Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 20,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685157_1Tender No
81167Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for glazed ceramic coloured tiles, of size 300x400/450x7 mm thick as in dado/skirting and riser to steps in patches and jointed in neat cement slurry and pointed in white or coloured cement to match over and including10 mm thick cement plaster in CM 1:4 finished fair and even on rough finished brick or concrete surfaces complete all as specified and as directed
30
-
-
Demollition of Cement concrete (unreinforced) n exc 15 cm thickness (below or above ground floors) complete all as specified and directed .
1.4
-
-
M&L for Plain cement concrete 1:2:4, as in levelling course, floor finishes, coving , coping, benching, cills, steps, plinth courses, string courses, lacing courses, chajja top roof kerbs, water troughs and the like weathering, slightly rounded or chamfered angles and throating including necessary formwork etc complete all as specified and directed by Engr-in charge.
1.4
-
-
Repair to chajja soffit and ceiling plaster, exposed reinforcement with 15 to 25 mm thick in two layers plaster in CM 1:3 in patches to make the surface even and smooth including chipping and cleaning the adjacent surface, applying cement slurry @ 3 Kg/sqm at ant height with necessary scafoldings complete all as specified and as directed.
22
-
-
S&F in repair 19/20 mm dia pre powder coated aluminium curtain rods, with decorative single Knob and brackets on either sides in doors/windows complete all as specified.
15
-
-
S&F in repair 19/20 mm dia stainless Steel fancy type curtain rods with decorative single Knob and brackets on either sides in doors/windows complete all as specified.
15
-
-
S&F stainless steel curtain rod Knob with SS screw for existing curtain rods complete all as specified.
20
-
-
S&F in repairs vitreous China Water closet squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests complete including provision of lime concrete bedding complete all as specified and as directed by Engr-in charge.
1
-
-
S&F in repairs vitreous china wash down water closet (Pedestal pattern) white with 'S' or 'P' trap fixed to floor with suitable zinc coated screws and white cement complete all as specified.
3
-
-
S&F in repairs vitreous china wash basin, white flat back, size 550 X 400 mm fixed to wall by anchor bolts, waste pipe etc complete all as specified and as directed by Engr-in charge.
2
-
-
S&F in repairs Vitreous China Urinal, Half stall type, white including CP Brass waste coupling, PVC waste pipe & CP Grating complete all as specified and as directed by Engr-in charge.
1
-
-
S&F in repairs vitreous china counter wash basin, Oval shape, size 560 X 400 mm fixed to Granite platform with white or coloured cement etc complete all as specified and as directed by Engr-in charge.
Make: Cat No. S2030103 of Cera or equivalent in Hindware/Parryware etc as approved by GE.
1
-
-
S&F in repair Plastic water closet seat cover (any type) black or white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engr-in charge.
25
-
-
S&F in repair PVC low level flushing cistern 10 Ltr capacity incl float valve and flush pipe complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repairs 15mm bore pillar cock, swan neck quarter turn, chromium plated cast copper alloy , fancy type, screwed down, high pressure, with long screwed shanks and fly nuts, screwed complete all as specified and as directed by Engr-in charge.
2
-
-
S&F in repairs 15mm bore cast copper alloy pillar tap, fancy type with capstan head, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed complete all as specified and as directed by Engr-in charge.
15
-
-
S&F in repair 15mm bore Bib taps, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, complete all as specified and as directed.
10
-
-
S&F in repairs Angle cock/ Stop cock,15 mm dia, half/quarter turn, cast copper alloy, chromium plated, fancy type with long shank and cup, complete all as specified
20
-
-
S&F in repair 15 mm Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed complete all as specified and as directed by Engr-in charge.
6
-
-
S&F in repair 32mm bore waste coupling, brass chromium plated for wash hand basin with long screwed shanks and fly nuts complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repair 40mm waste coupling, brass chromium plated suitable for steel sink including strainer etc complete all as specified and as directed by Engr-in charge.
1
-
-
S&F in repair 32mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed by Engr-in charge.
4
-
-
S&F Urinal spreader for fixing with 15 mm dia pipe. with connecting CP tube complete all as specified and as directed by Engr-in charge.
2
-
-
S&F in repairs PVC white flexible waste pipe, collapsible type complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repais Health faucet (ABS Body) chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engr-in charge.
