Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Eprocure
Opening Date6 Dec 2024
Closing Date3 Jan 2025
Tender Amount₹ 34,50,000
Costs
EMD
₹ 69,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687316_1Bid Award Id
ViewTender No
GE/PNH-61/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
90
-
-
... More
M&L for Sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge
(Note : Punning thickness of 18 cm will be measured for payment purpose)
60
-
-
... More
M&L for Burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
5.8
-
-
... More
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 185 sqmm 3.5 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
75
-
-
... More
All as per Item No 7 above but size 3.5 core 120 sqmm complete all as specified and directed.
100
-
-
... More
All as per Item No 7 above but size 3.5 core 95 sqmm complete all as specified and directed.
200
-
-
... More
All as per Item No 7 above but size 3.5 core 70 sqmm complete all as specified and directed.
100
-
-
... More
All as per Item No 7 above but size 3.5 core 50 sqmm complete all as specified and directed.
250
-
-
... More
All as per Item No 7 above but size 3.5 core 35 sqmm complete all as specified and directed.
200
-
-
... More
All as per Item No 7 above but size 4 core 25 Sqmm complete all as specified and directed.
350
-
-
... More
All as per Item No 7 above but size 4 core 16 sqmm complete all as specified and directed.
400
-
-
... More
All as per Item No 7 above but size 2 core 10 sqmm complete all as specified and directed.
400
-
-
... More
Supplying, installation and erection in true vertical position steel tubular swaged welded pole, 9.0 metre long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW Mild steel tubing tubing including holes of required Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No with black paint by stenciled letters/figures of 8cm height, including taking down old EXISTING pole any type complete all as specified and directed. Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
10
-
-
... More
Dismantling of cross arms, bracings, supports, clamps etc of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
2
-
-
... More
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
2
-
-
... More
S&F in repair Pin type insulator Porcelain, vitreous white/ brown/ green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade, complete all as specified and directed.
20
-
-
... More
S&F in replacement Shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height in 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and directed.
100
-
-
... More
S&F in repair Stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 90mmx65mm clearance of hole 16 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps, excavation earth work & PCC work complete all as specified and directed.
6
-
-
... More
Supply and fixing in repair galvanised stay strand, size 7/3.15 mm for connecting stay assembly with MS clamps on poles complete all as specified and directed.
1
-
-
... More
Supply and fixing in repairs loop insulator porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, Complete all as specified and directed.
8
-
-
... More
S&F in replacement Cradle hexagonal , rectangular fabricated with GI wire 4 mm dia on existing OH line, complete all as specified and directed.
0.5
-
-
... More
M&L for dismantling of ACSR conductors and removing from the site complete all as specified and directed.
3
-
-
... More
Supply, stringing, stretching and binding with insulator, ACSR conductor of adequate size (Weasel /ferret/Mink) on LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified and directed.
3
-
-
... More
Trimming of tree branches coming in proximity to LT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches atleast 2.5 Mtrs apart from ACSR conductor from all sides complete all as specified and directed.
Note: Contactor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6" dia at his own arrangement and cost.
150
-
-
... More
M&L for Re-stretching of loose over head ACSR conductor of any type including GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire complete all as specified and directed.
Note: Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge. Note: Five lines together will be measured as one span from pole to pole.
176
-
-
... More
M&L for painting to steel poles including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
120
-
-
... More
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized iron pipe 15 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed.
NOTE: The unit rate includes earth wire and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
20
-
-
... More
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed.
NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
8
-
-
... More
S&F in repair Single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
10
-
-
... More
S&F in repair Test point terminal block made of gun metal or phosphorous bronze of size 75x75 x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to GI pipe/ wall for protection of test point complete all as specified and directed.
5
-
-
... More
S&F in repair galvanised iron tubing 'medium grade' with all fittings for lightmimg conductor of size 50 mm bore, complete all as specified and directed.
18
-
-
... More
S&F in repair aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawl plugs etc for conductor for roof and fixed on wall upto test point, complete all as specified and directed.
40
-
-
... More
S&F in repair Galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe, complete all as specified and directed.
NOTE : Excavation & earth work shall be measured and paid for seperately under relevant item of schedule.
25
-
-
... More
S&F in repair galvanised iron tubing 'light grade' with all fittings and fixed to poles, walls etc. with flat iron clamps/ bolts/ nuts /washers or laid in floors/under roads complete of size 40 mm bore,complete all as specified and directed.
60
-
-
... More
S&F in repair Tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete of size 80 mm bore, complete all as specified and directed.
18
-
-
... More
M&L for Painting of LT panel including preparation of old surfaces by scrapping old paint completely and applying two coats of super enameled paint over a coat of red oxide primer complete all as specified and directed.
5
-
-
... More
S&F in repair MCCB, 3 pole, 63 Amps, 415 volts, adjustable type with breaking capacity 16 KA Ics=75% Icu, complete all as specified and directed.
