.

37

-

-

... More
M&L Mild steel TMT bars above but 6 to 8mm dia bar and over cut to length bend to shape as required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe 410-O or Fe 310-O.Ditto complete all as specified and directed.

48

-

-

... More
M&L for 50mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub bases of floors, etc finished the surface even and rough to receive the topping layer etc complete, including demolition of old cement concrete unreinforced in ground floor and pavings n.exc 15 cm thickness (below or above ground level) and removing demolished material from site to out side MoD land complete all as specified and directed.

854

-

-

... More
M&L for 25 mm thick PCC (1:2:4) type B-0 using 12.5 mm graged stone aggregate as in floors etc complete, including demolition of old cement concrete unreinforced in ground floor and pavings n.exc 15 cm thickness (below or above ground level) and removing demolished material from site to out side MoD land complete all as specified and directed.

806

-

-

... More
M&L for Machine cut kota stone slab of area not less than 0.30 sqm as in flooring, etc. 20mm - 25mm thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.

806

-

-

... More
M&L for Machine cut kota stone slab of area not less than 0.30 sqm as in skirting / dado /risers of steps etc 20mm - 25mm thick fixed over & including 10 mm thick rendering in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.

26.4

-

-

... More
Taking down chowkhats or frames with shutters (without taking off shutter from frames) exc. 1.5 sq. m but not exc 4.0 sqm each complete all as specified and directed.

4

-

-

... More
S & F of Steel rolling shutters with ball bearing, but gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified in SSR part-I clause 10.23 complete all as specified and directed.

44.4

-

-

... More
S & F Saftey lever locks mild steel with four levers for rolling shutters complete all as specified and directed.

8

-

-

... More
S & F Ball bearing for rolling shutters complete all as specified and directed.

12

-

-

... More
M&L applying two coats of synthetic enamel paint over a coal of red oxide / zinc chrome primer on surfaces of any description, over 10cm width or girth, not otherwise described on newly steel surfaces including preparation of new steel surfaces complete all as specified and directed.

97.68

-

-

... More
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) n.exc 1.5 Sqm each complete all as specified and directed.

12

-

-

... More
S&F aluminium windows sliding type three track powder coated consisting of frame bottom with sutter of size min 92 X 31.75 mm,side and top of size min 92 X31.75, shutters vertical 39X20 mm,shutter top &bottom of size min 20X39 mm ,shutter interlock min size 39X20 mm with rollers and concealed locking arrangements with 5 mm thick plain sheet glass with rubber gasket,brush and aluminium beading , aluminium grill with fixing arrangement stainless steel mess 0.36 mm dia and aperture 1.45 mm etc including necessary cutting holes on wall and floor and confirming to IS complete all as specified and directed.(Al. section thickness 1.50 mm }.

12.96

-

-

... More
M&L for 18-20mm thick pre-polished Granite slab, machine cut, for floors/ shelves, window cill, dado,steps, jambs and piller top laid over 15mm thick in CM 1:4 cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone complete all as specified and directed.

6.48

-

-

... More
Rounding to edges of stone slabs one edge, such as in steps, cooking platforms window cills and other similar situations etc complete all as specified and directed.

21.6

-

-

... More
M & L for complete removal of existing treatment and applying two coat of acrylic distemper over a coat of interior primer and applying birla / J. K. wall care white putty 1 mm thick in two layer for levelling the surfaces incl. preparation of old surfaces of walls etc complete all as specified and directed. NOTE :- The VOC contents of the distemper shall be less than 50 gms per litre. The shade & colour shall be as approved by GE.

500

-

-

... More
M & L for complete removal of existing treatment and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm including properly making of V shape crakes wherever applicable and filling of all crakes with crakes seal over and including priming coat of exterior primer applied @ 0.90 litre / 10sqm over old surfaces and applying birla / J. K. wall care white putty 1 mm thick in two layer for levelling the surfaces including preparation of surfaces of old decorated walls etc complete all as specified and directed.

575

-

-

... More
M&L for complete removal of existing treatment of old ceiling surfaces and applying two coats of distemper oil emulsion on ceiling surfaces complete all as specified and directed.

740

-

-

... More
M&L for cement plaster 15mm thick in cement mortar (1:4) with and including WPC @ 3% by weight of cement, finished the surfaces even and smooth without using extra cement, including taking down old cement or cement lime plaster any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc and removel of rubbish off the premises to out side MoD land complete all as specified and directed.