25
-
-
S&F in repairs 125 mm shower rose chromium plated with swivel joints suitable for fixing to 15 mm GI/UPVC/CPVC pipe or union complete all as specified and as directed by Engr-in charge.
15
-
-
S&F in repairs for brass spindle suitable for bib taps /stop valves/mixers of size 15/20mm as sper site requirement complete all as specified and as directed by Engr-in charge.
20
-
-
S&F in repairs 15 mm bore high density poly-ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc, including required bend, tee, socket etc complete all as specified and as directed by Engr-in charge.
20
-
-
S&F in repairs 20 mm bore high density poly-ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc, including required bend, tee, socket etc complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repairs 25 mm bore high density poly-ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc, including required bend, tee, socket etc complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed by Engr-in charge.
30
-
-
S&F in repairs 600mm x 600mm bevelled edge frameless mirror of selected quality glass with decorated SS cup washers and brackets and screws complete all as specified and as directed by Engr-in charge.
4
-
-
S&F in repairs 450mmx600mm mirror PVC framed white colour of selected quality fixed to wall with pvc rawal plug and screws complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repairs Stainless steel soap dish fixed with pvc rawal plugs and chromium plated brass screws complete all as specified and as directed by Engr-in charge.
5
-
-
S&F in repair CP grating (with/without hole) 100/125 mm (square/circular) shaped as per site requirment complete all as specified and as directed by Engr-in charge.
10
-
-
Dismantling of drain pipes 110/75mm dia (PVC (SWR), Salt glazed ware, AC) set in any position complete all as specified and as directed by Engr-in charge.
20
-
-
S&F in 110 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches, floor or in wall with clamps complete all as specfied and directed.
10
-
-
S&F 75 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches , floor or in wall with clamps complete all as specfied and directed.
10
-
-
S&F 110mm PVC(SWR) bends complete all as specified and as directed by Engr-in charge.
2
-
-
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed by Engr-in charge.
2
-
-
M&L for 75mm dia outlet PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement complete all as specified and as directed by Engr-in charge.
1
-
-
S&F 75mm dia outlet PVC (SWR) multi floor trap with CP grating including jointing with solvent cement complete all as specified and as directed by Engr-in charge.
1
-
-
S&F 75 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed by Engr-in charge.
1
-
-
S&F 75 mm PVC (SWR) vent cowl complete all as specified and as directed by Engr-in charge.
1
-
-
S&F 110 mm PVC (SWR) vent cowl complete all as specified and as directed by Engr-in charge.
1
-
-
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
18
-
-
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as per direction of Engineer-In-Charge.
5.6
-
-
Repairing Shutter of any description, exceeding. 1 sqm and not exceeding 2 sqm each resecuring or easing & without taking down from the frame at site with all necessary tools, nails screws etc complete all as specified.
15
-
-
Taking down Chowkhats or frames n.exc 1.5 sq. m each but with shutters (without taking off shutters from the frame) complete all as specified and as directed by Engr-in charge.
4
-
-
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame) complete all as specified and as directed by Engr-in charge.
3
-
-
Taking down shutter of any description, n exc. 1Sqm each and removing from site complete all as specified and as directed by Engr-in charge.
5
-
-
Taking down shutter of any description, exc. 1sqm and not exc. 2 sqm each and removing from site complete all as specified and as directed by Engr-in charge.
3
-
-
S&F of second class H.W plain solid straight chowkats and frames wrought framed rebated on chamfered put together with glue pinned at joints etc complete
0.1
-
-
S & F 30 mm thk Plain, framed, panelled shutters (any number of panels), with panels of timber (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted complete all as specified and as directed by Engr-in charge.
4
-
-
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
4
-
-
S&F 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any number, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed by Engr-in charge.
4.5
-
-
S&F aluminium alloy wire cloth. 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engr-in charge.
4.5
-
-
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engr-in charge.
40
-
-
M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of pink prime all as directed and as specified
17.6
-
-
S&F 100 mm size stainless steel butt hinges medium weight, fixed to chowkhat all as specified and as directed by Engineer-In-Charge.
12
-
-
S&F in repairs 100 mm size Mild steel butt hinges medium weight, fixed to chowkhat all as specified and as directed by Engineer-In-Charge.
