Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Eprocure
Opening Date19 Dec 2024
Closing DateCancelled
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689309_1Tender No
GEAFU-59/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M & L for Sand cushioning for appropiate level before and after laying the cable of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
137.7
-
-
... More
Supply and fixing of Brick tiles; common burnt clay building /ducts bricks’ sub-class `B’ Designation 75 (230mmx115mmx75mm)
13
-
-
... More
S&F 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
S&F 50 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
M & L for road cutting incl necessary excavation 30 cm wide and 30 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
40
-
-
... More
Supply and Laying in repair/replacement Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed by Engr-in-Charge of following sizes :- Note Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles, Clamps, fastner,nut,bolt and washers etc rates shall deemed to be included in the quoted rates). Make- Havells/Gloster/Polycab
-
-
-
... More
Cable size 10 sqmm 4 core
500
-
-
... More
Cable size 16 sqmm 4 core
500
-
-
... More
Cable 25 sqmm 3.5 core
400
-
-
... More
Cable size 35 Sqmm 3.5 core complete
250
-
-
... More
Cable 50 sqmm 3.5 core complete
150
-
-
... More
Cable 95 sqmm 3.5 core complete
300
-
-
... More
Cable 120 sqmm 3.5 core complete
100
-
-
... More
cable 185 sqmm 3.5 core complete
100
-
-
... More
M&L in repair Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit (h) Funnel with watering pipe, wire meshetc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
10
-
-
... More
S & F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 20x3 mm copper strip complete all as specified and directed by Enginer-in-Charge.
50
-
-
... More
S & F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32x6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
100
-
-
... More
S & F in repair Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
10
-
-
... More
Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:-
Note :- Rate for labour and Electrician shall deemed to be included in the quoted price, not extra be paid for this items.
-
-
-
... More
Outdoor/indoor 70 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
20
-
-
... More
Outdoor/indoor 25 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
20
-
-
... More
Supply and fix heat shrinkable straight through joint kit and accessories of following capacities and type:-
-
-
-
... More
Straight through joint kit indoor/outdoor al conductor cable of size 70 to 150 Sqmm and 3.5/4 core
20
-
-
... More
Straight through joint kit indoor/outdoor al conductor cable of size 185 Sqmm and 3.5/4 core
20
-
-
... More
M&L for Bracket made out of 40 mm bore dia steel water tubing, light grade of over all length 1.00 metre including bending to shape and fixed to pole with and including mild steel clamps, bolts and nuts of appropriate size and shape as approved by Engineer-in-Charge complete all as specified and as directed
40
-
-
... More
Cleaning unwanted grass and vegetation in side and out side building/fencing/two/four pole structure/LT panel/bus Bar/feeder pillar and also around 2 m radius out side the fencing every three month duly taking out unwanted material grass/vegitable/roots of tree/small tree etc complete as specified and directed
50
-
-
... More
M&L for spraying the chemical (Roundup) in sub station in the ration 1: 3 for buring the grass every three month as specified and directed by Engr-in-charge.
500
-
-
... More
M&L for tracing the LT UG cable fault with either LT cable fault locator or manually digging by labour in any situation/position etc, complete all as specified and directed. NOTE:-Contractor has to rectify the fault within 08 hrs after info by concerned AGE/JE otherwise a penality of Rs 500/- per hrs would be imposed.
(ii) One Single cable of any length for end to end termination with any number/type of faults will be considered to consitute only one qty for tracing and payment purpose.
20
-
-
... More
M&L for Aluminium Lugs of size 35 sqmm complete all as per specified and directed.
200
-
-
... More
M&L for Aluminium Lugs of size 70 sqmm complete all as per specified and directed.
200
-
-
... More
M&L for Aluminium Lugs of size 95 sqmm complete all as per specified and directed.
200
-
-
... More
M&L for Aluminium Lugs of size 150 sqmm complete all as per specified and directed.
200
-
-
... More
M&L for Aluminium Lugs of size 185 sqmm complete all as per specified and directed.
200
-
-
... More
M & L for CRCA MS Sheet of any size alongwith fixing arrangement through nut, bolts or welding etc suitable for panel base plate or panel canopy all as specified and directed by Engineer-in-Charge.
Note :- (i) Rate include for making the hole in the gland according to the size of cable and re-connecting the cable in the existing panel etc.
(ii) Size of sheet shall be as decided and directed by Engineer-in-Charge.