60

-

-

... More
M & L for applying two of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over new surfaces and applying birla / J. K. wall care white putty 1 mm thick in two layer for levelling the surfaces including preparation of surfaces of new walls etc complete all as specified and directed.

60

-

-

... More
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement, including taking down old cement or cement lime plaster any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc and removel of rubbish off the premises to out side MoD land complete all as specified and directed.

60

-

-

... More
M & L for applying two coat of acrylic distemper over a coat of interior primer and applying birla / J. K. wall care white putty 1mm thick in two layer for levelling the surfaces incl. preparation of new surfaces of walls etc complete all as specified and directed. NOTE :- The VOC contents of the distemper shall be less than 50 gms per litre. The shade & colour shall be as approved by GE.

60

-

-

... More
M&L for 75mm thick PCC 1:3:6, type C-1 (using 20mm graded stone aggregates) as in plinth protection surface finished even and smooth without using extra cement & provided with construction joint on the interval not more than 3.0m and filled with bitumen and sand mortar in 1:3, including demolition of old cement concrete unreinforced in ground floor and pavings n.exc 15 cm thickness (below or above ground level) and removing demolished material from site to out side MoD land complete all as specified and directed.

132

-

-

... More
M&L for hardcore of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface using broken stones or boulders complete all as specified and directed.

33.12

-

-

... More
Material and labour for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade chemically treated with approved colour, design & pattern as in foothpath, parks, lawns, drive ways or light,heavy traffic parking etc. of required strenght, thickness & size / shape, , laid in required colour & pattern over and including 30 to 50 mm thick uniformly levelled surface of stone dust cushioning, , filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement, including PCC 1:2:4 type B-0 as in coping all around of size 100 x100 mm thick, including Dismantling old Stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry and pointed and removel of rubbish off the premises to out side MoD land complete all as specified and directed.

40

-

-

... More
Taking down of old roof treatment of any description including demolition of mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr and n exc 500 mtr from the roof of height 3 to 9 m height etc and applying new water proofing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/sqm and thickness not less than 3.00mm comprising with following items with and including materials and labour as under:- (i) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. For cast iron drain outlets a groove shall be cut as specified and directed. (ii) M&L rendering 10mm thick in cement mortar 1:4 mixed with and including water proofing compound @ 200ml per 50 kg bag of cement applied over roof slab. (iii) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated. (iv) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm. (v) Laying of water proofing teratment of weight not less than 3 Kg / sqm and thickness not less than 3.00mm APP modified polymeric water proofing membrane composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc. (vi) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane. (vii) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directed at site . (viii) A fillet of PCC (1:2:4) of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of dirction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded and including M&L for cutting of grooves at wall all around 65mm deep 10mm wide for APP membrane to be laid in gap as required on site as directed by Engineer In Charge.

500

-

-

... More
M & L for PCC ( 1: 2: 4) type B-0 using (12.5mm graded stone aggregate) etc on roof top as a leveling course / padding to maintain the slope,finished the surfaces even and smooth without using extra cement, including demolition of existing PCC etc complete all as specified and directed.

12.5

-

-

... More
S & F Rotational moulded poly-ethylene multilayer water storage tanks (cylinderical vertical with closed top) 500 litres capacity, triple layer in construction white in colour hoisted and fixed in position with and including PVC float valve assembly including assessories with float valve 20mm dia, including dismantaling of old tank with all fittings complete all as specified and directed.

4

-

-

... More
Disconnecting existing water tanks, setting aside (or lowering if required) for Cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc capacity of tank and reconnecting and refixing in position capacity of tank exc 250 and n.exc 500 ltr complete all as specified and directed.

2

-

-

... More
S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors, including taking down old 15 mm dia GI tubing and connections complete all as specified and directed.

25

-

-

... More
S&F GI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors, including taking down old 20mm dia GI tubing and connections complete all as specified and directed.

25

-

-

... More
Taking down or up steel/ Pvc tubing and connection including cleaning and refixing the same 15mm bore complete all as secified and directed.

25

-

-

... More
Taking down or up steel/ Pvc tubing and connection including cleaning and refixing the same 20mm bore complete all as secified and directed.

25

-

-

... More
Taking down or up steel/ Pvc tubing and connection including cleaning and refixing the same 25mm bore complete all as secified and directed.

10

-

-

... More
S&F in repair 110mm dia PVC(SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls complete all as specified and directed.