18
-
-
S&F 75 mm size Mild steel butt hinges medium weight, fixed to chowkhat all as specified and as directed by Engineer-In-Charge.
3
-
-
S&F 100 mm long aluminium anodised barrel tower bolt all as specified and as directed by Engineer-In-Charge.
25
-
-
S&F 150 mm long aluminium anodised barrel tower bolt all as specified and as directed by Engineer-In-Charge.
20
-
-
S&F 150 mm long aluminium handle fabricated type anodised all as specified and as directed by Engineer-In-Charge.
15
-
-
S&F in repairs 250 mm size Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repairs Brass Cromium plated tubular towel rail, D type, 60cm long between flanges complete all as specified and as directed by Engr-in charge.
10
-
-
S&F in repairs Door closer hydraulically regulated, Aluminium (extruded section) body, designation No. 2, universal type, suitable for door shutters of 800 to 950 mm in width and of weight between 36 to 60 kg fixed with zinc cozted screws complete all as specified and as directed by Engr-in charge.
2
-
-
S&F in repairs 200 mm, size mild steel ordinary rat tail rod pattern springs including roller and roller plate fixed with welding/self taping screws complete all as specified and as directed by Engr-in charge.
20
-
-
S&F in repairs 140mm size door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring with zinc coated suitable size screws complete all as specified and as directed by Engr-in charge.
10
-
-
M&L for preparation of old decorated surfaces of walls (plastered or unplastered) and cornices, by brooming down, scrapping down smoke soot, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white wash on walls all as specified and directed by Engr-in-Charge.
250
-
-
All as per srl item No 74 here in before but on ceiling complete all as specified and as directed by Engr-in charge.
190
-
-
Complete removal of old existing treatment on wall surfaces, washing rubbing down and stopping of distempered and painted surfaces and applying two coats of Distemper acrylic emulsion over a coat of acrylic internal primer and a coat of cement based putty complete all as specified and directed.
150
-
-
M&L for preparation of old decorated wall surfaces including brooming down, scrapping down smoke soot, mould, moss and efforescent salts, trading oil and grease spouts and filling the cracks /depressions with wall care putty and applying one coat of distemper acrylic emulsion complete all as specified and as directed by Engr-in charge.
1010
-
-
All as per srl item No 77 here in before but on ceiling surfaces complete all as specified and as directed by Engr-in charge.
100
-
-
M&L preparation of old decorated wall surfaces including brooming down, scrapping down smoke soot, mould, moss and efforescent salts and trading oil and grease spouts and cleaning with water and filling the cracks /depressions with cement based putty and applying one coat of exterior emultion weather coat paint of any tint as approved complete all as specified and as directed by Engineer-in-Charge.
300
-
-
M&L for preparation of old painted wooden surface of any description not otherwise described over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in charge.
20
-
-
S&F in repairs Friction stay hinges size 200 x 19 x 1.9 mm made of stainless steel (SS-304 grade) to the side/top hung Aluminium windows, of approved quality, with necessary stainless steel screws etc complete all as specified and as directed by Engr-in charge.
6
-
-
S&F in repairs Friction stay hinges, size 200 x 19 x 1.9 mm made of stainless steel (SS-304 grade) to the side/top hung Aluminium windows (external side), of approved quality, with necessary stainless steel screws etc including taking down aluminium window with frame from its position and refixing in the same opening after replacing the friction hinges and other minor repairs at multi story building complete all as specified and as directed by Engr-in charge.
30
-
-
S&F Aluminium powder coated casement shutter only Casement type glazed/gauzed with & including 4 mm thick plain glass with glazing beading & rubber/EPDM Gasket or stainless steel mosquito proof wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm in panes, each shutter provided with powder coated 01 Nos aluminium handle and 02 Nos (250x19x1.9mm)mm Stainless steel friction stay hinge complete all as specified and directed by Engr-in-Charge.
Casement type (34 mm Series) sections with following sections of HINDALCO or equivalent.
(a) "Z" shutter 34.00 x 44.50 x 2.00 mm Section No 4124
(b) Jointing cleat (50x50x4.90mm) Section 2081
(c) Glazing Beading (25x24x1.20mm) Section 4135
4
-
-
S&F 4 mm thick Sheet glass ordinary quality & glazing with aluminium / wooden beading and clip in square n-exc. 0.5 sqm in each pane 4 mm thick complete all as specified & directed.
5
-
-
S&F in repairs 4 mm thick Sheet glass ordinary quality & glazing with aluminium/ wooden beading and clip in square including hacking down complete all as specified & directed.
10
-
-
Grouting sides of rain water pipes and RCC roof/chajja junctions with CM 1:1 after cleaning the surface and applying cement slurry mixed with water proofing compound to stop the water leakage from the sides of rain water pipe from the top and bottom of slabs complete all as specified and as directed by Engr-in charge.
5
-
-
Removing vegeitation/plants from buildings near chajjas, water tanks etc and removing roots completely all as specified and as directed by Engr-in charge.
20
-
-
Running welding in repairs any discription complete all as directed by Engr-in-Charge
20
-
-
Taking down carefully defective switch /socket /regulator/bell/bell push/holder/light fittings etc after disconnecting the electrical connections safely and keeping ready of any size/ make complete all as specified and as directed.
292
-
-
Supply and fix switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by the Engr-in-Charge
50
-
-
Supply and fix switch piano, flush type, single pole, two way, 6 Amps,complete all as specified and as directed by the Engr-in-Charge
10
-
-
Supply and fix switch socket combination outlet multipurpose 2 in 1, 3 pin, 6 Amps and 2 pin 6 Amps flush type complete all as specified and as directed by the Engr-in-Charge
38
-
-
Supply and fix switch socket combination outlet multipurpose, 6 Amps and 16 Amps flush type complete all as specified and as directed by the Engr-in-Charge
40
-
-
Supply and fix socket outlet multipurpose 3 pin 5 Amps complete all as specified and as directed by the Engr-in-Charge
30
-
-
Supply and fix socket outlet multipurpose 5 Amps and 16 Amps complete all as specified and as directed by the Engr-in-Charge
32
-
-
Supply and fix switch piano, flush type, single pole, one way, 16 Amps,complete all as specified and as directed by the Engr-in-Charge
26
-
-
Supply and fix electronic fan regulator tepped type, fluh type suitable for existing ceiling fans fixed on phenolic laminated sheet etc as required complete all as specified and as directed by the Engr-in-Charge
16
-
-
Supply and fix ceiling rose PVC poly carbonate, isolated body with two to three terminals including connection ISI marked complete all as specified and as directed by the Engr-in-Charge
10
-
-
Supply and fix lamp holder, PVC / Poly carbonate type with cord grip cap suitable for pendent/batten/angle fittings complete all as specified and as directed by the Engr-in-Charge
10
-
-
Supply and fix bell push, flush type, 5 Amps complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix bell Ding Dong AC. 230 volts, single pole complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix Modular switch 1 way 6A,1 module complete all as specified and as directed by the Engr-in-Charge
6
-
-
Supply and fix Modular switch 1 way 16A,1 module complete all as specified and as directed by the Engr-in-Charge
6
-
-
Supply and fix Modular Bell push 6A, 1 module complete all as specified and as directed by the Engr-in-Charge
2
-
-
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix MCB SP 6 to 32 Amps, 240 Volt, having breaking capacity 10 kA, C curve with visual indication complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix MCB SPN, 32 Amps, 240 Volt, having breaking capacity 10 kA, C curve complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix MCB SPN, 40 to 63 Amps, 240 Volt, having breaking capacity 10 kA, C curve complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix MCB TPN, 40 to 100 Amps, 415 Volt, having breaking capacity 10 kA, C curve complete all as specified and as directed by the Engr-in-Charge
2
-
-
Supply and fix RCBO 25 Amps 30 MA sensitivity short circuit current rating 6 KA double pole complete all as specified and as directed by the Engr-in-Charge
2
-
-
Supply and fix Recess mounted type aesthetic look LED down light fittings 15 W suitable for modern work place complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix in repair of surface mounted LED batten four feet long, 22/20/18 Watt comprises of polycarbonate housing, integrated electronic driver, diffuser etc and all accessories pre-wired including connecting up completecomplete all as specified and as directed by the Engr-in-Charge.