100
-
-
... More
Supply & installation and testing & Commissining in repair CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick CRCA sheet, powder coated ,TPN copper busbars of rating 200 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on corrosive SMC insulator not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos
(d) CT of suitable ratio (Set of three)
Incoming: (a) MCCB 160 Amp, 415V, 50 Hz, FP, ,25 ka, Ics= 100% Icu, adjustable type, complete all as specified and directed by Engr-in-Charge.
Note :- 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates
3. Drawing of Lt feeder panel shall be got approved from GE.
5
-
-
... More
Supply & installation and testing & Commissining in repair CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick MS sheet for outer shell and 2 mm thick for inner shell having TPN copper busbars of rating 400 Amp Cap of length not less than 60 cm and suitable size of strip for 3 phase and neutral with colour code heat shrinkable sleeve and shall be mounted on high strength DMC material, inter connection of incoming and outging cable etc and Bottom base channel of MS section not less then 50 mm x 50 mm x 5 mm thick grouted in PCC block of size 30 cm x30 x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate and connection of cables with suitable size of thimble, nuts, bolts & washers including cable glands at entry and outlet points including execavation and earth work, returing filling and removal of surplus soil, double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers as per site requirement with the following :- (a) CT's of suitable ratio (Set of three) (b) Digital Voltmeter & Ammeter - 02 Nos (b) Phase indicator lamp RYB LED type - 1 Set (Set of three)
Incoming: (a) MCCB 250 Amp 415V, 50 Hz, FP, 36 ka, Ics= 100% Icu, adjustable type complete all as specified and directed by Engr-in-Charge.
Note :- Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates
3. Drawing of Lt feeder panel shall be got approved from GE.
5
-
-
... More
Laying over ground cables/Re-routing only LT UG cable of size 10 sqmm x 2,10 sqmm x 4 core to 185 sqmm x 3.5 core cable shall be provided under Sch 'B'/ the existing cable along with connection with LT panel/Pole or Other electrical equipment with proper thimble/Aluminium lugs etc making all electrical connections as directed by Engr-in-Charge.
Note :- (i) Execavation shall be got done alongwith other items of cable required for laying of cable and shall be paid in respective items for laying existing overground cables.
(ii) Quoted rates shall be inclusive of cutting of cable, provision of thimbles, lugs, stainless steel cable gland for connecting cable IN / OUT from Panels and Feeder Piller Boxes as per Site requirement.
(iii) The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed.
(iv) Extra use of cable shall be measured & paid separately in case of non availability of EM store.
(v) Execavation, Returning & filling, removing, sand and break work shall be measured and paid separately.
500
-
-
... More
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/PCC area of size 20 sqmm etc.complete all as specified & as directed.
500
-
-
... More
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/pcc area of size 40 sqmm etc.complete all as specified & as directed.
500
-
-
... More
M&L for repair to existing LT panels front and rear doors of locking arrangements by using suitable hinges fixed properly with suitable welding work complete all as specified and as directed by Engineer-in-charge.
50
-
-
... More
Painting to existing LT panel/ bus bar chamber/feeder pillar boxes including all MS work with two coat of aluminium spray paint and one coat of synthetic enamel paint over it (both sides) including panel legs finishing properly all as specified and directed.
50
-
-
... More
Supply and fixing in repair fire retardant electric insulation synthetic mat INSULATICA 2000" for 33 KV 2.5 mm thick of size 02x01 meter conforming to BIS DOC No ETD -02 (5231) P dt 2003. meeting requirement of IS 3043, IS: 5216 (Part 1,2,3) IS : 8437 and IEC 479 pub-1 IEC 61111 & 61112 tested for brake down strength tensile /elongation ageing properties. Insulation resistance, affects of acid , alkaline, Diesel & transformer oil, leakage current test fire test etc. having min width of 1000m + 20 mm complete as required suitable and using adhesive and allied chemical and scaling of all joints and border ends and fixing decorative taps the installed sheet complete as specified and directed.
30
-
-
... More
Supply, fix, testing and commissioning of air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 9 Nos porcelain insulators and steel channel frame, GI operating rod 25mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including 7 levers lock of Navtal make complete suitable for current rating of 400 Amps HT 11 KV working pressure all as specified and directed.
6
-
-
... More
S&F lighting arrestor explusion type complete with all fitting, transmission class, discharge capacity 65 kilo amps suitable for 11000 volts all as specified.