12
-
-
... More
S&F in repair MCCB, 3 pole, 100 Amps, 415 volts, adjustable type with breaking capacity 16 KA Ics=75% Icu, complete all as specified and directed.
6
-
-
... More
S&F in repair MCCB, 3 pole, 160 Amps, 415 volts, adjustable type with breaking capacity 35 KA Ics=100% Icu, complete all as specified and directed.
8
-
-
... More
S&F in repair MCCB, 3 pole, 200 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
8
-
-
... More
S&F in repair MCCB, 3 pole, 250 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
4
-
-
... More
S&F in repair MCCB, 3 pole, 400 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
2
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 400 sqmm size, complete all as specified and directed.
50
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 185 sqmm size, complete all as specified and directed.
50
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 120 sqmm size, complete all as specified and directed.
50
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 95 sqmm size, complete all as specified and directed.
200
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 70 sqmm size, complete all as specified and directed.
100
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 50 sqmm size, complete all as specified and directed.
200
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 35 sqmm size, complete all as specified and directed.
100
-
-
... More
S&F in repair aluminium thimble suitable for LT XLPE cable 25 sqmm size, complete all as specified and directed.
300
-
-
... More
M&L for plain cement concrete 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
1
-
-
... More
M&L for Plain cement concrete (1:4:8) Type D-2 (using 40mm graded crushed stone aggregates) as in foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
8
-
-
... More
M&L for Plain cement concrete (1:2:4) Type B-1 using 20 mm graded crushed stone aggregates, as in coping of steel tubular poles foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
1
-
-
... More
S&F in repair PVC spiral line spacer for LT over head line on 9.0 mtrs pole suitable for 2/3/4 wire, complete all as specified and directed.
100
-
-
... More
Supply and fixing in replacement energy efficient LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
40
-
-
... More
Supply and fixing in replacement energy efficient LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
30
-
-
... More
Supply and fixing in replacement energy efficient LED street light fitting 75 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
30
-
-
... More
Supply and fixing in replacement energy efficient LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
25
-
-
... More
Supply, fixing, testing & commissioning of LT weather proof panel board powder coated, outdoor type, double door shutter, made out of CRCA sheet 3 mm thick outer and 1.6 mm thick for inner door, confirming to IS 8623 with angle iron 50x50x6 mm, outdoor, floor mounting type with closed bus bar chamber and with Aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including PCC work, 0.6 Mtr above ground level, grouting etc including provision of suitable size of cable glands, cable lugs,nut, bolts,washers etc. (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron), including taking down old panel board, complete all as specified and directed and comprising of the followings:-
2
-
-
... More
INCOMING
(a) MCCB TPN 36 KA, 200 Amps- 1 Nos(I/C) OUTGOING
(a) MCCB TPN 25 KA, 100 Amps - 02 Nos
(b) MCCB TPN 16 KA, 63 Amps - 03 Nos
(c) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & 300 Amps for neutral -1 No
(e) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-300 Amps. Make: SECURE / MECO / C&S Electric/L&T
(f) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No 0-500 V. Make: SECURE / MECO / C&S Electric/L&T
(g) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder.
(h) On load Changeover Switch 415 Volts, 200 Amps 4 Pole - 01 Nos
-
-
-
... More
S&F in repair LT AB cable of size 3x35 sqmm twisted alround the bar messenger of 1x25 sqmm , made out of aluminium stranded circular compacted conductor, XLPE insulated all as per IS : 14255, IS 398 part-IV 7098 part-I including suspension clamp with eye hook at every 35 to 40 mtr span mounted on pole by means of MS clamp, complete all as specified & directed.
250
-
-
... More
M&L for complete servicing and repair of Split type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position and testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch
14
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 2.0 T capacity complete all as specified and directed.
2
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 1.5 T capacity complete all as specified and directed.
2
-
-
... More
Supply only Fan/blower electric motor single phase 230 V complete for inner unit complete all as specified and directed.
2
-
-
... More
Supply only Fan/blower electric motor single phase 230 V complete for outer unit complete all as specified and directed.
2
-
-
... More
Supply only Starting capacitor of suitable capacity complete all as specified and directed.
6
-
-
... More
Supply only Running capacitor of suitable capacity complete all as specified and directed.
6
-
-
... More
Supply only Overload protection of suitable capacity complete all as specified and directed.
6
-
-
... More
Supply only Drain pipe for Split unit PVC 20mm dia complete all as specified and directed.
25
-
-
... More
Supply only Fan blade of suitable size for outer unit complete all as specified and directed.
5
-
-
... More
Supply only Remote control kit complete for Split type AC complete all as specified and directed.
4
-
-
... More
Supply only Condencing unit of Split type AC 2 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed.
1
-
-
... More
Supply only Condencing unit of Split type AC 1.5 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed.
1
-
-
... More
M&L for complete servicing and repair of Window type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections etc and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch
2
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity complete all as specified and directed.
1
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity complete all as specified and directed.
1
-
-
... More
Supply only Capacitor of suitable capacity for Window AC 1.5/2 Ton capacity complete all as specified and directed.
