Military Engineer Services Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date1 Feb 2025
Closing Date1 Mar 2025
Tender Amount₹ 44,43,023 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated soil to a distance not exceeding 50m and deposited at a level not exceeding 1.5m above the starting point, complete all as specified and directed.

33.87

-

-

... More
M&L for sub main wiring three phase with 2 X10 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 Sqmm drawn through suitable size of non-metallic PVC rigid conduit with 10 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/recessed as required, connection up and taking down old wiring complete all as specified and directed.

41

-

-

... More
S&F MCB DB TPN, 4 Way, vertical double door, 415V, AC, 50 Hz for MCCB TPN as incommer and MCB TP as out going, IP- 43 protection confirming to IS-13032, universal mounting with copper busbar, neutral link, earth link, earthing shuds all as specified and directed

1

-

-

... More
S&F MCB TPN 415 volts 40 to 100 Amps, 10 KA rupturing capacity.B series all as specified and as directed.

2

-

-

... More
S&F MCB TP 415 volts 25 to 63 Amps, 10 KA rupturing capacity.B series all as specified and as directed.

5

-

-

... More
S&F MCB DB SPN 8 WAY , horrizontal, double door, 240 V, AC,50 Hz, for MCB DP as incommer and and SP MCBs as out going.IP- 43 protection universal mounting with copper busbar, neutral link, earth link, earthing shuds all as specified and directed

1

-

-

... More
S&F MCB DB SPN 12 Way , horrizontal, double door, 240 V, AC,50 Hz, for MCB DP as incommer and and SP MCBs as out going IP- 43 protection , universal mounting with copper busbar, neutral link, earth link, earthing shuds all as specified and directed

1

-

-

... More
S&F MCCB TPN 415 volts 25 to 100 Amps, 16 KA rupturing capacity, all as specified and as directed.

1

-

-

... More
Material and labour for plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) for foundations, filling in mass concrete, all as specified and as directed.

1.9

-

-

... More
Material and labour for plain cement concrete 1:2:4 type B1 (using (20 mm graded stone aggrega) for path ways, hard standing & pole coping including necessary form work and applying two coats of white wash on exposed surfaces etc complete all as specified and as directed.

0.6

-

-

... More
M&L for cutting road / hard standing to depth not exceeding 60 cm and width not exceeding 45 cm for laying HDPE Pipes and making good the disturbed surfaces by 1:3:6 type C1 (using 20 mm graded stone aggregate), complete all as specified and as directed.

21

-

-

... More
Supply and laying High density polyethylene pipes(HDPE) of 100 mm dia pressure rating 6 kgf/cm2 laid in trenches and fixed on poles, complete all as specified and directed.

21

-

-

... More
M&L for reinforced precast concrete cable cover, class ELV, type 1 with peak, size 250mm x 150mm x 40mm flat perpendicular to axis of cable for protecting complete all as specified and directed.

1914

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core including taking down old complete all as specified and directed.

340

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core including taking down old complete all as specified and directed.

20

-

-

... More
M&L for cable joint kit straight through heat shrink type for 1.1KV (Earthed) grade cable complete with jointing material and accessories siutable for XLPE insulated armoured aluminum conductor cable of size 25/50 sqmm, 3.5 core, all as specified and as directed.

2

-

-

... More
M&L for making cable connection from existing LT panel and proposed LT panel XLPE cable of size 240 sqmm 4 core with suitable lugs and cable glands, nuts bolts washers, all as specified and as directed.

2

-

-

... More
M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 25x4mm GI strip by means of bolts, nuts, check nuts and washers of galvanized iron upto test point and protected by GI pipe light grade 40 mm bore up to 7.5 Mtr connected to a main switch board or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover, PCC 1:3:6 type C2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in Electrical Plate No3 of MES Schedule Part – I of 2009, all as specified and as directed.