10
-
-
... More
Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 250 Amps with breaking capacity 35/36 KA complete all as specified and directed. Make :- Standard/Havells/Schneider/ABB or equivalent as approved by GE.
5
-
-
... More
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 100 Amps with breaking capacity 16 KA complete all as specified and directed. Standard/Havells/Legrand or equivalent as approved by GE.
5
-
-
... More
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 160 Amps with breaking capacity 35/36 KA complete all as specified and directed. Standard/Havells/Legrand or equivalent as approved by GE.
5
-
-
... More
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 400 Amps with breaking capacity 35/36 KA complete all as specified and directed. Standard/Havells/Schneider/ABB or equivalent as approved by GE.
4
-
-
... More
S&F & testing commissioning of outdoor type bus bar chamber weather proof ,CPRI approved MS cubical panel board outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 200 Amp capacity including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels copper busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. The panel shall be fixed over Angle iron frame (50 x 50 x4 mm) of minimum height 75 cm. Note :- Panel drawings shall be got approved from GE.
15
-
-
... More
Servicing and repair / maintenance of LT panel including checking of MCCB,s, Bus bar , cable lugs, voltmeter, ammeter and CTcoil etc for healthy operation and repairs / replacement of MCCB, BUS bar, Voltmeter, Ammeter ,Current Transformers (CTs) and replacing of defective control wiring if any replacement of defective cable lugs and complete for Indoor type / Outdoor type LT Panel of various capacity including necessary addition/ alternation of panel including cutting/welding/hinges of front and back side of panel board /feeder to match the existing panel board/feeder complete all as specified and directed.
Note:- Major spares like MCCB, Volt meter, Ammeter, Busbar and CT's, Epoxy insulator will be measured and paid seperately
10
-
-
... More
S&F in repair of MCCBs 100/125 Amps, 4 Pole
4
-
-
... More
All as per item No 41.01 above but 160 Amps, 4 Pole
4
-
-
... More
All as per item No 41.01 above but 250/200 Amps, 4 Pole
3
-
-
... More
All as per item No 41.01 above but 400 Amps, 4 Pole
2
-
-
... More
All as per item No 41.01 above but 63 Amps, 4 Pole
3
-
-
... More
M&L for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregates as in foundation filling land mass concerte for poles and stay/installation paths complete all as specified and directed.
1
-
-
... More
M&L for type PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for pole/ ducting including necessary form work complete all as specified and directed.
0.25
-
-
... More
M&L for Spray painting to existing LT panel board/Feeder pillar with two coats of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces complete all as specified and directed.
Make : Asian paints gattu/ Nerolack Hi-glass finish/ Berger Buterfly
10
-
-
... More
S & F Volt meter (0-500V) digital type with selector switch-01 No. Make : Secure or equivalent approved make.
5
-
-
... More
S & F Ammeter (0-30 amps) digital type with CT's and selector switch-01 No Make : Secure or equivalent approved make.
5
-
-
... More
Set of indicating lamp LED type-01 Set.
5
-
-
... More
S & F Current transformer of suitable size as per existing
5
-
-
... More
Taking down old unserviceable of earthing system and in replacement of Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm buried directly in ground vertically at a depth not less than 3.50 metre below normal ground level with top edge of earth plate at a depth not less than 3.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed alternate layer of common salt and charcoal and a top layer of copper sulphate 150 mm thick all as specified and as directed in drawing No CEAF/SK-60/2017 Dt 24.4.17 including bringing of mother soil from outside for filling holes, including Copper strip of size 20 x 3 mm by means of nuts, bolts and check nuts, washers of copper up to main board/test point or as required including necessary excavation and earth work in any type of soil so as to achieve earth resistance below 3 Ohms including excavation of polypit chamber with polyplastic pit cover (cost of polypit chamber with polyplastic pit cover shall be deemed to be included in the rate separated quoted) complete all as specified and as directed by Engineer-in-Charge including dismantling of existing unserviceable earthing.
Notes :
(a) Copper strip beyond test point shall be measured and paid for separately.
(b) Earthing resistance result shall be less than 5 Ω .If the result comes more than 5 Ω the contractor shall carry out the earthing at separate location/site given by the Engr-in-Charge after taking out of earth electrode without any extra cost to the deptt.
(c) Test point terminal block shall be measured and paid for separately.
(d) The contractor's quoted rates shall be deemed to include for dismantling/taking down of old unserviceable earthing of any type and making good the disturbed surfaces and nothing extra shall be admissible on this account.
