Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provision Of External Services For Mrsam At Af Station Sirsa in Fatehabad, Haryana. The bid opening date for this tender is 08-07-2021 and the last date for bid submission is 16-08-2021. Interested bidders for Military Engineer Services tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 4,48,300Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MES_449316_1Tender No
CEWAC/SIR/T-07/2021-2022Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Digital multifunction meter to measure energy and power parameters including power factor and frequency type RISH3430/Conserve 6400
(B) OUTGOING VCB - 2 Nos. Consisting of the following:
Short time current - 21 kA/ 3 sec
Making Capacity - 52.5 kA
Auxiliary contacts - 2NO + 2NC
Power frequency withstand voltage - 28 kV
Impulse withstand voltage - 95 kV ^
Nominal operating gas pressure -as per standard IS
Front cover mechanism - IP2X Cable covers - IP54 with Outer enclosure for outdoor type
Colour Shade of interior parts shall be of RAL 7035 and exterior parts shall be of IS 632
Internal arc type tested for 21 kA for 1 sec
Manual operated 630A Vacuum circuit breaker with built-in operating handle for manual operation. Three position disconnector / earthing switch downstream vacuum circuit breaker.
Three position single spring mechanism for disconnector / earthing switch. Anti Reflex operating handle for manual as well as motorised type
"Live cable" LED indicators through Capacitor yoltage Dividers mounted on ths bushings.
-
-
-
... More
NOTE: Schedule ‘A’ Part II to X are Prepriced by MES.
-
-
-
... More
Supply and fixing Cl sluice valves 100 mm bore(1.6 PN) with flanged ends, drilled, steel spindle, gun metal nut, operating wheel complete all as per IS 780- 1984 with ISI mark and fixed in position with rubber gasket joints, bolts nuts land washers complete all as specified and directed
3
-
-
... More
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
-
-
-
... More
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III
1
-
180954.56
... More
S&F Aluninium stud alloy Die casted of dimension 110x128x30mm dynamically designated having impact strength and-fixed with 2 No. highly reflective reflectors on both sides having the stud of an aluminium stem which is fixed by drilling a hole in the ground for better stability and fixing / sealed with Epoxy (as required) complete all as specified and as directed.
200
-
-
... More
M & L road line painting n exceeding 100 mm wide with golden yellow, white thermostatic compound with reflectorised glass beads on bitumen road providing and laying of hot applied thermostatic compound 2.5 mm thick including reflectorised glass beads @ 250 gm per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35 including cleaning of old road marking paint, the finished surface to be levelled, uniform and free streaks and holes in addition where arrows of letters are to be provided thermostatic compound may be machine sprayed the colour of compound with traffic diversion arrangements if required as per MORT&H clause 803.4 complete all as specified and directed
620
-
-
... More
Primary voltage: 11000:V3 V,
Secondary voltage: 110:V3 V -1 No
Number of metering windings: 1
Burden winding 25 VA winding class 1.0
Digital V-meter with inbuilt selector switch.
Space heater with thermostat CFL lamp and fitting with socket.
(D) Additional equipment delivered separately or mounted in respective panel.
All suitable material for interconnection of units.
Manometer -1 Nos Operating handle -1 No
Set of terminal protector boots for each module -1 Set Coupling of RMU and Metering module should be with the help of Bolted type arrangement, so that the coupling at site shall be easy. Plug-in type bushing shall not be acceptable.
Minimum 3 module should accommodate in one tank to avoid multiple coupling at site.
Note: Panel, Breaker, Relay and Vacuum Interrupter should be of same make. The contractor will submit NABL accredited lab test reports of the RMU's in original and the same shall be produced^well before claiming RAR payment of the RMU.
-
-
-
... More
All as per Serial Item NO 4.06 herein before but 80mm bore.
2
-
-
... More
M & L For Construction of masonry valve pit with burnt brick (sub class ’B') in cement mortar (1:6) and 10mm thick plastering in CM 1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally cement on 1.2m x 1.2mx 1.2 m with MS Sheet cover with locking arrangement hinged with 50x50x06 mm angle iron frame embedded in PCC (1:3:6) type C-1 etc. including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces completed including earth work all as specified and directed.
3
-
-
... More
External Water Supply
-
-
-
... More
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part VIII
1
-
71976.71
... More
ROAD
-
-
-
... More
Removing existing reftective road studs and refixing in position after relaying the road surface with nails and epoxy adhesive , complete all as specified and directed.
20
-
-
... More
Supply, Installation, testing and commissioning of factory made CPRI type tested outdoor type powder coated HT Feeder pillarbox of size not less than 2.0 x 2.0 x 1.0 Metej weather proof made out of MS sheet 3 15mm thick having common aluminium bus bar of capacity 400 Amp three phase 11 KV including foundation work and fencing outside with clear spacing of one meter from foundation and up to a height of two meter from ground level with door arrangement complete all as specified and as directed.
1
-
-
... More
Providing , laying,, spreading and compacting graded stone aggregate-(size range 53mm to.:075mm) to wet mix macadam (WMM) specification as per Table 400-1 of yellow book of WORTH including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers 75mm each( 225 mm compacted thicknesss) with, mechnical paverfinisher in sub-base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density & camber required, complete all as specified and directed. (Note:Mix will be prepared in plant of suitable capacity}.