6

-

-

... More
M&L required for CPRI approved LT panel outdoor type of suitable size recommended by manufacturer cubical floor mounted type (IP-65 degree of protection ) made out of 3 mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200 amps rating made of aluminium strip (40x5mm) duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland incl 50x50x6 mm frame (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I with the following accessories :- INCOMING On load change over switch 125 amps 25 KA Adjustable type 4 pole -01 No

1

-

-

... More
OUTGOING (i) MCCB 125 amps 25 KA Adjustable type 4 pole - 01 No (ii) MCCB 63 amps 25 KA Adjustable type 4 pole -04 Nos @ as out/going (Working-02 , Spare-01) (iii) MCB 32 Amps TPN amps Adjustable type as per - 03 Nos (Working-02 , Spare-01) (iv) Multifunctional digital type Advanced Three phase meter Volt/Amp/KVA/KW/ +/- 1.0% rated current,auto and manual scrolling,site selectable suitable CT/PT ratios etc..housing in MS sheet 1.6 mm thick duly painted with enameled paint over a coat of primer complete in all respect all as directed & specified. (v) 3 Phase indicators LED type set of 3 - R,Y,B -O1 Set. Note :- Foundation shall be easured and paid separately

-

-

-

... More
Supply, installation , testing & commissioning of Floor Mounted precision controlled air conditioning unit of cooling capacity 3 TR , front discharge, Air Cooled DX type CRAC units for server room application, equiped with most advanced industry technology to operate at higher return air temperatures (Scalable upto 30 Deg C in case of additional load), guaranteeing precise control of machine room. The units shall be selected on the basis of following parameters: (i) 24 Deg C/50% RH of return air (ii) Supply air in between 16- 18 Deg C (iii) 45 Deg C of Design Ambient temperature (iv)Specific Power consumption shall be low as per site design conditions including compressor, evaporator fans and condensers. (Make: Stulz or equivalent)

5

-

-

... More
(v) The Indoor unit shall comprise of Scroll Compressor, Indoor fans, Evaporator DX Cooling Coil with hydrophilic coating, Microprocessor controllers, Thermostatic Expansion valves, Driers, G4 Filter, Suction and Discharge piping, Internal power and Control wiring, heaters, Infrared Humidifier, Heaters, HP/LP Cut outs, Power and Control contactors, water leak detectors and Other Electrical accessories. (vi) The system done by multiple units shall work with efficient cascade way, trying to maximise energy efficiency always working where EC Fan sare more effective. Fixed capacity compressor technology like multiple scrolls or Tandem scroll sarestrictly not allowed. Systems should mandatorily behaving variable capacity compressors and performance as per above specifications.

-

-

-

... More
(vii) The Outdoor Condenser unit shall comprise of Condenser fans & motor, Condenser cooling coil (Copper coil with aluminium fins), Fan speed controller, Isolaters witch. The condensing temperature of matching air cooled condenser not to exceed 51 Deg C at design conditions. (viii) The unit shall be suitable for operation on 415Volts, 50Hz, 3Phase, 4Wire AC supply. Each unit should behaving individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults, limiting values and PAC wellness alarm/service alarm to reduce the down time and unit memory shall hold the 100 most recent events with ID number, time and date stamp for each event.

-

-

-

... More
NOTE - Rate quoted shall deemed to include all the accessories requiired for installation , testing & commissioning of the system such as :- (i) Supply and filling of Refrigerant gas 410a complete. (ii) Supply, Installation, inter connecting and testing of 18 G copper piping of suitable size between indoor and outdoor unit, for hot gas line duly insulation within AC space along with tray complete all as specified and as directed. (iii) Supply, Installation, inter connecting and testing of 18 G copper piping between indoor and outdoor unit, for liquid line duly insulation within AC space along with tray complete all as specified and as directed. (iv) Supply & Installation of inter connecting copper cable of size 2.5 Sqmm x 3 Core between indoor & Outdoor Unit complete all as specified and directed.

-

-

-

... More
(v) Supply & Installation of copper cable of size 6 Sqmm 4 Core from incoming lsolator to CRAC Unit complete all as specified and as directed. (vi) Supply and fixing of 25 mm CPVC pipes including fittings for condense drain piping. (vii) Indoor unit base frame complete with vibration pads fittings and accessories, (viii) Outdoor unit base frame shall be grouted and complete with fitting and accessories. (ix) Any other spare parts required necessary for installation of AC units. (x) Lifting & transportation of AC outdoor units to building terrace

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.