(e) Any other fittings/fixtures if technically required for achieving desired results (if not included above) shall be provided by the contractor without any extra cost to the Govt.
(f) If mother soil is not available then mother soil wil be provided by contractor from outside source without any extra cost to the Govt.
10
-
-
... More
S& F in repair flood light 250 watt LED, IP66, 110 Lm/W flood light engergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable for installation in grid alongwith clamp etc for fixing arrangement incl taking down old one etc complete as specified and directed Make- HPL cat part No HPLLEDFL25060D or equivalent approved by GE.
10
-
-
... More
Repair and replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, PF= 0.90, lumen efficacy = 100 lumen/watts, 5700 K, includingsuitable SPD to be fixed in existing bracket at existing pole/bldg or other extra welding works complete all as specified including taking down old. Make : HPL cat part No HPLLEDSL9060E /Havells/Bajaj/C&S/Crompton/Polycab or equivalent as approved by GE
20
-
-
... More
Preparation of old painted surface and painting of steel tubular poles 9 mtr long from bottom to top incl all iron structure with synthentic enamelled paint in black and yellow colour up to 1.2 metre height from pedestal, including painting of steel structure, cross arms, bracings, supports, clamps and back plates (all metalic parts) of Steel Tubular pole complete, with two coats of Spray aluminium paint including preparation of old painted steel surfaces including writing in 80 mm wide letters/ numbers in both side of pole MES,LT/HT and pole No complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
Prediodical servicing of air circuit breaker and disconnecting the electrical connection from unserviceable parts and taking out the unserviceable material from the ACB and supply and fix the new material as per existing make/model/capacity incl cleanding and greasing fixed and movement parts etc complete as specified and directed Note :- (i) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system.(ii) Unit rates quoted by tenderers shall deem to include for, bolts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
2
-
-
... More
Supply only Shunt release
2
-
-
... More
Supply only Under voltage release
1
-
-
... More
Supply only Earth fault release
1
-
-
... More
Supply only Remote fault indicator
2
-
-
... More
Supply only Microswitch for indication
1
-
-
... More
Supply only lockable trip push botton
1
-
-
... More
Supply only locking ACB in isolating position
2
-
-
... More
Supply only locking ACB in any position
1
-
-
... More
Supply only racking interlock
1
-
-
... More
Supply only door interlock
2
-
-
... More
Supply only machinal operation counter
2
-
-
... More
Supply only Mounting kit for front mounted counter
1
-
-
... More
Supply only spring charge indication micorswitech
1
-
-
... More
supply only racking pad lock assembly
1
-
-
... More
S&F in repairs aluminium bus bar any rating incl cutting/drilling of suitable size holes as per required site and also GI nut,bolt,washer etc complete as specified and directed by Engr-in-Charge.
15
-
-
... More
M&L for cross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-Charge.
1
-
-
... More
Supply and fix Electric shock chart dust proof, water proof in which written electric shock and its treatment which is written in English and hindi for Sub Stations complete and fixed with good quality wooden frame and mirror of size 50 x 75 cm all as specified and directed by Engr-in-charge.
10
-
-
... More
M & L for PCC 1:3:6 type C2 with using 40 mm graded aggregate as in foundation of pole /for ducting with necessary form work complete as specified and directed
1
-
-
... More
M&L for type PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for pole/ ducting including necessary form work complete all as specified and directed.
1
-
-
... More
.S & F in repair automatic street light switch NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch ) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compund conforming to IP-66 The contactor, MCB and circuit wiring 16 sqmm copper shall be suitable enough to take load of 25 KW three phase load (8 KW/phase), contactor rating 40 Amps(2 pole)and 40 amps 4 pole and MCB (single pole) rating 63 amps (SP-3 Nos) complete including sheet metal enclosure with stand made of suitable size angle iron and grouting of enclosure using cement concrete 1:2:4 type B-I (using 20mm graded crushed stone aggregate) all as specified and directed by Engineer-in-Charge including taking down old.
Make :- Healer and Model No. SWADEEP-02EC25kW 3 PHASE .
2
-
-
... More
Supply and fixing of DWC HDPE tubing of black colour 25 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge.
Note :- (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate.
(b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc.
(c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates.
250
-
-
... More
Supply and fixing of DWC HDPE tubing of black colour 50 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge.
Note :- (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate.
(b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc.
(c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates.
250
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements