Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date11 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(i) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 10 KVAR - 02 Nos. (j) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 5 KVAR - 02 Nos. Note : (i) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles. (ii) Drawing, circuit diagram and all materials / instruments incl makes etc for starter panel shall be got approved by GE before fabrication. (iii) Location for Panel : New Pump Pump House & Command Pump House. Make:- As specified in list of makes as given in Appx 'B' of PS for Group - I of LT Panels.

-

-

-

... More
Design, fabricate, supply, installation, testing and commissioning of indoor type motor Starter Panel floor mounting of size not less than 800mm x 900mm x 500mm Polycarbonate CPRI approved OEM made suitable for , shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only.

3

-

-

... More
Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warranty certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960 degree celsius in accordance with IEC - 60695-2-11 (flame retardant and self-extinguishing) with MC 75 for base frame & angle iron 50 x 50 x 6 mm size legs , 04 nos legs 600 mm long for mounting the panel board with a minimum ground clearance of 450 mm above GL to the bottom of panel including PCC foundation with PCC 1:2:4 type B-1 graded aggregate stone for grouting of base,suitable for 3 phase 415 volts 50 Hz 4 wire AC supply supply with steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of Panel box and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and incl the following:- BUS BAR :- (a) 3 Phase 4 wire copper bus bars of suitable length & section not less than 30 x 10mm covered with coloured heat shrinkable anti track insulation tape of make Denson/ M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 set.

-

-

-

... More
INDICATING DEVICES :- (a) Multifunction digital meter compatible to measure current, voltage, power factor & frequency with 3 lines LCD display in 96mm x 96 mm flush mounted case, accuracy class 1.0 - 01 No. (b) Resin cast CT 250/5A cast resin base – 01 set of 03. (c) LED type phase indicator lamp RYB – 02 set of three (d ) On/Off push buttons - 04 and selector switches - 02 Nos complete all as specified and directed. SWITCHGEARS COMPONENTS :- (a) I/C fast acting Semiconductor Fuse 160 A - 03 Nos (b) MCCB 3 pole, 160 Amps, 415 volts, 50 Hz, Icu- 36 kA, adjustable thermal & fixed magnetic release type - 01 No (c) ) Line contactor, AC 3 duty, 415 Volts, 50 Hz, 140 Amps-01 No. (d) Control Transformer 01 Nos. (e) Digital soft starter suitable for100 HP(75KW) motor, 3 phase, 415 Volts - 01 Nos. (f) MCB TP 32 Amp - 04 Nos. (g) Capacitor duty contactor, 3 phase, 415 volts, 50 Hz, of rating 12.5 kVAr – 2 Nos. (h) Capacitor duty contactor, 3 phase, 415 volts, 50 Hz, of rating 8.5 kVAr – 2 Nos. (i) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 10 KVAR - 02 Nos. (j) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 5 KVAR - 02 Nos.

-

-

-

... More
Note : (i) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles. (ii) Drawing, circuit diagram and all materials / instruments incl makes etc for starter panel shall be got approved by GE before fabrication. (iii) Location for Panel : New Pump Pump House. Make:- As specified in list of makes as given in Appx 'B' of PS for Group - I of LT Panels.

-

-

-

... More
Design, fabricate, supply, installation, testing and commissioning of indoor type motor Starter Panel floor mounting of size not less than 800mm x 900mm x 500mm Polycarbonate CPRI approved OEM made suitable for , shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only.

1

-

-

... More
Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warranty certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960 degree celsius in accordance with IEC - 60695-2-11 (flame retardant and self-extinguishing) with MC 75 for base frame & angle iron 50 x 50 x 6 mm size legs , 04 nos legs 600 mm long for mounting the panel board with a minimum ground clearance of 450 mm above GL to the bottom of panel including PCC foundation with PCC 1:2:4 type B-1 graded aggregate stone for grouting of base,suitable for 3 phase 415 volts 50 Hz 4 wire AC supply supply with steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of Panel box and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and incl the following:- BUS BAR :- (a) 3 Phase 4 wire copper bus bars of suitable length & section not less than 30 x 10mm covered with coloured heat shrinkable anti track insulation tape of make Denson/ M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 set.

-

-

-

... More
INDICATING DEVICES :- (a) Multifunction digital meter compatible to measure current, voltage, power factor & frequency with 3 lines LCD display in 96mm x 96 mm flush mounted case, accuracy class 1.0 - 01 No. (b) Resin cast CT 200/5A cast resin base – 01 set of 03. (c) LED type phase indicator lamp RYB – 02 set of three. (d ) On/Off push buttons - 04 and selector switches - 02 Nos complete all as specified and directed. SWITCHGEARS COMPONENTS :- (a) I/C fast acting Semiconductor Fuse 200 A - 06 Nos (b) MCCB 3 pole, 200 Amps, 415 volts, 50 Hz, Icu- 36 kA, adjustable thermal & fixed magnetic release type - 01 No (c) Line contactor,AC 3 duty,415 Volts, 50 Hz,80 Amps-01 No. (d) Control Transformer 01 Nos. (e) MCB TP 32 Amp c curbe - 04 Nos. (f) Capacitor duty contactor, 3 phase, 415 volts, 50 Hz, of rating 12.5 kVAr – 2 Nos. (g) Capacitor duty contactor, 3 phase, 415 volts, 50 Hz, of rating 8.5 kVAr – 2 Nos. (h) Power factor capacitor, ultra heavy duty advanced APP technology,3 phase, 440 volt, 50Hz of rating 10 KVAR - 02 Nos. (i) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 5 KVAR - 02 Nos. (j) Digital soft starter suitable for50 HP(40KW) motor, 3 phase, 415 Volts - 02 Nos. (l) MCCB 3 pole, 100 Amps, 415 volts, 50 Hz, Icu- 36 kA, adjustable thermal & fixed magnetic release type - 02 No.

-

-

-

... More
Note : (i) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles. (ii) Drawing, circuit diagram and all materials / instruments incl makes etc for starter panel shall be got approved by GE before fabrication. (iii) Location for Panel : Fd Regt Pump House. Make:- As specified in list of makes as given in Appx 'B' of PS for Group - I of LT Panels.

-

-

-

... More
Design, fabricate, supply, installation, testing and commissioning of indoor type motor Starter Panel floor mounting of size not less than 800mm x 900mm x 500mm Polycarbonate CPRI approved OEM made suitable for , shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only.

1

-

-

... More
Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warranty certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960 degree celsius in accordance with IEC - 60695-2-11 (flame retardant and self-extinguishing) MC 75 for base frame & angle iron 50 x 50 x 6 mm size legs , 04 nos legs 600 mm long, for mounting the panel board with a minimum ground clearance of 450 mm above GL to the bottom of panel including PCC foundation with PCC 1:2:4 type B-1 graded aggregate stone for grouting of base,suitable for 3 phase 415 volts 50 Hz 4 wire AC supply supply with steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of Panel box and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and incl the following:- BUS BAR :- (a) 3 Phase 4 wire copper bus bars of suitable length & section not less than 30 x 10mm covered with coloured heat shrinkable anti track insulation tape of make Denson/ M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 set.

-

-

-

... More
INDICATING DEVICES :- (a) Multifunction digital meter compatible to measure current, voltage, power factor & frequency with 3 lines LCD display in 96mm x 96mm flush mounted case, accuracy class 1.0 - 01 No. (b) Resin cast CT 63/5A cast resin base – 01 set of 03. (c) LED type phase indicator lamp RYB – 02 set of three (d ) On/Off push buttons - 04 and selector switches - 02 Nos complete all as specified and directed. SWITCHGEARS COMPONENTS :- (a) I/C fast acting Semiconductor Fuse 60 A - 03 Nos (b) MCCB 3 pole, 63 Amps, 415 volts, 50 Hz, Icu- 36 kA, adjustable thermal & fixed magnetic release type - 01 No (c) ) Line contactor, AC 3 duty, 415 Volts, 50 Hz, 45 Amps-01 No. (d) Control Transformer 01 Nos. (e) Digital soft starter suitable for25 HP(20KW) motor, 3 phase, 415 Volts - 01 Nos. (f) MCB TP 16+ Amp c curbe - 02 Nos. (g) Capacitor duty contactor, 3 phase, 415 volts, 50 Hz, of rating 5 kVAr – 2 Nos. (h) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 5 KVAR - 02 Nos.

-

-

-

... More
Note : (i) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles. (ii) Drawing, circuit diagram and all materials / instruments incl makes etc for starter panel shall be got approved by GE before fabrication. (iii) Location for Panel : Command Pump House. Make:- As specified in list of makes as given in Appx 'B' of PS for Group - I of LT Panels.

-

-

-

... More
S & F in replacement, multi stranded, 50 Sqmm, 3 core, PVC insulated and sheathed, unarmoured copper conductor cables, 1100 volts, with copper conductor, ISI marked, IS-694 complete all as specified and as directed.

120

-

-

... More
Supply, installation, testing & Commissioning of micro wave water flow meter for upto 600 mm Line size with following Features for pumping discharge line/delivery line all enclosed in weather proof M.S Box of 1.5 mm thick sheet powder coated including taking down old unserviceable flow meter complete all as specified of suitable size:- a)  Micro wave water flow meter with digital display and data parameters setting key board. b)  With output data for total flow & total consumption of water per day, week, month & year With time and date. c)  With printing facility for data of water consumption via wireless V sat receiver unit in excel format via computer based Software for record generation. d)  With RS 232 & 485 output pot. e)  With SMPS power supply of 12V & 5 V DC (10 amp) 230 V AC. f)   With monitoring of flow rate of pump set discharge output line with low pump set flow rate alert as per set parameters of low discharge alert via ringer tone based voice calling to 5 mobile nos and NON SMS based alert.

1

-

-

... More
Supply, installation, testing & Commissioning of Vsat satellite controlled high power transmitter unit (Non GSM/NON GPRS,NON INTERNET,NON RF, NON RTU based data Transmission) With Vsat microchip antenna to transmit water flow data via micro wave flow meter to control room via Vsat data receiver/transmitter unit all enclosed in MS Powder coated box of 1.5 mm thick sheet of suitable size,with SMPS power supply of 12V DC,9 amp.

1

-

-

... More
Supply, installation, testing & Commissioning of Vsat satellite controlled high power Receiver/ transmitter panel (Non GSM/NON GPRS,NON INTERNET,NON RF, NON RTU based data Transmission) with Vsat micro chip antenna with SCADA software for monitoring data for upto 08 nos micro wave flow meter via remote computer and mobile phone with coded operation and can be extended up to “N” Nos micro wave flow meter in future to be fitted at AGE E/M office.

1

-

-

... More
Supplying & Fixing on wall / laying in ground 2 X 1.5 Sqmm PVC insulated & PVC Copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all As Specified and directed by Engr -in-Charge.

25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.