76
-
-
Supply and fix in repairs of surface mounted LED batten 2 feet, 10 Watt comprises of polycarbonate housing, integrated electronic driver, diffuser etc and all accessories pre-wired including connecting up complete all as specified and as directed by the Engr-in-Charge
20
-
-
Supply and fix in repairs LED lamp B22 9/10 watts suitable for existing angle/batten holder comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and as directed by the Engr-in-Charge
78
-
-
Supply and fix in repairs of decorative wall light fixture made up of polycarbonate comprises of high efficiency diffuser polycarbonate cover, lamp 9 Watts warm white, etc and all accessories pre-wired including connecting up complete all as specified and as directed by the Engr-in-Charge
4
-
-
Supply and fix in repairs of LED building security light fitting 25 watts protection comprises of a pressure die cast aluminium housing, polycarbonate cover, high power LED with lenses, 10KV built-in-surge protection, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete all as specified and as directed by the Engr-in-Charge.
4
-
-
S&F in repair PVC round sheathed (flexible) industrial copper cable of size 1.5 Sqmm incl 20 mm PVC conduit complete all as specified and as directed by the Engr-in-Charge
10
-
-
S&F in repairs 3 mm thick ISI marked laminated sheet cover and brass screw with cup washers for fixing switches/sockets/regulators etc cut to suitable size, cutting holes for fixing switches, regulators, sockeets etc including taking down of old sheet complete all as specified.
2
-
-
S&F in repair sheet metal enclosure with two pin and earth plug and socket complete with one MCB 20 Amps single pole having breaking capacity 10 kA complete all as specified.
4
-
-
S&F in repair 25 mm size ISI marked PVC casing capping including all fittings and fixing accessories complete all as specified and as directed.
10
-
-
S&F in repair 32 mm size ISI marked PVC casing capping including all fittings and fixing accessories complete all as specified and as directed.
10
-
-
Taking down copper/aluminium point wiring (light, fan, socket etc) complete, incl fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, lamp holder etc,refixing removed fittings and making good the disturbed surface of wall to match with existing surface complete all as specified and as directed.
38
-
-
Taking down submain wiring of any type complete all as specified and as directed.
40
-
-
Taking down DB of any size complete all as specified and as directed.
4
-
-
M&L for point wiring surface type with single core 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable (FRLS) including 1.5 Sqmm PVC insulated unsheathed copper conductor as earth continuity conductor drawn in and including ISI marked PVC casing caping not less than 25 mm width with its accessories, and fixed in existing sunk boxes and covered with new 3.00 mm thick ISI marked laminated sheet cover and brass screw with cup washers for fixing switches/sockets/regulators etc. for one light point controlled by one switch complete all as specified and as directed by the Engr-in-Charge
4
-
-
All as per srl item No 126 here in before but for one exhaust/ceilling /wall mounted fan controlled by one switch complete all as specified and as directed by the Engr-in-Charge
8
-
-
All as per srl item No 126 here in before but for one bell/buzzer point controlled by one push button on the same board complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 126 here in before but for one light point controlled by two 2-way switches complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 126 here in before but for one 5 Amps socket outlet point on same board complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 126 here in before but for one 5 Amps socket outlet point on independent board controlled by one switch complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 126 here in before but with cable 4.0 sqmm including 4.0 sqmm cable as earth wire for 15/16 amp socket complete all as specified and as directed by the Engr-in-Charge
4
-
-
M&L for point wiring in existing conduit/PVC casing caping concealed or surface type with PVC insulated, unsheathed, single core multistandard copper conductor cable (FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through existing PVC conduit/casing caping and fixed in existing sunk boxes and covered with new 3.0mm thick ISI marked laminated sheet cover and brass screw with cup washers for switches/sockets/regulators etc, for one light point controlled by one switch complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 133 here in before but for one exhaust/ceilling /wall mounted fan controlled by one switch complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 133 here in before but for one bell/buzzer point controlled by one push button on the same board complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 133 here in before but for one light point controlled by two 2-way switches complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 133 here in before but for one 5 Amps socket outlet point on same board along with other switch complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 133 here in before but for one 5 Amps socket outlet point on independent board controlled by one switch complete all as specified and as directed by the Engr-in-Charge
2
-
-
All as per srl item No 133 here in before but with cable 4.0 sqmm including 4.0 sqmm cable as earth wire for 15/16 amp socket complete all as specified and as directed by the Engr-in-Charge
2
-
-
M&L for sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC casing caping with all necessary accessories such as bends, tees,elbows etc complete all as specified and as directed. Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC casing caping with all necessary accessories will be measured as one unit length.