2
-
-
... More
Supply only Auto cut thermostate of suitable capacity for window AC 1.5/2 Ton complete all as specified and directed.
2
-
-
... More
Supply only Overload protection for Window type AC 1.5/2 ton capacity complete all as specified and directed.
2
-
-
... More
Supply only Grill for window AC of suitable size/shape /model as required at site complete all as specified and directed.
1
-
-
... More
Supply only Fan blade of suitable size for window type AC unit complete all as specified and directed.
2
-
-
... More
Supply only Fan/blower electric motor single phase 230 V complete all as specified and directed.
2
-
-
... More
M&L for complete servicing and repair of Water Cooler any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch
12
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 40/80 Ltrs complete all as specified and directed.
2
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 60/120 Ltrs complete all as specified and directed.
1
-
-
... More
Supply only Fan/blower electric motor single phase 230 V complet for water cooler 40/80 or 60/120 Ltrs capacity water cooler complete all as specified and directed.
6
-
-
... More
Supply only Running capacitor of suitable capacity complete all as specified and directed.
4
-
-
... More
Supply only Starting capacitor of suitable capacity complete all as specified and directed.
4
-
-
... More
Supply only Auto cut thermostate switch for water cooler complete all as specified and directed.
4
-
-
... More
Supply only Overload protector for water cooler of any capacity complete all as specified and directed.
6
-
-
... More
Supply only Fan blade of suitable size complete all as specified and directed.
4
-
-
... More
Supply only Push cock/soft closing tap brass chromium plated of size 15 mm complete all as specified and directed.
7
-
-
... More
Supply only PVC connection pipe 600 mm long, both end screwed for water cooler complete all as specified and directed.
9
-
-
... More
Supply only ball valve PVC 15mm size for water cooler 40/80 ltr capacity complete all as specified and directed.
5
-
-
... More
M&L for complete servicing and repair of refrigerator/deep freezer of any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge.
Note:- Unsv accessories will be measured and paid seperately under respective items of Sch
6
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 165 Ltrs capacity complete all as specified and directed.
4
-
-
... More
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 286/310 Ltrs capacity complete all as specified and directed.
4
-
-
... More
Supply only Auto cut thermostate switch for Refrigerator defrosts type complete all as specified and directed.
6
-
-
... More
Supply only Overload protectors for regrigerations upto 310 Ltrs capacity complete all as specified and directed.
7
-
-
... More
Supply only Copper strainer filter for reftrigerator complete all as specified and directed.
6
-
-
... More
Supply only Relays suitable for refrigerators upto 310 ltr capacity complete all as specified and directed.
7
-
-
... More
Supply only Door switch for refrigerator complete all as specified and directed.
2
-
-
... More
Supply only Door spring for refrigerator complete all as specified and directed.
2
-
-
... More
Supply only Freezer chest door suitable for 286/310 Ltr capacity complete all as specified and directed.
1
-
-
... More
Supply only Magnetised door lock rubber strip 'D' type for regrigerator 286/310 Ltr cacpacity complete all as specified and directed.
1
-
-
... More
Supply only Evaporator coil assembly 165 ltrs capacity regrigerator with copper pipe complete all as specified and directed.
2
-
-
... More
Supply only Evaporator coil assembly 266/310 ltrs capacity regrigerator with copper pipe complete all as specified and directed.
2
-
-
... More
Supply only Fan motor for chiller unit as per existing make complete all as specified and directed.
2
-
-
... More
Supply and filling gas charging required to the System of suitable type R-34/12/32 /R22 or as per existing at site complete all as specified and directed.
15
-
-
... More
Supply and filling gas charging required to the System of suitable type 134a or as per existing at site complete all as specified and directed.
15
-
-
... More
S&F in repair base tray of window type AC 1.5/2 Ton capacity unit complete all as specified and directed including the following:- (a) Removing of compressor condenser, wiring kit, from base tray (b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted.
(c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch
1
-
-
... More
S&F in repair base of water cooler of any capacity unit complete all as specified and directed including the following:- (a) Removing of compressor condenser, wiring kit, from base tray (b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. (c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch 'A'
1
-
-
... More
S&F in repair Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 32 Amps MCB SP complete all as specified and directed.
6
-
-
... More
S&F in repair 6-32 Amps MCB SP, 10 kA, C series, complete all as specified and directed.
6
-
-
... More
S&F swing motor suitable for split AC of capacity 1.5/2 TR, complete all as specified and directed.
2
-
-
... More
Supply and fixing in repair PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 4.00 Sqmm complete all as specified and directed.
90
-
-
... More
Supply and fix in repair capillary copper tube for window , split, water cooler, refrigerator complete all as specified and directed.
10
-
-
... More
Taking down of split AC 1.5/2 T capacity from existing location to refixing in another location incl both inner and outer units (filling up gas if necessary ) incl connected accessories in complete all as specified and directed by Engr-in-Charge.
7
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements