Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 85,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690696_1Tender No
GE/SRA/T-59/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, installation, testing & commissioning of addressable Photo electric smoke detector with multiple sensitivity, programmable for automatic sensitivity selection with base & other requisite and standard accessories, duly EN 45 listed and ISI marked complete all as specified and directed. (MAKE - HONEYWELL, MODEL NO: HM/PSE/S2 + MI/B501AP/IV or equivalent model in other makes specified in tender)
122
-
-
... More
Supply, installation, testing & commissioning of addressable multi sensor detector with heat and smoke combination multiple sensitivity, programmable for automatic sensitivity selection with base & other requisite and standard accessories, duly EN 45 listed and ISI marked complete all as specified and directed. (MAKE - HONEYWELL, MODEL NO: HM/PTSE + I/B501AP/IV or equivalent model in other makes specified in tender)
122
-
-
... More
Supply, installation, testing & commissioning of Conventional beam detector with reflector, suitable for protecting open area with high ceiling area where other methods of smoke detection are difficult to install complete all as specified and directed.
(MAKE: HONEYWELL, MODEL NO: BEAM1224S or equivalent model in other makes specified in tender)
3
-
-
... More
Supply, installation, testing & commissioning of addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected complete all as specified and directed.
(MAKE: HONEYWELL, MODEL NO: MI/DISO or equivalent model in other makes specified in tender)
11
-
-
... More
Supply, installation, testing & commissioning of addressable Control module, capable of providing DPDT contact rated at 24V DC, 2A. (For hooter/strobe) complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: MI/DCMO or equivalent model in other makes specified in tender)
11
-
-
... More
Supply, installation, testing & commissioning of addressable Monitor module for monitoring the field devices & capable of providing DPDT contact rated complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: MI/DMMI or equivalent model in other makes specified in tender)
11
-
-
... More
Supply, installation, testing & commissioning of addressable Control relay module for AHU/CSU units tripping, access door release and capable of providing DPDT contact rated at 240V AC, 2A complete all as specified and directed.
(MAKE: HONEYWELL, MODEL NO: MI/D24CMO or equivalent model in other makes specified in tender)
3
-
-
... More
Supply, installation, testing & commissioning of Manual Call Point including necessary back box / junction box for mounting Lever Pull Type complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: HM/MCP/GLASS or equivalent model in other makes specified in tender)
11
-
-
... More
Supply and Fixing Response indicator for above ceiling detector complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: RI/007H or equivalent model in other makes specified in tender)
60
-
-
... More
Supply, installation, testing & commissioning of LOOP SOUNDER Hooter cum strobe dual tone type with suitable M.S.CRCA housing and wiring circuit, with powder coated finish of approved colour complete all as specified and as directed. (MAKE: HONEYWELL, MODEL NO: WSO-PR-N05 + MI/B501AP/IV or equivalent model in other makes specified in tender)
11
-
-
... More
Supply, Laying and testing of FRLS, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded copper conductor of size 1.5 sqmm 2 core, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles, jointing and testing complete all as specified and directed. (Note :- Necessary earth work to be measured and paid separately.
7000
-
-
... More
Supply & Fixing circuit/submain wiring with 2x1.5 sqmm FRLS PVC insulated copper conductor, single core cable, surface mounted in and including ERW steel conduit 20mm dia (excluding junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. as required complete all as specified and as directed
NOTES: (i) Two runs of 1.5 sqmm wire and one run of ERW conduit shall be measured as one unit.
700
-
-
... More
S&F MS junction box, screw type, suitable for 20 mm OD MS ERW pipe complete all as specified and directed for the following types :-
-
-
-
... More
01 Way
20
-
-
... More
02 Way
30
-
-
... More
03 Way
30
-
-
... More
04 Way
30
-
-
... More
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for taking out/up and laying of Water Main /Pipe, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
130
-
-
... More
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Surplus Soil providing in Heaps along the Route of the Pipe Line in Soft/Loose Soil, complete all as specified and as directed.
338
-
-
... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
33
-
-
... More
Supply & Laying HDPE pipes, conforming to IS-4984, 40 mm OD, PN 10 with all fittings, laid in trenches for protection of cable complete all as specified and as directed
4252
-
-
... More
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (up to 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
4
-
-
... More
GENERAL NOTES FOR THE WHOLE WORK:-
(1) The Contractor shall employ the services of the designated Fire Alarm Specialist Supplier for the design, supply and commissioning of the fire alarm system. It shall consist of fire alarm sounders, break-glass units, heat and smoke detectors and control units.
(2) After commencement of work, the contractor shall be provided with layout plan of the designated building. The Fire Alarm Specialist Supplier shall supply and install a fire zone chart showing plans of the building with all fire alarm control and indicating equipment clearly indicated. Each fire compartment/zone shall be easily identified by means of clearly marked colour codes. The fire zone chart shall be as a minimum sized A3, coloured and suitably framed to be handed over on completion of the works.
(3) The Contractor shall arrange for the complete commissioning of the fire alarm system by the specialist fire alarm supplier.
(4) The whole of the fire alarm installation should be inspected, tested and commissioned in accordance with clause 26 of BS 5839 part 1 and as further described. Commissioning shall be carried out in accordance with Clause 26.5 of BS 5839 part 1 which shall include:-
(i) An audibility test of the alarm devices. Audibility level readings shall be taken in each room. Any sound levels found to be lower than 65 dba shall be reported to the Engineer-in-charge in writing.
(ii) All trigger devices i.e. manual call points, heat and smoke detectors shall be tested for correct operation,
(iii) A mains failure test shall be carried out to verify correct operation of the backup battery system.
(5) Prior to commissioning, the Contractor shall provide a certificate of installation and cable test certificates of the system to the EIC. contd.....
-
-
-
... More
(6) After commissioning of the fire alarm system, the contractor shall get the fire alarm system inspected and certified from State Government Fire Inspector under his own arrangement. Completion certificate shall be issued by GE only after satisfactory certification by Fire Inspector.
(7) The provisions/requirements mentioned here-in-before are in brief and shall be read in conjunction with particular specifications provided in this tender, relevant paras of SSR Part-I, 2009 and Indian Standards. The contractor is liable to complete the work as per latest guidelines of fire safety issued by Central/State Government. Rates quoted by the contractor shall be deemed to be inclusive of all the above aspects. No claims, whatsoever shall be admissible during currency of work.
(8). Around 948 RM of 40mm OD HDPE pipe has been laid by the previous contractor under BOQ Item No 20 and is available on site. Requisite items for excavation in trenches and partial returning filling has also been carried out. These quantities have not been considered in BOQ. The contractor shall utiliste the ibid items and complete the work in totality keeping in consideration the above aspect. He may, also visit the site with prior permission of AGE E/M (AF) Sirsa during office hours. No claim shall be entertained during currency of work.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%