10
-
-
M&L for sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC casing caping with all necessary accessories such as bends, tees,elbows etc complete all as specified and as directed. Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC casing caping with all necessary accessories will be measured as one unit length.
10
-
-
M&L for sub main wiring in existing surface/recessed steel/PVC conduit/casing caping with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity complete all as specified and as directed. Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire will be measured as one unit length.
20
-
-
Disconnection of electrical wire from ceiling rose and taking down ceiling Fan of any type/size,make moreover dismantling the ceiling Fan for removing of old lubricating substatance from bearing/bush & applying fresh lubrication using grease to avoid noise free smooth functioning, including replacement of worn out/unserviceable spares as required and replacement of PVC insulated, unsheathed multi stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 0.5 M long incl testing the repaird ceiling fan to the entire satisfication of engineer in charge and refixing the fan in own position with provision of hanging bush, cotter pins, nut , bolts washers etc complete all as specified and as directed. Note : Rewinding of ceiling fan, bearing, capacitor and PVC wire for making connection shall be measured and paid seperately under respective item.
45
-
-
Rewinding of ceiling fan 230 volts , of any make/type and size (1200/1400 mm sweep) with copper wire of same gauge and number of turns as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor complete all as specified and as directed. Note : Ceiling fan before fix at site the RPM shall be checked and match as per manufactures specification till entire satification of Engr in charge
45
-
-
Carrying out re metalling in worn out shaft, cutting and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to entire satifaction of Engineer in change (Note : bearing shall be measured and paid seperately )
10
-
-
Supply only ball bearing of any size and type, suitable for any type/make/size of ceiling fan complete all as specified and as directed. Make - TATA/NBC/SKF or equivalent as approved by GE.
12
-
-
Supply and fixing capacitor capacity 2.5 MFD, 220 volt ISI marked complete all as specified and as directed.
20
-
-
Supply and fixing PVC insulated, unsheathed multistranded twin twisted copper flexible cable of size 1.5 Sqmm complete all as specified and as directed.
20
-
-
Supply only suitable size of bush for ceiling fan of any type/size complete all as specified and as directed. Make - TATA/NBC/SKF or equivalent as approved by GE.
40
-
-
Supply and fixing of PVC connector 4 way 6 Amps with connection screws, nuts. etc complete all as specified and as directed.
40
-
-
Supply and fixing PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and as directed.
40
-
-
Disconnection of electrical wire from exhaust fan and taking down exhaust fan of any type/size, make moreover dismantling the exhaust Fan for removing of old lubricating substatance from bearing/bush & applying fresh lubrication using grease to avoid noise free smooth functioning, including replacement of worn out/unserviceable spares as required and replacement of PVC insulated, unsheathed multi stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 0.5 M long incl testing the repaird ceiling fan to the entire satisfication of engineer in charge and refixing the fan in own position with provision of hanging bush, cotter pins, nut , bolts washers etc complete all as specified and as directed. Note : Rewinding of ceiling fan and PVC wire fro making connection shall be measured and paid seperately under respective item.
26
-
-
Rewinding of exhaust fan 300 mm sweep 230 volts , of any make/type a with super enamelled copper wire of appropriate gauge and number of turns as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete. Note : exhaust fan before fix at site RPM should be checked and match as per manufactures specification till entire satification of Engr in charge
18
-
-
Rewinding of exhaust fan 380 mm sweep 230 volts , of any make/type a with super enamelled copper wire of appropriate gauge and number of turns as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete. Note : exhaust fan before fix at site RPM should be checked and match as per manufactures specification till entire satification of Engr in charge
8
-
-
Supply and fixing of louver shutter made of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made o MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall fater driling, and duly painted by two coat of synthatic enamelled paint (spray painting) over a coat of primer for exhust fan up to 300/380 mm sweep complete all as specified and as directed by the Engr-in-Charge
4
-
-
M&L for fan motor suitable for PVC body exhaust fan upto 250 mm sweep and RPM match with existing incl taking down old motor and fixing of new with proper allignment and refixing the same using necessary mounting screws and accessories without any vibrations and noise to the satisfaction of Engr-in-Charge.
2
-
-
Supply and fixing capacitor 230 volt AC 50 HZ 4.0 MFD, 220 volt ISI marked complete all as specified and as directed by the Engr-in-Charge
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%