20

-

-

... More
M&L for brickwork with subclass 'B' bricks (old size), straright or curved on plan exceeding 6m mean radius built in Cement Mortar 1:4, including demolition of old brickwork or stone/boulder masonry, built in cement or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles and removing demolished material from site to out side MoD land complete all as specified and directed.

1

-

-

... More
Taking down old cement or cement lime plaster any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc and removel of rubbish off the premises to out side MoD land complete all as specified and directed.

30

-

-

... More
M&L for 15 mm thick rendering in cement mortar (1:4) on brick / concrete/ stone surfaces finished even and smooth without using extra cement complete all as specified and as directed.

35

-

-

... More
M&L of raised pointing to RR masonary walling brought upto course in CM (1:4) complete all as specified and as directed.

1.5

-

-

... More
M&L for preparation of the old plastered surfaces of existing treatment and applied for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50, Antifungal/ Anti Algai properties in two coats not less than 1.79 litre(undiluted)/10 Sqm diluted with water as per manufacturer's instruction over and including one coat of exterior primer over on old plastered surface complete all as specified and directed.

725

-

-

... More
M&L for preparation of the new plastered surfaces and applied for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50, Antifungal/ Anti Algai properties in two coats not less than 1.79 litre(undiluted)/10 Sqm diluted with water as per manufacturer's instruction over and including one coat of exterior primer over on new plastered surface complete all as specified and directed.

35

-

-

... More
Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed.

70

-

-

... More
M&L for concealed point wiring for one light or fan point controlled by one switch with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.

40

-

-

... More
M&L for concealed point wiring for one 5 Amp independent socket point controlled by one switch with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.

14

-

-

... More
M&L for concealed point wiring for one 3 pin ,5 Amp socket point with other switch on the same board with 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.

6

-

-

... More
M&L for concealed power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and as directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.

10

-

-

... More
S&F Modular switch, one way, 6 Amp 230, 1 module complete all as specified and directed .

60

-

-

... More
S&F Modular switch, two way, 6 Amp 230, 1 module complete all as specified and directed .

4

-

-

... More
S&F socket Modular 6 Amp-2/3 pin combined 2 module complete all as specified and directed .

20

-

-

... More
S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt complete all as specified and directed .

10

-

-

... More
S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt complete all as specified and directed .

10

-

-

... More
S&F ceiling rose, surface backlite,three terminal complete all as specified and directed .

40

-

-

... More
S&F LED TL fitting 20/18 watt for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver long life corresion resistance impact proof surface mounting IP66 Lumanires PC housing in opeal finish coverwith high brighnesscomplete all as specified and directed. Make- Havells Cat Part No LHEXBLP7PN1W020, 4 feet or eqvt in Bajaj cat part No BCLSB 20 WH/ CG Cat par No LCTC-18-CDL

30

-

-

... More
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizecomplete all as specified and directed .

10

-

-

... More
M&L for concealed sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4.00 sqmm (for main current) drawn in & incl PVC conduit conduit less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 2.50 Sqmm (As earth wire) PVC FRLS insulated unsheathed stranded copper conductor as a continuous earth wire and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green, incl. taking down old unserviceable sub main wiring complete all as specified and as directed. Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core of size 4.00 sqmm for main current and one run of single core of size 2.50 sqmm for earth continuity conductor & one run of pvc conduit shall be measured as one unit length.

50

-

-

... More
S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed.

24

-

-

... More
S&F testing and commissioning of MCB SPN 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed.

4

-

-

... More
S&F of sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar etc, including taking down existing DB complete all as specified and as directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.

4

-

-

... More
M&L for provn of Earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion. Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.

2

-

-

... More
Supply and laying cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross sectional area 16 sqmm 4 core, including taking out of old cable complete all as specified and as directed.

45

-

-

... More
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for laying of cable and getting out hard / dense soil complete all as specified and directed.

8

-

-

... More
M&L for sand cushioning in trenches for protection of the cable etc complete all as specified and as directed. Note: Punned thickness shall be measured for payment purpose.

3.5

-

-

... More
Returning filling, spreading, leveling, watering and well ramming in layers n. exc 25 cm thick complete all as specified and directed.

5.9

-

-

... More
Removing excavated surplus material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr from starting point complete all as specified and directed.

2.1

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.

270

-

-

... More
S&F in replacement of GI Pipe light grade 40 mm dia ISI marked on pole on wall or laid in trenches incl all fittings (nut, bolt, clamps & washers) complete all as specified and directed.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.