1440
-
-
... More
Green (ON) / Red (OFF) push-buttons to operate VCB.
30/C + 1E/F self-powered numerical protection relay with Low and High set for Over current and Earth Fault. The relay shall have LCD display. Relay should have facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. The relay shall have RS485 port for communication on MODBUS protocol Mechanical ON/OFF/EARTH/Spring Charging Indication Cable boxes should be Arc Proof with hinged doors interlocked with respective Earthing Switches. Resin cast ring core protection CT 80-40/1 Amp, 5P10, 2.5VA-03 Nos.
Resin cast ring core metering CT 80-40/1 Amp, 5P10, 2.5VA - 03 Nos.
Digital multifunction meter to measure energy and power parameters including power factor and frequency type RISH3430/Conserve 6400
(C) Metering Unit with Bus PT - 1 Nos Consisting of following:
Air insulated metering module 12kV, 630A -1 Nos
Bushings outside cone interface C for connection of external bus bar - 1 No3 single pole voltage transformers epoxy coated ,resin cast with fuses on primary side & MCB on secondary side
-
-
-
... More
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part IX
1
-
2459929.7
... More
Supply laying, jointing and testing ductile iron Dl pipe of 100mm dia including rubber gasket spigot & socket ends centrifugally cast type K-9 ISI marked in any length laid in trenches as required at site complete all as specified and directed
500
-
-
... More
SCHEDULE `A' PART - XI MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
-
-
-
... More
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY"” as listed in Schedule ‘A’ Part IV
1
-
12508.5
... More
Construction of Under ground sump of capacity 5000 Gallons with permanent specifications complete all as specefied as shown on drawings
1
-
-
... More
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
1
-
37128.05
... More
All as per Serial Item NO 4.04 herein before but 80mm bore.
2
-
-
... More
Lump sum price worked out by the Contractor for “DISMANTLING AND DEMOLITION ” as listed in Schedule ‘A’ Part X
1
-
300491.75
... More
External Electric Supply
-
-
-
... More
Supply, installation, testing and commissioning of 11kV, 630Amp, 21 kA, Outdoor (with IP54) type extensible 3-way SF6 gas insulated RMU , floor mounted with copper bus bar Compact Distribution board consisting of 01 Nos incoming VCB and 2 Nos outgoing VCB and 01 air insulated metering. The extensible bushing should be at the top of RMU through bolted connection for ease of coupling. No plug-in type bushings are acceptable. All live parts, bus bars, VCB will be enclosed a single tank (Minimum 3 VCB in a single tank) in robotically Stainless steel tank filled with SF6 at 1.4 bar with IP class IP 67, leak rate less than 0.1% and tested for Internal arc 21kA/1-sec as per latest IEC 62271-200. The Compact Switchgear should be of IP54 degree of protection such that the main enclosure door should cover complete front part including front cover and cable covers. The earthing bus bar should be of copper. The earthing bus bar shall be provided in each cable compartment and throughout the length of Switchgear. The unit shall include the following with all necessary standard fitting required at site complete all as specified and directed.
(All VCB should be motorised)
(A) INCOMER VCB - 01 Nos. consisting of following:
Short time current - 21 kA/ 3 sec
Making Capacity - 52.5 kA
Auxiliary contacts - 2NO + 2NC
Power frequency withstand voltage - 28 kV
Nominal operating gas pressure - as per standard IS.
3
-
-
... More
Construction of Sub Station Building with Restroom and toilet with permanent specification complete all as specified and shown on drawing.
2
-
-
... More
Lump sum price worked out by the Contractor for “ROAD, WORKS” as listed in Schedule ‘A’ Part VII
1
-
17004000
... More
M & L for drilling hole under the road width for providing PVC pipe 110 mm dia for passing armoured cable / pipe complete all as specified and directedt complete all as specified and as directed.
30
-
-
... More
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
1
-
3236817.56
... More
Construction of sokage well, 1.20m dia x 3.00 m deep, exc in any type of soil, foundation in PCC 1:3:6, walls of honey combed and solid in M-25 concrete including intercepting chamber, screen chamber, brick work in CM 1:4, RCC cover slab in M-25 / RR masonry / filling with brick bats, with permanent specifications complete all as specefied as shown on drawings.
1
-
-
... More
S & F of UPVC Ball Valve valves of size 100mm , high pressure, with polythene float and flynut complete all as specified and directed
1
-
-
... More
Construction of static water Tank 1,10,000.00Ltrs capacity with permanent specifications complete all as specefied as shown on drawings
1
-
-
... More
M & L For Construction of masonry valve pit with burnt brick (Sub class 'B') in cement mortar (1:6) and 10 mm thick plastering in CM 1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally cement on 900 x 900 x 900mm with MS sheet cover with locking arrangement hinged with 50X50X6 mm angle iron frame embedded in PCC (1:3:6) type C-1 etc. including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces completed including earth work all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements